Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC | ₹5.8 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹6.2 Cr+₹37.8 L (6.47%)Rejected-Finance | ₹6.2 Cr+₹37.8 L (6.47%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹6.2 Cr+₹37.8 L (6.47%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹6.2 Cr+₹37.8 L (6.47%) | L3 | Rejected-Finance Not being L1 |
Tender Value
₹5.3 Cr
EMD Value
₹5.9 L
Closing Date
20 May 2024, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
801586PROVISION OF TRAINING SHEDS OBSTACLE TRAINING INFRASTRUCTURE AND TOILETS LADIES AND GENTS AT CERTAIN LOCATIONS AT ATS BELAGAVI
2024_MES_642398_1
801586/AF/E8
Open Tender
Civil Works
Lump-sum
540 days
GE (AF) SAMBRA
A CLASS cat a i
8 documents required · 8 mandatory
₹3,000
GE (AF) SAMBRA
₹5.9 L
Yes
31 May 2024
14 Feb 2024
27 May 2024
14 Feb 2024
20 May 2024
6 May 2024
15 Feb 2024 - 25 Feb 2024
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to IX are prepriced by MES under Ser Nos. 2.00 to 10.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Building or works” as listed in Schedule ‘A’ Part - I inserted by MES.
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part - II inserted by MES .
Lumpsum price worked out by the contractor for “Internal Electric Supply” as listed in Schedule ‘A’ Part - III inserted by MES .
Lumpsum price worked out by the contractor for “Site Clearance and Land development including demolition of PCC hard standing” as listed in Schedule ‘A’ Part - IV inserted by MES .
Lumpsum price worked out by the contractor for “Path” as listed in Schedule ‘A’ Part - V inserted by MES .
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part - VI inserted by MES .
Lumpsum price worked out by the contractor for “Obstacles” as listed in Schedule ‘A’ Part -VII inserted by MES .
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part -VIII inserted by MES .
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part -IX inserted by MES .
Schedule ‘A’ Parts X and XI are not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
Schedule 'A' Part - X : Design, Supply and erection of Pre-Engineered building steel structure for Training shed of size 30m x 14m and 3.2m height (inner dimension) with trapezoidal profile pre-painted Galvalume sheet 0.50mm thick, RCC M-25 Design mix foundation, anchor bolt in the base and bed plates, PCC floor and underlayers, solid block masonry in side walls upto 1m height, plastering in cement mortar, plinth protection, Epoxy coated paints to structural steel surface. etc complete all as specified and as shown on drawings. Note: (i) PCC floor and underlayers as specified in schedule of finishes are deemed to be included in the quoted Lumpsum.
Design, Supply and erection of Pre-Engineered building steel structure for Training shed of size 30m x 12m and 3.2m height (inner dimension) with trapezoidal profile pre-painted Galvalume sheet 0.50mm thick, RCC M-25 Design mix foundation, anchor bolt in the base and bed plates, PCC floor and underlayers, solid block masonry in side walls upto 1m height, plastering in cement mortar, plinth protection, Epoxy coated paints to structural steel surface. etc complete all as specified and as shown on drawings. Note: (i) PCC floor and underlayers as specified in schedule of finishes are deemed to be included in the quoted Lumpsum.
Design, Supply and erection of Pre-Engineered building steel structure for Training shed of size 30m x 10m and 3.2m height (inner dimension) with trapezoidal profile pre-painted Galvalume sheet 0.50mm thick, RCC M-25 Design mix foundation, anchor bolt in the base and bed plates, PCC floor and underlayers, solid block masonry in side walls upto 1m height, plastering in cement mortar, plinth protection, Epoxy coated paints to structural steel surface. etc complete all as specified and as shown on drawings. Note: (i) PCC floor and underlayers as specified in schedule of finishes are deemed to be included in the quoted Lumpsum.
Design, Supply and erection of Pre-Engineered building steel structure for Training shed of size 25m x 12m and 3.2m height (inner dimension) with trapezoidal profile pre-painted Galvalume sheet 0.50mm thick, RCC M-25 Design mix foundation, anchor bolt in the base and bed plates, PCC floor and underlayers, solid block masonry in side walls upto 1m height, plastering in cement mortar, plinth protection, Epoxy coated paints to structural steel surface. etc complete all as specified and as shown on drawings. Note: (i) PCC floor and underlayers as specified in schedule of finishes are deemed to be included in the quoted Lumpsum.
Schedule 'A' Part - XI : Fittings, Fixtures & Misc items: INTERNAL WATER SUPPLY Supply and fix 15mm dia 2way bib tap with aerator or flow regulator cast copper alloy with crutch or butterfly handle, screwed down, screwed for CPCV pipeor for brass ferrule with connected accessories with wall flange complete all as specified and as directed.
Supply and fix stainless steel soap dish fixed to wall complete all as specified and as directed.
Supply and fix 25mm bore ball/gate valve of CPVC material fixed to CPVC pipe using chemical connected with unions complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY Supply and fix LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Make - Bajaj Cat Pat No - BCLAB 20W LED P or equivalent in approved make listed in PS
Supply and fix LED 70/80 watt Floodlight luminaire with pressure die cast housing and toughened glass and individual LED's with secondary lens optics with IP66 ingress protection, 4 kV inbuilt and 10 kV external surge protection, Efficacy 120 lm/W complete all as specified and as directed. Make - Bajaj Cat Pat No - PRAZE F 96L WH NB-A5 TG SD or equivalent in approved make listed in PS
Supply and fix LED flood light 50 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. Make - Bajaj Cat Pat No - BJFL50WLEDI or equivalent in approved make listed in PS
Supply and fix LED light fitting 1 x 20W, 220V, 2000 lumnes, luminuous efficacy 100 lumen / watt, AC decorative box type with driver, holder including retrofit LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fix LED light fittings 1 x 10W, 220V, lumen efficacy110 lumen/ watt, total lumen 1100, 6500 K, cool day light, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fix exhaust fan / ventilation fan of 300 mm sweep made up of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, copper winding including writing MES No., 2cm height with synthetic enamel black colour paint complete all as specified and as directed.
Supply and fix 35/36watts LED security light fitting with pressure die cast IP 65 protection, luminous efficiency of 100 lumen/watt, PF > 0.95, CRI > 50, colour temperature 5700 K suitable for primary roads with all connected accessories including bracket made up of GI tubing of 25mm outer dia, 1.2m length, light grade with GI clamps, nuts and bolts etc for fixing of fitting complete all as specified and as directed.
SEWAGE DISPOSAL Supply and fix 25 user LLDPE septic tank designed to carry sewage and sullage water including excavation in any type of soil, PCC (1:4:8) below foundation, Vent shaft, connection etc., complete all as shown on drawings and as specified and directed.
Construction of Soakage wells 2.40m dia X 3.00m Effective depth size and excavation, in any type of soil, foundation in PCC (1:3:6), walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size complete all as specified and shown on drawings.
EXTERNAL ELECTRIC SUPPLY Supply and fix LED street light fitting 110 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. Note :- Cost of Fabrication of GI Arm for fixing of Street Light fitting is included in rate quoted by the contractor Make - Bajaj Cat Pat No - ZELA P 132L WH PO TG SD or equivalent in approved make listed in PS.
Supply and fix Junction Box / loop in loop out box Maintenance free IP 65 weather proof of size 300x200x105 mm fixed to pole / wall with suitable FI clamp 20X3 mm nuts, bolts and washers including provision of 01 No miniature circuit breaker (MCBs) SPN, 240 volts 10 KA 06-32 Amps and including suitable for 1 Nos 10/6 sqmm x 4/2 core XLPE incoming and 1 Nos 10/6 sqmm x 4/2 core XLPE outgoing cable, also provision of single phase 02 nos aluminium bus bar with suitable lux complete all as specified and as directed.
Material and labour for including T&P for boring of holes under road, pavement, hardstanding by using trenchless technology (ultra sound technique) and necessary machine upto and including 150mm dia HDPE pipe and connected items suitable for 0.4mpa working pressure, trench depth from natural GL not exceeding 600mm complete all as specified and as directed.
Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed. Make - Legrand Cat Pat No AlphaRex D22 Astro, 02 Channel or equivalent in approved make listed in PS.
Supply and fix DWC Pipe IS-16205, size inner dia 32 mm, outer dia 40 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed.
Supply and fix FR 4 Sqmm 3 core PVC round cable 1100volts conforming for IS 694 suitable for high mast 9 mtr pole for laying from junction box to high mast lights complete all as specified and as directed.
Returning and filling of trenches in two parts (i) using riddled soil obtained from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note :- (i) Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning.
KARNI BUILDERS
Phoenix Infra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .