Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹76.3 CrQualified | Qualified | |
| 2 | Qualified | Qualified | |
| 3 | Qualified | Qualified | |
| 4 | Qualified | Qualified | |
| 5 | Qualified | Qualified |
Tender Value
Refer Docs
Closing Date
22 Dec 2022, 3:00 pmClosed
Vakati Silpa
Power Grid Corporation of India Limited, Plot No. 2, Saudamini, Sector 29, Gurugram- 122001
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
CC/NT/AIS/DOM/A04/22/00233
Open
Power/Energy Projects/Products
Works
Arasur, Hosur, Raigarh
19 May 2023
16 Nov 2022
26 Dec 2022
16 Nov 2022
22 Dec 2022
16 Nov 2022
25 Nov 2022
Package Name Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
Package Code SS-100 Bought-out
Specification No. SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3, Sch-5, Sch-7 and Bid Form 2nd Envelope.
2 All the cells in Sch-4 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● Fill up applicable rate of Excise Duty. The amount of Excise Duty on the items mentioned as Direct in the mode of transaction in Schedule-1 shall be calculated automatically at the rate mentioned by the bidder here.
● Segregate and fill up the amount on which Sales Tax shall be applicable out of Ex-works supply items mentioned as direct in the mode of transaction in Schedule-1. Applicable Excise Duty on this amount will be calculated automatically at the rate mentioned by the bidder. Further, fill up the rate of applicable Sales Tax. Amount of Sales Tax shall be automatically calculated on the amount mentioned by the bidder as subjected to Sales Tax plus applicable Excise Duty at the rate mentioned by the Bidder.
● Difference of total amount quoted by the bidder as Direct Transaction and the amount mentioned by him subjected to Sales Tax shall be considered as the amount on which VAT shall become applicable and the same shall be calculated & displayed automatically. Applicable Excise Duty on this amount at the rate mentioned by the bidder shall also be calculated & displayed automatically. Fill up the rate of applicable VAT. The amount of VAT shall be calculated automatically on the amount considered to be subjected to VAT plus applicable Excise Duty at the rate mentioned by the bidder here.
● Amount as per details filled up by the bidder in the work sheets Entry Tax, Octroi and other Taxes & Duties shall be displayed in this work sheet Sch-5 but will not be added to the grand total and shall be considered as applicable.
● Click at the links to go to the work sheets Entry Tax, Octroi and other Taxes & Duties one by one.
● Fill the description, amount and rate of applicable Entry Tax. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Fill the description, amount and rate of applicable Octroi. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
Other Taxes & Duties :
● Fill the description, amount and rate of applicable Other Taxes & Duties. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid form 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Sole Bidder 1
JV (Joint Venture) 1
Enter following details of the bidder 2
Specify type of Bidder [Select from drop down menu] Sole Bidder 1 0
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule-1
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : Contract Services 0
Name : Power Grid Corporation of India Ltd., 0
Address : "Saudamini", Plot No.-2 JOINT VENTURE OF 0 & 0 …….. …….. …….. …….. …….. ……..
Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted.
(All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Description Material Code HSN Code Whether HSN in column ‘6’ is confirmed. If not indicate applicable the HSN code # Rate of GST applicable ( in %) Whether rate of GST in column ‘8’ is confirmed. If not indicate applicable rate of GST # Item Description Unit Qty. Unit Ex-Works Price (excluding GST) Total Ex-Works Price (excluding GST)
A BOQ RAIGARH EXTN 3rd ICT Rounded off UnitPrice Total Corrected Price (excl. GST) GST rate GST @12% GST @18% GST @28% GST amount @12% GST amount @18% GST amount @28%
1 7000020160 130 Erection Hardware for 420 kV I Type S/Y 1000011327 72169990 18 Erection Hardware for 400kV I type layout-Transformer bay as pertechnical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
2 7000020160 140 Erection Hardware for 220 kV DMT Type S 1000011264 72169990 18 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transformer Bay as per technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
3 7000020160 580 400kV Insulator and hardware fittings 1000055987 72169990 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
4 7000020160 540 220kV Insulator and Hardware fittings 1000055980 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 6 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
5 7000020160 550 220kV Insulator and Hardware fittings 1000055983 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 6 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
6 7000020160 560 220kV Insulator and Hardware fittings 1000055975 72169990 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
7 7000020160 570 220kV Insulator and Hardware fittings 1000055977 72169990 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH THROUGH CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
9 7000020160 160 CRP for 420kV Bays with SAS 1000004274 85371000 18 400kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
11 7000020160 180 CRP for 420kV Bays with SAS 1000002165 85371000 18 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
12 7000020160 190 CRP for 420kV Bays with SAS 1000002146 85371000 18 Augmentation of existing 400kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
14 7000020160 210 CRP for 220kV Bays with SAS 1000001170 85371000 18 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
15 7000020160 220 CRP for 220kV Bays with SAS 1000001167 85371000 18 Augmentation of existing 220kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
16 7000020160 230 SAS-AUG 1000003409 85371000 18 Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
17 7000020160 240 SAS-AUG 1000001333 85371000 18 Augmentation of Substation automation System for 220kV bay as perTechnical Specification EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
22 7000020160 290 POWER & CONTROL CABLE 1000031985 85446020 18 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
30 7000020160 370 FIRE FIGHTING SYSTEM 1000055456 84248990 18 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING ANDACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 400KV, 3-PHASEAUTOTRANSFORMER SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
31 7000020160 380 ILLUMINATION SYSTEM 1000014547 85371000 18 Lighting Panel type ACP-2 as per technical specification EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
32 7000020160 390 ILLUMINATION SYSTEM 1000001894 94059900 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
33 7000020160 400 ILLUMINATION SYSTEM 1000038387 94051090 18 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 10 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
34 7000020160 410 ILLUMINATION SYSTEM 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 20 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
35 7000020160 630 220kV Equipment Support STRUCTURES 1000017565 73045930 18 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV highBPI including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
36 7000020160 640 220kV Equipment Support STRUCTURES 1000020190 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
37 7000020160 650 220kV Equipment Support STRUCTURES 1000020189 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV ISOLATOR including nuts, bolts, all type of washers, packplates,step bolts and gusset plates excluding foundation bolts EA 4 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
38 7000020160 660 220kV Equipment Support STRUCTURES 1000020187 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
39 7000020160 670 220kV Equipment Support STRUCTURES 1000017562 73045930 18 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 9 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
40 7000020160 680 400kV Equipment Support STRUCTURES 1000020194 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
41 7000020160 690 400kV Equipment Support STRUCTURES 1000017567 73045930 18 Standard Pipe Structure for 400kV BPI (excluding wave trap) EA 5 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
42 7000020160 700 400kV Equipment Support STRUCTURES 1000020192 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
43 7000020160 710 400kV Equipment Support STRUCTURES 1000020195 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
B 500MVA 400/230kV 4th ICT at Arasur
44 7000019713 10 Main Equipment 1000013986 85049010 18 Insulating Oil for 500MVA, 400KV/220/33 KV, 3-phase Autotransformer SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
46 7000019713 30 Main Equipment 1000030470 85049010 18 Digital RTCC Panel consist of digital RTCC relays as per technicalspecification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
47 7000019713 40 Mandatory Spares for 500MVA Transformer 1000016676 85049010 18 Oil cooler pump with motor for 400kV Transformer SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
48 7000019713 50 Mandatory Spares for 500MVA Transformer 1000009731 85049010 18 Cooler fan with motor for 400kV Transformer EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
49 7000019713 60 Mandatory Spares for 500MVA Transformer 1000007922 85049010 18 Buchholz Relay (Main Tank) complete with float and contacts forTransformer SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
50 7000019713 70 Mandatory Spares for 500MVA Transformer 1000028280 85049010 18 Magnetic Oil Level Gauge EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
51 7000019713 80 Mandatory Spares for 500MVA Transformer 1000009586 85049010 18 Starters, contactors, switches and relays for electrical controlpanels of 400kV T/F (one set of each type) SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
52 7000019713 90 Mandatory Spares for 500MVA Transformer 1000016694 85049010 18 Oil flow indicator for 400kV T/F with flow switch SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
53 7000019713 100 Mandatory Spares for 500MVA Transformer 1000032089 85049010 18 SPARES INSULATING OIL TO BE HANDED OVER TO OWNER AFTER COMMISSIONING KL 5 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
54 7000019713 110 Mandatory Spares for 500MVA Transformer 1000002071 85049010 18 36kV, 2000A Bushing with metal parts andgaskets for Transformer EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
55 7000019713 120 Mandatory Spares for 500MVA Transformer 1000028774 85049010 18 Local winding temperature indicator (WTI) with contact EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
56 7000019713 130 Mandatory Spares for 500MVA Transformer 1000026245 85049010 18 OTI complete with contacts & sensing device SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
57 7000019713 140 Mandatory Spares for 500MVA Transformer 1000004920 85049010 18 52kV, 3150A Bushing with metal parts andgaskets EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
58 7000019713 150 Mandatory Spares for 500MVA Transformer 1000004384 85049010 18 420kV, 1250A Bushing with metal partsand gaskets EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
59 7000019713 160 Mandatory Spares for 500MVA Transformer 1000001698 85049010 18 245kV, 2000A Bushing with metal partsand gaskets EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
C Extn of 400/230kV Arasur SS for 4th ICT
60 7000019713 180 Erection Hardware for 420 kV I Type S/Y 1000011320 72169990 18 Erection Hardware for 400kV I type layout-Any feeder Extn. on existinghalf dia. as per technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
61 7000019713 190 420kV Insulator and Hardware 1000055987 72169990 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
62 7000019713 200 Erection Hardware for 220 kV DMT Type S 1000011257 72169990 18 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus work (three Bay) as per technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
63 7000019713 210 Erection Hardware for 220 kV DMT Type S 1000011264 72169990 18 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transformer Bay as per technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
64 7000019713 220 220kV Insulator and Hardware 1000055983 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
65 7000019713 230 220kV Insulator and Hardware 1000055981 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
66 7000019713 240 220kV Insulator and Hardware 1000055980 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
67 7000019713 250 220kV Insulator and Hardware 1000055978 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
68 7000019713 260 220kV Insulator and Hardware 1000055977 72169990 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH THROUGH CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
69 7000019713 270 220kV Insulator and Hardware 1000055975 72169990 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
71 7000019713 290 CRP for 420kV Bays with SAS 1000055446 85371000 18 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
72 7000019713 300 CRP for 420kV Bays with SAS 1000004274 85371000 18 400kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
73 7000019713 310 CRP for 220kV Bays with SAS 1000055443 85371000 18 220KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
74 7000019713 320 CRP for 220kV Bays with SAS 1000001167 85371000 18 Augmentation of existing 220kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
75 7000019713 330 VMS 1000030433 85287390 18 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
76 7000019713 340 220kV EHV Cable & Associated Equipments 1000028468 85446020 18 220 KV OUTDOOR TERMINATION KIT SUITABLE FOR 220 KV XLPECABLE SET 8 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
77 7000019713 350 220kV EHV Cable & Associated Equipments 1000032030 85446090 18 220KV HV POWER CABLE ALONG WITH ACCESSORIES KM 1.2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
89 7000019713 470 AIR CONDITIONING & VENTILATION SYSTEM 1000006284 84151090 28 Air conditioning system for Switchyard Panel Room of 6m length SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.28 0.00 0.00 0.28 0 0 0
90 7000019713 480 FIRE FIGHTING SYSTEM 1000055456 84248990 18 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING ANDACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 400KV, 3-PHASEAUTOTRANSFORMER SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
91 7000019713 490 FIRE FIGHTING SYSTEM 1000012018 85311020 18 Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
92 7000019713 500 FIRE FIGHTING SYSTEM 1000012022 84241000 18 4.5 kg CO2 type Portable Fire extinguisher EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
93 7000019713 510 ILLUMINATION SYSTEM 1000013795 94059900 18 Illumination System for switchyard panel room of 6 m length LS 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
94 7000019713 520 ILLUMINATION SYSTEM 1000038385 94059900 18 FIRE WALL MOUNTED LED LUMINARIE TYPE FL-2 (250W) EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
95 7000019713 530 ILLUMINATION SYSTEM 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
96 7000019713 540 ILLUMINATION SYSTEM 1000038387 94051090 18 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 20 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
97 7000019713 550 ILLUMINATION SYSTEM 1000001894 94059900 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
98 7000019713 560 ILLUMINATION SYSTEM 1000014548 94059900 18 Lighting Panel type ACP-3 as per technical specification EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
99 7000019713 570 400kV Equipment support structures 1000017567 73045930 18 Standard Pipe Structure for 400kV BPI (excluding wave trap) EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
100 7000019713 580 400kV Equipment support structures 1000020192 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
101 7000019713 590 400kV Equipment support structures 1000020194 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
102 7000019713 600 400kV Equipment support structures 1000020195 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
103 7000019713 610 220 kV Towers 1000020099 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CCincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
104 7000019713 620 220 kV Towers 1000020103 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CTAincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
105 7000019713 630 220 kV Towers 1000020104 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CTBincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
106 7000019713 640 220 kV Towers 1000020105 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CTCincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
107 7000019713 650 220 kV Towers 1000020109 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CTGincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
108 7000019713 660 220 kV Towers 1000020110 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CTHincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
109 7000019713 670 220 kV Towers 1000020086 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Gantry B1including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
110 7000019713 680 220 kV Towers 1000020088 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Gantry BG1including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 5 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
111 7000019713 690 220 kV Towers 1000063971 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CTA (W/OPeak)including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
112 7000019713 700 220kV Equipment support structures 1000017565 73045930 18 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV highBPI including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
113 7000019713 710 220kV Equipment support structures 1000017562 73045930 18 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 12 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
114 7000019713 720 220kV Equipment support structures 1000020187 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
115 7000019713 730 220kV Equipment support structures 1000020189 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV ISOLATOR including nuts, bolts, all type of washers, packplates,step bolts and gusset plates excluding foundation bolts EA 4 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
116 7000019713 740 220kV Equipment support structures 1000020190 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
117 7000019713 940 Mandatory spare LOT 1000032289 84819090 18 SPARES FOFIRE PROTECTION SYSTEM SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
118 7000019713 950 Mandatory spare LOT 1000019912 85371000 18 Relay & protection Panels (with automation) LS 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
119 7000019713 960 Mandatory spare LOT 1000019927 85389000 18 Spares-Substation Automation System LS 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
120 7000019713 970 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000015954 73082011 18 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 1.5 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
121 7000019713 980 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000011713 73082011 18 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 0.1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
122 7000019713 990 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012373 73082011 18 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 0.2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
123 7000019713 1000 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012366 73082011 18 Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 324 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
124 7000019713 1020 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012368 73082011 18 Fabrication, galvanising and supply of 40mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 16 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
125 7000019713 1030 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012369 73082011 18 Fabrication, galvanising and supply of 56mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 96 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
126 7000019713 1060 SAS 1000001333 85371000 18 Augmentation of Substation automation System for 220kV bay as perTechnical Specification EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
D 500MVA 400/230kV 4th ICT at Hosur
127 7000019714 870 Main Equipment 1000013986 85049010 18 Insulating Oil for 500MVA, 400KV/220/33 KV, 3-phase Autotransformer SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
129 7000019714 890 Main Equipment 1000030470 85049010 18 Digital RTCC Panel consist of digital RTCC relays as per technicalspecification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
130 7000019714 900 Mandatory Spares for 500MVA Transformer 1000016676 85049010 18 Oil cooler pump with motor for 400kV Transformer SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
131 7000019714 910 Mandatory Spares for 500MVA Transformer 1000009731 85049010 18 Cooler fan with motor for 400kV Transformer EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
132 7000019714 920 Mandatory Spares for 500MVA Transformer 1000007922 85049010 18 Buchholz Relay (Main Tank) complete with float and contacts forTransformer SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
133 7000019714 930 Mandatory Spares for 500MVA Transformer 1000028280 85049010 18 Magnetic Oil Level Gauge EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
134 7000019714 940 Mandatory Spares for 500MVA Transformer 1000009586 85049010 18 Starters, contactors, switches and relays for electrical controlpanels of 400kV T/F (one set of each type) SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
135 7000019714 950 Mandatory Spares for 500MVA Transformer 1000016694 85049010 18 Oil flow indicator for 400kV T/F with flow switch SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
136 7000019714 960 Mandatory Spares for 500MVA Transformer 1000032089 85049010 18 SPARES INSULATING OIL TO BE HANDED OVER TO OWNER AFTER COMMISSIONING KL 5 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
137 7000019714 970 Mandatory Spares for 500MVA Transformer 1000002071 85049010 18 36kV, 2000A Bushing with metal parts andgaskets for Transformer EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
138 7000019714 980 Mandatory Spares for 500MVA Transformer 1000028774 85049010 18 Local winding temperature indicator (WTI) with contact EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
139 7000019714 990 Mandatory Spares for 500MVA Transformer 1000026245 85049010 18 OTI complete with contacts & sensing device SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
140 7000019714 1000 Mandatory Spares for 500MVA Transformer 1000004920 85049010 18 52kV, 3150A Bushing with metal parts andgaskets EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
141 7000019714 1010 Mandatory Spares for 500MVA Transformer 1000004384 85049010 18 420kV, 1250A Bushing with metal partsand gaskets EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
142 7000019714 1020 Mandatory Spares for 500MVA Transformer 1000001698 85049010 18 245kV, 2000A Bushing with metal partsand gaskets EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
E Extn of 400/230kV Hosur SS for 4th ICT
143 7000019714 10 Erection Hardware for 420 kV I Type S/Y 1000011320 72169990 18 Erection Hardware for 400kV I type layout-Any feeder Extn. on existinghalf dia. as per technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
144 7000019714 20 Erection Hardware for 420 kV I Type S/Y 1000011325 72169990 18 Erection Hardware for 400kV I type layout-Re-oriented Transformer bayas per technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
145 7000019714 30 420kV Insulator and Hardware 1000055987 72169990 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
146 7000019714 40 Erection Hardware for 220 kV DMT Type S 1000011256 72169990 18 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus work (two Bay) as per technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
147 7000019714 50 Erection Hardware for 220 kV DMT Type S 1000011264 72169990 18 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transformer Bay as per technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
148 7000019714 60 220kV Insulator and Hardware 1000055983 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 12 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
149 7000019714 70 220kV Insulator and Hardware 1000055981 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
150 7000019714 80 220kV Insulator and Hardware 1000055980 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 12 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
151 7000019714 90 220kV Insulator and Hardware 1000055978 72169990 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
152 7000019714 100 220kV Insulator and Hardware 1000055977 72169990 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH THROUGH CLAMP SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
153 7000019714 110 220kV Insulator and Hardware 1000055975 72169990 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 6 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
155 7000019714 130 CSD 1000009713 85389000 18 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
156 7000019714 140 CRP for conventianal 420kV Bays 1000055445 85371000 18 400KV CIRCUIT BREAKER RELAY PANEL EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
157 7000019714 150 CRP for conventianal 420kV Bays 1000004273 85371000 18 400kV Transformer Protection Panel (For both HV & MV side) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
158 7000019714 160 CRP for conventianal 420kV Bays 1000002167 85371000 18 Augmentation of existing 400kV Control Panel (Bus Scheme as per SLD) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
160 7000019714 180 CRP for CONV. 220kV Bays 1000001342 85371000 18 Augmentation of existing Simplex Control Panel for 220kV (Bus schemeas per SLD) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
161 7000019714 190 VMS 1000030433 85287390 18 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
174 7000019714 320 FIRE FIGHTING SYSTEM 1000055456 84248990 18 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING ANDACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 400KV, 3-PHASEAUTOTRANSFORMER SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
175 7000019714 330 ILLUMINATION SYSTEM 1000014548 94059900 18 Lighting Panel type ACP-3 as per technical specification EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
176 7000019714 340 ILLUMINATION SYSTEM 1000001894 94059900 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
177 7000019714 350 ILLUMINATION SYSTEM 1000038387 94051090 18 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 20 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
178 7000019714 360 ILLUMINATION SYSTEM 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 15 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
179 7000019714 370 ILLUMINATION SYSTEM 1000038385 94059900 18 FIRE WALL MOUNTED LED LUMINARIE TYPE FL-2 (250W) EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
180 7000019714 380 400kV Equipment support structures 1000020195 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
181 7000019714 390 400kV Equipment support structures 1000020194 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
182 7000019714 400 400kV Equipment support structures 1000020192 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
183 7000019714 410 400kV Equipment support structures 1000017567 73045930 18 Standard Pipe Structure for 400kV BPI (excluding wave trap) EA 9 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
184 7000019714 420 220 kV Towers 1000020097 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CAincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
185 7000019714 430 220 kV Towers 1000020092 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower (w/opeak) CA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
186 7000019714 440 220 kV Towers 1000020098 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CBincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
187 7000019714 450 220 kV Towers 1000020099 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CCincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
188 7000019714 460 220 kV Towers 1000020100 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CDincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
189 7000019714 470 220 kV Towers 1000020110 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CTHincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
190 7000019714 480 220 kV Towers 1000020111 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Tower CTIincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
191 7000019714 490 220 kV Towers 1000020086 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Gantry B1including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 4 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
192 7000019714 500 220 kV Towers 1000020087 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Gantry BAincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
193 7000019714 510 220 kV Towers 1000020089 73082011 18 Fabrication, galvanising and supply of Standard 220 kV Gantry BGAincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
194 7000019714 520 220 kV Towers 1000020090 73082011 18 Fabrication, galvanising and supply of Std LM (40m) includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
195 7000019714 530 220kV Equipment support structures 1000017565 73045930 18 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV highBPI including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
196 7000019714 540 220kV Equipment support structures 1000017562 73045930 18 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 12 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
197 7000019714 550 220kV Equipment support structures 1000020187 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
198 7000019714 560 220kV Equipment support structures 1000020189 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV ISOLATOR including nuts, bolts, all type of washers, packplates,step bolts and gusset plates excluding foundation bolts EA 4 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
199 7000019714 570 220kV Equipment support structures 1000020190 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
200 7000019714 750 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000015952 73082011 18 Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 2 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
201 7000019714 760 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000011713 73082011 18 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 0.15 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
202 7000019714 770 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012373 73082011 18 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 0.15 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
203 7000019714 780 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012366 73082011 18 Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 316 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
204 7000019714 800 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012368 73082011 18 Fabrication, galvanising and supply of 40mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 96 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
205 7000019714 810 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012369 73082011 18 Fabrication, galvanising and supply of 56mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 80 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
206 7000019714 840 Mandatory spare LOT 1000032289 84819090 18 SPARES FOFIRE PROTECTION SYSTEM SET 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
207 7000019714 850 Mandatory spare LOT 1000019912 85371000 18 Relay & protection Panels (with automation) LS 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
208 7000019714 860 Mandatory spare LOT 1000019927 85389000 18 Spares-Substation Automation System LS 1 INCLUDED 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.18 0.00 0 0 0
Total Type Test charges as per Schedule-7 Not Applicable Total Corrected Price (excl. GST) GST amount @12% GST amount @18% GST amount @28%
Total Ex-Works Price including Type Test charges 0.00
# In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date Printed Name
Place Designation
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule - 2
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Local Transportation, In-transit Insurance, Loading and Unloading
(All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Description Material Code Description Unit Quantity Unit Freight, In-transit Insurance, loading & Unloading Charges Total Freight, In-transit Insurance, loading & Unloading Charges
A BOQ RAIGARH EXTN 3rd ICT Rounded off UnitPrice Total Corrected Price (excl. GST)
1 7000020160 130 Erection Hardware for 420 kV I Type S/Y 1000011327 Erection Hardware for 400kV I type layout-Transformer bay as pertechnical specification SET 1 INCLUDED 0.00 0.00
2 7000020160 140 Erection Hardware for 220 kV DMT Type S 1000011264 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transformer Bay as per technical specification SET 1 INCLUDED 0.00 0.00
3 7000020160 580 400kV Insulator and hardware fittings 1000055987 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0.00 0.00
4 7000020160 540 220kV Insulator and Hardware fittings 1000055980 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 6 INCLUDED 0.00 0.00
5 7000020160 550 220kV Insulator and Hardware fittings 1000055983 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 6 INCLUDED 0.00 0.00
6 7000020160 560 220kV Insulator and Hardware fittings 1000055975 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED
7 7000020160 570 220kV Insulator and Hardware fittings 1000055977 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH THROUGH CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED
8 7000020160 150 Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 1 INCLUDED
9 7000020160 160 CRP for 420kV Bays with SAS 1000004274 400kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 1 INCLUDED
10 7000020160 170 CRP for 420kV Bays with SAS 1000025391 Relay Test kit EA 1 INCLUDED
11 7000020160 180 CRP for 420kV Bays with SAS 1000002165 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 1 INCLUDED
12 7000020160 190 CRP for 420kV Bays with SAS 1000002146 Augmentation of existing 400kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED
13 7000020160 200 CRP for 420kV Bays with SAS 1000028349 DIGITAL RTCC PANEL SET 1 INCLUDED
14 7000020160 210 CRP for 220kV Bays with SAS 1000001170 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 1 INCLUDED
15 7000020160 220 CRP for 220kV Bays with SAS 1000001167 Augmentation of existing 220kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED
16 7000020160 230 SAS-AUG 1000003409 Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 1 INCLUDED
17 7000020160 240 SAS-AUG 1000001333 Augmentation of Substation automation System for 220kV bay as perTechnical Specification EA 1 INCLUDED
18 7000020160 250 POWER & CONTROL CABLE 1000031887 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 1 INCLUDED
19 7000020160 260 POWER & CONTROL CABLE 1000031987 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 10 INCLUDED
20 7000020160 270 POWER & CONTROL CABLE 1000031964 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 2.5 INCLUDED
21 7000020160 280 POWER & CONTROL CABLE 1000031943 1.1KV GRADE 2CX6 SQMM (PVC) POWER CABLE KM 1.5 INCLUDED
22 7000020160 290 POWER & CONTROL CABLE 1000031985 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 1 INCLUDED
23 7000020160 300 POWER & CONTROL CABLE 1000031976 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 3.5 INCLUDED
24 7000020160 310 POWER & CONTROL CABLE 1000056264 1.1KV GRADE 19CX1.5 SQMM CONTROL CABLE KM 2 INCLUDED
25 7000020160 320 POWER & CONTROL CABLE 1000031957 1.1KV GRADE 3.5CX70 SQMM (PVC) POWER CABLE KM 2 INCLUDED
26 7000020160 330 POWER & CONTROL CABLE 1000031993 1.1KV GRADE 7CX2.5 SQMM CONTROL CABLE KM 1.5 INCLUDED
27 7000020160 340 POWER & CONTROL CABLE 1000031904 1.1KV GRADE 14CX2.5 SQMM CONTROL CABLE KM 1 INCLUDED
28 7000020160 350 POWER & CONTROL CABLE 1000031927 1.1KV GRADE 27CX2.5 SQMM CONTROL CABLE KM 1 INCLUDED
29 7000020160 360 POWER & CONTROL CABLE 1000032050 4PAIR, 0.5SQMM SCREENED CABLE KM 4 INCLUDED
30 7000020160 370 FIRE FIGHTING SYSTEM 1000055456 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING ANDACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 400KV, 3-PHASEAUTOTRANSFORMER SET 1 INCLUDED
31 7000020160 380 ILLUMINATION SYSTEM 1000014547 Lighting Panel type ACP-2 as per technical specification EA 2 INCLUDED
32 7000020160 390 ILLUMINATION SYSTEM 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED
33 7000020160 400 ILLUMINATION SYSTEM 1000038387 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 10 INCLUDED
34 7000020160 410 ILLUMINATION SYSTEM 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 20 INCLUDED
35 7000020160 630 220kV Equipment Support STRUCTURES 1000017565 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV highBPI including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts EA 3 INCLUDED
36 7000020160 640 220kV Equipment Support STRUCTURES 1000020190 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED
37 7000020160 650 220kV Equipment Support STRUCTURES 1000020189 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV ISOLATOR including nuts, bolts, all type of washers, packplates,step bolts and gusset plates excluding foundation bolts EA 4 INCLUDED
38 7000020160 660 220kV Equipment Support STRUCTURES 1000020187 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED
39 7000020160 670 220kV Equipment Support STRUCTURES 1000017562 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 9 INCLUDED
40 7000020160 680 400kV Equipment Support STRUCTURES 1000020194 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED
41 7000020160 690 400kV Equipment Support STRUCTURES 1000017567 Standard Pipe Structure for 400kV BPI (excluding wave trap) EA 5 INCLUDED
42 7000020160 700 400kV Equipment Support STRUCTURES 1000020192 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 3 INCLUDED
43 7000020160 710 400kV Equipment Support STRUCTURES 1000020195 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 3 INCLUDED
B 500MVA 400/230kV 4th ICT at Arasur
44 7000019713 10 Main Equipment 1000013986 Insulating Oil for 500MVA, 400KV/220/33 KV, 3-phase Autotransformer SET 1 INCLUDED
45 7000019713 20 Main Equipment 1000028101 500MVA, 400KV/230/33 KV, 3-phase Autotransformer EA 1 INCLUDED
46 7000019713 30 Main Equipment 1000030470 Digital RTCC Panel consist of digital RTCC relays as per technicalspecification SET 1 INCLUDED
47 7000019713 40 Mandatory Spares for 500MVA Transformer 1000016676 Oil cooler pump with motor for 400kV Transformer SET 1 INCLUDED
48 7000019713 50 Mandatory Spares for 500MVA Transformer 1000009731 Cooler fan with motor for 400kV Transformer EA 1 INCLUDED
49 7000019713 60 Mandatory Spares for 500MVA Transformer 1000007922 Buchholz Relay (Main Tank) complete with float and contacts forTransformer SET 1 INCLUDED
50 7000019713 70 Mandatory Spares for 500MVA Transformer 1000028280 Magnetic Oil Level Gauge EA 1 INCLUDED
51 7000019713 80 Mandatory Spares for 500MVA Transformer 1000009586 Starters, contactors, switches and relays for electrical controlpanels of 400kV T/F (one set of each type) SET 1 INCLUDED
52 7000019713 90 Mandatory Spares for 500MVA Transformer 1000016694 Oil flow indicator for 400kV T/F with flow switch SET 1 INCLUDED
53 7000019713 100 Mandatory Spares for 500MVA Transformer 1000032089 SPARES INSULATING OIL TO BE HANDED OVER TO OWNER AFTER COMMISSIONING KL 5 INCLUDED
54 7000019713 110 Mandatory Spares for 500MVA Transformer 1000002071 36kV, 2000A Bushing with metal parts andgaskets for Transformer EA 1 INCLUDED
55 7000019713 120 Mandatory Spares for 500MVA Transformer 1000028774 Local winding temperature indicator (WTI) with contact EA 1 INCLUDED
56 7000019713 130 Mandatory Spares for 500MVA Transformer 1000026245 OTI complete with contacts & sensing device SET 1 INCLUDED
57 7000019713 140 Mandatory Spares for 500MVA Transformer 1000004920 52kV, 3150A Bushing with metal parts andgaskets EA 1 INCLUDED
58 7000019713 150 Mandatory Spares for 500MVA Transformer 1000004384 420kV, 1250A Bushing with metal partsand gaskets EA 1 INCLUDED
59 7000019713 160 Mandatory Spares for 500MVA Transformer 1000001698 245kV, 2000A Bushing with metal partsand gaskets EA 1 INCLUDED
C Extn of 400/230kV Arasur SS for 4th ICT
60 7000019713 180 Erection Hardware for 420 kV I Type S/Y 1000011320 Erection Hardware for 400kV I type layout-Any feeder Extn. on existinghalf dia. as per technical specification SET 1 INCLUDED
61 7000019713 190 420kV Insulator and Hardware 1000055987 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED
62 7000019713 200 Erection Hardware for 220 kV DMT Type S 1000011257 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus work (three Bay) as per technical specification SET 1 INCLUDED
63 7000019713 210 Erection Hardware for 220 kV DMT Type S 1000011264 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transformer Bay as per technical specification SET 1 INCLUDED
64 7000019713 220 220kV Insulator and Hardware 1000055983 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED
65 7000019713 230 220kV Insulator and Hardware 1000055981 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED
66 7000019713 240 220kV Insulator and Hardware 1000055980 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED
67 7000019713 250 220kV Insulator and Hardware 1000055978 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED
68 7000019713 260 220kV Insulator and Hardware 1000055977 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH THROUGH CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED
69 7000019713 270 220kV Insulator and Hardware 1000055975 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED
70 7000019713 280 Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 0.5 INCLUDED
71 7000019713 290 CRP for 420kV Bays with SAS 1000055446 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 1 INCLUDED
72 7000019713 300 CRP for 420kV Bays with SAS 1000004274 400kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 1 INCLUDED
73 7000019713 310 CRP for 220kV Bays with SAS 1000055443 220KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 1 INCLUDED
74 7000019713 320 CRP for 220kV Bays with SAS 1000001167 Augmentation of existing 220kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED
75 7000019713 330 VMS 1000030433 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 3 INCLUDED
76 7000019713 340 220kV EHV Cable & Associated Equipments 1000028468 220 KV OUTDOOR TERMINATION KIT SUITABLE FOR 220 KV XLPECABLE SET 8 INCLUDED
77 7000019713 350 220kV EHV Cable & Associated Equipments 1000032030 220KV HV POWER CABLE ALONG WITH ACCESSORIES KM 1.2 INCLUDED
78 7000019713 360 POWER & CONTROL CABLE 1000032050 4PAIR, 0.5SQMM SCREENED CABLE KM 0.1 INCLUDED
79 7000019713 370 POWER & CONTROL CABLE 1000056265 1.1KV GRADE 27CX1.5 SQMM CONTROL CABLE KM 1.1 INCLUDED
80 7000019713 380 POWER & CONTROL CABLE 1000056264 1.1KV GRADE 19CX1.5 SQMM CONTROL CABLE KM 1 INCLUDED
81 7000019713 390 POWER & CONTROL CABLE 1000031887 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 4.3 INCLUDED
82 7000019713 400 POWER & CONTROL CABLE 1000031987 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 7.4 INCLUDED
83 7000019713 410 POWER & CONTROL CABLE 1000031964 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 2.5 INCLUDED
84 7000019713 420 POWER & CONTROL CABLE 1000031943 1.1KV GRADE 2CX6 SQMM (PVC) POWER CABLE KM 0.8 INCLUDED
85 7000019713 430 POWER & CONTROL CABLE 1000031985 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 0.8 INCLUDED
86 7000019713 440 POWER & CONTROL CABLE 1000031976 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 1 INCLUDED
87 7000019713 450 POWER & CONTROL CABLE 1000031957 1.1KV GRADE 3.5CX70 SQMM (PVC) POWER CABLE KM 1 INCLUDED
88 7000019713 460 POWER & CONTROL CABLE 1000031951 1.1KV GRADE 3.5CX300 SQMM (XLPE) POWER CABLE KM 0.5 INCLUDED
89 7000019713 470 AIR CONDITIONING & VENTILATION SYSTEM 1000006284 Air conditioning system for Switchyard Panel Room of 6m length SET 1 INCLUDED
90 7000019713 480 FIRE FIGHTING SYSTEM 1000055456 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING ANDACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 400KV, 3-PHASEAUTOTRANSFORMER SET 1 INCLUDED
91 7000019713 490 FIRE FIGHTING SYSTEM 1000012018 Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 1 INCLUDED
92 7000019713 500 FIRE FIGHTING SYSTEM 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 1 INCLUDED
93 7000019713 510 ILLUMINATION SYSTEM 1000013795 Illumination System for switchyard panel room of 6 m length LS 1 INCLUDED
94 7000019713 520 ILLUMINATION SYSTEM 1000038385 FIRE WALL MOUNTED LED LUMINARIE TYPE FL-2 (250W) EA 2 INCLUDED
95 7000019713 530 ILLUMINATION SYSTEM 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED
96 7000019713 540 ILLUMINATION SYSTEM 1000038387 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 20 INCLUDED
97 7000019713 550 ILLUMINATION SYSTEM 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED
98 7000019713 560 ILLUMINATION SYSTEM 1000014548 Lighting Panel type ACP-3 as per technical specification EA 3 INCLUDED
99 7000019713 570 400kV Equipment support structures 1000017567 Standard Pipe Structure for 400kV BPI (excluding wave trap) EA 3 INCLUDED
100 7000019713 580 400kV Equipment support structures 1000020192 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 3 INCLUDED
101 7000019713 590 400kV Equipment support structures 1000020194 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED
102 7000019713 600 400kV Equipment support structures 1000020195 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 3 INCLUDED
103 7000019713 610 220 kV Towers 1000020099 Fabrication, galvanising and supply of Standard 220 kV Tower CCincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED
104 7000019713 620 220 kV Towers 1000020103 Fabrication, galvanising and supply of Standard 220 kV Tower CTAincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED
105 7000019713 630 220 kV Towers 1000020104 Fabrication, galvanising and supply of Standard 220 kV Tower CTBincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED
106 7000019713 640 220 kV Towers 1000020105 Fabrication, galvanising and supply of Standard 220 kV Tower CTCincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED
107 7000019713 650 220 kV Towers 1000020109 Fabrication, galvanising and supply of Standard 220 kV Tower CTGincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED
108 7000019713 660 220 kV Towers 1000020110 Fabrication, galvanising and supply of Standard 220 kV Tower CTHincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED
109 7000019713 670 220 kV Towers 1000020086 Fabrication, galvanising and supply of Standard 220 kV Gantry B1including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 3 INCLUDED
110 7000019713 680 220 kV Towers 1000020088 Fabrication, galvanising and supply of Standard 220 kV Gantry BG1including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 5 INCLUDED
111 7000019713 690 220 kV Towers 1000063971 Fabrication, galvanising and supply of Standard 220 kV Tower CTA (W/OPeak)including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts EA 2 INCLUDED
112 7000019713 700 220kV Equipment support structures 1000017565 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV highBPI including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts EA 3 INCLUDED
113 7000019713 710 220kV Equipment support structures 1000017562 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 12 INCLUDED
114 7000019713 720 220kV Equipment support structures 1000020187 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED
115 7000019713 730 220kV Equipment support structures 1000020189 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV ISOLATOR including nuts, bolts, all type of washers, packplates,step bolts and gusset plates excluding foundation bolts EA 4 INCLUDED
116 7000019713 740 220kV Equipment support structures 1000020190 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED
117 7000019713 940 Mandatory spare LOT 1000032289 SPARES FOFIRE PROTECTION SYSTEM SET 1 INCLUDED
118 7000019713 950 Mandatory spare LOT 1000019912 Relay & protection Panels (with automation) LS 1 INCLUDED
119 7000019713 960 Mandatory spare LOT 1000019927 Spares-Substation Automation System LS 1 INCLUDED
120 7000019713 970 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 1.5 INCLUDED
121 7000019713 980 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 0.1 INCLUDED
122 7000019713 990 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 0.2 INCLUDED
123 7000019713 1000 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012366 Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 324 INCLUDED
124 7000019713 1020 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012368 Fabrication, galvanising and supply of 40mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 16 INCLUDED
125 7000019713 1030 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012369 Fabrication, galvanising and supply of 56mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 96 INCLUDED
126 7000019713 1060 SAS 1000001333 Augmentation of Substation automation System for 220kV bay as perTechnical Specification EA 1 INCLUDED
D 500MVA 400/230kV 4th ICT at Hosur
127 7000019714 870 Main Equipment 1000013986 Insulating Oil for 500MVA, 400KV/220/33 KV, 3-phase Autotransformer SET 1 INCLUDED
128 7000019714 880 Main Equipment 1000028101 500MVA, 400KV/230/33 KV, 3-phase Autotransformer EA 1 INCLUDED
129 7000019714 890 Main Equipment 1000030470 Digital RTCC Panel consist of digital RTCC relays as per technicalspecification SET 1 INCLUDED
130 7000019714 900 Mandatory Spares for 500MVA Transformer 1000016676 Oil cooler pump with motor for 400kV Transformer SET 1 INCLUDED
131 7000019714 910 Mandatory Spares for 500MVA Transformer 1000009731 Cooler fan with motor for 400kV Transformer EA 1 INCLUDED
132 7000019714 920 Mandatory Spares for 500MVA Transformer 1000007922 Buchholz Relay (Main Tank) complete with float and contacts forTransformer SET 1 INCLUDED
133 7000019714 930 Mandatory Spares for 500MVA Transformer 1000028280 Magnetic Oil Level Gauge EA 1 INCLUDED
134 7000019714 940 Mandatory Spares for 500MVA Transformer 1000009586 Starters, contactors, switches and relays for electrical controlpanels of 400kV T/F (one set of each type) SET 1 INCLUDED
135 7000019714 950 Mandatory Spares for 500MVA Transformer 1000016694 Oil flow indicator for 400kV T/F with flow switch SET 1 INCLUDED
136 7000019714 960 Mandatory Spares for 500MVA Transformer 1000032089 SPARES INSULATING OIL TO BE HANDED OVER TO OWNER AFTER COMMISSIONING KL 5 INCLUDED
137 7000019714 970 Mandatory Spares for 500MVA Transformer 1000002071 36kV, 2000A Bushing with metal parts andgaskets for Transformer EA 1 INCLUDED
138 7000019714 980 Mandatory Spares for 500MVA Transformer 1000028774 Local winding temperature indicator (WTI) with contact EA 1 INCLUDED
139 7000019714 990 Mandatory Spares for 500MVA Transformer 1000026245 OTI complete with contacts & sensing device SET 1 INCLUDED
140 7000019714 1000 Mandatory Spares for 500MVA Transformer 1000004920 52kV, 3150A Bushing with metal parts andgaskets EA 1 INCLUDED
141 7000019714 1010 Mandatory Spares for 500MVA Transformer 1000004384 420kV, 1250A Bushing with metal partsand gaskets EA 1 INCLUDED
142 7000019714 1020 Mandatory Spares for 500MVA Transformer 1000001698 245kV, 2000A Bushing with metal partsand gaskets EA 1 INCLUDED
E Extn of 400/230kV Hosur SS for 4th ICT
143 7000019714 10 Erection Hardware for 420 kV I Type S/Y 1000011320 Erection Hardware for 400kV I type layout-Any feeder Extn. on existinghalf dia. as per technical specification SET 1 INCLUDED
144 7000019714 20 Erection Hardware for 420 kV I Type S/Y 1000011325 Erection Hardware for 400kV I type layout-Re-oriented Transformer bayas per technical specification SET 1 INCLUDED
145 7000019714 30 420kV Insulator and Hardware 1000055987 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED
146 7000019714 40 Erection Hardware for 220 kV DMT Type S 1000011256 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus work (two Bay) as per technical specification SET 1 INCLUDED
147 7000019714 50 Erection Hardware for 220 kV DMT Type S 1000011264 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transformer Bay as per technical specification SET 1 INCLUDED
148 7000019714 60 220kV Insulator and Hardware 1000055983 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 12 INCLUDED
149 7000019714 70 220kV Insulator and Hardware 1000055981 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHTURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED
150 7000019714 80 220kV Insulator and Hardware 1000055980 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 12 INCLUDED
151 7000019714 90 220kV Insulator and Hardware 1000055978 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED
152 7000019714 100 220kV Insulator and Hardware 1000055977 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH THROUGH CLAMP SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED
153 7000019714 110 220kV Insulator and Hardware 1000055975 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 6 INCLUDED
154 7000019714 120 Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 0.5 INCLUDED
155 7000019714 130 CSD 1000009713 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 1 INCLUDED
156 7000019714 140 CRP for conventianal 420kV Bays 1000055445 400KV CIRCUIT BREAKER RELAY PANEL EA 1 INCLUDED
157 7000019714 150 CRP for conventianal 420kV Bays 1000004273 400kV Transformer Protection Panel (For both HV & MV side) EA 1 INCLUDED
158 7000019714 160 CRP for conventianal 420kV Bays 1000002167 Augmentation of existing 400kV Control Panel (Bus Scheme as per SLD) EA 1 INCLUDED
159 7000019714 170 CRP for CONV. 220kV Bays 1000055442 220KV CIRCUIT BREAKER RELAY PANEL EA 1 INCLUDED
160 7000019714 180 CRP for CONV. 220kV Bays 1000001342 Augmentation of existing Simplex Control Panel for 220kV (Bus schemeas per SLD) EA 1 INCLUDED
161 7000019714 190 VMS 1000030433 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 2 INCLUDED
162 7000019714 200 LT SWITCHGEAR 1000004304 415V ACDB (Extn.) SET 1 INCLUDED
163 7000019714 210 LT SWITCHGEAR 1000001145 220V DCDB (Extn.) SET 1 INCLUDED
164 7000019714 220 POWER & CONTROL CABLE 1000056265 1.1KV GRADE 27CX1.5 SQMM CONTROL CABLE KM 1.1 INCLUDED
165 7000019714 230 POWER & CONTROL CABLE 1000056264 1.1KV GRADE 19CX1.5 SQMM CONTROL CABLE KM 1 INCLUDED
166 7000019714 240 POWER & CONTROL CABLE 1000031887 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 5 INCLUDED
167 7000019714 250 POWER & CONTROL CABLE 1000031987 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 10 INCLUDED
168 7000019714 260 POWER & CONTROL CABLE 1000031964 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 2.5 INCLUDED
169 7000019714 270 POWER & CONTROL CABLE 1000031943 1.1KV GRADE 2CX6 SQMM (PVC) POWER CABLE KM 0.8 INCLUDED
170 7000019714 280 POWER & CONTROL CABLE 1000031985 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 0.8 INCLUDED
171 7000019714 290 POWER & CONTROL CABLE 1000031976 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 1 INCLUDED
172 7000019714 300 POWER & CONTROL CABLE 1000031957 1.1KV GRADE 3.5CX70 SQMM (PVC) POWER CABLE KM 1 INCLUDED
173 7000019714 310 POWER & CONTROL CABLE 1000031951 1.1KV GRADE 3.5CX300 SQMM (XLPE) POWER CABLE KM 0.5 INCLUDED
174 7000019714 320 FIRE FIGHTING SYSTEM 1000055456 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING ANDACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 400KV, 3-PHASEAUTOTRANSFORMER SET 1 INCLUDED
175 7000019714 330 ILLUMINATION SYSTEM 1000014548 Lighting Panel type ACP-3 as per technical specification EA 3 INCLUDED
176 7000019714 340 ILLUMINATION SYSTEM 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED
177 7000019714 350 ILLUMINATION SYSTEM 1000038387 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 20 INCLUDED
178 7000019714 360 ILLUMINATION SYSTEM 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 15 INCLUDED
179 7000019714 370 ILLUMINATION SYSTEM 1000038385 FIRE WALL MOUNTED LED LUMINARIE TYPE FL-2 (250W) EA 2 INCLUDED
180 7000019714 380 400kV Equipment support structures 1000020195 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 3 INCLUDED
181 7000019714 390 400kV Equipment support structures 1000020194 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED
182 7000019714 400 400kV Equipment support structures 1000020192 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 3 INCLUDED
183 7000019714 410 400kV Equipment support structures 1000017567 Standard Pipe Structure for 400kV BPI (excluding wave trap) EA 9 INCLUDED
184 7000019714 420 220 kV Towers 1000020097 Fabrication, galvanising and supply of Standard 220 kV Tower CAincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED
185 7000019714 430 220 kV Towers 1000020092 Fabrication, galvanising and supply of Standard 220 kV Tower (w/opeak) CA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 2 INCLUDED
186 7000019714 440 220 kV Towers 1000020098 Fabrication, galvanising and supply of Standard 220 kV Tower CBincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED
187 7000019714 450 220 kV Towers 1000020099 Fabrication, galvanising and supply of Standard 220 kV Tower CCincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED
188 7000019714 460 220 kV Towers 1000020100 Fabrication, galvanising and supply of Standard 220 kV Tower CDincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED
189 7000019714 470 220 kV Towers 1000020110 Fabrication, galvanising and supply of Standard 220 kV Tower CTHincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED
190 7000019714 480 220 kV Towers 1000020111 Fabrication, galvanising and supply of Standard 220 kV Tower CTIincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED
191 7000019714 490 220 kV Towers 1000020086 Fabrication, galvanising and supply of Standard 220 kV Gantry B1including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 4 INCLUDED
192 7000019714 500 220 kV Towers 1000020087 Fabrication, galvanising and supply of Standard 220 kV Gantry BAincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 INCLUDED
193 7000019714 510 220 kV Towers 1000020089 Fabrication, galvanising and supply of Standard 220 kV Gantry BGAincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 INCLUDED
194 7000019714 520 220 kV Towers 1000020090 Fabrication, galvanising and supply of Std LM (40m) includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 1 INCLUDED
195 7000019714 530 220kV Equipment support structures 1000017565 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV highBPI including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts EA 3 INCLUDED
196 7000019714 540 220kV Equipment support structures 1000017562 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 12 INCLUDED
197 7000019714 550 220kV Equipment support structures 1000020187 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED
198 7000019714 560 220kV Equipment support structures 1000020189 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV ISOLATOR including nuts, bolts, all type of washers, packplates,step bolts and gusset plates excluding foundation bolts EA 4 INCLUDED
199 7000019714 570 220kV Equipment support structures 1000020190 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 3 INCLUDED
200 7000019714 750 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000015952 Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 2 INCLUDED
201 7000019714 760 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 0.15 INCLUDED
202 7000019714 770 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 0.15 INCLUDED
203 7000019714 780 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012366 Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 316 INCLUDED
204 7000019714 800 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012368 Fabrication, galvanising and supply of 40mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 96 INCLUDED
205 7000019714 810 SUPPY OF FDN BOLTS, FASTENERS, LATTICE 1000012369 Fabrication, galvanising and supply of 56mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 80 INCLUDED
206 7000019714 840 Mandatory spare LOT 1000032289 SPARES FOFIRE PROTECTION SYSTEM SET 1 INCLUDED
207 7000019714 850 Mandatory spare LOT 1000019912 Relay & protection Panels (with automation) LS 1 INCLUDED
208 7000019714 860 Mandatory spare LOT 1000019927 Spares-Substation Automation System LS 1 INCLUDED
TOTAL 0.00 0.00
Date Printed Name
Place Designation
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule - 3
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Installation Charges :
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘8’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable (in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit Erection Charges Total Erection Charges GST Before Discount Discount Total Price after discount GST After Discount
A BOQ RAIGARH EXTN 3rd ICT Rounded off UnitPrice Total Corrected Price (excl. GST) GST rate GST Amount
1 7000020160 420 1330 10 Insta. 420kV, 40kA AIS EQUIPMENT 100000263 998736 18 420kV, 3150A, 40kA Circuit Breaker(3-Phase) without closing resistor(with support structure) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
2 7000020160 420 1330 20 Insta. 420kV, 40kA AIS EQUIPMENT 100000271 998736 18 420 kV, 3000A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
3 7000020160 420 1330 30 Insta. 420kV, 40kA AIS EQUIPMENT 100000281 998736 18 420kV, 3150A, 40KA, Isolator (3-phase)(Double Break) with one E/S EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
4 7000020160 420 1330 40 Insta. 420kV, 40kA AIS EQUIPMENT 100000328 998736 18 336kV Surge Arrester (1-phase) EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
5 7000020160 420 1330 50 Insta. 420kV, 40kA AIS EQUIPMENT 100005443 998734 18 420KV, 1-PHASE BUS POST INSULATORS EA 5 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
6 7000020160 430 1350 10 Insta. 245kV, 40kA AIS EQUIPMENT 100000435 998736 18 245kV, 1600A, 40KA Circuit Breaker(3-Phase) with support structure EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
7 7000020160 430 1350 20 Insta. 245kV, 40kA AIS EQUIPMENT 100000461 998736 18 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with one E/S EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
8 7000020160 430 1350 30 Insta. 245kV, 40kA AIS EQUIPMENT 100000462 998736 18 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with two E/S EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
9 7000020160 430 1350 40 Insta. 245kV, 40kA AIS EQUIPMENT 100000464 998736 18 245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem Isolator without E/S EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
10 7000020160 430 1350 50 Insta. 245kV, 40kA AIS EQUIPMENT 100000443 998736 18 245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
11 7000020160 430 1350 60 Insta. 245kV, 40kA AIS EQUIPMENT 100000484 998736 18 216kV Surge Arrester (1-phase) EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
12 7000020160 430 1350 70 Insta. 245kV, 40kA AIS EQUIPMENT 100001907 998736 18 245 kV,1 phase Bus Post Insulator (except for Line Traps) EA 12 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
13 7000020160 440 1410 10 Erection Hardware for 420 kV I Type S/Y 100000330 998731 18 Erection Hardware for 400kV I type layout-Transformer bay as per specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
14 7000020160 450 1430 10 Erection Hardware for 220 kV DMT Type S 100000486 998731 18 Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Transformer Bay as per specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
15 7000020160 600 1435 30 Insta. 400kV hardware string 100017131 998731 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
16 7000020160 590 1440 10 Insta. 220kv hardware string 100017117 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
17 7000020160 590 1440 20 Insta. 220kv hardware string 100017118 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHOUT TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
18 7000020160 590 1440 30 Insta. 220kv hardware string 100017121 998731 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH THROUGH CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
19 7000020160 590 1440 40 Insta. 220kv hardware string 100017122 998731 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
21 7000020160 470 1470 10 Insta.CRP for 420kV Bays with SAS 100000735 998736 18 Augmentation of existing 400kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
22 7000020160 470 1470 20 Insta.CRP for 420kV Bays with SAS 100000731 998736 18 400kV Transformer Protection Panel (For both HV & MV side)-(with Automation) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
23 7000020160 470 1470 40 Insta.CRP for 420kV Bays with SAS 100000728 998736 18 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
24 7000020160 470 1470 50 Insta.CRP for 420kV Bays with SAS 100002238 998736 18 Digital RTCC Panel consist of digital RTCC relays as per technical specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
25 7000020160 480 1490 10 Insta. CRP for 220kV Bays with SAS 100000743 998736 18 Augmentation of existing 220kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
26 7000020160 480 1490 40 Insta. CRP for 220kV Bays with SAS 100000736 998736 18 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
27 7000020160 490 1513 10 Insta. SAS-AUG 100002069 998736 18 Augmentation of Substation automation System for 400kV Main bay as per Technical Specification EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
28 7000020160 490 1513 20 Insta. SAS-AUG 100002070 998736 18 Augmentation of Substation automation System for 220kV bay as per Technical Specification EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
29 7000020160 610 1515 10 Installation-Cable 100002181 998736 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
30 7000020160 610 1515 20 Installation-Cable 100002182 998736 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
31 7000020160 500 1610 40 Insta. FIRE FIGHTING SYSTEM 100016783 998736 18 HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 400kV, 3-phaseAutotransformer SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
32 7000020160 510 1620 10 Insta. ILLUMINATION SYSTEM 100001021 995461 18 Lighting Panel type ACP-2 as per technical specification EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
33 7000020160 510 1620 40 Insta. ILLUMINATION SYSTEM 100001885 998739 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
34 7000020160 510 1620 50 Insta. ILLUMINATION SYSTEM 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
35 7000020160 510 1620 60 Insta. ILLUMINATION SYSTEM 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 20 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
36 7000020160 520 1680 10 Insta. 220kV Equip. support structures 100001225 995455 18 Erection of Pipe Structure - 220 kV 1-Phase BPI including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 9 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
37 7000020160 520 1680 20 Insta. 220kV Equip. support structures 100001220 995455 18 Erection of Pipe Structure - 220 kV 1-Phase CT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
38 7000020160 520 1680 30 Insta. 220kV Equip. support structures 100001222 995455 18 Erection of Pipe Structure - 220 kV 3-Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 4 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
39 7000020160 520 1680 40 Insta. 220kV Equip. support structures 100001224 995455 18 Erection of Pipe Structure - 220 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
40 7000020160 520 1680 50 Insta. 220kV Equip. support structures 100001226 995455 18 Erection of Pipe Structure - 220 kV 1-Phase High BPI including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
41 7000020160 530 1700 10 Insta. 400KV Equip. Structure 100001212 995455 18 Erection of Pipe Structure - 400 kV 1-Phase CT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
42 7000020160 530 1700 20 Insta. 400KV Equip. Structure 100001217 995455 18 Erection of Pipe Structure - 400 kV, 1-Phase, BPI, (Excluding Wave Trap), including nuts, bolts, all type of washers,packplates, step bolts and gusset plates excluding foundation bolts EA 5 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
43 7000020160 530 1700 30 Insta. 400KV Equip. Structure 100001216 995455 18 Erection of Pipe Structure - 400 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
44 7000020160 530 1700 40 Insta. 400KV Equip. Structure 100001214 995455 18 Erection of Pipe Structure - 400 kV 3-Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
45 7000020160 620 1710 10 Dismantling of Tower & Beam 100005605 995455 18 Dismantling of existing 400 kV tower including transportation and stacking of dismantled material at specified location MT 8 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
46 7000020160 720 1925 10 CIVIL WORKS 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 1392 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
47 7000020160 720 1925 20 CIVIL WORKS 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 84 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
48 7000020160 720 1925 30 CIVIL WORKS 100001328 995454 18 Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 442 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
49 7000020160 720 1925 40 CIVIL WORKS 100001327 995454 18 Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 634 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
51 7000020160 720 1925 60 CIVIL WORKS 100001330 995428 18 Stone filling (40 mm size) for transformer/Reactor foundation M3 21 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
52 7000020160 720 1925 70 CIVIL WORKS 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 37 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
53 7000020160 720 1925 80 CIVIL WORKS 100001712 995428 18 Removing,cleaning and washing of existing stones and respreading of stones in switchyard excluding PCC M2 5776 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
55 7000020160 720 1925 100 CIVIL WORKS 100003114 995454 18 External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 480 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
56 7000020160 720 1925 110 CIVIL WORKS 100001457 995421 18 Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having four rails for auto transformer. M2 344 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
57 7000020160 720 1925 120 CIVIL WORKS 100007701 995462 18 Supplying and erecting dewatering pumps- 2 HP EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
58 7000020160 720 1925 130 CIVIL WORKS 100015791 995454 18 All civil works for Drains construction of Section A-A including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 30 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
59 7000020160 720 1925 140 CIVIL WORKS 100015792 995454 18 All civil works for Drains construction of Section B-B including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
60 7000020160 720 1925 150 CIVIL WORKS 100015793 995454 18 All civil works for Drains construction of Section C-C including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
61 7000020160 720 1925 160 CIVIL WORKS 100015794 995454 18 All civil works for Drains construction of Section D-D including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
62 7000020160 720 1925 170 CIVIL WORKS 100020960 995461 18 RCC culvert crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as per specification. M 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
63 7000020160 720 1925 180 CIVIL WORKS 100020961 995461 18 RCC culvert crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as per specification. M 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
64 7000020160 720 1925 190 CIVIL WORKS 100020962 995461 18 RCC culvert crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as per specification. M 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
65 7000020160 720 1925 200 CIVIL WORKS 130000761 995428 18 14.4.2 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 150 mm dia M 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
66 7000020160 720 1925 210 CIVIL WORKS 130000762 995428 18 14.4.3 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 250 mm dia M 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
67 7000020160 720 1925 220 CIVIL WORKS 100003295 995429 18 Dismantling of RCC in foundation including disposal of debris and reinforcement bars of dismantled RCC works within substationboundaries as per direction of enginner incahrge M3 20 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
B 500MVA 400/230kV 4th ICT at Arasur
68 7000019713 170 30 10 Main Equipment 100001910 998736 18 Insulating Oil for 500MVA, 400KV/220/33 KV, 3-phase Autotransformer SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
70 7000019713 170 30 30 Main Equipment 100002238 998736 18 Digital RTCC Panel consist of digital RTCC relays as per technical specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
C Extn of 400/230kV Arasur SS for 4th ICT
71 7000019713 750 1310 10 420kV, 40kA AIS EQUIPMENT 100000263 998736 18 420kV, 3150A, 40kA Circuit Breaker(3-Phase) without closing resistor(with support structure) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
72 7000019713 750 1310 20 420kV, 40kA AIS EQUIPMENT 100000271 998736 18 420 kV, 3000A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
73 7000019713 750 1310 30 420kV, 40kA AIS EQUIPMENT 100000281 998736 18 420kV, 3150A, 40KA, Isolator (3-phase)(Double Break) with one E/S EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
75 7000019713 750 1310 50 420kV, 40kA AIS EQUIPMENT 100005443 998734 18 420KV, 1-PHASE BUS POST INSULATORS EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
76 7000019713 760 1340 10 245kV, 40kA AIS EQUIPMENT 100000435 998736 18 245kV, 1600A, 40KA Circuit Breaker(3-Phase) with support structure EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
77 7000019713 760 1340 20 245kV, 40kA AIS EQUIPMENT 100000443 998736 18 245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
78 7000019713 760 1340 30 245kV, 40kA AIS EQUIPMENT 100000461 998736 18 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with one E/S EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
79 7000019713 760 1340 40 245kV, 40kA AIS EQUIPMENT 100000462 998736 18 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with two E/S EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
80 7000019713 760 1340 50 245kV, 40kA AIS EQUIPMENT 100000464 998736 18 245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem Isolator without E/S EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
82 7000019713 760 1340 70 245kV, 40kA AIS EQUIPMENT 100001907 998736 18 245 kV,1 phase Bus Post Insulator (except for Line Traps) EA 15 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
83 7000019713 770 1410 10 Erection Hardware for 420 kV I Type S/Y 100000339 998731 18 Erection Hardware for 400kV I type layout-Any feeder Extn. on existing half dia. as per specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
84 7000019713 780 1421 10 420kV Insulator and Hardware 100017131 998731 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
85 7000019713 790 1430 10 Erection Hardware for 220 kV DMT Type S 100000491 998731 18 Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Bus work (three Bay) as per specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
86 7000019713 790 1430 20 Erection Hardware for 220 kV DMT Type S 100000486 998731 18 Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Transformer Bay as per specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
87 7000019713 790 1430 30 Erection Hardware for 220 kV DMT Type S 100001575 995429 18 Dismantling and Re-erection of LM EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
88 7000019713 800 1433 10 220kV Insulator and Hardware 100017117 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
89 7000019713 800 1433 20 220kV Insulator and Hardware 100017115 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
90 7000019713 800 1433 30 220kV Insulator and Hardware 100017118 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHOUT TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
91 7000019713 800 1433 40 220kV Insulator and Hardware 100017116 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHOUT TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
92 7000019713 800 1433 50 220kV Insulator and Hardware 100017121 998731 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH THROUGH CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
93 7000019713 800 1433 60 220kV Insulator and Hardware 100017122 998731 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
95 7000019713 820 1470 10 CRP for 420kV Bays with SAS 100016779 998736 18 400kV Circuit Breaker Relay Panel (with Automation) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
96 7000019713 820 1470 20 CRP for 420kV Bays with SAS 100000731 998736 18 400kV Transformer Protection Panel (For both HV & MV side)-(with Automation) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
97 7000019713 820 1470 30 CRP for 420kV Bays with SAS 100000735 998736 18 Augmentation of existing 400kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
98 7000019713 830 1490 10 CRP for 220kV Bays with SAS 100016778 998736 18 220kV Circuit Breaker Relay Panel (with Automation) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
99 7000019713 830 1490 20 CRP for 220kV Bays with SAS 100000743 998736 18 Augmentation of existing 220kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
100 7000019713 840 1520 10 VMS 100002500 998731 18 Color IP camera, with PAN, TILT and ZOOM facilities, alongwith all required Items, Accessories, Line Interface units, Fiber patchcords, Power supply units, Junction Boxes, Cables, Fiber Optic Cables, etc., and including Integration in existing Hardware andSoftware for Augmentation of Visual Monitoring System as per technical specification. SET 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
101 7000019713 850 1580 10 220kV EHV Cable & Associated Equipments 100003359 998736 18 220 KV Cable end termination(s) (AIS TYPE) at substation as per technical specification EA 8 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
102 7000019713 850 1580 20 220kV EHV Cable & Associated Equipments 100003013 998736 18 220kV HV Power Cable along with accessories KM 1.2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
103 7000019713 850 1580 30 220kV EHV Cable & Associated Equipments 100003969 995423 18 Construction of buried cable trench along with excavation, PCC, back filling, restoration and construction of jointing bays (asper requirement) etc. as per technical specification KM 0.3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
104 7000019713 860 1590 10 POWER & CONTROL CABLE 100002180 998736 18 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
105 7000019713 860 1590 20 POWER & CONTROL CABLE 100002181 998736 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
106 7000019713 860 1590 30 POWER & CONTROL CABLE 100002182 998736 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
107 7000019713 880 1600 10 AIR CONDITIONING & VENTILATION SYSTEM 100001882 995463 18 Air conditioning system for Switchyard Panel Room of 6m length SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
108 7000019713 890 1610 10 FIRE FIGHTING SYSTEM 100016783 998736 18 HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 400kV, 3-phaseAutotransformer SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
109 7000019713 890 1610 20 FIRE FIGHTING SYSTEM 100002062 995461 18 Fire Detection and Alarm System for Switchyard Panel Room of 6 m length SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
110 7000019713 890 1610 30 FIRE FIGHTING SYSTEM 100000975 995461 18 4.5 kg CO2 type Portable Fire extinguisher EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
111 7000019713 900 1620 10 ILLUMINATION SYSTEM 100001116 998739 18 Illumination System for switchyard panel room of 6 m length SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
112 7000019713 900 1620 20 ILLUMINATION SYSTEM 100004937 998731 18 Fire Wall Mounted LED Luminarie Type FL-2 (250W) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
113 7000019713 900 1620 30 ILLUMINATION SYSTEM 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
114 7000019713 900 1620 40 ILLUMINATION SYSTEM 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 20 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
115 7000019713 900 1620 50 ILLUMINATION SYSTEM 100001885 998739 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
116 7000019713 900 1620 60 ILLUMINATION SYSTEM 100001022 998731 18 Lighting Panel type ACP-3 as per technical specification EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
117 7000019713 900 1620 70 ILLUMINATION SYSTEM 100002407 995429 18 Dismantling and reerection of existing street light poles alongwith fixtures, junction box etc. EA 10 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
118 7000019713 910 1660 10 400kV Equipment support structures 100001217 995455 18 Erection of Pipe Structure - 400 kV, 1-Phase, BPI, (Excluding Wave Trap), including nuts, bolts, all type of washers,packplates, step bolts and gusset plates excluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
119 7000019713 910 1660 20 400kV Equipment support structures 100001212 995455 18 Erection of Pipe Structure - 400 kV 1-Phase CT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
120 7000019713 910 1660 30 400kV Equipment support structures 100001214 995455 18 Erection of Pipe Structure - 400 kV 3-Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
121 7000019713 910 1660 40 400kV Equipment support structures 100001216 995455 18 Erection of Pipe Structure - 400 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
122 7000019713 920 1670 10 220 kV Towers 100001187 995455 18 Erection of Std 220 kV Tower CC including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
123 7000019713 920 1670 20 220 kV Towers 100001191 995455 18 Erection of Std 220 kV Tower CTA including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
124 7000019713 920 1670 30 220 kV Towers 100001192 995455 18 Erection of Std 220 kV Tower CTB including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
125 7000019713 920 1670 40 220 kV Towers 100001193 995455 18 Erection of Std 220 kV Tower CTC including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
126 7000019713 920 1670 50 220 kV Towers 100001198 995455 18 Erection of Std 220 kV Tower CTG including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
127 7000019713 920 1670 60 220 kV Towers 100001199 995455 18 Erection of Std 220 kV Tower CTH including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
128 7000019713 920 1670 70 220 kV Towers 100001204 995455 18 Erection of Std 220 kV Gantry B1 including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
129 7000019713 920 1670 80 220 kV Towers 100001205 995455 18 Erection of Std 220 kV Gantry BG1 including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 5 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
130 7000019713 920 1670 90 220 kV Towers 100037960 995455 18 Erection of Std 220 kV Tower CTA (W/O peak) including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
131 7000019713 930 1680 10 220kV Equipment support structures 100001226 995455 18 Erection of Pipe Structure - 220 kV 1-Phase High BPI including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
132 7000019713 930 1680 20 220kV Equipment support structures 100001225 995455 18 Erection of Pipe Structure - 220 kV 1-Phase BPI including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 12 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
133 7000019713 930 1680 30 220kV Equipment support structures 100001220 995455 18 Erection of Pipe Structure - 220 kV 1-Phase CT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
134 7000019713 930 1680 40 220kV Equipment support structures 100001222 995455 18 Erection of Pipe Structure - 220 kV 3-Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 4 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
135 7000019713 930 1680 50 220kV Equipment support structures 100001224 995455 18 Erection of Pipe Structure - 220 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
136 7000019713 1040 1770 10 ERECTION OF FDN BOLTS FASTENERS LATTICE 100001210 995455 18 Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 1.5 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
137 7000019713 1040 1770 20 ERECTION OF FDN BOLTS FASTENERS LATTICE 100001680 995455 18 Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 0.1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
138 7000019713 1040 1770 30 ERECTION OF FDN BOLTS FASTENERS LATTICE 100001681 995455 18 Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 0.2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
139 7000019713 1040 1770 40 ERECTION OF FDN BOLTS FASTENERS LATTICE 100001674 995455 18 Erection of 28mm dia foundation bolts including nuts, checknuts, washers and packplates. EA 324 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
140 7000019713 1040 1770 60 ERECTION OF FDN BOLTS FASTENERS LATTICE 100001676 995455 18 Erection of 40mm dia foundation bolts including nuts, checknuts, washers and packplates. EA 16 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
141 7000019713 1040 1770 70 ERECTION OF FDN BOLTS FASTENERS LATTICE 100001677 995455 18 Erection of 56mm dia foundation bolts including nuts, checknuts, washers and packplates EA 96 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
142 7000019713 1050 1780 10 CIVIL WORKS 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 4250 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
143 7000019713 1050 1780 20 CIVIL WORKS 100011662 995433 18 Excavation in hard rock which require blasting (including chemical blasting and rock excavated using specialized tools) for allfoundation works including stacking, measuring, disposal etc.for all leads and lifts as per technical specification. M3 500 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
144 7000019713 1050 1780 30 CIVIL WORKS 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 226 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
145 7000019713 1050 1780 40 CIVIL WORKS 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 50 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
146 7000019713 1050 1780 50 CIVIL WORKS 100001328 995454 18 Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 689 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
147 7000019713 1050 1780 60 CIVIL WORKS 100001327 995454 18 Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 1120 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
149 7000019713 1050 1780 80 CIVIL WORKS 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 26 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
150 7000019713 1050 1780 90 CIVIL WORKS 100001714 995428 18 Stone spreading in switchyard excluding PCC M2 2000 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
152 7000019713 1050 1780 110 CIVIL WORKS 100001376 995428 18 Removing,cleaning and washing of existing stones and respreading of stones in switchyard after doing anti-weed treatment excludingPCC M2 7000 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
153 7000019713 1050 1780 120 CIVIL WORKS 100001330 995428 18 Stone filling (40 mm size) for transformer/Reactor foundation M3 18 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
154 7000019713 1050 1780 130 CIVIL WORKS 100002580 995421 18 Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having four rails M2 86 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
155 7000019713 1050 1780 140 CIVIL WORKS 100003114 995454 18 External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 200 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
156 7000019713 1050 1780 150 CIVIL WORKS 100004507 995421 18 3.75m wide Cement Concrete road with PCC shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS.However, reinforcement steel and all type concrete shall be paid separately under relevant items M2 563 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
157 7000019713 1050 1780 160 CIVIL WORKS 100001391 995477 18 New chain Link Fencing excluding concrete M 100 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
158 7000019713 1050 1780 170 CIVIL WORKS 100001542 995429 18 Dismantling & Re-erection of Existing fence M 200 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
159 7000019713 1050 1780 180 CIVIL WORKS 100001735 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 100 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
160 7000019713 1050 1780 190 CIVIL WORKS 100001737 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as perspecification. M 50 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
161 7000019713 1050 1780 200 CIVIL WORKS 100007701 995462 18 Supplying and erecting dewatering pumps- 2 HP EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
162 7000019713 1050 1780 210 CIVIL WORKS 100001764 995462 18 Drains Section D-D including culverts but excluding concrete & reinforcement steel M 300 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
163 7000019713 1050 1780 220 CIVIL WORKS 100002911 995432 18 Earthwork in excavation & filling in all types of soil and soft/disintegrated rock in open areas/nallas/channels, to the requiredslopes, shapes, levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain(dewatering), pumping, removal of slush, preparing embankments/marginal banks, loosening, dressing, spreading material in layers notexceeding 200mm, as per direction of Engineer-in-Charge, water flooding, compacting to achieve 95% consolidation at optimum moisturecontent, finishing etc. all complete, for all leads and lifts within leveling boundary, including disposal of surplus earth andstacking of unsuitable material within a lead of 2.0 Km beyond substation boundary, with all labour, material, tools, tackles andequipment, safeguards and incidentals, Royalty,taxes etc. as necessary, as per drawings, specification and directions of theEngineer-in-Charge. Clearing of jungle is included in this item. (Only excavation/cutting will be measured for payment purpose.) M3 500 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
164 7000019713 1050 1780 230 CIVIL WORKS 100001454 995429 18 Demolishing RCC work including stacking of steel bars and disposal of unserviceable material. M3 50 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
165 7000019713 1050 1780 240 CIVIL WORKS 100003437 995454 18 Switchyard Panel Room - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 30 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
166 7000019713 1070 1800 10 SAS 100002070 998736 18 Augmentation of Substation automation System for 220kV bay as per Technical Specification EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
167 7000019713 1070 1800 20 SAS 100005606 998736 18 Interfacing of relays under present scope with existing SAS including database, displays devlopment of additional displays & reportand upgradation of hardware and software etc as per the requirement for completion of work under present scope SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
D 500MVA 400/230kV 4th ICT at Hosur
168 7000019714 1030 30 10 Main Equipment 100001910 998736 18 Insulating Oil for 500MVA, 400KV/220/33 KV, 3-phase Autotransformer SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
170 7000019714 1030 30 30 Main Equipment 100002238 998736 18 Digital RTCC Panel consist of digital RTCC relays as per technical specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
E Extn of 400/230kV Hosur SS for 4th ICT
171 7000019714 580 1310 10 420kV, 40kA AIS EQUIPMENT 100000263 998736 18 420kV, 3150A, 40kA Circuit Breaker(3-Phase) without closing resistor(with support structure) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
172 7000019714 580 1310 20 420kV, 40kA AIS EQUIPMENT 100000271 998736 18 420 kV, 3000A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
173 7000019714 580 1310 30 420kV, 40kA AIS EQUIPMENT 100000281 998736 18 420kV, 3150A, 40KA, Isolator (3-phase)(Double Break) with one E/S EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
176 7000019714 580 1310 60 420kV, 40kA AIS EQUIPMENT 100001522 995429 18 Dismantling & re-erection of 400kV SA EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
177 7000019714 580 1310 70 420kV, 40kA AIS EQUIPMENT 100001545 995429 18 Dismantling & re-erection of 63MVAR shunt Reactor EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
178 7000019714 580 1310 80 420kV, 40kA AIS EQUIPMENT 100032667 998875 18 Service-Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
179 7000019714 590 1340 10 245kV, 40kA AIS EQUIPMENT 100000435 998736 18 245kV, 1600A, 40KA Circuit Breaker(3-Phase) with support structure EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
180 7000019714 590 1340 20 245kV, 40kA AIS EQUIPMENT 100000443 998736 18 245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
181 7000019714 590 1340 30 245kV, 40kA AIS EQUIPMENT 100000461 998736 18 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with one E/S EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
182 7000019714 590 1340 40 245kV, 40kA AIS EQUIPMENT 100000462 998736 18 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with two E/S EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
183 7000019714 590 1340 50 245kV, 40kA AIS EQUIPMENT 100000464 998736 18 245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem Isolator without E/S EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
185 7000019714 590 1340 70 245kV, 40kA AIS EQUIPMENT 100001907 998736 18 245 kV,1 phase Bus Post Insulator (except for Line Traps) EA 15 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
186 7000019714 600 1410 10 Erection Hardware for 420 kV I Type S/Y 100000339 998731 18 Erection Hardware for 400kV I type layout-Any feeder Extn. on existing half dia. as per specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
187 7000019714 600 1410 20 Erection Hardware for 420 kV I Type S/Y 100000333 998731 18 Erection Hardware for 400kV I type layout-Re-oriented Transformer bay as per specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
188 7000019714 610 1421 10 420kV Insulator and Hardware 100017131 998731 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
189 7000019714 620 1430 10 Erection Hardware for 220 kV DMT Type S 100000490 998731 18 Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Bus work (two Bay) as per specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
190 7000019714 620 1430 20 Erection Hardware for 220 kV DMT Type S 100000486 998731 18 Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Transformer Bay as per specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
192 7000019714 630 1433 10 220kV Insulator and Hardware 100017117 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 12 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
193 7000019714 630 1433 20 220kV Insulator and Hardware 100017115 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
194 7000019714 630 1433 30 220kV Insulator and Hardware 100017118 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHOUT TURN BUCKLE SUITABLE FOR TWIN CONDUCTOR EA 12 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
195 7000019714 630 1433 40 220kV Insulator and Hardware 100017116 998731 18 220KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHOUT TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
196 7000019714 630 1433 50 220kV Insulator and Hardware 100017121 998731 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH THROUGH CLAMP SUITABLE FOR TWIN CONDUCTOR EA 9 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
197 7000019714 630 1433 60 220kV Insulator and Hardware 100017122 998731 18 220KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH DROP CLAMP SUITABLE FOR TWIN CONDUCTOR EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
198 7000019714 640 1480 10 CRP for conventianal 420kV Bays 100016775 998736 18 400kV Circuit Breaker Relay Panel EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
199 7000019714 640 1480 20 CRP for conventianal 420kV Bays 100000793 998736 18 400kV Transformer Protection Panel (For both HV & MV side) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
200 7000019714 640 1480 30 CRP for conventianal 420kV Bays 100000796 998736 18 Augmentation of existing 400kV bus bar protection scheme SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
201 7000019714 640 1480 40 CRP for conventianal 420kV Bays 100000788 998736 18 Augmentation of existing 400kV Control Panel (Bus Scheme as per SLD) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
202 7000019714 650 1490 10 CRP for CONV. 220kV Bays 100016774 998736 18 220kV Circuit Breaker Relay Panel EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
203 7000019714 650 1490 20 CRP for CONV. 220kV Bays 100000808 998736 18 Augmentation of existing 220kV bus bar protection scheme SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
204 7000019714 650 1490 30 CRP for CONV. 220kV Bays 100000801 998736 18 Augmentation of existing Simplex Control Panel for 220kV (Bus scheme as per SLD) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
205 7000019714 660 1520 10 VMS 100002500 998731 18 Color IP camera, with PAN, TILT and ZOOM facilities, alongwith all required Items, Accessories, Line Interface units, Fiber patchcords, Power supply units, Junction Boxes, Cables, Fiber Optic Cables, etc., and including Integration in existing Hardware andSoftware for Augmentation of Visual Monitoring System as per technical specification. SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
208 7000019714 680 1590 10 POWER & CONTROL CABLE 100002180 998736 18 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
209 7000019714 680 1590 20 POWER & CONTROL CABLE 100002181 998736 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
210 7000019714 680 1590 30 POWER & CONTROL CABLE 100002182 998736 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
211 7000019714 690 1610 10 FIRE FIGHTING SYSTEM 100016783 998736 18 HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 400kV, 3-phaseAutotransformer SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
212 7000019714 690 1610 20 FIRE FIGHTING SYSTEM 100004453 995429 18 Dismantling and re-erection of HVWS Spray system as per technical specification SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
213 7000019714 700 1620 10 ILLUMINATION SYSTEM 100001022 998731 18 Lighting Panel type ACP-3 as per technical specification EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
214 7000019714 700 1620 20 ILLUMINATION SYSTEM 100001885 998739 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
215 7000019714 700 1620 30 ILLUMINATION SYSTEM 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 20 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
216 7000019714 700 1620 40 ILLUMINATION SYSTEM 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 15 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
217 7000019714 700 1620 50 ILLUMINATION SYSTEM 100004937 998731 18 Fire Wall Mounted LED Luminarie Type FL-2 (250W) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
218 7000019714 710 1660 10 400kV Equipment support structures 100001216 995455 18 Erection of Pipe Structure - 400 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
219 7000019714 710 1660 20 400kV Equipment support structures 100001214 995455 18 Erection of Pipe Structure - 400 kV 3-Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
220 7000019714 710 1660 30 400kV Equipment support structures 100001212 995455 18 Erection of Pipe Structure - 400 kV 1-Phase CT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
221 7000019714 710 1660 40 400kV Equipment support structures 100001217 995455 18 Erection of Pipe Structure - 400 kV, 1-Phase, BPI, (Excluding Wave Trap), including nuts, bolts, all type of washers,packplates, step bolts and gusset plates excluding foundation bolts EA 9 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
222 7000019714 720 1670 10 220 kV Towers 100001183 995455 18 Erection of Std 220 kV Tower CA including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
223 7000019714 720 1670 20 220 kV Towers 100001184 995455 18 Erection of Std 220 kV Tower (w/o peak) CA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
224 7000019714 720 1670 30 220 kV Towers 100001185 995455 18 Erection of Std 220 kV Tower CB including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
225 7000019714 720 1670 40 220 kV Towers 100001187 995455 18 Erection of Std 220 kV Tower CC including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
226 7000019714 720 1670 50 220 kV Towers 100001188 995455 18 Erection of Std 220 kV Tower CD including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
227 7000019714 720 1670 60 220 kV Towers 100001199 995455 18 Erection of Std 220 kV Tower CTH including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
228 7000019714 720 1670 70 220 kV Towers 100001200 995455 18 Erection of Std 220 kV Tower CTI including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
229 7000019714 720 1670 80 220 kV Towers 100001204 995455 18 Erection of Std 220 kV Gantry B1 including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 4 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
230 7000019714 720 1670 90 220 kV Towers 100001206 995455 18 Erection of Std 220 kV Gantry BA including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
231 7000019714 720 1670 100 220 kV Towers 100001207 995455 18 Erection of Std 220 kV Gantry BGA including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
232 7000019714 720 1670 110 220 kV Towers 100001668 995455 18 Erection of Std LM (40m) including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excluding foundationbolts EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
234 7000019714 730 1680 10 220kV Equipment support structures 100001226 995455 18 Erection of Pipe Structure - 220 kV 1-Phase High BPI including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
235 7000019714 730 1680 20 220kV Equipment support structures 100001225 995455 18 Erection of Pipe Structure - 220 kV 1-Phase BPI including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 12 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
236 7000019714 730 1680 30 220kV Equipment support structures 100001220 995455 18 Erection of Pipe Structure - 220 kV 1-Phase CT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
237 7000019714 730 1680 40 220kV Equipment support structures 100001222 995455 18 Erection of Pipe Structure - 220 kV 3-Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 4 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
238 7000019714 730 1680 50 220kV Equipment support structures 100001224 995455 18 Erection of Pipe Structure - 220 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
239 7000019714 820 1700 10 ERECTION OF FDN BOLTS, FASTENERS, LATTIC 100001241 995455 18 Erection of Equipment Support (Pipe) Structures to be designed during detailed engineering. MT 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
240 7000019714 820 1700 20 ERECTION OF FDN BOLTS, FASTENERS, LATTIC 100001680 995455 18 Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 0.15 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
241 7000019714 820 1700 30 ERECTION OF FDN BOLTS, FASTENERS, LATTIC 100001681 995455 18 Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 0.15 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
242 7000019714 820 1700 40 ERECTION OF FDN BOLTS, FASTENERS, LATTIC 100001674 995455 18 Erection of 28mm dia foundation bolts including nuts, checknuts, washers and packplates. EA 316 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
243 7000019714 820 1700 60 ERECTION OF FDN BOLTS, FASTENERS, LATTIC 100001676 995455 18 Erection of 40mm dia foundation bolts including nuts, checknuts, washers and packplates. EA 96 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
244 7000019714 820 1700 70 ERECTION OF FDN BOLTS, FASTENERS, LATTIC 100001677 995455 18 Erection of 56mm dia foundation bolts including nuts, checknuts, washers and packplates EA 80 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
245 7000019714 830 1710 10 Civil Works 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 4000 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
246 7000019714 830 1710 20 Civil Works 100011662 995433 18 Excavation in hard rock which require blasting (including chemical blasting and rock excavated using specialized tools) for allfoundation works including stacking, measuring, disposal etc.for all leads and lifts as per technical specification. M3 800 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
247 7000019714 830 1710 30 Civil Works 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 211 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
248 7000019714 830 1710 40 Civil Works 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 50 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
249 7000019714 830 1710 50 Civil Works 100001328 995454 18 Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 628 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
250 7000019714 830 1710 60 Civil Works 100001327 995454 18 Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 1025 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
252 7000019714 830 1710 80 Civil Works 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 37 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
253 7000019714 830 1710 90 Civil Works 100001714 995428 18 Stone spreading in switchyard excluding PCC M2 1200 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
255 7000019714 830 1710 110 Civil Works 100001376 995428 18 Removing,cleaning and washing of existing stones and respreading of stones in switchyard after doing anti-weed treatment excludingPCC M2 8200 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
256 7000019714 830 1710 120 Civil Works 100001330 995428 18 Stone filling (40 mm size) for transformer/Reactor foundation M3 36 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
257 7000019714 830 1710 130 Civil Works 100002581 995421 18 Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having two rails M2 62 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
258 7000019714 830 1710 140 Civil Works 100002580 995421 18 Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having four rails M2 86 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
259 7000019714 830 1710 150 Civil Works 100003114 995454 18 External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 200 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
260 7000019714 830 1710 160 Civil Works 100004507 995421 18 3.75m wide Cement Concrete road with PCC shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS.However, reinforcement steel and all type concrete shall be paid separately under relevant items M2 375 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
261 7000019714 830 1710 170 Civil Works 100001735 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 120 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
262 7000019714 830 1710 180 Civil Works 100001737 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as perspecification. M 50 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
263 7000019714 830 1710 190 Civil Works 100007701 995462 18 Supplying and erecting dewatering pumps- 2 HP EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
264 7000019714 830 1710 200 Civil Works 100001761 995462 18 Drains section A-A including culverts but excluding concrete & reinforcement steel M 175 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
265 7000019714 830 1710 210 Civil Works 100001762 995462 18 Drains Section B-B including culverts but excluding concrete & reinforcement steel M 90 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
266 7000019714 830 1710 220 Civil Works 100002911 995432 18 Earthwork in excavation & filling in all types of soil and soft/disintegrated rock in open areas/nallas/channels, to the requiredslopes, shapes, levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain(dewatering), pumping, removal of slush, preparing embankments/marginal banks, loosening, dressing, spreading material in layers notexceeding 200mm, as per direction of Engineer-in-Charge, water flooding, compacting to achieve 95% consolidation at optimum moisturecontent, finishing etc. all complete, for all leads and lifts within leveling boundary, including disposal of surplus earth andstacking of unsuitable material within a lead of 2.0 Km beyond substation boundary, with all labour, material, tools, tackles andequipment, safeguards and incidentals, Royalty,taxes etc. as necessary, as per drawings, specification and directions of theEngineer-in-Charge. Clearing of jungle is included in this item. (Only excavation/cutting will be measured for payment purpose.) M3 500 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
267 7000019714 830 1710 230 Civil Works 100001454 995429 18 Demolishing RCC work including stacking of steel bars and disposal of unserviceable material. M3 200 INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0.18 0.00
Total Corrected Price (excl. GST) GST Amount
# In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date Printed Name
Place Designation
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule - 4
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Training Charges :
SI. No. PR No Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘…’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘---’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit Charges Total Charges
NOTE: To and fro charges and accommodation for the Instructor (Trainer) and Training material for the Trainees shall be included in the prices quoted by the bidder.
# In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank” “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder
Place Printed Name
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule - 5
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST on Goods 0.00 Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00 Sales Tax 0.00 Sales Tax 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule - 5
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST on Goods 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule - 6
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule - 6 After Discount
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3
Installation Charges
4 TOTAL SCHEDULE NO. 4
Training Charges
5 TOTAL SCHEDULE NO. 5
Taxes and Duties
6 TOTAL SCHEDULE NO. 7
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5]
Date : Printed Name :
Place : Designation :
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule - 6
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR) From Sch-6 Discount Factors
1 TOTAL SCHEDULE NO. 1 0.00 0.00 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00 0.00 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00 0.00 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Schedule 7
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
Bidder’s Name and Address (Sole Bidder) : To:
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Type tests on Earthwire, Hardwar Fittings & accessories of conductor & earthwire:
SL. NO. PR No Line Item No Code HSN of the Equipment /item for which type test is to be conducted Whether HSN in column ‘---’ is confirmed. If not indicate applicable the HSN code # Rate of GST applicable ( in %) Whether rate of GST in column ‘---’ is confirmed. If not indicate applicable rate of GST # Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
Date Printed Name
Place Designation
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233
Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
SL. NO. Description of Test #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Letter of Discount
LETTER OF DISCOUNT
Contract Services Schedule 1 0.00
Power Grid Corporation of India Ltd., Schedule 2 0.00
"Saudamini", Plot No.-2 Schedule 3 0.00
Sector-29, (near IFFCO Chowk) Total 0.00
Gurgaon (Haryana) - 122001
Subject : Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Sch-1 Sch-2 Sch-3
1 Discount on lum-sum basis on total price quoted by us without GST. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3, Sch-4 & Sch-7] In Rs. 0.00 0.00 0.00
2 Discount on percent basis on total price quoted by us without GST. [The discount shall be applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3, Sch-4 & Sch-7] In Percent (%) 0.00 0.00 0.00
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Rs. 0.00
Schedule-3 : Installation Charges In Rs. 0.00
Schedule-4 : Training Charges In Rs.
Schedule-7 : Type Test Charges In Rs.
4 Discount on percent basis on the Schedules as given below : [The discount shall be applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Percent (%) 0.00
Schedule-3 : Installation Charges In Percent (%) 0.00
Schedule-4 : Training Charges In Percent (%)
Schedule-7 : Type Test Charges In Percent (%)
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation. #DIV/0! #DIV/0! #DIV/0! #DIV/0! #REF!
[Discount will not be calculated authometrically. However, the same shall be considered during evaluation.]
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain, 0.00 0.00 0.00
Yours faithfully, 0.00000000 0.00000000 0.00000000 Discount Factors
For and on behalf of
Date : Printed Name : 0.00
Place : Designation : 0.00
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
SPEC. NO.: CC/NT/AIS/DOM/A04/22/00233 Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
0 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : Substation Package SS-100 for (i) Extn. of 400/230kV Arasur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500MVA, 400/230kV ICT (4th) at Arasur substation (ii) Extn. of 400/230kV Hosur S/S including supply of one no. 500MVA ICT associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/230kV ICT (4th) at Hosur substation (iii) Extn. of 400/220kV Raigarh (PG) S/S associated with Augmentation of Transformation Capacity by 1x500 MVA, 400/220kV ICT (3rd) at Raigarh (PG) substation 15 th
Dear Ladies and/or Gentlemen, 16 th
1.0 In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 0/- () or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 17 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Installation Charges. Sole Bidder 23 th
Schedule 4 Training charges for training to be imparted. 24 th
Schedule 5 Taxes and Duties not included in Schedule 1 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges for Type Tests to be conducted 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of test
Date : Printed Name : 0.00
Place : Designation : 0.00
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
ALL FIGURES ARE IN INDIAN RUPEES
SL. PRICE COMPONENT QUOTED PRICE CORRECTED PRICE
1 Price of Plant and Equipment (including Mandatory Spares Parts) to be supplied [Schedule-1] 0.00 0
2 Local Transportation, In-transit Insurance, loading and unloading charges [Schedule-2] 0.00 0
3 Installation Charges [Schedule-3] 0.00 0
4 Type Test Charges [Schedule-7] Not Applicable Not Applicable
5 Total Bid Price excluding GST (1+2+3+4) 0.00 0
6 Discount NIL NIL
7 Total Bid Price excluding GST (1+2+3+4) 0.00 0
8 Taxes & Duties:
GST on Supply of Goods @5% 0.00 0 total GST on supply 291545315.52
GST on Supply of Goods @12% 0.00 0
GST on Supply of Goods @12% 0.00 0
GST on Supply of Goods @18% 0
GST on Supply of Goods @28% 0
GST on Supply of Installation Services @ 18% 0.00 0
GST on Type Test Charges Not Applicable Not Applicable
9 Total Taxes & Duties 0.00 0.00
10 Total Bid Price (including Taxes & Duties) 0.00 0
Note-1: It may be mentioned that KEC in Schedule-1 & 3 of their bid, have confirmed/deemed confirmed HSN/SAC code. Also, KEC have confirmed/ deemed confirmed rate of GST for all the items/services in Schedule-1 & 3. Hence the GST tax rate as quoted by KEC has been considered to arrive at their total evaluated bid price, in line with the provisions of the Bidding Documents.
Note-2: It may be mentioned that KEC in Schedule-3 of their bid, have quoted unit prices in more than 2 place of decimals. Accordingly, to work out the total corrected price, unit rates quoted by KEC are rounded off to 2 place of decimals.
765kV Transformer Package TR-35 associated with (i) Transmission Network Expansion in Gujarat to increase its ATC from ISTS: Part B; (ii) Transmission Network Expansion in Gujarat to increase its ATC from ISTS: Part C; and (iii) Transmission Network Expansion in Gujarat associated with integration of RE projects from Khavda potential RE Zone; Spec. No.: 5002002164/TRANSFORMER/DOM/A04-CC CS -5
Total Ex-Works Price Direct 0.00
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF!
Total Ex-works Price including Type Test charges #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
^ If the item(s) quoted/considered as "Bought-out" in the bid are manufactured at Bidder's works and confirmed to be supplied under “Direct transaction” by the bidder, then the taxes and duties on such items shall be paid/reimbursed by POWERGRID in line with the provisions of Bidding Documents. For this purpose, at the time of award, the Ex-works price (exclusive of taxes & duties) shall be arrived at from the quoted Ex-works price (inclusive of taxes ad duties) by excluding taxes and duties applicable on such items, as on date of Bid opening, in case of supplies from manufacturer proposed in the bid. During contract execution, the taxes and duties on such items shall be paid/reimbursed at actuals, limited to the rates prevailing on date of Bid opening.
Place : Printed Name : --
Total F&I Price (=SUM(I16:I27))
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Total Installaiton Charges #REF!
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Date : (=IF('Sch-1'!B43=0,"", 'Sch-1'!B43)) (="Printed Name : " & IF('Sch-1'!E44=0,"",'Sch-1'!E44))
Place : (=IF('Sch-1'!B44=0,"", 'Sch-1'!B44)) (="Designation : " & IF('Sch-1'!E45=0,"",'Sch-1'!E45))
TOTAL TYPE TEST CHARGES (=SUM(I17:I18))
Date : (='Sch-1'!B43) (="Printed Name : " & 'Sch-1'!E44)
Place : (='Sch-1'!B44) (="Designation : " & 'Sch-1'!E45)
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
#REF! 0.00 #REF! 0.00 #REF!
#REF! #REF! #N/A
#REF! #REF! 0 #REF! #REF! 0
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 0 0 #REF! plus
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 0 1 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 1 0 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 1 1 #REF!
#REF! 0 1 0 0 #REF!
1 One 1 One 1 One 1 One #REF! 0 1 0 1 #REF!
2 Two 2 Two 2 Two 2 Two #REF! 0 1 1 0 #REF!
3 Three 3 Three 3 Three 3 Three #REF! 0 1 1 1 #REF!
4 Four 4 Four 4 Four 4 Four #REF! 1 0 0 0 #REF!
5 Five 5 Five 5 Five 5 Five #REF! 1 0 0 1 #REF!
6 Six 6 Six 6 Six 6 Six #REF! 1 0 1 0 #REF!
7 Seven 7 Seven 7 Seven 7 Seven #REF! 1 0 1 1 #REF!
8 Eight 8 Eight 8 Eight 8 Eight #REF! 1 1 0 0 #REF!
9 Nine 9 Nine 9 Nine 9 Nine #REF! 1 1 0 1 #REF!
10 Ten 10 Ten 10 Ten 10 Ten #REF! 1 1 1 0 #REF!
11 Eleven 11 Eleven 11 Eleven 11 Eleven #REF! 1 1 1 1 #REF!
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen #REF! 0 0 0 0 #REF! +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen #REF! 0 0 0 1 #REF! /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen #REF! 0 0 1 0 #REF! /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen #REF! 0 0 1 1 #REF!
20 Twenty 20 Twenty 20 Twenty 20 Twenty #REF! 0 1 0 0 #REF!
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One #REF! 0 1 0 1 #REF!
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two #REF! 0 1 1 0 #REF!
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three #REF! 0 1 1 1 #REF!
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four #REF! 1 0 0 0 #REF!
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five #REF! 1 0 0 1 #REF!
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six #REF! 1 0 1 0 #REF!
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven #REF! 1 0 1 1 #REF!
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight #REF! 1 1 0 0 #REF!
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine #REF! 1 1 0 1 #REF!
30 Thirty 30 Thirty 30 Thirty 30 Thirty #REF! 1 1 1 0 #REF!
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One #REF! 1 1 1 1 #REF!
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
ROAD CULVERT.pdf
pdf • 1.50 MB
SPR 6 MTR NEW.pdf
pdf • 1.62 MB
STD DRAIN.pdf
pdf • 2.24 MB
STD.BOLT.DRG.220400KV.pdf
pdf • 0.34 MB
RCC ROAD WITH PCC SHOULDER.pdf
pdf • 4.53 MB
474056-220kv 2CTI(SH.1 OF 1).pdf
pdf • 5.37 MB
CABLE TRENCH & CROSSING DETAILS.pdf
pdf • 0.63 MB
CHAIN LINK FENCING.pdf
pdf • 1.44 MB
HBPI-SS82.pdf
pdf • 0.21 MB
RAIL CUM ROAD.pdf
pdf • 1.30 MB
474054-220kv 2CTG(SH.1 OF 1).pdf
pdf • 4.63 MB
474055-220kv 2CTH(SH.1 OF 1).pdf
pdf • 4.80 MB
474050-220kv 2CTC(SH.1 OF 1).pdf
pdf • 5.30 MB
474049-220kv 2CTB(SH.1 OF 1).pdf
pdf • 5.19 MB
474048-220kv 2CTA(SH.1 OF 1).pdf
pdf • 5.14 MB
474046-220kv 2CD(2 sheets).pdf
pdf • 6.64 MB
474045-220kv 2CC(SH.1 OF 1).pdf
pdf • 4.97 MB
474044-220kv 2CB(SH.1 OF 1).pdf
pdf • 5.15 MB
474043-220kv 2CA(SH.1 OF 1).pdf
pdf • 5.23 MB
474042-220kv 2BG1(SH.1 OF 1).pdf
pdf • 5.52 MB
474041-220kv 2B1(SH.1 OF 1).pdf
pdf • 5.55 MB
474039-220kv 2BA(SH.1 OF 1).pdf
pdf • 4.62 MB
474040-220kv 2BGA(SH.1 OF 1).pdf
pdf • 5.09 MB
474005-400kv 4ISO(SH.1 OF 1).pdf
pdf • 0.71 MB
474006-220kv 2CT(SH.1 OF 1).pdf
pdf • 0.57 MB
474006-400kv 4CT(SH.1 OF 1).pdf
pdf • 0.60 MB
474038-220kv 2P1(SH.1 OF 1).pdf
pdf • 4.07 MB
40-LM-47-0 -SH-01-02.pdf
pdf • 3.29 MB
40-LM-47-0-SH-02-02.pdf
pdf • 2.57 MB
474001-220kv 2BPI(SH.1 OF 1).pdf
pdf • 0.49 MB
474001-400kv 4BPI(SH.1 OF 1).pdf
pdf • 0.56 MB
474004-220kv 2LA(SH.1 OF 1).PDF
pdf • 0.43 MB
474004-400kv 4LA(SH.1 OF 1).pdf
pdf • 0.59 MB
474005-220kv 2ISO(SH.1 OF 1).pdf
pdf • 0.56 MB
400KV GA FOR RAIGARH BAY EXTN (ICT#3)-Annex II.pdf
pdf • 0.12 MB
SLD RAIGARH EXTN-Annex I.pdf
pdf • 0.36 MB
Typical module.pdf
pdf • 0.14 MB
Existing Hosur Electrical Plan.pdf
pdf • 5.84 MB
Existing Hosur Electrical section.pdf
pdf • 2.31 MB
Existing Hosur Layout Plan 2.pdf
pdf • 0.87 MB
Existing Hosur Layout Section 2.pdf
pdf • 0.33 MB
Existing VMS drawing.pdf
pdf • 2.31 MB
GA Hosur.pdf
pdf • 1.50 MB
Hosur Existing Cable trench layout 2.pdf
pdf • 0.69 MB
Hosur existing Cable trench layout1.pdf
pdf • 0.42 MB
Hosur Existing Earthing Layout.pdf
pdf • 0.49 MB
SLD HOSUR.pdf
pdf • 0.26 MB
Existing Layout.pdf
pdf • 9.79 MB
EHV Cable section.pdf
pdf • 0.05 MB
Existing Cable trench layout.pdf
pdf • 0.33 MB
Existing Cable trench.pdf
pdf • 1.47 MB
Existing Earthing layout.pdf
pdf • 1.18 MB
Existing SAS architecture (2).jpg
jpg • 0.35 MB
Existing SAS architecture.jpg
jpg • 0.21 MB
Existing Vms Layout.pdf
pdf • 0.51 MB
GA Arasur.pdf
pdf • 0.25 MB
SLD Arasur.pdf
pdf • 0.29 MB
23.0 EHV XLPE cable Rev01.pdf
pdf • 0.60 MB
400kV Transformer specification_Rev 13.pdf
pdf • 4.54 MB
Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
Section-Sub-station Automation_STANDARD FACTORY SIMULATION TEST PLAN.pdf
pdf • 0.54 MB
Section-Switchgear-CB_Rev11.pdf
pdf • 0.61 MB
Section-Switchgear-INST_rev11.pdf
pdf • 1.00 MB
Section-Switchgear-ISO_Rev12.pdf
pdf • 0.17 MB
Section-Switchgear-SA_Rev12.pdf
pdf • 0.34 MB
15.0 TS Civil Works Rev 11A with correction slips.pdf
pdf • 4.56 MB
16.0 Section Structure Rev 6.pdf
pdf • 0.10 MB
17.0 Lighting Specification Rev.07.pdf
pdf • 4.29 MB
10.0 Air conditioning R4.pdf
pdf • 0.04 MB
11.0 Section_Switchyard Erection_Rev.10.pdf
pdf • 5.99 MB
12.0 CRP Rev 09.pdf
pdf • 0.37 MB
9.0 Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
1.0 GTR Rev 15 .pdf
pdf • 7.12 MB
5.0 LT Switchgear R5.pdf
pdf • 0.47 MB
8.0 Fire Protection Rev 6.pdf
pdf • 1.97 MB
Annex-I List of Drawings.pdf
pdf • 0.19 MB
Annexure II Specific Requirement_Rev 07 with Annexures.pdf
pdf • 7.51 MB
Annexure-III to section project Mandatory spares.pdf
pdf • 0.11 MB
Annexure-IV to section project NTAMC aug.pdf
pdf • 0.16 MB
Section project- SS100rev.pdf
pdf • 0.45 MB
Price_schedule.xlsx
xlsx • 0.89 MB
[Content_Types].xml
xml • 0.01 MB
.rels
rels • 0.00 MB
workbook.xml.rels
rels • 0.01 MB
workbook.xml
xml • 0.25 MB
sheet4.xml
xml • 0.04 MB
drawing25.xml
xml • 0.00 MB
drawing24.xml
xml • 0.00 MB
drawing23.xml
xml • 0.00 MB
drawing22.xml
xml • 0.00 MB
drawing21.xml
xml • 0.00 MB
vmlDrawing5.vml
vml • 0.00 MB
drawing20.xml
xml • 0.01 MB
drawing19.xml
xml • 0.00 MB
drawing18.xml
xml • 0.00 MB
drawing26.xml
xml • 0.00 MB
vbaProject.bin
bin • 0.13 MB
sheet3.xml
xml • 0.03 MB
sheet7.xml.rels
rels • 0.01 MB
sheet6.xml.rels
rels • 0.01 MB
sheet5.xml.rels
rels • 0.01 MB
sheet4.xml.rels
rels • 0.01 MB
sheet3.xml.rels
rels • 0.01 MB
sheet2.xml.rels
rels • 0.01 MB
sheet1.xml.rels
rels • 0.01 MB
sheet2.xml
xml • 0.02 MB
drawing17.xml
xml • 0.00 MB
drawing16.xml
xml • 0.01 MB
drawing15.xml
xml • 0.00 MB
drawing6.xml
xml • 0.00 MB
drawing5.xml
xml • 0.00 MB
vmlDrawing1.vml
vml • 0.01 MB
drawing4.xml
xml • 0.04 MB
drawing3.xml
xml • 0.00 MB
drawing2.xml
xml • 0.00 MB
image2.png
png • 0.07 MB
image1.png
png • 0.03 MB
drawing7.xml
xml • 0.00 MB
drawing8.xml
xml • 0.01 MB
vmlDrawing2.vml
vml • 0.00 MB
drawing14.xml
xml • 0.00 MB
drawing13.xml
xml • 0.00 MB
drawing12.xml
xml • 0.00 MB
drawing11.xml
xml • 0.01 MB
vmlDrawing4.vml
vml • 0.00 MB
drawing10.xml
xml • 0.00 MB
vmlDrawing3.vml
vml • 0.00 MB
drawing9.xml
xml • 0.00 MB
sheet8.xml.rels
rels • 0.01 MB
sheet9.xml.rels
rels • 0.01 MB
sheet10.xml.rels
rels • 0.00 MB
drawing15.xml.rels
rels • 0.00 MB
drawing14.xml.rels
rels • 0.00 MB
drawing13.xml.rels
rels • 0.00 MB
drawing12.xml.rels
rels • 0.00 MB
drawing11.xml.rels
rels • 0.00 MB
drawing8.xml.rels
rels • 0.00 MB
drawing7.xml.rels
rels • 0.00 MB
drawing6.xml.rels
rels • 0.00 MB
drawing5.xml.rels
rels • 0.00 MB
drawing16.xml.rels
rels • 0.00 MB
drawing17.xml.rels
rels • 0.00 MB
drawing18.xml.rels
rels • 0.00 MB
drawing26.xml.rels
rels • 0.00 MB
drawing25.xml.rels
rels • 0.00 MB
drawing24.xml.rels
rels • 0.00 MB
drawing23.xml.rels
rels • 0.00 MB
drawing22.xml.rels
rels • 0.00 MB
drawing21.xml.rels
rels • 0.00 MB
drawing20.xml.rels
rels • 0.00 MB
drawing19.xml.rels
rels • 0.00 MB
drawing4.xml.rels
rels • 0.00 MB
drawing3.xml.rels
rels • 0.00 MB
drawing2.xml.rels
rels • 0.00 MB
sheet18.xml.rels
rels • 0.01 MB
sheet17.xml.rels
rels • 0.00 MB
sheet16.xml.rels
rels • 0.01 MB
sheet15.xml.rels
rels • 0.01 MB
sheet14.xml.rels
rels • 0.01 MB
sheet13.xml.rels
rels • 0.01 MB
sheet12.xml.rels
rels • 0.01 MB
sheet11.xml.rels
rels • 0.00 MB
sheet19.xml.rels
rels • 0.01 MB
sheet20.xml.rels
rels • 0.01 MB
sheet21.xml.rels
rels • 0.01 MB
drawing1.xml.rels
rels • 0.00 MB
sheet28.xml.rels
rels • 0.01 MB
sheet27.xml.rels
rels • 0.01 MB
sheet26.xml.rels
rels • 0.00 MB
sheet25.xml.rels
rels • 0.01 MB
sheet24.xml.rels
rels • 0.00 MB
sheet23.xml.rels
rels • 0.01 MB
sheet22.xml.rels
rels • 0.01 MB
drawing1.xml
xml • 0.01 MB
sheet1.xml
xml • 0.01 MB
theme1.xml
xml • 0.01 MB
styles.xml
xml • 0.27 MB
sheet22.xml
xml • 0.08 MB
sheet21.xml
xml • 0.08 MB
sheet20.xml
xml • 0.08 MB
sheet19.xml
xml • 0.02 MB
sheet24.xml
xml • 0.02 MB
sheet25.xml
xml • 0.03 MB
sheet26.xml
xml • 0.01 MB
sharedStrings.xml
xml • 0.07 MB
sheet29.xml
xml • 0.01 MB
sheet28.xml
xml • 0.02 MB
sheet27.xml
xml • 0.12 MB
sheet18.xml
xml • 0.02 MB
sheet23.xml
xml • 0.04 MB
sheet16.xml
xml • 0.04 MB
sheet8.xml
xml • 0.03 MB
sheet7.xml
xml • 0.03 MB
sheet6.xml
xml • 0.03 MB
sheet5.xml
xml • 0.16 MB
sheet9.xml
xml • 0.03 MB
sheet17.xml
xml • 0.03 MB
sheet11.xml
xml • 0.01 MB
sheet15.xml
xml • 0.02 MB
sheet14.xml
xml • 0.04 MB
sheet10.xml
xml • 0.02 MB
sheet12.xml
xml • 0.03 MB
sheet13.xml
xml • 0.02 MB
printerSettings625.bin
bin • 0.01 MB
printerSettings633.bin
bin • 0.01 MB
printerSettings635.bin
bin • 0.01 MB
printerSettings624.bin
bin • 0.01 MB
printerSettings56.bin
bin • 0.01 MB
printerSettings634.bin
bin • 0.01 MB
printerSettings631.bin
bin • 0.01 MB
printerSettings630.bin
bin • 0.01 MB
printerSettings626.bin
bin • 0.01 MB
printerSettings627.bin
bin • 0.01 MB
printerSettings628.bin
bin • 0.01 MB
printerSettings629.bin
bin • 0.01 MB
printerSettings632.bin
bin • 0.01 MB
printerSettings645.bin
bin • 0.01 MB
printerSettings637.bin
bin • 0.01 MB
printerSettings644.bin
bin • 0.01 MB
printerSettings623.bin
bin • 0.01 MB
printerSettings646.bin
bin • 0.01 MB
printerSettings647.bin
bin • 0.01 MB
printerSettings643.bin
bin • 0.01 MB
printerSettings642.bin
bin • 0.01 MB
printerSettings641.bin
bin • 0.01 MB
printerSettings638.bin
bin • 0.01 MB
printerSettings639.bin
bin • 0.01 MB
printerSettings30.bin
bin • 0.01 MB
printerSettings640.bin
bin • 0.01 MB
printerSettings636.bin
bin • 0.01 MB
printerSettings648.bin
bin • 0.01 MB
printerSettings621.bin
bin • 0.01 MB
printerSettings604.bin
bin • 0.01 MB
printerSettings605.bin
bin • 0.01 MB
printerSettings606.bin
bin • 0.01 MB
printerSettings607.bin
bin • 0.01 MB
printerSettings603.bin
bin • 0.01 MB
printerSettings602.bin
bin • 0.01 MB
printerSettings601.bin
bin • 0.01 MB
printerSettings597.bin
bin • 0.01 MB
printerSettings598.bin
bin • 0.01 MB
printerSettings599.bin
bin • 0.01 MB
printerSettings600.bin
bin • 0.01 MB
printerSettings31.bin
bin • 0.01 MB
printerSettings608.bin
bin • 0.01 MB
printerSettings609.bin
bin • 0.01 MB
printerSettings617.bin
bin • 0.01 MB
printerSettings618.bin
bin • 0.00 MB
printerSettings619.bin
bin • 0.01 MB
printerSettings620.bin
bin • 0.01 MB
printerSettings616.bin
bin • 0.01 MB
printerSettings615.bin
bin • 0.01 MB
printerSettings614.bin
bin • 0.01 MB
printerSettings610.bin
bin • 0.01 MB
printerSettings611.bin
bin • 0.01 MB
printerSettings612.bin
bin • 0.01 MB
printerSettings613.bin
bin • 0.01 MB
printerSettings622.bin
bin • 0.01 MB
printerSettings663.bin
bin • 0.01 MB
printerSettings650.bin
bin • 0.00 MB
printerSettings682.bin
bin • 0.01 MB
printerSettings683.bin
bin • 0.01 MB
printerSettings684.bin
bin • 0.00 MB
printerSettings685.bin
bin • 0.01 MB
printerSettings681.bin
bin • 0.01 MB
printerSettings680.bin
bin • 0.01 MB
printerSettings679.bin
bin • 0.01 MB
printerSettings675.bin
bin • 0.01 MB
printerSettings676.bin
bin • 0.01 MB
printerSettings677.bin
bin • 0.01 MB
printerSettings678.bin
bin • 0.01 MB
printerSettings686.bin
bin • 0.00 MB
printerSettings687.bin
bin • 0.00 MB
printerSettings688.bin
bin • 0.00 MB
printerSettings696.bin
bin • 0.01 MB
printerSettings697.bin
bin • 0.01 MB
printerSettings698.bin
bin • 0.01 MB
printerSettings699.bin
bin • 0.01 MB
printerSettings695.bin
bin • 0.01 MB
printerSettings694.bin
bin • 0.01 MB
printerSettings693.bin
bin • 0.00 MB
printerSettings689.bin
bin • 0.01 MB
printerSettings690.bin
bin • 0.01 MB
printerSettings691.bin
bin • 0.00 MB
printerSettings692.bin
bin • 0.00 MB
printerSettings674.bin
bin • 0.01 MB
ctrlProp23.xml
xml • 0.00 MB
ctrlProp22.xml
xml • 0.00 MB
printerSettings658.bin
bin • 0.01 MB
printerSettings659.bin
bin • 0.01 MB
printerSettings660.bin
bin • 0.01 MB
printerSettings661.bin
bin • 0.01 MB
printerSettings657.bin
bin • 0.01 MB
printerSettings656.bin
bin • 0.00 MB
printerSettings655.bin
bin • 0.00 MB
printerSettings651.bin
bin • 0.01 MB
printerSettings652.bin
bin • 0.00 MB
printerSettings653.bin
bin • 0.01 MB
printerSettings654.bin
bin • 0.01 MB
printerSettings662.bin
bin • 0.01 MB
printerSettings596.bin
bin • 0.01 MB
printerSettings664.bin
bin • 0.01 MB
printerSettings672.bin
bin • 0.01 MB
printerSettings673.bin
bin • 0.01 MB
printerSettings29.bin
bin • 0.01 MB
printerSettings28.bin
bin • 0.01 MB
printerSettings671.bin
bin • 0.01 MB
printerSettings670.bin
bin • 0.01 MB
printerSettings669.bin
bin • 0.01 MB
printerSettings665.bin
bin • 0.01 MB
printerSettings666.bin
bin • 0.01 MB
printerSettings667.bin
bin • 0.01 MB
printerSettings668.bin
bin • 0.01 MB
printerSettings649.bin
bin • 0.01 MB
printerSettings581.bin
bin • 0.01 MB
printerSettings594.bin
bin • 0.01 MB
printerSettings524.bin
bin • 0.01 MB
printerSettings525.bin
bin • 0.01 MB
printerSettings526.bin
bin • 0.01 MB
printerSettings527.bin
bin • 0.01 MB
printerSettings523.bin
bin • 0.01 MB
printerSettings522.bin
bin • 0.01 MB
printerSettings521.bin
bin • 0.01 MB
printerSettings517.bin
bin • 0.00 MB
printerSettings518.bin
bin • 0.01 MB
printerSettings519.bin
bin • 0.01 MB
printerSettings520.bin
bin • 0.01 MB
printerSettings528.bin
bin • 0.01 MB
printerSettings529.bin
bin • 0.01 MB
printerSettings530.bin
bin • 0.01 MB
printerSettings537.bin
bin • 0.01 MB
printerSettings538.bin
bin • 0.01 MB
printerSettings33.bin
bin • 0.01 MB
printerSettings539.bin
bin • 0.01 MB
printerSettings536.bin
bin • 0.01 MB
printerSettings535.bin
bin • 0.01 MB
printerSettings34.bin
bin • 0.01 MB
printerSettings531.bin
bin • 0.01 MB
printerSettings532.bin
bin • 0.01 MB
printerSettings533.bin
bin • 0.01 MB
printerSettings534.bin
bin • 0.01 MB
printerSettings516.bin
bin • 0.00 MB
printerSettings515.bin
bin • 0.00 MB
printerSettings514.bin
bin • 0.01 MB
printerSettings497.bin
bin • 0.01 MB
printerSettings35.bin
bin • 0.01 MB
printerSettings498.bin
bin • 0.01 MB
printerSettings499.bin
bin • 0.01 MB
printerSettings496.bin
bin • 0.01 MB
printerSettings495.bin
bin • 0.01 MB
printerSettings494.bin
bin • 0.01 MB
printerSettings490.bin
bin • 0.01 MB
printerSettings491.bin
bin • 0.01 MB
printerSettings492.bin
bin • 0.01 MB
printerSettings493.bin
bin • 0.01 MB
printerSettings500.bin
bin • 0.01 MB
printerSettings501.bin
bin • 0.01 MB
printerSettings502.bin
bin • 0.01 MB
printerSettings510.bin
bin • 0.00 MB
printerSettings511.bin
bin • 0.00 MB
printerSettings512.bin
bin • 0.00 MB
printerSettings513.bin
bin • 0.01 MB
printerSettings509.bin
bin • 0.01 MB
printerSettings508.bin
bin • 0.00 MB
printerSettings507.bin
bin • 0.01 MB
printerSettings503.bin
bin • 0.01 MB
printerSettings504.bin
bin • 0.01 MB
printerSettings505.bin
bin • 0.01 MB
printerSettings506.bin
bin • 0.01 MB
printerSettings540.bin
bin • 0.01 MB
printerSettings541.bin
bin • 0.01 MB
printerSettings542.bin
bin • 0.01 MB
printerSettings576.bin
bin • 0.01 MB
printerSettings577.bin
bin • 0.01 MB
printerSettings578.bin
bin • 0.01 MB
printerSettings579.bin
bin • 0.01 MB
printerSettings32.bin
bin • 0.01 MB
printerSettings575.bin
bin • 0.01 MB
printerSettings574.bin
bin • 0.01 MB
printerSettings570.bin
bin • 0.01 MB
printerSettings571.bin
bin • 0.01 MB
printerSettings572.bin
bin • 0.01 MB
printerSettings573.bin
bin • 0.01 MB
printerSettings580.bin
bin • 0.01 MB
printerSettings700.bin
bin • 0.01 MB
printerSettings582.bin
bin • 0.01 MB
printerSettings590.bin
bin • 0.01 MB
printerSettings591.bin
bin • 0.01 MB
printerSettings592.bin
bin • 0.01 MB
printerSettings593.bin
bin • 0.01 MB
printerSettings589.bin
bin • 0.01 MB
printerSettings588.bin
bin • 0.00 MB
printerSettings587.bin
bin • 0.01 MB
printerSettings583.bin
bin • 0.01 MB
printerSettings584.bin
bin • 0.01 MB
printerSettings585.bin
bin • 0.01 MB
printerSettings586.bin
bin • 0.00 MB
printerSettings569.bin
bin • 0.01 MB
printerSettings568.bin
bin • 0.01 MB
printerSettings567.bin
bin • 0.01 MB
printerSettings550.bin
bin • 0.01 MB
printerSettings551.bin
bin • 0.00 MB
printerSettings552.bin
bin • 0.00 MB
printerSettings553.bin
bin • 0.00 MB
printerSettings549.bin
bin • 0.00 MB
printerSettings548.bin
bin • 0.01 MB
printerSettings547.bin
bin • 0.01 MB
printerSettings543.bin
bin • 0.01 MB
printerSettings544.bin
bin • 0.01 MB
printerSettings545.bin
bin • 0.01 MB
printerSettings546.bin
bin • 0.01 MB
printerSettings554.bin
bin • 0.01 MB
printerSettings555.bin
bin • 0.01 MB
printerSettings556.bin
bin • 0.00 MB
printerSettings563.bin
bin • 0.01 MB
printerSettings564.bin
bin • 0.01 MB
printerSettings565.bin
bin • 0.01 MB
printerSettings566.bin
bin • 0.01 MB
printerSettings562.bin
bin • 0.01 MB
printerSettings561.bin
bin • 0.01 MB
printerSettings560.bin
bin • 0.01 MB
printerSettings559.bin
bin • 0.01 MB
printerSettings558.bin
bin • 0.01 MB
printerSettings557.bin
bin • 0.01 MB
printerSettings595.bin
bin • 0.01 MB
printerSettings714.bin
bin • 0.01 MB
printerSettings702.bin
bin • 0.01 MB
printerSettings843.bin
bin • 0.01 MB
printerSettings844.bin
bin • 0.01 MB
printerSettings845.bin
bin • 0.01 MB
printerSettings846.bin
bin • 0.01 MB
printerSettings22.bin
bin • 0.01 MB
printerSettings842.bin
bin • 0.01 MB
printerSettings841.bin
bin • 0.01 MB
printerSettings837.bin
bin • 0.01 MB
printerSettings838.bin
bin • 0.01 MB
printerSettings839.bin
bin • 0.01 MB
printerSettings840.bin
bin • 0.01 MB
printerSettings847.bin
bin • 0.01 MB
printerSettings848.bin
bin • 0.01 MB
printerSettings849.bin
bin • 0.01 MB
printerSettings857.bin
bin • 0.01 MB
printerSettings858.bin
bin • 0.01 MB
printerSettings859.bin
bin • 0.01 MB
printerSettings860.bin
bin • 0.01 MB
printerSettings856.bin
bin • 0.01 MB
printerSettings855.bin
bin • 0.01 MB
printerSettings854.bin
bin • 0.01 MB
printerSettings850.bin
bin • 0.01 MB
printerSettings851.bin
bin • 0.01 MB
printerSettings852.bin
bin • 0.01 MB
printerSettings853.bin
bin • 0.01 MB
printerSettings836.bin
bin • 0.01 MB
printerSettings835.bin
bin • 0.01 MB
printerSettings834.bin
bin • 0.01 MB
printerSettings816.bin
bin • 0.01 MB
printerSettings817.bin
bin • 0.01 MB
printerSettings818.bin
bin • 0.01 MB
printerSettings819.bin
bin • 0.01 MB
printerSettings815.bin
bin • 0.01 MB
printerSettings814.bin
bin • 0.01 MB
printerSettings813.bin
bin • 0.01 MB
printerSettings23.bin
bin • 0.01 MB
printerSettings810.bin
bin • 0.01 MB
printerSettings811.bin
bin • 0.01 MB
printerSettings812.bin
bin • 0.01 MB
printerSettings820.bin
bin • 0.00 MB
printerSettings821.bin
bin • 0.01 MB
printerSettings822.bin
bin • 0.00 MB
printerSettings830.bin
bin • 0.01 MB
printerSettings831.bin
bin • 0.01 MB
printerSettings832.bin
bin • 0.01 MB
printerSettings833.bin
bin • 0.01 MB
printerSettings829.bin
bin • 0.01 MB
printerSettings828.bin
bin • 0.01 MB
printerSettings827.bin
bin • 0.01 MB
printerSettings823.bin
bin • 0.01 MB
printerSettings824.bin
bin • 0.01 MB
printerSettings825.bin
bin • 0.01 MB
printerSettings826.bin
bin • 0.01 MB
printerSettings861.bin
bin • 0.01 MB
printerSettings862.bin
bin • 0.01 MB
printerSettings863.bin
bin • 0.01 MB
printerSettings5.bin
bin • 0.01 MB
printerSettings4.bin
bin • 0.01 MB
printerSettings3.bin
bin • 0.01 MB
printerSettings2.bin
bin • 0.01 MB
printerSettings6.bin
bin • 0.01 MB
printerSettings7.bin
bin • 0.01 MB
printerSettings8.bin
bin • 0.01 MB
printerSettings12.bin
bin • 0.01 MB
printerSettings11.bin
bin • 0.01 MB
printerSettings10.bin
bin • 0.01 MB
printerSettings9.bin
bin • 0.01 MB
printerSettings1.bin
bin • 0.01 MB
externalLink6.xml
xml • 0.00 MB
externalLink5.xml
xml • 0.00 MB
externalLink4.xml.rels
rels • 0.00 MB
externalLink5.xml.rels
rels • 0.00 MB
externalLink6.xml.rels
rels • 0.00 MB
revisionHeaders.xml.rels
rels • 0.00 MB
externalLink3.xml.rels
rels • 0.00 MB
externalLink2.xml.rels
rels • 0.00 MB
externalLink1.xml.rels
rels • 0.00 MB
externalLink4.xml
xml • 0.00 MB
externalLink3.xml
xml • 0.00 MB
externalLink2.xml
xml • 0.01 MB
externalLink1.xml
xml • 0.00 MB
printerSettings13.bin
bin • 0.01 MB
printerSettings14.bin
bin • 0.01 MB
printerSettings15.bin
bin • 0.01 MB
printerSettings871.bin
bin • 0.01 MB
printerSettings872.bin
bin • 0.01 MB
printerSettings873.bin
bin • 0.01 MB
printerSettings874.bin
bin • 0.01 MB
printerSettings870.bin
bin • 0.01 MB
printerSettings869.bin
bin • 0.01 MB
printerSettings868.bin
bin • 0.01 MB
printerSettings864.bin
bin • 0.01 MB
printerSettings865.bin
bin • 0.01 MB
printerSettings866.bin
bin • 0.01 MB
printerSettings867.bin
bin • 0.01 MB
printerSettings875.bin
bin • 0.01 MB
calcChain.xml
xml • 0.01 MB
printerSettings21.bin
bin • 0.01 MB
printerSettings19.bin
bin • 0.01 MB
printerSettings18.bin
bin • 0.01 MB
printerSettings17.bin
bin • 0.01 MB
printerSettings16.bin
bin • 0.01 MB
printerSettings20.bin
bin • 0.01 MB
app.xml
xml • 0.00 MB
core.xml
xml • 0.00 MB
userNames.xml
xml • 0.00 MB
revisionLog1.xml
xml • 0.00 MB
revisionHeaders.xml
xml • 0.00 MB
printerSettings809.bin
bin • 0.01 MB
printerSettings808.bin
bin • 0.01 MB
printerSettings807.bin
bin • 0.01 MB
printerSettings737.bin
bin • 0.01 MB
printerSettings738.bin
bin • 0.01 MB
printerSettings739.bin
bin • 0.01 MB
printerSettings740.bin
bin • 0.01 MB
printerSettings736.bin
bin • 0.01 MB
printerSettings735.bin
bin • 0.01 MB
printerSettings734.bin
bin • 0.01 MB
printerSettings730.bin
bin • 0.01 MB
printerSettings731.bin
bin • 0.01 MB
printerSettings732.bin
bin • 0.01 MB
printerSettings733.bin
bin • 0.01 MB
printerSettings741.bin
bin • 0.01 MB
printerSettings26.bin
bin • 0.01 MB
printerSettings742.bin
bin • 0.01 MB
printerSettings750.bin
bin • 0.01 MB
printerSettings751.bin
bin • 0.01 MB
printerSettings752.bin
bin • 0.01 MB
printerSettings753.bin
bin • 0.01 MB
printerSettings749.bin
bin • 0.01 MB
printerSettings748.bin
bin • 0.01 MB
printerSettings747.bin
bin • 0.01 MB
printerSettings743.bin
bin • 0.01 MB
printerSettings744.bin
bin • 0.01 MB
printerSettings745.bin
bin • 0.01 MB
printerSettings746.bin
bin • 0.01 MB
printerSettings729.bin
bin • 0.01 MB
printerSettings728.bin
bin • 0.01 MB
printerSettings727.bin
bin • 0.01 MB
printerSettings710.bin
bin • 0.01 MB
printerSettings27.bin
bin • 0.01 MB
printerSettings711.bin
bin • 0.01 MB
printerSettings712.bin
bin • 0.01 MB
printerSettings709.bin
bin • 0.01 MB
printerSettings708.bin
bin • 0.01 MB
printerSettings707.bin
bin • 0.01 MB
printerSettings703.bin
bin • 0.01 MB
printerSettings704.bin
bin • 0.01 MB
printerSettings705.bin
bin • 0.01 MB
printerSettings706.bin
bin • 0.01 MB
printerSettings713.bin
bin • 0.01 MB
printerSettings489.bin
bin • 0.01 MB
printerSettings715.bin
bin • 0.01 MB
printerSettings723.bin
bin • 0.01 MB
printerSettings724.bin
bin • 0.00 MB
printerSettings725.bin
bin • 0.01 MB
printerSettings726.bin
bin • 0.01 MB
printerSettings722.bin
bin • 0.01 MB
printerSettings721.bin
bin • 0.00 MB
printerSettings720.bin
bin • 0.01 MB
printerSettings716.bin
bin • 0.01 MB
printerSettings717.bin
bin • 0.01 MB
printerSettings718.bin
bin • 0.01 MB
printerSettings719.bin
bin • 0.01 MB
printerSettings754.bin
bin • 0.01 MB
printerSettings755.bin
bin • 0.01 MB
printerSettings756.bin
bin • 0.01 MB
printerSettings790.bin
bin • 0.01 MB
printerSettings791.bin
bin • 0.01 MB
printerSettings792.bin
bin • 0.01 MB
printerSettings793.bin
bin • 0.01 MB
printerSettings789.bin
bin • 0.01 MB
printerSettings788.bin
bin • 0.01 MB
printerSettings787.bin
bin • 0.01 MB
printerSettings783.bin
bin • 0.01 MB
printerSettings784.bin
bin • 0.00 MB
printerSettings785.bin
bin • 0.00 MB
printerSettings786.bin
bin • 0.00 MB
printerSettings794.bin
bin • 0.01 MB
printerSettings795.bin
bin • 0.01 MB
printerSettings796.bin
bin • 0.01 MB
printerSettings24.bin
bin • 0.01 MB
printerSettings804.bin
bin • 0.01 MB
printerSettings805.bin
bin • 0.01 MB
printerSettings806.bin
bin • 0.01 MB
printerSettings803.bin
bin • 0.01 MB
printerSettings802.bin
bin • 0.01 MB
printerSettings801.bin
bin • 0.01 MB
printerSettings797.bin
bin • 0.01 MB
printerSettings798.bin
bin • 0.01 MB
printerSettings799.bin
bin • 0.01 MB
printerSettings800.bin
bin • 0.01 MB
printerSettings782.bin
bin • 0.01 MB
printerSettings781.bin
bin • 0.00 MB
printerSettings780.bin
bin • 0.00 MB
printerSettings764.bin
bin • 0.01 MB
printerSettings765.bin
bin • 0.01 MB
printerSettings766.bin
bin • 0.01 MB
printerSettings25.bin
bin • 0.01 MB
printerSettings763.bin
bin • 0.01 MB
printerSettings762.bin
bin • 0.01 MB
printerSettings761.bin
bin • 0.01 MB
printerSettings757.bin
bin • 0.01 MB
printerSettings758.bin
bin • 0.01 MB
printerSettings759.bin
bin • 0.01 MB
printerSettings760.bin
bin • 0.01 MB
printerSettings767.bin
bin • 0.01 MB
printerSettings768.bin
bin • 0.01 MB
printerSettings769.bin
bin • 0.01 MB
printerSettings776.bin
bin • 0.01 MB
printerSettings777.bin
bin • 0.00 MB
printerSettings778.bin
bin • 0.01 MB
printerSettings779.bin
bin • 0.01 MB
printerSettings775.bin
bin • 0.01 MB
printerSettings774.bin
bin • 0.01 MB
printerSettings773.bin
bin • 0.01 MB
printerSettings772.bin
bin • 0.01 MB
printerSettings771.bin
bin • 0.01 MB
printerSettings770.bin
bin • 0.01 MB
printerSettings701.bin
bin • 0.01 MB
printerSettings488.bin
bin • 0.01 MB
printerSettings487.bin
bin • 0.01 MB
printerSettings187.bin
bin • 0.01 MB
printerSettings188.bin
bin • 0.01 MB
printerSettings189.bin
bin • 0.01 MB
printerSettings190.bin
bin • 0.01 MB
printerSettings191.bin
bin • 0.01 MB
printerSettings186.bin
bin • 0.01 MB
printerSettings185.bin
bin • 0.01 MB
printerSettings184.bin
bin • 0.01 MB
printerSettings180.bin
bin • 0.00 MB
printerSettings181.bin
bin • 0.01 MB
printerSettings182.bin
bin • 0.01 MB
printerSettings183.bin
bin • 0.00 MB
printerSettings192.bin
bin • 0.01 MB
printerSettings193.bin
bin • 0.01 MB
printerSettings194.bin
bin • 0.01 MB
printerSettings202.bin
bin • 0.01 MB
printerSettings47.bin
bin • 0.01 MB
printerSettings203.bin
bin • 0.01 MB
printerSettings204.bin
bin • 0.01 MB
printerSettings205.bin
bin • 0.01 MB
printerSettings201.bin
bin • 0.01 MB
printerSettings200.bin
bin • 0.01 MB
printerSettings199.bin
bin • 0.01 MB
printerSettings195.bin
bin • 0.01 MB
printerSettings196.bin
bin • 0.01 MB
printerSettings197.bin
bin • 0.01 MB
printerSettings198.bin
bin • 0.01 MB
printerSettings179.bin
bin • 0.00 MB
printerSettings178.bin
bin • 0.00 MB
printerSettings177.bin
bin • 0.01 MB
ctrlProp10.xml
xml • 0.00 MB
ctrlProp11.xml
xml • 0.00 MB
ctrlProp12.xml
xml • 0.00 MB
ctrlProp13.xml
xml • 0.00 MB
ctrlProp14.xml
xml • 0.00 MB
ctrlProp9.xml
xml • 0.00 MB
ctrlProp8.xml
xml • 0.00 MB
ctrlProp7.xml
xml • 0.00 MB
ctrlProp3.xml
xml • 0.00 MB
ctrlProp4.xml
xml • 0.00 MB
ctrlProp5.xml
xml • 0.00 MB
ctrlProp6.xml
xml • 0.00 MB
ctrlProp15.xml
xml • 0.00 MB
ctrlProp16.xml
xml • 0.00 MB
ctrlProp17.xml
xml • 0.00 MB
printerSettings172.bin
bin • 0.01 MB
printerSettings173.bin
bin • 0.01 MB
printerSettings174.bin
bin • 0.01 MB
printerSettings175.bin
bin • 0.01 MB
printerSettings176.bin
bin • 0.00 MB
printerSettings171.bin
bin • 0.01 MB
printerSettings170.bin
bin • 0.01 MB
printerSettings169.bin
bin • 0.01 MB
ctrlProp18.xml
xml • 0.00 MB
printerSettings166.bin
bin • 0.01 MB
printerSettings167.bin
bin • 0.01 MB
printerSettings168.bin
bin • 0.01 MB
printerSettings206.bin
bin • 0.01 MB
printerSettings207.bin
bin • 0.01 MB
printerSettings208.bin
bin • 0.01 MB
printerSettings244.bin
bin • 0.01 MB
printerSettings245.bin
bin • 0.01 MB
printerSettings246.bin
bin • 0.01 MB
printerSettings247.bin
bin • 0.01 MB
printerSettings248.bin
bin • 0.01 MB
printerSettings243.bin
bin • 0.01 MB
printerSettings242.bin
bin • 0.01 MB
printerSettings241.bin
bin • 0.01 MB
printerSettings238.bin
bin • 0.01 MB
printerSettings239.bin
bin • 0.01 MB
printerSettings46.bin
bin • 0.01 MB
printerSettings240.bin
bin • 0.01 MB
printerSettings249.bin
bin • 0.01 MB
printerSettings250.bin
bin • 0.00 MB
printerSettings251.bin
bin • 0.01 MB
printerSettings259.bin
bin • 0.01 MB
printerSettings260.bin
bin • 0.01 MB
printerSettings261.bin
bin • 0.01 MB
printerSettings262.bin
bin • 0.01 MB
printerSettings263.bin
bin • 0.01 MB
printerSettings258.bin
bin • 0.01 MB
printerSettings257.bin
bin • 0.00 MB
printerSettings256.bin
bin • 0.01 MB
printerSettings252.bin
bin • 0.00 MB
printerSettings253.bin
bin • 0.00 MB
printerSettings254.bin
bin • 0.00 MB
printerSettings255.bin
bin • 0.01 MB
printerSettings237.bin
bin • 0.01 MB
printerSettings236.bin
bin • 0.01 MB
printerSettings235.bin
bin • 0.01 MB
printerSettings216.bin
bin • 0.00 MB
printerSettings217.bin
bin • 0.00 MB
printerSettings218.bin
bin • 0.01 MB
printerSettings219.bin
bin • 0.01 MB
printerSettings220.bin
bin • 0.00 MB
printerSettings215.bin
bin • 0.00 MB
printerSettings214.bin
bin • 0.01 MB
printerSettings213.bin
bin • 0.00 MB
printerSettings209.bin
bin • 0.01 MB
printerSettings210.bin
bin • 0.01 MB
printerSettings211.bin
bin • 0.01 MB
printerSettings212.bin
bin • 0.01 MB
printerSettings221.bin
bin • 0.01 MB
printerSettings222.bin
bin • 0.01 MB
printerSettings223.bin
bin • 0.01 MB
printerSettings231.bin
bin • 0.01 MB
printerSettings232.bin
bin • 0.01 MB
printerSettings233.bin
bin • 0.01 MB
printerSettings234.bin
bin • 0.01 MB
printerSettings230.bin
bin • 0.01 MB
printerSettings229.bin
bin • 0.01 MB
printerSettings228.bin
bin • 0.01 MB
printerSettings224.bin
bin • 0.01 MB
printerSettings225.bin
bin • 0.01 MB
printerSettings226.bin
bin • 0.01 MB
printerSettings227.bin
bin • 0.01 MB
ctrlProp2.xml
xml • 0.00 MB
ctrlProp1.xml
xml • 0.00 MB
printerSettings48.bin
bin • 0.01 MB
printerSettings90.bin
bin • 0.01 MB
printerSettings91.bin
bin • 0.01 MB
printerSettings92.bin
bin • 0.00 MB
printerSettings93.bin
bin • 0.01 MB
printerSettings94.bin
bin • 0.01 MB
printerSettings89.bin
bin • 0.00 MB
printerSettings88.bin
bin • 0.00 MB
printerSettings87.bin
bin • 0.01 MB
printerSettings83.bin
bin • 0.01 MB
printerSettings84.bin
bin • 0.01 MB
printerSettings85.bin
bin • 0.00 MB
printerSettings86.bin
bin • 0.01 MB
printerSettings95.bin
bin • 0.01 MB
printerSettings96.bin
bin • 0.01 MB
printerSettings97.bin
bin • 0.01 MB
printerSettings105.bin
bin • 0.01 MB
printerSettings106.bin
bin • 0.01 MB
printerSettings107.bin
bin • 0.01 MB
printerSettings108.bin
bin • 0.01 MB
printerSettings109.bin
bin • 0.01 MB
printerSettings104.bin
bin • 0.01 MB
printerSettings103.bin
bin • 0.01 MB
printerSettings102.bin
bin • 0.01 MB
printerSettings98.bin
bin • 0.01 MB
printerSettings99.bin
bin • 0.01 MB
printerSettings100.bin
bin • 0.01 MB
printerSettings101.bin
bin • 0.01 MB
printerSettings82.bin
bin • 0.01 MB
printerSettings81.bin
bin • 0.01 MB
printerSettings80.bin
bin • 0.01 MB
printerSettings64.bin
bin • 0.01 MB
printerSettings65.bin
bin • 0.01 MB
printerSettings66.bin
bin • 0.01 MB
printerSettings67.bin
bin • 0.01 MB
printerSettings68.bin
bin • 0.01 MB
printerSettings63.bin
bin • 0.01 MB
printerSettings62.bin
bin • 0.01 MB
printerSettings61.bin
bin • 0.01 MB
printerSettings57.bin
bin • 0.01 MB
printerSettings58.bin
bin • 0.01 MB
printerSettings59.bin
bin • 0.01 MB
printerSettings60.bin
bin • 0.01 MB
printerSettings69.bin
bin • 0.01 MB
printerSettings70.bin
bin • 0.01 MB
printerSettings71.bin
bin • 0.01 MB
printerSettings76.bin
bin • 0.01 MB
printerSettings77.bin
bin • 0.01 MB
printerSettings78.bin
bin • 0.01 MB
printerSettings79.bin
bin • 0.01 MB
printerSettings75.bin
bin • 0.01 MB
printerSettings52.bin
bin • 0.00 MB
printerSettings53.bin
bin • 0.01 MB
printerSettings72.bin
bin • 0.01 MB
printerSettings73.bin
bin • 0.01 MB
printerSettings74.bin
bin • 0.01 MB
printerSettings54.bin
bin • 0.01 MB
printerSettings110.bin
bin • 0.01 MB
printerSettings111.bin
bin • 0.01 MB
printerSettings51.bin
bin • 0.00 MB
printerSettings148.bin
bin • 0.01 MB
printerSettings50.bin
bin • 0.01 MB
printerSettings149.bin
bin • 0.01 MB
printerSettings150.bin
bin • 0.01 MB
printerSettings151.bin
bin • 0.01 MB
printerSettings147.bin
bin • 0.01 MB
printerSettings146.bin
bin • 0.01 MB
printerSettings145.bin
bin • 0.01 MB
printerSettings141.bin
bin • 0.01 MB
printerSettings142.bin
bin • 0.01 MB
printerSettings143.bin
bin • 0.01 MB
printerSettings144.bin
bin • 0.01 MB
printerSettings152.bin
bin • 0.01 MB
printerSettings153.bin
bin • 0.01 MB
printerSettings154.bin
bin • 0.01 MB
printerSettings162.bin
bin • 0.01 MB
printerSettings163.bin
bin • 0.01 MB
printerSettings164.bin
bin • 0.01 MB
printerSettings165.bin
bin • 0.01 MB
printerSettings49.bin
bin • 0.01 MB
printerSettings161.bin
bin • 0.01 MB
printerSettings160.bin
bin • 0.01 MB
printerSettings159.bin
bin • 0.01 MB
printerSettings155.bin
bin • 0.01 MB
printerSettings156.bin
bin • 0.01 MB
printerSettings157.bin
bin • 0.01 MB
printerSettings158.bin
bin • 0.01 MB
printerSettings140.bin
bin • 0.01 MB
printerSettings139.bin
bin • 0.01 MB
printerSettings138.bin
bin • 0.01 MB
printerSettings119.bin
bin • 0.01 MB
printerSettings120.bin
bin • 0.01 MB
printerSettings121.bin
bin • 0.01 MB
printerSettings122.bin
bin • 0.00 MB
printerSettings123.bin
bin • 0.01 MB
printerSettings118.bin
bin • 0.01 MB
printerSettings117.bin
bin • 0.01 MB
printerSettings116.bin
bin • 0.01 MB
printerSettings112.bin
bin • 0.01 MB
printerSettings113.bin
bin • 0.01 MB
printerSettings114.bin
bin • 0.01 MB
printerSettings115.bin
bin • 0.01 MB
printerSettings124.bin
bin • 0.00 MB
printerSettings125.bin
bin • 0.00 MB
printerSettings126.bin
bin • 0.00 MB
printerSettings134.bin
bin • 0.01 MB
printerSettings135.bin
bin • 0.01 MB
printerSettings136.bin
bin • 0.01 MB
printerSettings137.bin
bin • 0.01 MB
printerSettings133.bin
bin • 0.01 MB
printerSettings132.bin
bin • 0.01 MB
printerSettings131.bin
bin • 0.01 MB
printerSettings127.bin
bin • 0.01 MB
printerSettings128.bin
bin • 0.01 MB
printerSettings129.bin
bin • 0.00 MB
printerSettings130.bin
bin • 0.01 MB
printerSettings264.bin
bin • 0.01 MB
printerSettings265.bin
bin • 0.01 MB
printerSettings266.bin
bin • 0.01 MB
printerSettings410.bin
bin • 0.01 MB
printerSettings411.bin
bin • 0.01 MB
printerSettings412.bin
bin • 0.01 MB
printerSettings413.bin
bin • 0.01 MB
printerSettings414.bin
bin • 0.01 MB
printerSettings409.bin
bin • 0.01 MB
printerSettings408.bin
bin • 0.01 MB
printerSettings407.bin
bin • 0.01 MB
printerSettings403.bin
bin • 0.01 MB
printerSettings404.bin
bin • 0.01 MB
printerSettings405.bin
bin • 0.01 MB
printerSettings406.bin
bin • 0.01 MB
printerSettings415.bin
bin • 0.01 MB
printerSettings416.bin
bin • 0.01 MB
printerSettings417.bin
bin • 0.01 MB
printerSettings424.bin
bin • 0.01 MB
printerSettings425.bin
bin • 0.01 MB
printerSettings426.bin
bin • 0.01 MB
printerSettings427.bin
bin • 0.01 MB
printerSettings428.bin
bin • 0.01 MB
printerSettings37.bin
bin • 0.01 MB
printerSettings423.bin
bin • 0.01 MB
printerSettings422.bin
bin • 0.01 MB
printerSettings418.bin
bin • 0.01 MB
printerSettings419.bin
bin • 0.01 MB
printerSettings420.bin
bin • 0.01 MB
printerSettings421.bin
bin • 0.01 MB
printerSettings402.bin
bin • 0.00 MB
printerSettings401.bin
bin • 0.00 MB
printerSettings400.bin
bin • 0.01 MB
printerSettings382.bin
bin • 0.01 MB
printerSettings383.bin
bin • 0.01 MB
printerSettings384.bin
bin • 0.01 MB
printerSettings385.bin
bin • 0.01 MB
printerSettings386.bin
bin • 0.01 MB
printerSettings381.bin
bin • 0.01 MB
printerSettings380.bin
bin • 0.01 MB
printerSettings379.bin
bin • 0.01 MB
printerSettings375.bin
bin • 0.01 MB
printerSettings376.bin
bin • 0.01 MB
printerSettings377.bin
bin • 0.01 MB
printerSettings378.bin
bin • 0.01 MB
printerSettings387.bin
bin • 0.01 MB
printerSettings38.bin
bin • 0.01 MB
printerSettings388.bin
bin • 0.01 MB
printerSettings396.bin
bin • 0.01 MB
printerSettings397.bin
bin • 0.01 MB
printerSettings398.bin
bin • 0.00 MB
printerSettings399.bin
bin • 0.01 MB
printerSettings395.bin
bin • 0.01 MB
printerSettings394.bin
bin • 0.01 MB
printerSettings393.bin
bin • 0.01 MB
printerSettings389.bin
bin • 0.01 MB
printerSettings390.bin
bin • 0.01 MB
printerSettings391.bin
bin • 0.01 MB
printerSettings392.bin
bin • 0.01 MB
printerSettings429.bin
bin • 0.01 MB
printerSettings430.bin
bin • 0.01 MB
printerSettings431.bin
bin • 0.01 MB
printerSettings467.bin
bin • 0.01 MB
printerSettings468.bin
bin • 0.01 MB
printerSettings469.bin
bin • 0.01 MB
printerSettings470.bin
bin • 0.01 MB
printerSettings471.bin
bin • 0.00 MB
printerSettings466.bin
bin • 0.01 MB
printerSettings465.bin
bin • 0.01 MB
printerSettings464.bin
bin • 0.01 MB
printerSettings36.bin
bin • 0.01 MB
printerSettings461.bin
bin • 0.01 MB
printerSettings462.bin
bin • 0.01 MB
printerSettings463.bin
bin • 0.01 MB
printerSettings472.bin
bin • 0.01 MB
printerSettings473.bin
bin • 0.00 MB
printerSettings474.bin
bin • 0.00 MB
printerSettings482.bin
bin • 0.01 MB
printerSettings483.bin
bin • 0.01 MB
printerSettings484.bin
bin • 0.01 MB
printerSettings485.bin
bin • 0.01 MB
printerSettings486.bin
bin • 0.01 MB
printerSettings481.bin
bin • 0.01 MB
printerSettings480.bin
bin • 0.01 MB
printerSettings479.bin
bin • 0.01 MB
printerSettings475.bin
bin • 0.00 MB
printerSettings476.bin
bin • 0.01 MB
printerSettings477.bin
bin • 0.01 MB
printerSettings478.bin
bin • 0.00 MB
printerSettings460.bin
bin • 0.01 MB
printerSettings459.bin
bin • 0.01 MB
printerSettings458.bin
bin • 0.01 MB
printerSettings439.bin
bin • 0.01 MB
printerSettings440.bin
bin • 0.01 MB
printerSettings441.bin
bin • 0.00 MB
printerSettings442.bin
bin • 0.01 MB
printerSettings443.bin
bin • 0.01 MB
printerSettings438.bin
bin • 0.00 MB
printerSettings437.bin
bin • 0.00 MB
printerSettings436.bin
bin • 0.00 MB
printerSettings432.bin
bin • 0.01 MB
printerSettings433.bin
bin • 0.01 MB
printerSettings434.bin
bin • 0.00 MB
printerSettings435.bin
bin • 0.01 MB
printerSettings444.bin
bin • 0.01 MB
printerSettings445.bin
bin • 0.01 MB
printerSettings446.bin
bin • 0.01 MB
printerSettings454.bin
bin • 0.01 MB
printerSettings455.bin
bin • 0.01 MB
printerSettings456.bin
bin • 0.01 MB
printerSettings457.bin
bin • 0.01 MB
printerSettings453.bin
bin • 0.01 MB
printerSettings452.bin
bin • 0.01 MB
printerSettings451.bin
bin • 0.01 MB
printerSettings447.bin
bin • 0.01 MB
printerSettings448.bin
bin • 0.01 MB
printerSettings449.bin
bin • 0.01 MB
printerSettings450.bin
bin • 0.01 MB
printerSettings374.bin
bin • 0.01 MB
printerSettings373.bin
bin • 0.01 MB
printerSettings372.bin
bin • 0.01 MB
printerSettings302.bin
bin • 0.01 MB
printerSettings303.bin
bin • 0.01 MB
printerSettings304.bin
bin • 0.01 MB
printerSettings305.bin
bin • 0.01 MB
printerSettings306.bin
bin • 0.01 MB
printerSettings301.bin
bin • 0.01 MB
printerSettings300.bin
bin • 0.01 MB
printerSettings299.bin
bin • 0.01 MB
printerSettings295.bin
bin • 0.00 MB
printerSettings296.bin
bin • 0.00 MB
printerSettings297.bin
bin • 0.01 MB
printerSettings298.bin
bin • 0.01 MB
printerSettings307.bin
bin • 0.01 MB
printerSettings308.bin
bin • 0.01 MB
printerSettings309.bin
bin • 0.01 MB
printerSettings314.bin
bin • 0.01 MB
printerSettings315.bin
bin • 0.01 MB
printerSettings316.bin
bin • 0.01 MB
printerSettings317.bin
bin • 0.01 MB
printerSettings318.bin
bin • 0.01 MB
ctrlProp19.xml
xml • 0.00 MB
printerSettings43.bin
bin • 0.01 MB
printerSettings44.bin
bin • 0.01 MB
printerSettings310.bin
bin • 0.01 MB
printerSettings311.bin
bin • 0.01 MB
printerSettings312.bin
bin • 0.01 MB
printerSettings313.bin
bin • 0.01 MB
printerSettings294.bin
bin • 0.00 MB
printerSettings293.bin
bin • 0.01 MB
printerSettings292.bin
bin • 0.01 MB
printerSettings274.bin
bin • 0.01 MB
printerSettings275.bin
bin • 0.01 MB
printerSettings276.bin
bin • 0.01 MB
printerSettings45.bin
bin • 0.01 MB
printerSettings277.bin
bin • 0.01 MB
printerSettings273.bin
bin • 0.01 MB
printerSettings272.bin
bin • 0.01 MB
printerSettings271.bin
bin • 0.01 MB
printerSettings267.bin
bin • 0.01 MB
printerSettings268.bin
bin • 0.01 MB
printerSettings269.bin
bin • 0.01 MB
printerSettings270.bin
bin • 0.01 MB
printerSettings278.bin
bin • 0.01 MB
printerSettings279.bin
bin • 0.01 MB
printerSettings280.bin
bin • 0.01 MB
printerSettings288.bin
bin • 0.01 MB
printerSettings289.bin
bin • 0.00 MB
printerSettings290.bin
bin • 0.00 MB
printerSettings291.bin
bin • 0.00 MB
printerSettings287.bin
bin • 0.00 MB
printerSettings286.bin
bin • 0.01 MB
printerSettings285.bin
bin • 0.01 MB
printerSettings281.bin
bin • 0.01 MB
printerSettings282.bin
bin • 0.01 MB
printerSettings283.bin
bin • 0.01 MB
printerSettings284.bin
bin • 0.01 MB
printerSettings319.bin
bin • 0.01 MB
printerSettings320.bin
bin • 0.01 MB
printerSettings321.bin
bin • 0.01 MB
printerSettings352.bin
bin • 0.01 MB
printerSettings353.bin
bin • 0.01 MB
printerSettings354.bin
bin • 0.01 MB
printerSettings355.bin
bin • 0.01 MB
printerSettings356.bin
bin • 0.01 MB
printerSettings351.bin
bin • 0.01 MB
ctrlProp21.xml
xml • 0.00 MB
printerSettings39.bin
bin • 0.01 MB
printerSettings348.bin
bin • 0.01 MB
printerSettings349.bin
bin • 0.01 MB
printerSettings350.bin
bin • 0.01 MB
printerSettings40.bin
bin • 0.01 MB
printerSettings357.bin
bin • 0.01 MB
printerSettings358.bin
bin • 0.01 MB
printerSettings359.bin
bin • 0.01 MB
printerSettings367.bin
bin • 0.01 MB
printerSettings368.bin
bin • 0.00 MB
printerSettings369.bin
bin • 0.00 MB
printerSettings370.bin
bin • 0.00 MB
printerSettings371.bin
bin • 0.01 MB
printerSettings366.bin
bin • 0.01 MB
printerSettings365.bin
bin • 0.00 MB
printerSettings364.bin
bin • 0.00 MB
printerSettings360.bin
bin • 0.01 MB
printerSettings361.bin
bin • 0.00 MB
printerSettings362.bin
bin • 0.01 MB
printerSettings363.bin
bin • 0.00 MB
printerSettings347.bin
bin • 0.01 MB
printerSettings346.bin
bin • 0.01 MB
printerSettings345.bin
bin • 0.01 MB
printerSettings329.bin
bin • 0.01 MB
printerSettings330.bin
bin • 0.01 MB
printerSettings331.bin
bin • 0.01 MB
printerSettings332.bin
bin • 0.01 MB
printerSettings333.bin
bin • 0.01 MB
printerSettings328.bin
bin • 0.01 MB
printerSettings327.bin
bin • 0.01 MB
printerSettings326.bin
bin • 0.01 MB
printerSettings322.bin
bin • 0.01 MB
printerSettings323.bin
bin • 0.01 MB
printerSettings324.bin
bin • 0.01 MB
printerSettings325.bin
bin • 0.01 MB
printerSettings334.bin
bin • 0.01 MB
printerSettings335.bin
bin • 0.01 MB
printerSettings42.bin
bin • 0.01 MB
printerSettings341.bin
bin • 0.01 MB
printerSettings342.bin
bin • 0.01 MB
printerSettings343.bin
bin • 0.01 MB
printerSettings344.bin
bin • 0.01 MB
printerSettings340.bin
bin • 0.01 MB
printerSettings339.bin
bin • 0.01 MB
printerSettings338.bin
bin • 0.01 MB
printerSettings41.bin
bin • 0.01 MB
ctrlProp20.xml
xml • 0.00 MB
printerSettings336.bin
bin • 0.01 MB
printerSettings337.bin
bin • 0.01 MB
printerSettings55.bin
bin • 0.01 MB
01_Attachment-3(QR).doc
doc • 0.10 MB
02_Attachment-8-Manufacturer Authorization Form.doc
doc • 0.04 MB
03_Attachment-18-SAFETY PACT.docx
docx • 0.03 MB
04_Attachment-20_KMP Declaration.doc
doc • 0.04 MB
05_Attachment-21-Affidavit of Self certification regarding Minimum Local Content.DOCX
docx • 0.02 MB
06_Attachment-22-Certificate by Auditor.docx
docx • 0.02 MB
07_Attachment-23-Compliance to the process related to the e-RA.docx
docx • 0.02 MB
08_Attachment-24_Declaration regarding events encountered pursuant to ITB Clause 2-1.docx
docx • 0.03 MB
09_Attachment-25-Authorization Certificate issued by Domestic Manufacturer.docx
docx • 0.02 MB
10_Attachment-26-Affidavit for Self Certifictaion-Iron & Steel.docx
docx • 0.02 MB
11_Attachment-27-Certification by the Bidder per DoE Order in line with ITB Clause 2-1.docx
docx • 0.02 MB
12_Attachment-28_Bid Securing Declaration.docx
docx • 0.02 MB
13_Legends for Units.pdf
pdf • 0.03 MB
00_Main Index_Volume-I.doc
doc • 0.03 MB
01-Section - I IFB SSTE.docx
docx • 0.04 MB
02 Section - II ITB SSTE S&I DCB-PRANIT.docx
docx • 0.10 MB
03 Section - III BDS SSTE.docx
docx • 0.06 MB
04-Annexure-A (BDS).doc
doc • 0.07 MB
04-Annexure-B(BDS).docx
docx • 0.02 MB
04-Annexure-C(BDS).docx
docx • 0.03 MB
05-Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
06-Section - V_SCC-AIS.doc
doc • 0.15 MB
07-Appendix -I to SCC.doc
doc • 0.16 MB
08-Sample Forms and Procedures.doc
doc • 0.53 MB
OBD_EXTN_LETTER_02.docx
docx • 0.15 MB
OBD_EXTN_LETTER.docx
docx • 0.16 MB
Price_schedule_Rev1.xlsx
xlsx • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .