Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC | L1 | Accepted-AOC Reasonable quote | |
| 2 | L2₹22.1 L+₹3.1 L (16.4%)Rejected-Finance | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹22.7 L+₹3.7 L (19.6%)Rejected-Finance | L3 | Rejected-Finance Not L1 Bidder | |
| 4 | L4₹25.4 L+₹6.4 L (33.7%)Rejected-Finance ROWRIAH KB ROAD PO CHALIHA JORHAT 785004 ASSAM | JORHAT | JORHAT | ASSAM | 785004 | L4 | Rejected-Finance Not L1 Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
25 Oct 2019, 6:00 pmClosed
GE JORHAT
GE JORHAT, POST-ROWRIAH, PIN 785 005 ASSAM
REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION WIRINGS INCLUDING FITTINGS FIXTURES AND REPAIRS TO FANS N GEYSERS IN CERTAIN BUILDINGS AT ROWRIAH SARAIBARI BHALUKMARA UNDER GE JORHAT
2019_MES_262250_4
8912/B/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JORHAT
as per NIT
7 documents required · 7 mandatory
₹500
Yes
GE JORHAT
₹40,000
Yes
30 Jul 2020
16 Oct 2019
26 Oct 2019
16 Oct 2019
25 Oct 2019
16 Oct 2019
Amount
Lump Sum price worked out by the bidder/tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule-A, Part-I
SCHEDULE-A , PART-II (MISCELLANEOUS ITEMS) Note:- This Schedule is not pre priced by MES and the pre priced rate indicated as Rs.0.00 under Column 5 signifies this fact only.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
Supply and Fix,LED batten with fire retardant poly carbonate housing and opal poly carbonate diffuser, with white LEDs,1X20 W, with electronic driver complete with all accessories internally pre wired,including lamp,complete all as specified and directed. [Cat No. "20W T5 60K LED Batten" Code 6BP2608F020 of Make 'Eveready' or equivalent Model of Make 'Philips'/ 'Bajaj']
All as per serial item No. 2.2 here in before but fixed in repairs.
Supply and Fix in repairs, decorative wall light fixture made up of polycarbonate, with and including 10 W retrofit LED Lamp (Spiral B-22 base) complete all as specified and directed. [Model CITY 2, Cat No. LHDL03160099 for light fitting and Cat No. LHLDEUEBML8Z010 for Lamp, of Make 'Havells' or equivalent Model of Make 'Philips'/ 'Eveready']
Supply and Fix in repairs, LED panel 12 Watts, recess mounted down lighter, square, with polycarbonate housing and polycarbonate diffuser, lumen efficacy up to 100lm/W, CRI :>80,intregrated driver, THD:<20%, integrated colour temperature:6500K, surge protection:2.5 KV, operating voltage:220-240 V AC, Ta:-10°C to 45°C, complete all as specified and directed. [Cat No. "LED Panel 12 W 65 K SQ Recess PC Backlit I " Code: 6PP16I8RB12 of Make 'Eveready' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and Fix in repairs, LED panel 22 Watts, recess mounted down lighter, square, with polycarbonate housing and polycarbonate diffuser,lumen efficacy up to 100lm/W, CRI :>80,intregrated driver, THD:<20%, integrated colour temperature:6500K, surge protection:2.5 KV, operating voltage:220-240 V AC, Ta:-10°C to 45°C, complete all as specified and directed. [Cat No. "LED Panel 22 W 65 K SQ Recess PC Backlit I " Code: 6PP16I8RB22 of Make 'Eveready' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and Fix in repairs, LED panel 12 Watts, recess mounted down lighter,round, with polycarbonate housing and polycarbonate diffuser,lumen efficacy up to 100lm/W, CRI :>80,intregrated driver, THD:<20%, integrated colour temperature:6500K, surge protection:2.5 KV, operating voltage:220-240 V AC, Ta:-10°C to 45°C, complete all as specified and directed. [Cat No. "LED Panel 12 W 65 K RD Recess PC Backlit I " Code:6PP26I8RB12 of Make 'Eveready' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and Fix in repairs, LED panel 15 Watts, recess mounted down lighter,round, with polycarbonate housing and polycarbonate diffuser,lumen efficacy up to 100lm/W, CRI :>80,intregrated driver, THD:<20%, integrated colour temperature:6500K, surge protection:2.5 KV, operating voltage:220-240 V AC, Ta:-10°C to 45°C, complete all as specified and directed. [Cat No. "LED Panel 15 W 65 K RD Recess PC Backlit I " Code:6PP26I8RB15 of Make 'Eveready' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and Fix,LED batten with fire retardant poly carbonate housing and opal polycarbonate diffuser with white LEDs,1X10 W, electronic driver complete with all accessories internally pre wired,including lamp,complete all as specified and directed. [Cat No. "10WT560K 2ft Batten" Code: 6BP2608T010 of Make 'Eveready' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and Fix in repairs, flexible LED strip, 24 Watts,color coordinated 5 Metres RGB strip with light travel function, LED Driver and IR remote complete all as specified and directed. [Model:Flexion LED Digital RGB strip IP40, Cat No. LHEHDNPNUN4F024 for LED Strip and Cat No. LSSLNW0135 for LED Driver, of Make 'Havells' or equivalent Model of Make 'Philips'/ 'Eveready']
Supply and Fix in repairs, 50W LED flood light luminaire in fire retardant polycarbonate (PC-FR) housing,electrical shock protection IEC 60598-1 Class 1,application voltage (Vac) 130~285, application ambient 10~45°C, performance frequency (Hz) 47 - 53, nominal test volt.& frequency (V/Hz) 220~240V / 50Hz,power factor 0.95, THD < 30%, supply current harmonics (IEC 61000-3-2) Nil, environmental condition (IEC60598-1 and EN62031) IP65,electrical & photometry :LFLI-PC-MP-50W,rated power 50W, nominal input power (W) 42+10%, input current (mA) 200+10%, nominal luminous flux (lm) 5000, efficacy (Lumen/Watt) 120, correlated colour temperature (K) 6500K, tolerance 6 SDCM, lumen maintenance - 6000 Hrs. 80%, colour rendering index > 80, beam angle (LM-79-08,Section 10) 120°, light source 1W MP LED,LED quantity 108(54S2P) 52(52S1P), rated life (L70F10) 15,000 hrs.,switching cycle (60 s on/180 s off) average - 30,000 cycles,over voltage withstanding 320Vac/48hrs, 340Vac/2hrs (no failure), transient / burst immunity (IEC 61000-4-4) > 3000 V, surge immunity (IEC 61000-4-5) > 2500 V, complete all as specified and directed. [Cat No. "LEDFL05016-01" Code:6F65PAC8050 of Make 'Eveready' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and Fix in repairs,LED security light fitting 20 Watt in pressure die cast aluminium housing, clear polycarbonate diffuser,IP 65, built in lens as secondary optic,integral constant current driver,operating voltage range 140V - 280 V AC, CCT 5700˚K ± 355K,CRI >70,operating temperature -10˚C to +50˚C,lumen efficacy 110 lm/watt,rated voltage 240V,frequency 50HZ, input wattage 20W±10%,max input current ≤ 0.089 A, including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.50 Sq mm, 3 core, 1100 Volts grade, from light fitting to point outlet, and including provision of fixing bracket made out of 25 mm bore galvanized steel tubing, medium grade, (0.60 RM Approx), bent to shape required and fixed to wall/pole with FI clamp 25 X 3 mm, nuts, bolts and washers, complete all as specified and directed. [Cat No. "LEDSLO20157-02" Code:6R57PAA7020 of Make 'Eveready' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs, fitted with Bus Bars, Neutral Links, Blanking Plates, MCCB, 4 pole, with current rating 160 Amps and 16 KA breaking capacity as incomer and MCB's as outgoing, 415 Volts, 12 Way, Triple Pole & Neutral, Vertical,fixed in repairs, complete all as specified and directed. [Cat No. 5077 48 (For enclosure) of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs, fitted with Bus Bars, Neutral Links, Blanking Plates, MCCB, 4 pole, with current rating 250 Amps and 25 KA breaking capacity as incomer and MCB's as outgoing, 415 Volts, 12 Way, Triple Pole & Neutral, Vertical,fixed in repairs, complete all as specified and directed. [Cat No. 5077 60 (For enclosure) of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and fix miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA, 6 to 32 Amps complete all as specified and directed. [Cat No. 4085 87/4085 90 /4085 92/4085 93 /4085 94 /4085 95 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and fix miniature circuit breaker (MCBs) single pole & neutral, 240 Volts, 10KA, 40 Amps complete all as specified and directed. [Cat No. 4086 18 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and fix miniature circuit breaker (MCBs) triple pole, & neutral, 415 Volts, 10KA, 63 Amps complete all as specified and directed. [Cat No. 4086 61 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, Moulded Case Circuit Breakers (MCCBs), AC 415V, 4 pole, with current rating 160 Amps and 16 KA breaking capacity, Ics=100%Icu, with thermal setting adjustable – 0.8 to 1In & magneticsetting fixed 10In, complete all as specified and directed. [Cat No. 4200 17 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, Moulded Case Circuit Breakers (MCCBs), AC 415V, 4 pole, with current rating 250 Amps and 25 KA breaking capacity, Ics=100%Icu, with thermal setting adjustable – 0.8 to 1In & magnetic setting adjustable 5 to10In, complete all as specified and directed. [Cat No. 4202 19 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix in repairs, Moulded Case Circuit Breakers (MCCBs), AC 415V, 4 pole, with current rating 63 Amps and 25 KA breaking capacity, Ics=100%Icu, with thermal setting adjustable – 0.8 to 1In & magneticsetting fixed 10In, complete all as specified and directed. [Cat No. 4200 53 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix in repairs, Moulded Case Circuit Breakers (MCCBs), AC 415V, 4 pole, with current rating 100 Amps and 25 KA breaking capacity, Ics=100%Icu, with thermal setting adjustable – 0.8 to 1In & magneticsetting fixed 10In, complete all as specified and directed. [Cat No. 4200 55 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix in repairs, Moulded Case Circuit Breakers (MCCBs), AC 415V, 4 pole, with current rating125 Amps and 25 KA breaking capacity, Ics=100%Icu, with thermal setting adjustable – 0.8 to 1In & magnetic setting fixed 10In, complete all as specified and directed. [Cat No. 4200 56 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Taking down carefully, existing defective storage type water heater (geyser) of any Capacity and Make for repairing, including replacement of defective spares as required and including replacement of terminals with defective connection wires and reinstallation of the geyser in original position including testing and commissioning, complete all as specified and directed.
Taking down carefully ceiling fan 1200 mm/1400 mm sweep,dismantaling of parts,cleaning internally and externally, lubrication of bearing / bushes using fresh lubricant as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed.
Taking down carefully ceiling fan 1200 mm sweep, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed.
Taking down carefully ceiling fan 1400 mm/1500 mm sweep, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed.
Taking down carefully exhaust fan 225 mm/300 mm / 450 mm size,dismantaling of parts,cleaning internally and externally, lubrication of bearing / bushes using fresh lubricant as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed.
Taking down carefully exhaust fan 225 mm size, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed.
Taking down carefully exhaust fan 300 mm/450 mm size, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed.
NOTES:- (Applicable for BOQ Serial Item No. 4.2 to 4.7 here in before) (i) Repairs and rewinding woks shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Cost of minor items like lubricants, insulating tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (iii) Spares required for replacement of defective ones will be measured and paid seperately under Prime Cost Sum (iv) The Contractor shall maintain service reports for all the appliances copy of the same will be submitted to the Engineer in Charge.
Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents. (a) Provide a prime cost of Rs 1,92,355.00 for supply only of spare parts suitable for various capacities/sizes/sweep of Storage Type Water Heater (Geyser)/ Ceiling Fans/ Exhaust Fans after dismantling and based on findings of the actual requirements of spares through a BOO convened by the Accepting Officer.The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE. (b) Bidder's/Contractor's quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidder's/Contractor's is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum insered by MES under Column 5. However,the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum insered by MES under Column 5. In case,the Bidder's/Contractor's quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum.
M/S FRONTIER CONSORTIUM
PEE BEE INDIA
M/S DHAR AND DHAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .