| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC HARIPUSHPA APARTMENT BUILDING NO E 1 FLAT NO 01 REST CAMP ROAD DEOLALI CAMP 422 401 | DEOLALI CAMP | NASHIK | MAHARASHTRA | 422401 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹30.0 L+₹7.0 L (30.4%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹31.0 L+₹8.0 L (34.8%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 |
| Sl No | Description | Qty | Unit | M/S PRAMOD SURESHCHANDRA AHER L2 | M/s.TIRUPATI BUILDERS L3 | Vinod Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Surface excavation n,exc 30cm deep and avg. 15cm deep and getting out in hard/ dense soil. | 199 | Sqm | 50 ₹9,950 | 199 ₹39,601 | 25 ₹4,975 Lowest |
| 2.00 | Excavation in trenches n.exc. 1.5 M wide and n.exc. 1.5 M in depth for foundation and getting out in Hard/dense soil complete all as specified and as directed by Engr-in charge. | 75.99 | Cum | 300 ₹22,797 | 450 ₹34,195.5 | 160 ₹12,158.4 Lowest |
| 3.00 | Excavation in trenches n.exc. 1.5 M wide and exc. 1.5 M in depth for foundation and getting out in Hard/dense soil complete all as specified and as directed by Engr-in charge. | 4.73 | Cum | 650 ₹3,074.5 | 550 ₹2,601.5 | 160 ₹756.8 Lowest |
| 4.00 | M&L cement concrete, 1:4:8 type D2 (40mm graded agg) as in foundation, filling & Mass concrete work complete all as specified and as directed by Engr-in charge. | 5.74 | Cum | 3,500 ₹20,090 | 4,800 ₹27,552 | 2,500 ₹14,350 Lowest |
| 5.00 | M&L for form work to sides of concrete foundation, footing, bases of columns, plinth beams and similar work, vertical or to batten rough finish flat surfaces on concrete all as specified. | 70 | Sqm | 375 ₹26,250 | 400 ₹28,000 | 350 ₹24,500 Lowest |
| 6.00 | M&L for form work to sides and soffit of floor or roof beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs etc also splays between floors and bemss etc rough finish flat surfaces on concrete all as specified. | 110 | Sqm | 400 ₹44,000 | 400 ₹44,000 | 350 ₹38,500 Lowest |
| 7.00 | M&L for form work to sides of Pillars, posts, struts piers, columns etc in squarre, rectangular or polygonal, rough finished surfaces of concrete all as specified. | 65 | Sqm | 420 ₹27,300 | 400 ₹26,000 | 350 ₹22,750 Lowest |
| 8.00 | M & L for form work to soffits of suspended slabs such as roof slab, floor slabs, landings and similar work, n.exc 200mm thick flat, rough finished surfaces of cencrete complete all as specified. | 120 | Sqm | 430 ₹51,600 | 400 ₹48,000 | 350 ₹42,000 Lowest |
| 9.00 | M&L M-25 (Design Mix) using 20mm graded stone aggregate in foundation including footing, plinth beam, base for column, etc complete all as specified and as directed by Engr-in charge. | 22 | Cum | 8,200 ₹1,80,400 | 7,500 ₹1,65,000 Lowest | 8,000 ₹1,76,000 |
| 10.00 | M&L M-25 (Design mix) using 20mm graded stone aggregate in for columns, pillars, piers, posts and struts etc complete all as specified and as directed by Engr-in charge. | 7 | Cum | 8,200 ₹57,400 | 7,500 ₹52,500 Lowest | 8,000 ₹56,000 |
Tender Value
₹31.5 L
EMD Value
₹60,000
Closing Date
26 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
PROVISION OF LAB ROOM IN KV SCHOOL AT AF STN OJHAR
2025_MES_713865_2
8325/E8
Open Tender
Civil Works
Item Rate
180 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹60,000
16 Sept 2025
2 Jul 2025
28 Jul 2025
3 Jul 2025
26 Jul 2025
7 Jul 2025
Amount
Surface excavation n,exc 30cm deep and avg. 15cm deep and getting out in hard/ dense soil.
Excavation in trenches n.exc. 1.5 M wide and n.exc. 1.5 M in depth for foundation and getting out in Hard/dense soil complete all as specified and as directed by Engr-in charge.
Excavation in trenches n.exc. 1.5 M wide and exc. 1.5 M in depth for foundation and getting out in Hard/dense soil complete all as specified and as directed by Engr-in charge.
M&L cement concrete, 1:4:8 type D2 (40mm graded agg) as in foundation, filling & Mass concrete work complete all as specified and as directed by Engr-in charge.
M&L for form work to sides of concrete foundation, footing, bases of columns, plinth beams and similar work, vertical or to batten rough finish flat surfaces on concrete all as specified.
M&L for form work to sides and soffit of floor or roof beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs etc also splays between floors and bemss etc rough finish flat surfaces on concrete all as specified.
M&L for form work to sides of Pillars, posts, struts piers, columns etc in squarre, rectangular or polygonal, rough finished surfaces of concrete all as specified.
M & L for form work to soffits of suspended slabs such as roof slab, floor slabs, landings and similar work, n.exc 200mm thick flat, rough finished surfaces of cencrete complete all as specified.
M&L M-25 (Design Mix) using 20mm graded stone aggregate in foundation including footing, plinth beam, base for column, etc complete all as specified and as directed by Engr-in charge.
M&L M-25 (Design mix) using 20mm graded stone aggregate in for columns, pillars, piers, posts and struts etc complete all as specified and as directed by Engr-in charge.
M&L M-25 (Design Mix) using 20mm graded stone aggregate in for slabs sopported on walls ,beams and columns in floor s ,roofs, Shelves, Cooking platform and similar work etc complete all as specified and as directed by Engr-in charge.
M&L M-25 (Design Mix) 20mm graded aggregates as in beams, cantilevers, bressummers, lintel over 1.5m span Complete all as specified and as directed by Engineer in charge.
S&F Mild Steel TMT round bars 10 mm dia and over, cut to length, bent to shape required, including cranking , binding spirally for hooping end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified.
Ditto all as per item No.13 above but 5mm dia and over up to & including 10mm dia in stirrups, spacers & binders complete all as specified.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:4
Material and labour for rendering 10mm thick internal surfaces in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement completed all as specified and as directed.
M&L 15 mm thick rendering on external surfaces in cement mortar 1:4 mixed with water proofing compound finished with even and smooth(water proofing compound to be measured under item no.25) Complete all as specified and as directed.
M & L 15mm thick rendering in cement mortor 1:3 on concrete surfaces as in ceilings (sunshade, chajja etc) and finishing surfaces even and smooth without using extra cement.
M & L for 75 mm thick Plain Cement Concrete type D 2 (1:4:8) using 40 mm graded stone aggregate as in sub bases, sub floors finished the surface even and rough complete all as specified and directed.
M & L for 25 mm thick Plain Cement Concretetype B-0, 1:2:4 (12.5mm graded aggregate) as in sub bases, sub floors finished the surface even and rough complete all as specified and directed.
M&L for Murrum filling in floors /laid in layers n.exc. 15cm thick,spread ,levelled and rammed including watering
M&L for hard core of broken stone or boulders of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surfce.
Material and labour for double charged full body Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick cement screed bed in cement mortar 1:6 including rubbing and mirror polishing complete all as specified and as directed.
Material and labour for double charged full bodyVitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick backing coat in cement mortar 1:4 including rubbing and mirror polishing complete all as specified and as directed. Note :- Skirting shall be made flush to wall
M&L for 10 mm thick rendering on RCC Roof top surface in cement mortar 1:3 mixed with WPC @ 3% by wt of cement finished the surfaces even and smooth complete all as specified . Note :- WPC shall be measured seperately as supply only.
Supply only integral water proofing compound.
M&L for cleaning the newly plastered surfaces thoroughly with wire brushes and providing water proofing treatment all as directed and given here in after (a) Bituminious primer @ 0.3 ltr per Sqm confirming to IS 3384-1986 on roof surfaces prior laying APP. (b) Providing water proofing treatment with polymeric APP modified bituminous membrane(weighing 3.2-3.5 kg/sqm) reinforced with non woven polyester mat of weight 160 gms/sqm as centre core applied by thermo fusion using LPG torch on the bottom portion of the membrane. (c) Applying two coat of bituminous aluminium paint @ 0.20 kg/ sqm over membrane (d) The cost also included for supply and fixing 75mm PVC (SWR) pipe (6 Nos) for rain water outlet from roof level to ground level.
M&L for providing powder coated Aluminium shutter and frame, with frame 88.9mmx47.63mmx1.6mm thick and size of shutter with top rail, middle rail and bottom rail and style of size 85mm x 44.5mm x 1.56 mm thick 200mm size powder coated 2 nos with each leaf, heavy duty powder coated aluminium tower bolt 150mm long 2nos per leaf, 3 nos heavy duty aluminium powder coated hinges of size 125mm with each leaf, 2 heavy duty powder coated aluminium handles 300mm including 12mm thick both side prelaminated particle board /5.5mm thick tinted glass pane in both panel with necessary joining cleats, rubber packing,aluminium beading, hydraulic door closer, screws etc complete all as specified and as directed. Note : Shutter may be single or double leaf, double leaf may be provided if width more than 1.1m and hollow section of vertical style where hinges are fixed it may be filled with soft wood and minimum 65mm long screw provided for fixing hinges
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
Material and labour for Aluminium powder coated sliding window with aluminium powder coated three track frame of size 116mm x 25mm & 1.6 mm thick with 3 Nos sliding shutters of powder coated aluminum section (top rail bottom rail and style of size 50mm x 25mm & 1.4mm thick) screwed to walls/floor including provn of tinted sheet glass panels of 4mm thick fitted in panels (2 Nos) and one shutter with stainless steel wire cloth 0.36 mm nominal dia and width of aperture 1.40mm with and including necessary locking device, jointing cleats, glazing clips, rubber packing beading , aliminum bidding and screws and silicon sealing around the frame etc. complete all as specified and as directed by Engineer-in-Charge..
M&L framed work such as grills grating etc with end of bars shoulderd and/or riveted . Welded or forged into spikes. Framedguard bars iron doors . Ladders framed balusters , walk ways . Railings , frame work of of water tanks and ssimilar work conforming to fe410.
S&F roller blinds digital printed/plain/zebra pattern including frame and pulling mechanism and all fixing accessories as approved, fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw compete all as specified as directed.
M&L for applying two coat of Synthetic enamal paint over a coat of red oxide primer on new steel based surfaces exc.10cm width or girth including preparation.
M&L for applying 1- 2 mm thick wall care putty in two layers on newly plaster surface of walls to achieve smooth complete all as directed.
M&L for preparation of newly plastered /wall care putty surface and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of newly plastered /wall care putty on celing surface and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M&L preparing new plastered surfaces of walls and applying two coats of Exterior acrylic emulsion Weather coat Anti Fungal over one coat of primer of approved shade and make complete as specified and directed.
M & L for 75mm thick cement concrete (1:3:6) type C2 using 40 mm thick graded stone aggregate as in plinth protection laid in alternate bays n exc 2.5m length finished even & fair and joint to be filled with Bituminous mastic filling all as specified.
M & L for 20 mm thick Granite (of any type) work (table rubbed and polished, rounded on edges) in steps, jambs, pillars, window-cills, cooking platforms, shelves and like jointed over and including 10mm thick cement mortar 1:4 screed and pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite, incuding grinding, moulding and polishing to exposed edges complete all as specified.
Refilling filling in including spreading levelling watering and well ramming in layers n.exc. 25cm deep as in hard/dense soil copletete all as specified .
Removing excavated material exc. 1km but n exc. 5 km and depositing where directed .
M&L for treating the top surface of filled earth at the rate of 5 Litres of Anti termite emulsion per square metre of surface all as specified
M&L for treating the soil under plinth protection at the rate of 5 Litres of Anti termite emullsion per square metre of surface area all as specified.
S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm
S&F Bip taps fancy (Swan neck) for 15mm dia bore of pipe, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S&F CP fancy Stop valves for 15mm dia bore of pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including supply and fixing ball valve(1 Nos), flange for connecting pipe,bends, tank adaptor as required complete all as specified.
S&F of 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S&F CP connections 15mm size with Brass nuts of length 600 mm
S&F 500 Litre Rotational moulded polyethylene water storage tanks(3 Layer) (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S & F 40 mm PVC flexible pipe for waste outlet with threaded socket at one end.complete all as specified and as directed by Engineer-In-Charge
S & F PVC (SWR) floor trap 75mm dia of outlet, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-charge.
S & F Grating of 125 mm dia of stainless steel with or without waste hole Complete all as specified and as directed by Engineer-In-Charge.
S&F Mineral Fibre acoustical suspended ceiling system with Bevelled/Tegular EDGE TILES with 15mm exposed or inward grid(projected ceiling tile) as approved. The tile should have humidity resistance (RH) of 99%, NRC 0.7, Light Reflectance > 85%. Thermal Conductivity k= 0.052-0.057 w/m k. Colour white Fire Performance UK Class 0/Class 1 (BS 476 pt-6&7) in module size of 600 x 600 x 19 mm suitable for Green Building application, with Recycled content of 43%. The tile shall be laid on Gl grid with 15mm wide T-section flanges colour white having rotary stitching on all T section i.e. the main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 14 Kgs/M2 & minimum pull out strength of 100 Kgs. The T section have a Galvanizing of 90 grams per sqm and need to be installed with Suspension system of J hooks 4mm dia wire rod, butterfly clips, as required on site of any shape and size. Make: USG/Knauf/ Armstrong, Anchor or equivalent.
Sand filling under floors or in foundations including watering and consolidation
M&L for rubber moulded Machine pressed precast concrete interlocking paver block with grey cement and no pigment ,any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade of approved make complete all as specified and directed.
M&L Plain cement concrete, 1:2:4 type B1 (20mm graded agg) as in coping etc including necessary formwork complete all as specified and as directed by Engr-in charge.
M & L for cement concrete 1:4:8 type D2 using 40mm graded stone aggregate in foundation, filling and mass concrete including filling around pipes. Complete all as specified and directed by Engineer-In-Charge
M & L for reinforced cement concrete pipe class NP-2 laid in jointed complete with collers bore of pipe 150mm complete all as specified and directed by Engineer-In-Charge. Make:- Hindustan/ Universal or equvilant confirming to IS.
M & L for cement concrete 1:4:8 type D2 using 40mm graded stone aggregate, bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested, in bore of pipe 150mm Complete all as specified and directed by Engineer-in-charge
M & L brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 as in manholes/ similar work including pointing flush the external face of the brick work as the work proceeds all as specified and directed by Engr-in-charge
M & L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in coping/channels in side the manholes/ benching etc including formwork and making the surface even and fair complete all as specified and directed by Engr-In-Charge
M & L for 15mm thick cement plaster in CM 1:4 on brick sufrace finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge
Extra for forming fair finished drain or channel 30 cm ineer girth in cement concrete, using extra cement including forms moulds mi-tred/stopped ends etc.
Cutting into existing manholes forconnecting ne drains making good to pipe and rendering cutting out existing benching for nad forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-I smooth finished and reforming benching as required (internal dia of pipe 150mm) completet all as specified and directed by Engri-In-Charge
Providing precast cement concrete type B1 1:2:4 using 20mm stone aggregate set in cement mortar 1:4 for landings cover slabs (for man holes etc) chullah hoods, chajjas water triughs mangers shelves and simliar articles with plain face complete all as specified and as directed by Engr-In-Charge
S & F for deformed or twisted bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends and binding with mild steel wire (annealed) not less 0.9mm dis. Complete all as specified and directed by Engr-In-Charge
M & L for PCC 1:4:8 type D2 using 40mm aggregate as in foundation filling and mass concrete complete all as specified and as directed
m & l for brickwork with subclass 'B' bricks straight or curved on plan exc 6m mean radius built in 1:4 cement mortar completet all as specified and as directed.
M & L for PCC 1:2:4 type C1 using 20mm stone aggregate as in coping etc including necessary from work complete all as specified and as directed
M & L for cement concrete 1:3:6 type D2 (using 40mm graded stone aggregate) as in bedding concrete to drain pipes 300mm dia including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified
M & L for extra for forming fair finished drain or channel 45 cm inner girth in cement concrete using extra cement including forms moulds mi-tred/stopped ends etc
M & L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surface finishing the surface even and smooth without using extra cement
M & L for two coats of cement base paint over by newly plastred surface including preparation of surface complete all as specified and directed
M & L for precast cement concrete type B1 (1:2:4) using 20mm graded aggregate as in drain covers set in CM 1:6
S & F deformed TMT bars 10mm dia & over cur to lemgth bend to shape required including crancking bending spirally for hooping & binding with & including mild steel wire (annealed) not less than 0.9mm dia ir securing with clips
S & F reinforced concrete pipes of dia 300mm dia, class NP3 laid and jointed complete with collars complete all as specified and as directed
Point wiring with PVC insulated and unsheathed multistranded FRLSH copper conductor single core 1.5 sqmm (nominal area) cable using approved colour code as per IS drawing in and incl heavy duty PVC concealed conduit wiring. not less than 25 mm which shall be increased as per site requirement with all accessories suitable for modular type fitment including provision for fixing of modular flush boxes of suitable size complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 1.5 mm as continuous earth wire connected to common earth dolly complete all specified and marking good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete and as directed Engr-in-Charge. (a) One light point/Fan point controlled by one switch.
(b) One 3 pin socket outlet 5Amps on the same board with other swithches.
Point wiring with PVC insulated and unsheathed multistranded FRLSH copper conductor single core 2.5 sqmm (nominal area) cable using approved colour code as per IS drawing in and incl heavy duty PVC concealed conduit wiring. not less than 25 mm which shall be increased as per site requirement with all accessories suitable for modular type fitment including provision for fixing of modular flush boxes of suitable size complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 2.5 mm as continuous earth wire connected to common earth dolly complete all specified and marking good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete and as directed Engr-in-Charge.
M &L for ceiling rose 2to 3 terminal PVC/polycarbonate, isolated body type suitable for AC 230 volts complete all as specified.
M & L for module cover plate with frame as per site requirements for following module complete all as specified and as directed. (a) 1 module
(b) 3 module
(c) 6 module
M &L for modular metal flush box as per site requirement complete all as specified and as directed. (a) 1/2 module
(b) 3 module
(c) 6 module
M & L for modular switch 1 way 6 Amp 1 module complete all as specified and as directed
M & L for modular switch 1 way 16/20 Amp 1 module complete all as specified and as directed.
M & L for modular socket 6A 2/3 pin universal 2 modular, complete all as specified and as directed.
M & L for modular socket 16A/6A 2/3 pin combined 2 module complete all as specified and as directed.
M & L for modular fan step regulator 120 well 2 module complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, anti suside road, clamps accessories complete with nut bolt, 230 V, 1200 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) Make : Havells Cat part Efficienia Neo BLDC or equivalent in orient, Crompton, Usha etc
S & F energy saving efficient 20 watt (4.0 feet) LED integrated batten type luminaries suitable for wall or ceiling mounting with built in LED chip & integral LED driver 20 watt, Aluminum channel housing & polycarbonate diffuser of length 1200 mm (approx), colour temperature 6500 K or as directed, CRI between 80-85 Low THD, PF-0.90(minimum), efficiency not less than 100 lumen/watt or total lumen output not less than 2000 lumen per 20 watt operating range 200-270V, surge protection of 2 KV over voltage protection and other safety tests as per IS 15886 Part -2/Part-3 estimated life span of 50,000 hrs with all accessories, complete with fixing arrangement, fitting shall be internally prewired and conforming to LM 79 & LM 80 standard, making all connection using 1.5 sqmm copper conductor multistandard PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connection complete all as specified and directed by Engr-in-Charge Note (i) LED fitting shall be provided for 3 years warranty.
S & F energy saving efficient 10/12 watt (2.0 feet) LED integrated batten type luminaries mirror type suitable for watt or ceiling mounting with built in LED chip & integral LED driver 10/12 watt. Aluminum channel housing & polycarbonates diffuser of length 600 mm (approx) Color temperature 6500 k or as directed efficiency range 200-270V surge protection of 2 KV estimated life span of 50,000 hrs with all accessories, complete with fixing arrangement fitting shall be internally prewired and confirming to LM 79 & 80 standard, making all connection using 1.5 sqmm copper conductor multistandard PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connection complete all as specified and directed by Engr-in-Charge (Note (i) LED fitting shall be provided for 3 years warranty (ii) Location for installation of LED fitting shall be as per approved drawing)
Supply and fix 36W LED Ultra-modern recess mounting luminaire with high performance LEDs, maximum 36 W 2x2 LED Panel suitable for mounting in Armstrong / 2x2 Grid ceiling which provides soft-light and glare free symmetrical illumination with CRCA powder coated Housing with sheet thickness of min 0.4 mm and with min 50 mm fixture Depth / height with glare free high translucent milky high grade diffuser with min 0.8 mm thickness . High efficiency long life LED package in integral module with lumen efficacy of >140 lm/W and viewing angle of 120° to ensure better uniformity with minimum System Lumen of 4300 Lumens with CRI > 80, Color temperature 5500- 6500 K, THD < 10% and PF > 0.95,IP20 , IK03.Life class of 50,000 hrs. @ L70, Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection: 4 KV; Protection : Reverse Polarity, Open & Short Circuit. DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. Fixture with R mark and registration number. As per Crompton Cat Ref: TCR-145-36-65-SL-NWH with 5 Year warranty from manufacturer or equivalent in Havells/Bajaj/Halonix Note for items Nos 2 to 10: (I) To write CA nos with date of installation on each fitting (any type) with permanent marker pen . (ii) Contractor is fully responsible for replacement of unsv fitting from OEM/Dealer. (iii) All reports and test certificate of light fitting submitted by contractor before payment. (iv) The rate of T&P reqd at site for replacement of LED fitting up to 15mtr height are deemed to be included in the quoted rates.
Supply and fix distribution board (DB), double (CRCA sheet ) dust and vermin proof SPN 8 way with appropriate Amps rated copper busbar, neutral bar, internal earth bar and cable tiles for cable management reversible door for iP 43 & IP 54, IK 09 impact resistance, single pole and neutral 250 volts ,flush to watt including chases cutting in wall for fixing good distributed wall surfaces to match with existing specification complete all as specified all as directed Note – Rates are inclusive for flush (concealed) mounting of DB SPN)
All as per Item No 97 above but, SPN 4 way with appropriate Amps rated complete all as specified all as directed Note – Rates are inclusive for flush (concealed) mounting of DB SPN)
Supply and fixing 240V, 10 KA ‘C’ curve miniature circuit breaker (MCB) single pols of current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning all as specified and directed.
Supply and fixing 240V, 10KA ‘C’ curve miniature circuit breaker (MCB) single pole and nutral of current carrying capacity 32 Amps, in the MCB DB complete with connection testing and commissioning all as specified and directed.
M & L sub main wiring using PVC insulated FRLS cable 4.0 sqmm and unsheathed multistranded FRLS copper conductor cable using approved colour code as per IS drawing in and intel PVC concealed conduit wiring with all accessories and making good disturbed surfaces of watt, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/color washing tom match with the existing surface complete as per specified and as directed by Engr-in-Charge of the following sizes of cables. Note : 2 runs of 4 sqmm copper cable ^ 1 run of 4.0 sqmm copper cable in and includingPVC concealed conduit wiring shall be measured as one unit.
S&F or exhaust fan 450mm sweep, heavy duty motor with double ball bearing ,metallic body with laid guard to protect the dan to running AC, single phase 230 volts, including connection with 1.5 sqmm multi standard copper conductor flexible wire from ceiling rose, complete with blades/frame and outside louvers with necessary fixing arrangement and making good to disturbed surface complete all as specified and directed.
M & L for Earthling compete with GI earth electrode plate of Size 600x600x6mm thick, buried directely to ground/earth pit not less than 2.25m deep below normal ground level, connected to GI wire 4 mm dia as earth lead up to test point with suitable GI nut/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 reinforced with expanded metal weight not less than 4 kg/sqm and frame of angle iron 25x25x6mm with lugs 02 nos with 5 mm dia MS bar handle made to shape excavation and earth work in any type of soil and including light grade GI watering pipe 20mm bore with funnel and wire mesh and light grade of earth wire protection pipe 15mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I ,connected to earthling testing point and testing on completion complete all as specified and directed by Engr-in-Charge.
Supply and laying LT UG cable with XLPE insulated armoured heavy duty electric power cable with aluminium conductor 1100V grade 4 core cross sectional area 10 sqmm laid in trench/duct/floor or passing through pipe all as specified and as directed byengr-in-charge.
All as per item No 104 here-in-before above but 2 core 10 Sqmm
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. of size 38 mm inner dia
Supply and errecting streel tubuler swaged poles type 410 SP-31 9 mtr long swan neck type complete with CI base plate anf finial and single swan neck including foundation complete all as shown in electrical plate No-5 of SSR part -I and testing on completion all as directed.
Material and laboure for plain cement concrete 1:4:8 type D2 using 40mm garded stone aggregate for5 foundation of Poles on etc all as specified and directed.
Supply, Installation, Testing and commissioning LED street light fittings 60 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-409-60-30-SL-GL-NSG or equivalent Havells/Phillips.complete all as specified and directed by Engineer- in-charge..
Material and labour for cable joint termination box PVC body housing suitable for housing and including 100 amps rated, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 amps MCB, SP, 240 volt for street light supply complete all as as directed by Engr-in-charge.
M&L for GI tubing medium grade with all fitting laid in trenches or fixed to wall or ceiling with clamps or fixed to floor complete all as specied and directed of size 15 mm bore.Make : Tata/Jindal/Prakash Surya
Drilling and tapping existing water supply mains ( in position ) for branch connections of internal dia of 15mm all as directed.
S&F stop valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for fixing with 15 mm iron pipe or for union complete all as specified and directed.
M/S PRAMOD SURESHCHANDRA AHER (BID ID -3371930)
M/s.TIRUPATI BUILDERS (BID ID -3358292)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .