| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.2 L+₹52,251.18 (4.12%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹13.2 L+₹55,903.60 (4.41%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹13.8 L+₹1.1 L (8.42%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
25 Nov 2020, 6:00 pmClosed
GE ALWAR
GE ALWAR
PROVN OF SANITATION FACILITY WITH CONNECTED WORKS UNDER AGE BR- II AT ITARANA ALWAR
2020_MES_390163_1
8965/E8
Open Tender
Civil Works
Item Rate
120 days
ALWAR
AS PER NIT
3 documents required · 3 mandatory
₹500
GE ALWAR
₹29,000
Yes
11 Dec 2020
27 Oct 2020
27 Nov 2020
27 Oct 2020
25 Nov 2020
11 Nov 2020
27 Oct 2020 - 10 Nov 2020
Amount
Surface dressing not exc 15cm deep in soft/loose soil complete all as specified and directed by Engr-in-Charge. Note : Removing of vegetation / shrubs / brushwood / undergrowth and carrying away rubbish to a distance of 50 m deemed to included in quoted rate.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft / loose soil.
Excavating in trenches not exc 1.5m wide and not exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes etc not exc 10Sqm on plan and not exc 1.5m in depth and getting out in soft / loose soil complete all as specified and directed.
Earth filling under floors including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. Note :- Soil obtained from excavation under item 2.00 here-in-before shall be used for filling.
M&L for Moorum / red bajri filling in floors or pavings, laid in layers not exc 15cm thick, spread, levelled and blinded with earth and rammed including watering complete all as specified and directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified& directed by Engr-in-Charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level n. exc 1.50 metre above the starting point complete all as specified.
M&L for anti-termite treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (area of the substructure in contact with backfill to be measured) complete all as specified and directed by Engr-in-Charge.
M&L for anti-termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engr-in-Charge.
M&L for anti-termite treatment to the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engr-in-Charge.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for form work to sides of Pillars, posts, struts piers, columns etc in squarre, rectangular or polygonal, rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to chajjas, chullah hoods, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in foundations including rafts, footings, foundation beams, bases for columns, mass concrete and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate in lintels upto 1.5m clear span, seismic and other similar bands, lintel bands, plinth bands, roof bands and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in columns, pillars, piers, posts, struts and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded stone aggregate in chajjas and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No.24.00 above but 6mm dia to 8 mm dia.
All as per item No.24.00 above but 5mm dia and over up to & including 10mm dia in stirrups, spacers & binders.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
M&L for precast cement concrete (1:2:4 type B0 using 12.5mm graded crushed stone aggregate) louvers and jallies, 50mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:6 complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brick work of walls including finishing the surface fair and even complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with water proofing admixture (ISI marked) as per manufacturer’s instructions, finished even and smooth without using extra cement complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces of ceiling including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for 15mm thick plaster over top of roof slab/chajjas in CM 1:4 mixed with water proofing admixture (ISI marked) as per manufacturer’s instructions, finished even and smooth without using extra cement all as directed. Note : - Supply only water proofing admixture shall be measured and paid for separately.
Supply only integral liquid water proofing compound (ISI marked).
M&L for 100 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
M&L for coloured non skid ceramic tiles (1st quality), 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles (1st quality), 300mm x 450mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:6 complete all as specified and as directed.
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam sheet instead of wood grain printed PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S&F factory Made Solid PVC Moulded Door Shutter, With Particle Board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing in SSR.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified.
S&F butt hinges of size 100mm medium weight, cold rolled mild steel ISI marked complete all as specified.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified
S&F extruded aluminium alloy handle, 150mm size, fabricated type, anodized (ISI marked) complete all as specified.
M&L for 50 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminous primer @ 0.40 Kg/Sqm conforming to IS : 3384 and applying a layer of APP based polymeric membrane not less than 3mm thick weighing not less than 3.50 Kg/Sqm, reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) and upper side of membrane thermally insulated with white gravel finish uniformly embedded during manufacturing process. It shall be laid by torch application having side over lap 75 mm and at the end 100 mm, all overlaps and joints shall be sealed by torch application. For parapet, membrane shall be taken to a height of minimum 60 cm and inserted inside the parapet in a groove to a depth of 65 mm. The same shall be finished by a membrane flashing. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.
S&F galvanised steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
S&F galvanised steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc. and making good, cutting not exc 10 cm girth in brick walls.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I
S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and as directed.
S&F 20mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe copmplete all as specified and directed.
S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&F fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore.
S&F 15mm bore stop / angle valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F 15mm bore Stop valve fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union.
S&F 15 mm bore bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed
S&F brass chromium plated shower rose 125mm size without swivel joint including fixing to steel pipe of 15mm bore or union complete all as specified.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified.
S&F 110 mm bore PVC (SWR) single junction (single 'T' ) equal or unequal with access door complete all as specified.
S&F PVC (SWR) reducer 110mm to 75mm bore complete all as specified.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified.
S&F 75mm bore PVC (SWR) single junction (single ‘T’) equal or unequal complete all as specified.
S&F PVC (SWR) floor trap plain with PTMT grating including jointing with solvent cement, diameter of outlet 75mm, complete.
S&F vitreous china urinal, half stall type, white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws (excluding flushing cistern, flush pipe and waste pipe) complete all as specified.
S&F urinal spreader of PTMT any colour for fixing with 15mm bore pipe (Minimum weight 60 gms) complete all as specified.
S&F vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including making good to distrubed surfaces of floor to match with existing sorroundings complete all as specified.
S&F PVC valveless, syphonic action type, flushing cistern, low level, white (ISI marked) of 10 litre capacity with inlet, ball valve, float and handle including brackets, flush pipe of polyethylene of low or high density or 32 mm dia PVC pipe, for low level cistern connections to pipes and fixing of chain and pull, or lever, if any complete all as specified..
S&F vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including cutting for and pinning in ends of brackets or erecting stand, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed complete all as specified.
S&F stainless steel peg set of six fixed to wall with two rawl plugs and chromium plated (CP) brass screws complete all as directed.
S&F tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges fixed to wall complete all as specified and directed.
M&L for preparation of newly plastered surface of walls & applying three coats of white wash complete all as specified.
M&L for preparation of newly plastered / asbestos cement surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of newly plastered surface of walls and applying two coats of cement base paint of approved shade / tint over a coat of alkali resistant priming paint complete all as specified.
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified.
M&L for cement concrete 1:2:4 type B0, using 12.5mm graded crushed stone aggregate as in copings and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified and directed.
M&L for for PCC 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in water through, surface channels and drains including necessary formwork, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc.
M&L for precast RCC 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes etc. including placing in position and set in CM (1:4) complete all as specified and directed. Note :- Reinforcement shall be measured and paid for separately.
M&L for 150mm bore reinforced concrete pipe, class NP2, laid and jointed (in CM 1:1) complete with collars complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in bedding to SGSW drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in kerb stone block (factory casted) with plain fair faces, including weathering, slightly rounded or chamfered angle throating, with plain or interlocking joints and setting in cement mortar 1:4, complete, all as directed.
M&L for factory made 60mm thick machine pressed precast cement concrete interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified and directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS and including MS sunken boxes fixed on wall with and including 3mm thick phenolic laminated sheet top cover for mounting switches, sockets, fan regulators etc complete all as specified.
All as per serial item No. 89.00 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 89.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item No. 89.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No. 89.00 here-in-before but for one 3 pin socket outlet 15/16 Amps with 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230 Volts complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15/16 Amp, 230 Volts complete all as specified and directed.
S&F socket outlet for 3 pin, 5/6 Amp, flush type 240 Volt complete all as specified and directed.
S&F socket outlet for 2 in 1, 3 pin 5/6 & 15/16 Amp, flush type 240 Volt complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x50mm two or three terminals complete all as specified and directed.
S&F decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for 16 Watt to 20 Watt with LED tube 6000K of model E-LITE LED Pride Plus and connecting up with and including three core, PVC insulated, sheathed copper conductore cable of required size and length from ceiling rose to fitting complete all as specified & directed. Make :- Havells Cat Part No LHEXBLP7PN1W018 or equivalent of Syska / Crompton Greaves as approved by GE
Supply and fixing LED type street DRACO Series light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete, all as specified & directed. Make :- C&S Cat Part No LTESS20WLED or equivalent of Havells / Syska / CG as approved by GE
Supply & fixing and testing exhaust fan of 300mm sweep suitable for SP 230 / 240 volt, 50 Hz AC supply complete with louver shutter including fixing / grouting of frame in wall & cutting opening complete with covers & connecting complete all as directed.
S&F sheet metal enclosures, double door type, suitable for fixing MCB,s, TPN with 200 Amps rated bus bar, 4 way, 240 volts complete all as specified and directed.
S&F MCB 63 Amps, TPN, 230 Volts complete all as specified and directed.
S&F MCB 6 to 32 Amps, single pole, 230 Volts complete all as specified and directed.
S&F 2nd class hard wood rectangular block open recessed of size 45x30x5 cm depth with 3mm thick hylum/Bakelite sheet on top grouted with 4 Nos bolts for DB complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 35 sqmm 3.5 core laid in trenches, along poles through pipes etc complete all as specified & as directed. (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection complete all as specified & directed.
M&L dry sand (Tibba sand) and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete.
Supply, installation & testing Geyser (water storage type) of capacity 25 litre, Star rated suitable for 240V, SP, 50 Hz AC supply fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 10mm dia 150mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original all as per manufacturer’s instructions & as directed. Make :- Bajaj / Crompton Greaves / Usha Lexus / Venus / Racold.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on contn...
cont.... including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed.
ARUN ENTERPRISES
shiva construction
M/s Laxmi Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .