Loading…
Loading…
Tender Value
₹22.6 L
EMD Value
₹45,102
Closing Date
28 Oct 2026, 3:00 pm
DVP(FMD)
HITES OFFICE TRIVANDRUM
Setting up of New Medical Gas Plant at JIPMER-Ramanathapuram, Puducherry, India
2026_HITE_293595_1
HITES/FM/JIP/MGPS/2026-27/02
Open Tender
Miscellaneous Works
Item Rate
120 days
Puducherry
Please refer Tender documents
2 documents required · 2 mandatory
₹590
Yes
HITES
₹45,102
Yes
6 Oct 2026
6 Oct 2026
29 Oct 2026
6 Oct 2026
28 Oct 2026
6 Oct 2026
Supplying, Installation, Testing and commissioning of 5 HP Vacuum pump mounted on the base, with all necessary controls, drainage traps, bacterial filters, Anti Vibration mountings and individual exhaust lines. The vacuum system shall in all respects comply with the recommendation made in HTM stanndards. The pump should be of rotary vane/ Reciprocating/Rotary Screw /Scroll pumps each of which shall be capable of independently producing designed systems flow rate. The pump shall have a built in non-return valve and pressure switch such that inadvertent reversal of the motor will not pressurize the reservoir or the distribution system. Pump should be capable of providing a vacuum of not less than 600 mm Hg (80 kPa).
Supplying, Installation, Testing and commissioning of 500 litre Vacuum compressor tank with differential pressure indications.
Supplying, Installation, Testing and commissioning of 5 HP Air Compressor operating at a minimum pressure of 4 Bar with Anti Vibration mountings, filter, non-return Valve, isolation valves etc. Each compressor shall be capable of supplying the system design flow rate on its own. An inlet filter and silencer shall be fitted to the outlets of each compressor.
Supplying, Installation, Testing and commissioning of 500 litre Air Receiver tank. The vessel shall incorporate all suitable lifting lugs and mounting feet and shall be complete with a relief valve, fusible plug and an automatic drain with manual by pass.
Supplying, Installation, Testing and commissioning of Desiccant 60 CFM Air Dryer With Filter, Each dryer assembly shall incorporate a dew point alarm to enable automatic changeover to the stand by dryer, in the event of changes in the dew point set range.
Supply and Installation of Air Cooler Tower Fan.
Supplying, Installation, Testing and commissioning of 5+5 Oxygen Manifold system with high-pressure copper annealed tail pipes with end brass adapter suitable for oxygen cylinders and manifold. 5 cylinder manifold bank as left side and 5cylinder manifold bank as right side complete with 10 nos. of pig tail pipes and required amount of non-return valves.
Supplying, Installation, Testing and commissioning of Semi-automatic control panel for Oxygen and the Manifold control panel should be digital/analog without fluctuation in delivery supply line pressure. The control panel should have a microprocessor based digital /analog display panel.
Supplying, Installation, Testing and commissioning of Emergency 5 Oxygen Manifold System.
Supplying, Installation, Testing and commissioning of Piston Type Oxygen Regulator for Emergency Manifold.
Supplying, Installation, Testing and commissioning of 1+1 N2O Manifold with tailpipe, Non Return valve and MOX Regulator.
Supplying, Installation, Testing and commissioning of Single N20 Manifold with tailpipe, Non Return valve and MOX Regulator.
Supplying, Installation, Testing and commissioning of Single Arm Medical Gas pendent with 0-330 degree level rotation, extension arm and terminal which includes Medical gas outlets Oxygen: 2 nos, Vacuum: 2 nos, Medical air: 2 nos, N2O: 2 nos, Electrical 5-15 amps switch and socket:10nos. The pendent should be of Ceiling mounted installation reliable and firm with a net weight of 150kgs and ward vacuum unit clamps.
Supply and installation of DIN outlet for Oxygen - 9 Nos , Vacuum - 10 Nos , AIR - 2 Nos and N2O - 2 Nos.
Supplying, Laying and Testing of solid drawn seamless, deoxidized, non arsenical, hard, tempered and degreased copper pipes as per approved Medical standards. The work shall include all type of specials (same grade) like tee elbow coupler reducer etc, laying of pipes on ceiling/walls including painting of copper pipe with code colour, suitable gas welding etc. and complete pressure testing. The copper pipelines should be tested to be suitable for a steam working pressure of 17.34 kg./cm2 (17 bar) and conform to BS 864 Standard with specially made for brazed socket type connection.
28mm dia x 1mm thick Medical gas pipeline
22mm dia x 1mm thick Medical gas pipeline
15mm dia x 1mm thick Medical gas pipeline
12mm dia x 1mm thick Medical gas pipeline
Supply and fixing of Single O2 Flowmeter and Humidifier with Probe.
Supply and fixing of 600ml ward vacuum suction jar with regulator and probe full set.
Supplying, Installation, Testing and commissioning of 4 gas Medical alarm box with digital display, necessary fittings etc
Supply and fixing of Bed head panel 17 Feet with double railing Din Outlet Oxygen-6 Nos., Vacuum- 3, Air - 3 Railing Suction Bracket -3 No. and 2 Set of 9Module Switch and Socket.
Supply and fixing of 8mm threaded rod & holding slotted channel including anger fastener with nut and washer.
Supplying and fixing of 28mm Isolation Valve with necessary fittings.
Supplying and fixing of 22mm Isolation Valve with necessary fittings.
Supplying and fixing of 15mm Isolation Valve with necessary fittings.
Supplying and Installation of Janatic regulator type Pressure Reducing Station (PRS System) for Air Compressor including isolation valve with necessary fittings.
No Rupees Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tender documents_Vol1NIT.pdf
Tender Documents • 0.55 MB
Tender documents_Vol2GCC.pdf
Tender Documents • 1.04 MB
Tender documents_Vol3SCC.pdf
Tender Documents • 4.29 MB
Tender documents_Vol4TS.pdf
Tender Documents • 0.31 MB
Vol5BOQ.xls
Other Document • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .