Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.3 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹32.1 L+₹2.8 L (9.64%)Rejected-Finance | 2 | Rejected-Finance NOT L1 | |
| 3 | 3₹32.6 L+₹3.3 L (11.2%)Rejected-Finance | 3 | Rejected-Finance NOT L1 | |
| 4 | 4₹33.2 L+₹4.0 L (13.5%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 4 | Rejected-Finance NOT L1 | |
| 5 | 5₹34.4 L+₹5.2 L (17.6%)Rejected-Finance | 5 | Rejected-Finance NOT L1 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
7 Oct 2021, 6:00 pmClosed
CWE LUCKNOW
229 MG ROAD CWE LUCKNOW
PROVN OF CONNECTING PATH TO STORS AND PROVN OF SHEDS AT FUR YARD EAST UNDER GE EAST LUCKNOW
2021_MES_474615_1
CWE/LKO/E/T-21 OF 2021-2022
Open Tender
Civil Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE EAST LUCKNOW
₹68,000
Yes
18 Oct 2021
11 Sept 2021
9 Oct 2021
11 Sept 2021
7 Oct 2021
25 Sept 2021
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cum, (0.55mx055mx1.5m deep) getting out, and removing soil to a distance n exc 50m complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L PCC 1:4:8 type D-2 usind 40 mm graded stone aggregate in foundations, filling/ sub base to floor and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graeded stone aggregate as in foundations, footings, complete all as specified and directed.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St.-240 complete all as specified and directed.
M&L for rolled mild steel work in Roof trusses framed), trussed, purlins, crane gantries,rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats and necessary welding as onforming Fe 410-W-(Gde-250) Quality-B complete all as specified and directed.
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed at the other end or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, diameter of shank 11 to 15 mm, lengt of bolt n exc 5cm long complete all as specified and directed.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graeded stone aggregate 40 mm thick in damp proof course to horizontal or vertical surfaces including necessary formwork uing WPC as per manufacture's instruction complete all as specified and directed. (Note: WPC shall be measured and paid separately)
M&L for 15 mm thick plastering in CM 1:4 on fair faces of brick or concrete surfaces, finished the surface even and smooth (without using extra cement) with using WPC @ 2% by weight of cement complete all as specified and directed. (Note: WPC shall be measured and paid separately)
Supply only Integral water proofing compound (ISI marked) complete all as specified and directed.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
All as per item No. 13 as above but appling two coats of cement base paint over a coat of primer on wall complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate for embedding of hold fast/ bed block complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in path and plinth protection surface finished even and smooth with using extra cement including forming construction (dumy) joints 12 mm wide & 65 mm deep and filled with mixture of bitumen and sand in the ratio of 1:3 laid at an interval of not exceeding 3m and change of direction complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S&F Expanded metal not exc 4 Kg per Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth, and aplying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick (size not less han 550mmx550mm) laid over and including cement screed bed 20 mm thick in CM 1:4 jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick on riser of steps, skirting, dado and pillar laid over cement screed 15 mm thick in CM 1:4 jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Returning fillingin including spreading, leveling, watering and well ramming in loayers n.exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for hardcore of broken stone aggregate gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L PCC tile coloured rubber moulded paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness M-40 Grade set, jointed and pointed with grey cement slurry and mixed with pigment to match the shade of the floor approved design / colour set and bedded over and including 25mm thick coarse sand complete all as specified and directed.
M&L for plastering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass, screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light/fan point controlled by one switch complete all as specified and directed.
All as item No 34 above but one 3 pin socket outlet, 05 Amps, independent with cable 1.5 Sqmm size complete all as specified and directed.
All as item No 34 above but one 3 pin socket outlet, 05 Amps point on the same board with other switches with cable 1.5 Sqmm size complete all as specified and directed.
All as item No 34 above but one 3 pin socket outlet, 15 Amps on independent but with cable 2.5 Sqmm complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 05 Amps complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 05 Amps complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 05 and 15 Amps fush type universal complete all as specified and directed.
S&F stepped type electornic fan regulator, flush and socket type on the existing phenolic laminated sheet humfree 2 module ISI marked complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F in replacement of integrated LED bulk head fitting 10 watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing polycarbonate cover etc complete all as specified and directed.
S&F in replacement of single side connection LED T8 tube light rod 20 watt 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed.
S&F in replacement of LED security light fitting 45 watt, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electornic driver etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 32mm bore light grade G.I tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in `L' shape and fixed to wall by means of 02 Nos of 40 x 5mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
S&F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and directed.
S&F in replacement of sheet metal enclosure distribution board, single pole and neutral, AC 240 volt, 08 way with 200 Amp rated copper bus bar and metal door with IP-43 & IK 09 protection alongwith cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F in replacment of MCB, SP, AC 240 volt of 06 of 32 Amp capacity `C' curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F in replacement of MCB, DP, AC 240 volt of 32 Amp capacity `C' curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
M&L for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25mm dia, medium grade complete with and including all PVC conduit accesories concealed into wall by cutting of chases in wall complete all as specified and directed.
Supply laying testing and commissioning LT underground XLPE insulated, armoured heavy duty electric cable with aluminium stranded conductor, 1100 volt grade conforming to IS-1554 and ISI marked of cross sectional area 10 Sqmm 2 core size in trenches on wall road crossing through protection pipe etc complete all as specified and directed.
M&L sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed. Note: Punned thickness shall be measured for payment.
Supply and laying 50mm bore galvanised steel tubes with all fittings, light grade laid in trenches for cable protection complete all as specified and directed.
Supply and laying common burned clay bricks sub class B designation of old size bricks complete all as specified and directed.
S&F exhaust fans single phase 230/240 volts heavy duty metalic body of size 300mm sweep 1400 RPM ISI marked and making connection with twisted copper flexibel wire 23/0.076 mm all as specified and directed. Make/Model-Havells Turbo force SP/Almonard 300mm heavy duty/Usha turbo heavy duty.
S&F louvers for 300mm sweep exhaust fan circular in shape of min 18mm guage GI sheet fixed outside of the wall all as specified and directed.
S&F ceiling fan of 1200mm sweep, 230V, 350/370 RPM with air delivery of 215 cum/minute or more with BEE STAR RATED including provn of fan hook made of MS of required size and shape hanging with the help of down rod upto 04 feet and connecting with provn of 3 core copper cable of size 1.5 Sqmm from ceiling rose to fan complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in electrical plate NO 3 of SSR Part-I 2009 and connected to main switch board/Main DB's including excavation, earth work,salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wiremesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit/chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
M/S RAJ INTERIORS
Spectrum Enterprises
QUALITY CONSTRUCTIONS CO
SENGAR CONSTRUCTIONS
Allied Builders And Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .