Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance P 41 IIND FLOOR PANDAV NAGAR MAYUR VIHAR PH I DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹24.8 L
EMD Value
₹48,625
Closing Date
18 Feb 2020, 11:30 amClosed
Chief Engineer
ESD 6 th Floor CSIR Complex, Pusa, New Delhi
AGM contract of Window, Split, Ductable, Package type AC units, water coolers, fridges, deep freezers and water dispensers installed at CSIR Hq, CSIR Vigyan Kendra, CSIR Comple, CSIR MBSA and CSIR Naraina, New Delhi
2020_CSIR_42521_1
11-6(1)/2019-Engg
Open Tender
Electrical Works
Item Rate
365 days
ESD CSIR Complex Pusa New Delhi
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
US
₹48,625
24 Feb 2020
10 Feb 2020
19 Feb 2020
10 Feb 2020
18 Feb 2020
10 Feb 2020
Amount
Sub-Head:I Annual Maintenance Including Attending Day to Day Complaints of window, split, ductable, package type AC units, water coolers, fridges, deep freezers and water dispensers installed at CSIR Hq. & CSIR Vigyan Kendra, CSIR MBSA, CSIR Complex and CSIR Narina, New Delhi.
Operation and Annual Maintenance including attending Day to Day Complaints of window, split, ductable, package type AC units, water coolers, fridges, deep freezers and water dispensers installed at CSIR Hq. & CSIR Vigyan Kendra, CSIR MBSA, CSIR Complex and CSIR Naraina New Delhi. Scope of work and deployment of man-power as per attached Annexure-I.
Sub-Head: II Repair & replacement of materials
Annual maintenance contract of following window and split type air conditioning units including voltage stebilizers wherever installed, complete in all respect.
Window type air conditioners upto 2 TR capacity (All Makes)
Replacement of Compressor
Repairing of Blower Motor
Replacement of Blower
Replacement of Thermostat
Replacement of Over Load Relay
Replacement of Running capacitor
Replacement of Starting capacitor
Replacement of Fan Motor Capacitor
Gas charging (vaccumisation, pressure testing, brazing) etc. in case of leakage
Servicing, cleaning, washing, greasing, oiling etc.
Replacement of filter
Installation / Relocation of existing window type air conditioning units, including removing of glass panel and providing wooden frame, etc. for the A/C unit.
Display switch and PCB
Replacement of front grill
Replacement of Outdoor Unit fan
Split type air conditioners upto 2.5 TR capacity, High wall/Floor mounted (All Makes)
Replacement of Compressor
Repairing of Blower Motor
Replacement of Indoor Unit Filter
Replacement of Thermostat
Over load protector
Replacement of Running capacitor
Replacement of Starting capacitor
Replacement of Fan motor capacitor
Replacement of Indoor Unit Motor
Repairing / replacement of Swing motor
Servicing, cleaning, washing, greasing, oiling etc.
Display switch and PCB
Insulation of piping
Replacement of Indoor Unit Blower
Replacement of Outdoor Unit Motor
Gas changing (vacuumisation, pressure testing, brazing etc. in case of leakage
Installation/Relocation of existing split type air conditioning units, including removing of glass panel and providing wooden frame, etc. for the A/C unit .
Replacement of connector 15 A
Replacement of single phase contactor upto 32 Amp
Replacement of Outdoor Unit fan
Split inverter type air conditioners upto 2.0 TR capacity High wall mounted (All make)
Replacement of Compressor
Repairing of Blower Motor
Replacement of Indoor Unit Filter
Replacement of thermostat
Replacement of Over load protector
Replacement of Running capacitor
Replacement of Starting capacitor
Replacement of Fan motor capacitor
Replacement of Indoor Unit Motor
Replacement of Swing motor
Servicing, cleaning, washing, greasing, oiling etc.
Display switch and PCB
Insulation of piping
Replacement of Indoor Unit Blower
Replacement of Outdoor Unit fan
Gas changing (vacuumisation, pressure testing, brazing etc. in case of leakage
Variable Frequency drive
Replacement of connector 15 A
Replacement of single phase contactor upto 32 Amp
Cassette type air conditioners upto 4.0 TR capacity ceiling mounted/ floor mounted (All Makes)
Replacement of Compressor
Repairing of Blower Motor
Replacement of Indoor filter
Replacement of thermostat
Replacement of Over load protector
Replacement of Running capacitor
Replacement of Starting capacitor
Replacement of Fan motor capacitor
Replacement of Indoor Unit Motor
Replacement of Swing motor
Servicing, cleaning, washing, greasing, oiling etc.
Display switch and PCB
Insulation of piping
Replacement of Indoor Unit Blower
Replacement of Outdoor Unit fan
Gas changing (vacuumisation, pressure testing, brazing etc. in case of leakage
Drainage pump
Replacement of connector 15 A
Replacement of single phase contactor upto 32 Amp
Tower Type Split air conditioners 3.0 TR capacity floor mounted (all make)
Replacement of Compressor
Repairing of Blower Motor
Replacement of Indoor Unit Filter
Replacement of thermostat
Replacement of Over load protector
Replacement of Running capacitor
Replacement of Starting capacitor
Replacement of Fan motor capacitor
Replacement of Indoor Unit Motor
Replacement of Swing motor
Servicing, cleaning, washing, greasing, oiling etc.
Display switch and PCB
Insulation of piping
Replacement of Indoor Unit Blower
Replacement of Outdoor Unit Fan
Gas changing (vacuumisation, pressure testing, brazing etc. in case of leakage
Replacement of connector 15 A
Replacement of single phase contactor upto 32 Amp
Ductable type air conditioners upto 7.5 TR capacity floor mounted (All make)
Replacement of Outdoor Unit Motor
Replacement of Indoor Unit Blower
Replacement of 3 Phase Contactor
Replacement of Over load protector
Replacement of Fan motor capacitor
Servicing, cleaning, washing, greasing, oiling etc.
Display switch and PCB
Insulation/ clamping/ support etc. of copper tubing
Replacement of Indoor Unit Blower Motor
Replacement of Outdoor Unit Fan
Gas / Refrigant changing (vacuumisation, pressure testing, brazing etc. in case of leakage
Replacement of connector 15 A
Replacement of single phase contactor upto 32 Amp
Replacement of Compressor
Replacement of V-Belt for blower
Ductable type air conditioners upto 16.5 TR capacity floor mounted (All make)
Repairing/ Replacement of Outdoor Unit Motor
Replacement of Indoor Unit Blower
Replacement of 3 phase Contactor
Replacement of Over load protector
Replacement of Fan motor capacitor
Servicing, cleaning, washing, greasing, oiling etc.
Display switch and PCB
Insulation/ clamping/ support etc. of copper tubing
Replacement of Indoor Unit Blower Motor
Replacement of Outdoor Unit Fan
Gas / Refrigerant changing (vacuumisation, pressure testing, brazing etc. in case of leakage
Replacement of connector
Replacement of single phase contactor upto 32 Amp
Replacement of Compressor 5.5 TR
Replacement of V-Belt for blower
Maintenance contract of package type air-conditioning units of 11 TR capacity complete with all accessories and electrical control panel including supply of all consumables as per the scope of work for effective operation of the air-conditioning units installed of different make and capacities.
Replacement of Outdoor Unit Motor
Replacement of Indoor Unit Blower
Replacement of 3 phase Contactor
Replacement of Over load protector
Replacement of Fan motor capacitor
Servicing, cleaning, washing, greasing, oiling etc.
Display switch and PCB
Insulation / clamping / support etc. of copper tubing
Replacement of Indoor Unit Blower Motor
Replacement of Outdoor Unit Fan
Gas / Refrigant changing (vacuumisation, pressure testing, brazing etc. in case of leakage
Replacement of connector 15 A
Replacement of single phase contactor upto 32 Amp
Replacement of Compressor 5.5 TR
Replacement of V-Belt for blower
Annual maintenance contract of storage type water coolers 150 Ltrs. capacity including voltage stabilizers wherever installed of different make.
Replacement of Compressor
Repairing of fan motor
Gas changing(vaccumisation, pressure testing, brazing etc. in case leakage
Replacement of Fan Capacitor
3 Pin Top 16A
Reaparing/Replacement of thermostat, capillary tube etc.
Servicing, cleaning, washing, greasing. Oiling Once a year
Replacement / repairing of condensor Coil
Float valve / water tap, fittings etc.
Replacement of Running capacitor
Replacement of Relay
Annual maintenance contract of following capacities fridges including voltage stabilizers wherever installed of different make and capacities: (a) Fridge upto 90 ltrs. Capacity ( All Makes)
Replacement/repairing of compressor
Gas changing (vaccumisation, pressure testing, brazing etc. in case of leakage
Thermostat
Door switch
Relay
Capacitor
L/L Filter
Servicing, cleaning, washing, greasing, oiline Once a year
Evaporator
Condenser
Fridge above 90 ltrs. To 280 ltrs Capacity (All Makes)
Replacement/repairing of compressor
Gas changing (vaccumisation, pressure testing, brazing etc. in case of leakage
Thermostat
Door switch
Relay
Capacitor
L/L Filter
Servicing, cleaning, washing, greasing, oiline Once a year
Evaporator coil
Condenser coil
Fridge above 280 ltrs. To 550 ltrs Capacity ( All Makes)
Replacement/repairing of compressor
Gas changing (vaccumisation, pressure testing, brazing etc. in case of leakage
Thermostat
Door switch
Relay
Capacitor
L/L Filter
Servicing, cleaning, washing, greasing, oiline Once a year
Evaporator coil
Condenser coil
Annual maintenance contract of deep freezers upto 1300 Ltrs including voltage stabilizers wherever installed of different make and capacities.
Replacement/repairing of compressor
Gas changing (vaccumisation, pressure testing, brazing etc. in case of leakage
Thermostat
Door switch
Relay
Motor Capacitor
L/L Filter
Servicing, cleaning, washing, greasing, oiline Once a year
Evaporator coil
Condenser coil
Starting Capacitor
Running Capacitor
Replacement of Outdoor Unit fan
Annual maintenance contract of water dispenser (Hot & Cold) wherever installed of different make and capacities.
Repair/ Replacement of Dispenser Drain Tray
Repair/ Replacement of Hot/ Cold water dispenser tank
Repair/ Repacement of Dispenser Handle Tap
Repair/ Repacement of tap connectors
Repair/ Repacement of Dispenser Power cords
Repair/ Repacement of Dispenser thermostat
Repair/ Repacement of Dispenser valve
Repacement of Compressor
Repacement of Heating element
Supplying, Fabrication and fixing of suitable size MS angles frame for split AC unit duly painted for the above mentioned outdoor units etc complete as required.
Supply of following size copper conductor, PVC Insulated & PVC round sheathed multicore bright annealed bare copper conductor flexible cable for voltage grade upto 1100 V as per IS:694/1990 including connections etc complete as required.
3 C x 2.5 Sq.mm
3 C x 4.0 Sq.mm
Supply and fixing of following size PVC hard drain pipe for above said split AC units etc. complete as required
25 mm diameter
32 mm diameter
Supplying and fixing of suitable size PVC Channel for above said split AC units etc. complete as required.
Supplying and fixing of suitable size additional copper refrigerent pipe up to 2.0 TR AC unit with proper insularion along with control wiring, power cable for interconnection of outdoor unit and indoor unit and drain pipe with insulation, accessories etc complete as required.
Sub-Head: III Salvage Value
Salvage value of dismentled old all make / model window type air-conditioner upto 2 TR "As is where is basis"
Salvage value of dismentled old all make / model Split air-conditioner upto 2 TR "As is where is basis"
Meena and Sons Airconditioning Co
UNIQUE AIRCONDITIONING
supercool
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .