The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Important Note :- For Detail Regarding Financial Eligibility Criteria, Please visit Please visit Para No 13, TENDERER'S CREDENTIALS & ELIGIBILITY CRITERIA of Preamble Chapter of Approved Tender Document.
Technical Eligibility Criteria: The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, OR One similar work each costing not less than the amount equal to 60% of advertised value of the tender. Note:-Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. The similar work mean having experience of the following type of work-" Execution of any 25 KV AC OHE work". Important Note:- For Detail Regarding Technical Eligibility Criteria, Please visit Para No 13, TENDERER'S CREDENTIALS & ELIGIBILITY CRITERIA of Preamble Chapter of Approved Tender Document.
8 conditions · 3 needing a document upload
As mentioned in the Tender Document No.PUNE_ELECT_TRD_2025_20R1
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
As mentioned in the Tender Document No.PUNE_ELECT_TRD_2025_20R1
Replacement of OHE structure having less implantation, are leaning on Main line and Provision of proper Sectioning arrangement of OHE for isolation of Loop lines from Main line at station area for improving safety and reliablity of OHE at various locations of Pune Division.
PUNE_ELECT_TRD_2025_20R1
PUNE_ELECT_TRD_2025_20R1
Open
Works - General
12 Months
Pune, Maharashtra
₹0
₹4.6 L
6 Apr 2026
12 Mar 2026
23 Mar 2026
356 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,43,43,845.37 | ||
| — | 1500.00 | — | — | ||
| Digging, casting, grouting & muffing of foundation including cost of cement and material in other than hard soil & rock. (Foundation should be M-15 type as per IS-456, i.e ratio 1:2:4) | — | — | — | 1,13,60,250 | |
| — | 200.00 | — | — | ||
| Digging, casting, grouting & muffing of foundation including cost of cement and material in hard soil & rock. (Foundation should be M-15 type as per IS-456, i.e ratio 1:2:4) | — | — | — | 15,54,300 | |
| — | 30.00 | — | — | ||
| Preparation of design & drawing for overhead equipment. | — | — | — | 5,41,728 | |
| — | 65.00 | — | — | ||
| Supply of galvanized steel for structure | — | — | — | 78,00,000 | |
| — | 65.00 | — | — | ||
| Erection of galvanized steel for structure | — | — | — | 4,55,000 | |
| — | 65.00 | — | — | ||
| Extra charges for power block work for Erection of galvanised steel for structures | — | — | — | 2,60,000 | |
| — | 15.00 | — | — | ||
| Supply of galvanized small parts steel (SPS) | — | — | — | 18,00,000 | |
| — | 15.00 | — | — | ||
| Erection of galvanized small parts steel (SPS) | — | — | — | 1,05,000 | |
| — | 15.00 | — | — | ||
| Extra charges for power block work for Erection of galvanised small parts steel (SPS) | — | — | — | 75,000 | |
| — | 180.00 | — | — | ||
| Supply of a single bracket / cantilever assembly suitable for Coventional OHE with bracket and stay porcelain insulators. | — | — | — | 37,80,000 | |
| — | 180.00 | — | — | ||
| Erection of a single bracket / cantilever assembly suitable for Coventional OHE with bracket and stay porcelain insulators | — | — | — | 1,82,680.2 | |
| — | 180.00 | — | — | ||
| Extra charges for power block work for Erection of a single bracket / cantilever assembly suitable for Coventional OHE with bracket and stay porcelain insulators. | — | — | — | 1,82,662.2 | |
| — | 450.00 | — | — | ||
| Supply of hard drawn round copper for dropper wire, diameter 5 mm as per IS:282:1982. | — | — | — | 4,50,000 | |
| — | 2000.00 | — | — | ||
| Supply Contact wire Dropper clip (107) with locking wire as per RDSO Drawing no. RE/33/P/ 1181 Rev. G or latest. | — | — | — | 2,00,000 | |
| — | 2000.00 | — | — | ||
| Supply 65 Sq.mm copper catenary dropper clip assembly consisting of catenary clip SS bolt M-10X30X35 mm (10/16), spring washer B-10, Split pin 2.5X20mm, as per RDSO Drawing no. ETI/OHE/P/1192 Mod. C or latest. | — | — | — | 2,00,000 | |
| — | 2000.00 | — | — | ||
| Fabrication & erection of dropper assembly (Conventional OHE) including removal of old droppering. | — | — | — | 2,00,000 | |
| — | 2000.00 | — | — | ||
| Extra charges for power block work for Fabrication & erection of dropper assembly (Conventional OHE) including removal of old droppering. | — | — | — | 2,00,000 | |
| — | 1.00 | — | — | ||
| Manual erection of overhead equipment (Conventional OHE). | — | — | — | 42,470.62 | |
| — | 1.00 | — | — | ||
| Extra charges for power block work for Manual erection of overhead equipment (Conventional OHE). | — | — | — | 25,000 | |
| — | 15.00 | — | — | ||
| Supply of Contact wire splice (Toothed type) complete with stainless steel stud bolt M-12, 25/20 as per RDSO drg no. ETI/OHE/P/1080-1 Mod-C | — | — | — | 17,880.9 | |
| — | 15.00 | — | — | ||
| Supply of Catenary Splice (65) as per RDSO drg. No. ETI/OHE/O/1090 or latest. | — | — | — | 9,235.05 | |
| — | 15.00 | — | — | ||
| Splicing & extension of anchored over head equipment. | — | — | — | 33,978.6 | |
| — | 15.00 | — | — | ||
| Extra charges for power block work for Splicing & extention of anchored over head equipment. | — | — | — | 33,978.6 | |
| — | 20.00 | — | — | ||
| Supply of termination assembly for Conventional OHE (Including insulators) | — | — | — | 1,90,000 | |
| — | 20.00 | — | — | ||
| Erection of termination assembly for Conventional OHE (Including insulators) | — | — | — | 30,000 | |
| — | 20.00 | — | — | ||
| Extra charges for power block work for Erection of OHE termination assembly Conventional OHE (Including insulators) | — | — | — | 20,000 | |
| — | 10.00 | — | — | ||
| Supply of 3 pulley type ATD assembly for Conventional OHE as per 2X25 KV AT System. (Without Counter Weight ) | — | — | — | 4,00,000 | |
| — | 10.00 | — | — | ||
| Erection of 3 pulley type ATD assembly for Conventional OHE as per 2X25 KV AT System. | — | — | — | 36,028.3 | |
| — | 10.00 | — | — | ||
| Extra charges for power block work for Erection of 3 pulley type ATD for Conventation OHE as per 2X25 KV AT System. | — | — | — | 20,000 | |
| — | 10.00 | — | — | ||
| Erection of anticreep arrangement. | — | — | — | 40,000 | |
| — | 10.00 | — | — | ||
| Extra charges for power block work for Erection of anticreep arrangement. | — | — | — | 20,000 | |
| — | 30.00 | — | — | ||
| Supply of guy rod assembly | — | — | — | 2,59,093.8 | |
| — | 30.00 | — | — | ||
| Erection of guy rod assembly | — | — | — | 18,000 | |
| — | 4.00 | — | — | ||
| Supply of Section Insulator assembly along with all fittings including porcelain sectioning insulator & porcelain 9 tonne insulator suitable for Conventional OHE | — | — | — | 1,69,943.52 | |
| — | 4.00 | — | — | ||
| Erection of Section Insulator assembly along with all fittings suitable for Conventional OHE | — | — | — | 13,542.48 | |
| — | 4.00 | — | — | ||
| Extra charges for power block work Erection of Section Insulator assembly along with all fittings suitable for Conventional OHE | — | — | — | 8,000 | |
| — | 2.00 | — | — | ||
| Supply of 25 KV 1600 A Single Pole Isolator assembly with Insulators and pad lock (03 keys) | — | — | — | 1,50,000 | |
| — | 2.00 | — | — | ||
| Erection of 25 KV 1600 A Single Pole Isolator assembly with Insulators | — | — | — | 10,000 | |
| — | 2.00 | — | — | ||
| Extra charges for power block work Erection of 25 KV 1600 A Single Pole Isolator assembly with Insulators | — | — | — | 4,000 | |
| — | 2.00 | — | — | ||
| Supply of Integral lock for Isolator with 02 nos key. | — | — | — | 3,311.6 | |
| — | 10.00 | — | — | ||
| Supply of 25 KV Post Insulator | — | — | — | 60,000 | |
| — | 10.00 | — | — | ||
| Erection of 25 KV Post Insulator | — | — | — | 8,000 | |
| — | 5.00 | — | — | ||
| Supply of single earth electrode | — | — | — | 20,446.4 | |
| — | 5.00 | — | — | ||
| Erection of single earth electrode | — | — | — | 14,135.55 | |
| — | 5.00 | — | — | ||
| Supply for Extra forspecial embedment of earth electrode. | — | — | — | 10,523 | |
| — | 5.00 | — | — | ||
| Erection for Extra forspecial embedment of earth electrode. | — | — | — | 13,226.25 | |
| — | 10.00 | — | — | ||
| Supply of Porcelain 9 Tonne Insulator RI 6020-I (Minimum CD 1050 mm) conforming to RDSO Specification no.T1/SPC/OHE/INS/0070 (04/2007) with A & C Slip no.1 & 2 or latest for Cut-in Insulator/Suspension. | — | — | — | 32,000 | |
| — | 10.00 | — | — | ||
| Erection of cut-in Insulator assembly. | — | — | — | 7,122.7 | |
| — | 10.00 | — | — | ||
| Extra charges for power block work for erection of cut-in Insulator assembly. | — | — | — | 7,122.7 | |
| — | 40.00 | — | — | ||
| Erection of any type jumper assembly such as G Jumper, AT Jumper, Isolator Jumper etc . | — | — | — | 20,000 | |
| — | 40.00 | — | — | ||
| Extra charges for power block work for Erection of any type jumper assembly such as G Jumper, AT Jumper, Isolator Jumper etc | — | — | — | 4,000 | |
| — | 1000.00 | — | — | ||
| Supply of 40mm X 6mm Galvanized Traction Bond | — | — | — | 2,50,000 | |
| — | 1000.00 | — | — | ||
| Fabrication & fixing of 40mm X 6mm Galvanized Traction Bond | — | — | — | 80,000 | |
| — | 150.00 | — | — | ||
| Supply of Retro reflective type Location number plates. | — | — | — | 64,645.5 | |
| — | 150.00 | — | — | ||
| Erection of Retro reflective type Location number plates including clamps & nut bolt. | — | — | — | 12,897 | |
| — | 20.00 | — | — | ||
| Supply of 25 KV Caution Board in electrified area as per RDSO Drawing. | — | — | — | 7,897.6 | |
| — | 20.00 | — | — | ||
| Erection of 25 KV Caution Board in electrified area as per RDSO Drawing including clamps & nut bolts. | — | — | — | 1,725.4 | |
| — | 150.00 | — | — | ||
| Painting of "OHE Parameters" on OHE structures as per Drwaing no. BSL/TD/SK-441 | — | — | — | 7,743 | |
| — | 150.00 | — | — | ||
| Painting of "Location Numbers" on backside of OHE structures as per Drawing no. BSL/TD/SK-424 | — | — | — | 6,429 | |
| — | 10.00 | — | — | ||
| Painting of Counter Weight of ATD by Silver Paint & Painting of Location number on bottom 3 pieces of counter weight with similer colour of enamelled number plate. | — | — | — | 3,185 | |
| — | 150.00 | — | — | ||
| Transfer of equipment from one mast or support to another including old bracket removal. | — | — | — | 3,75,000 | |
| — | 150.00 | — | — | ||
| Extra charges for power block work for Transfer of equipment from one mast or support to another including old bracket removal. | — | — | — | 1,50,000 | |
| — | 2.00 | — | — | ||
| Dismantling of overhead equipment including SPS, DA, bracket etc but excluding structures. | — | — | — | 60,000 | |
| — | 2.00 | — | — | ||
| Extra charges for power block work for Dismantling of overhead equipment including SPS, DA, bracket etc but excluding structures. | — | — | — | 60,000 | |
| — | 10.00 | — | — | ||
| Dismantling of OHE termination assembly | — | — | — | 7,504.2 | |
| — | 10.00 | — | — | ||
| Extra charges for power block work for Dismantling of OHE termination assembly | — | — | — | 6,925.1 | |
| — | 10.00 | — | — | ||
| Dismantling of any type of ATD assembly | — | — | — | 25,000 | |
| — | 10.00 | — | — | ||
| Extra charges for power block work for Dismantling of any type of ATD assembly | — | — | — | 10,000 | |
| — | 10.00 | — | — | ||
| Dismantling of anticreep arrangement | — | — | — | 17,542.8 | |
| — | 10.00 | — | — | ||
| Extra charges for power block work for Dismantling of anticreep arrangement | — | — | — | 10,000 | |
| — | 20.00 | — | — | ||
| Dismantling of guy rod assembly | — | — | — | 10,000 | |
| — | 4.00 | — | — | ||
| Dismantling of Section Insulator assembly | — | — | — | 8,000 | |
| — | 4.00 | — | — | ||
| Extra charges for power block work for Dismantling of Section Insulator assembly | — | — | — | 4,000 | |
| — | 4.00 | — | — | ||
| Dismantling of Single Pole Isolator assembly including SPS | — | — | — | 8,000 | |
| — | 4.00 | — | — | ||
| Extra charges for power block work for Dismantling of Single Pole Isolator assembly including SPS | — | — | — | 4,000 | |
| — | 10.00 | — | — | ||
| Dismantling of cut-in Insulator assembly. | — | — | — | 5,000 | |
| — | 10.00 | — | — | ||
| Extra charges for power block work for Dismantling of cut-in Insulator assembly | — | — | — | 5,000 | |
| — | 30.00 | — | — | ||
| Dismantling OHE structures by cutting & transporting to Railway depot including loading and unloading. | — | — | — | 1,20,000 | |
| — | 75.00 | — | — | ||
| Breaking of foundation | — | — | — | 3,00,000 | |
| — | 500.00 | — | — | ||
| — | — | — | 2,53,750 | ||
| — | 500.00 | — | — | ||
| — | — | — | 5,92,950 | ||
| — | 600.00 | — | — | ||
| — | 500.00 | — | — | ||
| — | — | — | 1,35,700 | ||
| — | 1.00 | — | — | ||
| "Site visit for the collection of the data required for the structural design and drawing purpose with respect to the dimension of existing structure of the bridge & Preparation of General Arrangement Drawing & detailed design calculations & drawing for Bridge Mast" | — | — | — | 1,82,900 | |
| — | 10.00 | — | — | ||
| — | 10.00 | — | — | ||
| Supply of Catenary Wire Ending Clamp (65 Sq.mm) Part No.1121, 1092 &1094 with fasteners as per Drg NO.ETI/OHE/P/1120 Rev-B or Latest for Cut- in Insulator/Suspension | — | — | — | 5,636.6 | |
| — | — | — | 2,72,64,660.62 | ||
| — | 370.00 | — | — | ||
| Digging, casting, grouting & muffing of foundation including cost of cement and material in other than hard soil & rock. (Foundation should be M-15 type as per IS-456, i.e ratio 1:2:4) | — | — | — | 28,02,195 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022ACS-6_1.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
Advance
ATTACHMENT
AnnexureVA.pdf
ATTACHMENT
AnnexureVIA.pdf
ATTACHMENT
ApprovedTD_2025_20R1.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_2.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14_07_2022CS-1.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-311.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT
5-2023_10_20RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
2022-CE-I-CT-GCC-2022-POLICY-Pt.Idated25.09.2024_ACS-7.pdf
ATTACHMENT
2024_12_20IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_8ACS-8.pdf
ATTACHMENT
2025_01_09IIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_9ACS-9.pdf
ATTACHMENT
GCCACS-10-040325.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .