Ranjeet Kumar, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPL REPAIRS/REPLACEMENT OF LT NETWORK IN DSC OTM BLDG, DSC MD ACCN, NC(E) AND 84 MD ACCN AREA IN DOMESTIC AREA OF AFS YELAHANKA
2026_MES_791105_1
86253/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Yelahanka
As per Tender Document
8 documents required · 8 mandatory
₹1,000
₹1.3 L
Yes
25 Sept 2026
25 Sept 2026
30 Oct 2026
25 Sept 2026
22 Oct 2026
16 Oct 2026
25 Sept 2026 - 1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Fabricate, supply ,install testing and commissioning of LT panel Outdoor type in replacement 415 Volts, 50 Hz, 3 phase, 4 wire for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for outdoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 300 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER :-
(a) 4 Pole MCCB 200 Amp, (with thermal magnetic release) 50 Hz, 415 V with rupturing capacity 25 KA, -1 No
OUTGOING
(b) 4 Pole MCCB 125 Amp, (with thermal magnetic release),50 Hz, 415 V with rupturing capacity 25 KA, -01 No
(d) 4 Pole MCCB 63 Amp, (with thermal magnetic release), 50 Hz, 415 V with rupturing capacity 16 KA, -02 No
(e) 4 Pole MCCB 40 AMps , (with thermal magnetic release), 50 Hz , 415V with rupturing capacity 16 KA -02 Nos
(e) Multifunctional VAF Meter -01 No
(f) Digital Ammeter-01 N
(g) CT's 200/5- set of 3 No
(h) LED type Indication lamps (RYB)-one set(For each incoming and outgoing)
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iii) Bottom portion of panel should be 45 CM above from the ground level. | 1 | EACH JOB | 16 | ₹16 |
| 2 | Fabricate, supply ,install testing and commissioning of LT panel outdoor type in replacement 415 Volts, 50 Hz, 3 phase, 4 wire for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 300 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER
(a) Onload change over switch 4 Pole 200 Amps (Incomer )-01 nos
OUTGOING
( b) 4 Pole MCCB 125 Amp (With thermal and magnetic settings) , 50 Hz, 415 V with rupturing capacity 25 KA,-01 No
(c) 4 Pole MCCB 63 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA, -04 No
(d) Digital Multifunctional VAF Meter -01Nos
(e) CT's 200/5- set of 3
(g) LED type Indication lamps (RYB)-one set of 03 (for each incoming and outgoing)
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iiI) Bottom portion of panel should be 45 CM above from the ground level. | 1 | EACH JOB | 16 | ₹16 |
| 3 | Fabricate, supply ,install testing and commissioning of LT panel outdoor type inreplacement, 415 Volts, 50 Hz, 3 phase, 4 wire Suitable for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for outdoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 300 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER
(a) On load changeover switch 200 Amps , Incomer -1 No
OUTGOING
(b) 4 Pole MCCB 160 Amp, with thermal and magnetic release, 50 Hz, 415 V with rupturing capacity 25 KA,-01 No
(c) 4 Pole MCCB 63Amp, with thermal and magnetic release ,50 Hz, 415V with rupturing capacity 25 KA- 41 No
(d) TPN MCB 32 Amp,50 Hz, 415V with rupturing capacity 10 KA- 01 No
(d) Multifunctional VAF meter -01 Nos
(f) CT's 200/5- set of 3 No
(g) LED type Indication lamps (RYB)-one set(for each incoming and outgoing)
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iiI) Bottom portion of panel should be 45 CM above from the ground level. | 1 | EACH JOB | 16 | ₹16 |
| 4 | Fabricate, supply ,install testing and commissioning of LT panel Outdoor type in replacement 415 Volts, 50 Hz, 3 phase, 4 wire for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for outdoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 300 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER :-
(a) 4 Pole MCCB 200 Amp, (with thermal magnetic release) 50 Hz, 415 V with rupturing capacity 25 KA, -1 No
OUTGOING
(b) 4 Pole MCCB 125 Amp, (with thermal magnetic release),50 Hz, 415 V with rupturing capacity 25 KA, -01 No
(d) 4 Pole MCCB 63 Amp, (with thermal magnetic release), 50 Hz, 415 V with rupturing capacity 16 KA, -02 No
(e) 4 Pole MCCB 40 AMps , (with thermal magnetic release), 50 Hz , 415V with rupturing capacity 16 KA -02 Nos
(e) Multifunctional VAF Meter -01 No
(f) Digital Ammeter-01 No
(g) CT's 200/5- set of 3 No
(h) LED type Indication lamps (RYB)-one set (For each incoming and outgoing )
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iiI) Bottom portion of panel should be 45 CM above from the ground level. | 1 | EACH JOB | 16 | ₹16 |
| 5 | Fabricate, supply ,install testing and commissioning of LT panel outdoor type in replacement 415 Volts, 50 Hz, 3 phase, 4 wire for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 300 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER
(a) Onload change over switch 4 Pole 200 Amps (Incomer )-01 nos
OUTGOING
( b) 4 Pole MCCB 125 Amp (With thermal and magnetic settings) , 50 Hz, 415 V with rupturing capacity 25 KA,-01 No
(c) 4 Pole MCCB 63 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA, -04 No
(d) Digital Multifunctional VAF Meter -01Nos
(e) CT's 200/5- set of 3
(g) LED type Indication lamps (RYB)-one set of 03 (for each incoming and outgoing)
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iiI) Bottom portion of panel should be 45 CM above from the ground level. | 2 | EACH JOB | 16 | ₹32 |
| 6 | Fabricate, supply ,install testing and commissioning of LT panel outdoor type in replacement 415 Volts, 50 Hz, 3 phase, 4 wire for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for outdoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 200 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER
(a) 4 Pole MCCB 125 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA, Incomer -1 No
OUTGOING
(b) 4 Pole MCCB 40 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 16 KA-06 Nos
(c) Digital Multifunctional VAF Meter -01 nos
(d) CT's 200/5- set of 3 No
(e) LED type Indication lamps (RYB)-one set (for each incoming and outgoing)
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iiI) Bottom portion of panel should be 45 CM above from the ground level. | 1 | Each Job | 16 | ₹16 |
| 7 | Fabricate, supply ,install testing and commissioning of LT panel Outdoor type in replacement ,415 Volts, 50 Hz, 3 phase, 4 wire suitable for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for outdoor door use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 400 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER
(a) Onlaod changeover switch 315 Amps 4 Pole -1 No
OUTGOING
(b) 4 Pole MCCB 200 Amp (With thermal and magnetic settings), 50 Hz, 415 V with rupturing capacity 25 KA-01Nos
(c) 4 Pole MCCB 125 Amp(With thermal and magnetic settings), 50 Hz, 415 V with rupturing capacity 25 KA-01 Nos
(d) MCCB 4 Pole 63 Amps(With thermal and magnetic settings), 50 Hz 415V with rupturing capacity 16 KA -01 Nos
(d) Digita VAF Ammeter-01 No
(f) CT's 315/5- set of 3 No
(e) LED type Indication lamps (RYB)-one set
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iiI) Bottom portion of panel should be 45 CM above from the ground level. | 1 | Each Job | 16 | ₹16 |
| 8 | Fabricate, supply ,install testing and commissioning of LT panel Outdoor type in replacement, 415 Volts, 50 Hz, 3 phase, 4 wire suitable for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for outdoor door use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 400 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER
(a) 4 Pole MCCB 320 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 36 KA, Incomer -1 No
OUTGOING
(b) 4 Pole MCCB 200 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA-01Nos
(c) 4 Pole MCCB 125 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA-01 Nos
(d) 4 Pole MCCB 63 AMps(With thermal and magnetic settings) MCCB 25 KA -01 Nos
(e) MCB SPN 40 Amps 10 KA -01 Nos
(f) Digital VAF Meter -01 nos
(g) CT's 400/5- set of 3 No
(h) LED type Indication lamps (RYB)-one set
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iiI) Bottom portion of panel should be 45 CM above from the ground level. | 1 | EACH JOB | 16 | ₹16 |
| 9 | Fabricate, supply ,install testing and commissioning of LT panel Outdoor type in replacement 415 Volts, 50 Hz, 3 phase, 4 wire suitable for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for outdoor door use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 300 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER
(a) 4 Pole MCCB 200 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA, Incomer -1 No
OUTGOING
(b) 4 Pole MCCB 125 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA-02Nos
(c) 4 Pole MCCB 100 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA-01 Nos
(d) MCCB 4P 63 Amps (With thermal and magnetic settings) 25 KA -01 Nos
(e) MCB SPN 40 AMps -02 Nos
(f) Digital VAF Meter -01 No
gf) CT's 300/5- set of 3 No
(h) LED type Indication lamps (RYB)-one set
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iiI) Bottom portion of panel should be 45 CM above from the ground level. | 1 | EACH JOB | 16 | ₹16 |
| 10 | Fabricate, supply ,install testing and commissioning of LT panel Outdoor type in replacement 415 Volts, 50 Hz, 3 phase, 4 wire suitable for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for outdoor door use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 400 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed:-
INCOMER
(a) Onload changeover switch 4 Pole 200 Amps -01 Nos
OUTGOING
(b) 4 Pole MCCB 160 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA-01Nos
(c) 4 Pole MCCB 125 Amp,(With thermal and magnetic settings) 50 Hz, 415 V with rupturing capacity 25 KA-01 Nos
(d) 4 Pole MCCB 63 Amps (With thermal and magnetic settings) 4 Pole 16KA -03 Nos
(e) Digital VAF Meter -01 No
(f) CT's 300/5- set of 3 No
(e) LED type Indication lamps (RYB)-one set
Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work.
(ii) Switich gear and connected items should be of approved make.
(iiI) Bottom portion of panel should be 45 CM above from the ground level. | 1 | EACH JOB | 16 | ₹16 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
86253Tender.pdf
Tender Documents • 2.46 MB
BOQ_886907.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .