Loading…
Loading…
Tender Value
₹2.1 Cr
EMD Value
₹4.2 L
Closing Date
25 Jun 2026, 3:00 pm
Reliability improvement by means of repairs, restoration/ maintenance of signaling assets under the jurisdiction of SSE/Sig/BPB/IC.
SNT-01-LMG-2026-27-RT
SNT-01-LMG-2026-27-RT
Open
730 Days
Unknown (Unspecified Location)
₹0
₹4.2 L
3 Jun 2026
3 Jun 2026
11 Jun 2026
A-Outdoor: Supply & Execution
Supply of High intensity grade retro-reflective sheet as per railway specification IS:736 (Color Yellow/RED)
FRP Type Hood for main Colour Light signal units as per RDSO spec No RDSO/SPN
FRP type Hood for Route indicator as per RDSO Spec No. RDSO/SPN/194/2006 &
FRP type Hood for Shunt Signal unit as per RDSO Spec No. RDSO/SPN/194/2006 &
Supply of Colout Light Signal Unit complete, FRP TYPE to Drg. no. IRS:S-26/64 ver.1.0 or latest, SA 23003 A/M (Adv.) or latest without CLS transformers, lenses, lamps, lamp holders.
Excavation, ramming, Casting Cement Concrete foundation for Position Light Shunt Signal Post in the ratio of 1:3:6 Aggregate not exceeding 3 : 8 cm, as per Drawing of CSTE/NFR and technical specifications using standard size galvanized Anchor bolts & nuts (also referred to as foundation bolts) conforming to IRS Drg. No. SA- 116A/M, for erection of colour light signal post, plastering with 1 : 4 cement - sand mixture all the surfaces up to 75 mm below ground level, complete with contractor's material including cement, sand, aggregate, anchor bolts and nuts and curing of casted foundation, refilling & ramming of loose soil around foundation and disposal of loose dugged soil from site.
Assembling, erection, installation, taking of cable inside unit through post, 9 termination and wiring of CLS complete with all accessories of CLS unit, post, base, ladder, ladder guards, platform and MS supporting bracket in the middle of the ladder, hoods, pinacles, offset brackets, Junction/stencil type route indicators (if any) - 1 way to 6 way, etc. including fixing & wiring of LED units lamps with contractor's wiring material as per RE requirement.
Supply and fixing of protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per std. practice in RE Area. 2
Fabrication, supply and fixing of P, C, A, G, R, AG etc. marker disk painted and 11 lettered with enameled paint of approved colours, on signals, conforming to RDSO Drg. No.SA - 23456, as per standard practice and technical specifications, with contractor's complete material including fixing clamps.
Supply, Fabrication and Fixing of Retro reflective Signal Number Plate of standard size and drawing as per SEM, high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing posts as per standard practice.
Installation of Signal number Plates with supply of Clamp, nut bolts & other required material as per per direction of Consignee or his authorized representative at site. (Supply of Signal Number plate is not included in this).
Installation of Goods Warning Board/ Calling On legend board or other similar board 14 with supply of MS angle frame with fixing clamps, post & other required materials. Making foundation, complete with contractor' material, as per as per per direction of Consignee or his authorized representative at site. (Supply of any Board is not included in this).
Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 15 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). Wherever depth of 0.5 m cable trench is not feasible, cable shall be protected as: - Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.
Supply of Point JB fitted with 18 nos. 1-way terminal block fixed on hylum sheet with 16 U channel (75x40x1500) mm for fixing ARA terminalconfirming to IRS-S-75/2006 (REV.2.0) OR LATEST, DRG. NO. SA-23741A with 3 no. of 40 mm bore G I PIPE 600 mm long to be procured from RDSO approved sources.
Supply of full-size apparatus case (Large) (as per DRAWING NO. RDSO/S-11500 or 17 latest). This includes supply of location box with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500.
Supply & fixing of Hylam sheet 10mm thick of various size of minimum grade P2/P3 on apparatuscase/Location boxes for wiring of signaling circuit and cable termination, fixing on 19 suitable size contractors angle with string rod for supporting cable on back side including fixing of all types of terminal /fuse as per location diagram plan and technical specification with drilling of holes on either side of terminals /fusesand other places as required forcable conductor/wires entry and fixing of sheets.
Casting, concreting and curing of concrete foundation ((in ratio 1:3:6), erection and installation of full-size apparatus case with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, 20 bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti- corrosive paints as per IS: - 9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside.
Fixing by slotted angle, wiring of terminal strips, hylam strip, relays, fuses with base, fixing of hard wood shelves for full size apparatus case with termination & Earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and 21 miscellaneous materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO'S approved firm and to be inspected by RDSO. [Quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor.
Casting, concreting and curing of concrete foundation (in ratio 1:3:6), erection and installation of half size apparatus case ( with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, 22 bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti-corrosive paints as per IS: - 9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside.
Fixing, wiring of terminal strips, hylam strip, relays, fuses with base and supply and fixing of shelves for half apparatus case with termination earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and miscellaneous 23 materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO's approved firm and to be inspected by RDSO. [quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor.
Strengthening of foundation of signals, Full/Half location boxes, by carrying out earth 24 work around the foundation, ramming of refilled earth, carrying out masonry work from bottom of earth work using country stones & cement masonry to prevent the earth from slipping down the bank. This also includs supply of required masonry materials.
Alteration/modification in the existing location boxes (Full size), fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same.
Alteration/modification in the existing location boxes (Half size), fixing of 26 equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same.
Taking all types of cables inside LC Gate hut, location boxes and junction boxes etc. and sealing of cable entry pit etc. as per Technical specifications, complete with contractor's material.
Taking the all types of cablesinside station relay rooms, ASM'sroom,location huts, 28 locationboxes and junction boxes etc.and sealing of cable entry pit asper Technical specifications,complete with contractors'material. Per
Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location 29 boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc. under supervision and instructions issued by Engr. In-charge of the work.
Dismantling of location box / RCC Goomty including all its accessories & concrete foundation.
Supply of Automatic change oversystem of Track Feed battery Charger model No. BE-TFBC or similar.
Installation of Automatic changeover system of Track Feed battery Charger model No. BE-TFBC or similar as per instruction of site supervisor.
Supply of Track Lead Junction Box (TLJB) made from FRP material including brass bolts and hylum board sheet with terminals etc. The technical specifications are as follows:(a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W- 212mm and H 90 mm and all the holes required for mounting on FRP stump (vertically two for each FRP angle) HDPE pipe , cable etc.(b) Each TLJB shall have two Bakelite terminal block fitted 33 horizontally : each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be supplied.(c) HDPE pipe of size 32/35mm , 380 mm long along with two nuts for fixing on the TLJB hole .(d) The FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using alvanized nuts and bolts. The TLJB and the angles for stump should come along with holes on them for fixing using galvanized nuts and bolts of adequate strength to be supplied along with TLJB.
Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (FRP stumps) with contractor's fixing material. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site.
GI wire 8 SWG soft (4 mmdia) as per IS-279/72 or latest amendment suitable for track circuit rail bonding
Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 Amdt. 1 & RDSO Drg No. S-69/M.
Insulated cable for TLJB application made of copper alloy material, tin plated, non- corrosive size 3/16"with sheath as per specification No. IRS:S-103/2004 or latest.
Provision/Installation of bonding with GI wire 4mm dia (8 SWG) for track jumper & fish 38 plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia. holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site.
Charging of lead acid cell (Secondary cell) of various capacities as per 41 Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by consignee. This includes installation and commissioning of battery in circuit. Battery to be kept on wooden rack.
Supply of Self-Regulating Type Battery Charger, 230V AC/60V DC, 50/60 Amps as per RDSO Specn.No.IRS:S- 86/2000 (Amnd.4) or latest.
Supply of Self-Regulating Type Battery Charger, 230V AC/60V DC, 50/60 Amps as per RDSO Specn. No.IRS:S- 86/2000 (Amnd.4) or latest.
110V DC/ 230V AC 3 KVA Coventional Inverter for converting 110V DC of 110V Battery bank to 230V AC
Supply of 110V DC Point Motor with 400V AC immunity as per Specification No. IRS:S:37-2022 Version 2.0 or Latest with IP-67.
Supply of Electric Point Machine (Non-Trailable Type), 110V DC, 143 mm stroke as 46 per Drg. No.:RDSO/S-10800 Spec: IRS: S-24/2025 Rev.3.0 or latest, complete with junction box and two nos.of telescope pipes for each machine. Set of insulated tools in suitable tool box to be provided along with every set of eight point machine or less (Motor of Point machine to be supplied of 400V AC immunity Spec: IRS S37-2022 VER 2.)
Installation, wiring and associated work such as drilling of switch, installation & adjustment of ground connection of 110V DC 143 mm throw point machine with removal of existing 47 Point machine as per standard practice and direction of supervisor incharge. It include supply and fixing of bend pipe for taking tail cables inside point machine. All the required consumable stores viz lugs of suitable sizes, nuts & bolts, washer etc. for completion of the entire work should be supplied by the contractor.
Point insulation Complete set as per RDSO/SPN/168/2005 Rev.2, with amdt. up to date if any for 1.Switch bracket 'D' and 'L' bracket insulation for IRS point machine - One set comprises of (a)Side plate LH to Drg.No.S-3266 - 1 No. (b)Side plate RH to Drg.No.S-3265 - 1 No. (c)Insulating bush to Drg.No.S-3199 - 4 Nos. (d) Insulating washer to Drg.No.S-8640 - 4 Nos., 2. Split- Stretcher bar 2.1 Insulation for Leading stretcher bars (BG) each set comprising of (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg.No.T-10384 - 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg.No.T-10535- 4 Nos. (c) 48 Insulating Washer for insulated stretcher bar BG as per RDSO drg.No.T-10371 - 6 Nos. 2.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg.No. T-10367 - 3 No. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg.No. T-10368 - 6 Nos. (c)Insulating washer for insulated stretcher bars BG as per RDSO Drg.No. T10371 - 12 Nos& 3. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washer each set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg.No.T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg.No.T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg.No.T-10371 - 6 Nos.
Power Pack for Rly Motorised Gate (ELB) input 110V AC/DC, Output 24V DC/22A Model: GALLANT-PS 3222 or similar.
32 feet new octagonal boom in 4 sections as per RDSO approved Drawing No. RDSO/S/11600 as per Technical Specification
LED indicator different colour for ELB Panel as per RDSO specification No. RDSO/SPN/208/2012 (Ver.2) or latest.
LED Type Boom Light with MS Box frame, protective mesh & Acrylic Round Lens for Boom of ELB as per RDSO specification No. RDSO/SPN/208/2012 (Ver.2) or latest.
Supply of Electrically Operated Lifting Barrier complete set suitable for 24V DC, supply with hand generator back up & motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 with latest amendment. One set consisting of 2 nos. of lifting barrier pedestals, each with 8 contact circuit controller with top roller type limit switches, hand crank, 2 electric motors, 53 24vdc of capacity suitable to operate barriers up to 32' long booms, 2 nos. of octagonal booms of 32 feet length with 2 nos. Stop boards, boom light boxes, MS counter weights and 2 nos. of boom support with motorized boom locking but without fringes along with control panel with buttons and indicating lamps, motor connectors and MCB and hand generator (24VDC) to operate 2 barriers of 1 set. This includes supply and installation of gate hooter - 1 no and Dual Tone Bell /Buzzer with Flasher arrangement and 20-Watt horn working on 24 V DC/ 110 V AC (as specified in Tender Document)- 1 no with all fixing arrangements. All of the above items including supply of nuts & bolts, foundation as required & supply of cement, civil work materials and etc. Shall be done by the contractor for commissioning. Only 230VAC supply shall be arranged by the railway in nearby relay room. The complete electric lifting barrier set shall confirm to RDSO SPEC NO. RDSO/SPN/208/2012 Ver. 2.0 Amdt. 1or latest amendment. along with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2 as below - Following spares shall be supplied along with each set (02 nos.) of Electric lifting barrier as per requirement of the purchaser i) Octagonal boom - 1 no. complete. ii) Belt - 1 no. iii) Crank handle - 1 no. iv) Motor Contactor - 1 no. v) Motor protection MCB- 1 no. vi) Push button complete- 2 nos vii) Limit switch - 3 nos. (1 lever type and 2 top roller type) viii) Fuses used - 2 sets - Tool kit consisting of standard sizes of wrench / spanner and Allen keys should also be supplied with each set (02 nos.) of Electric Lifting barrier.
Supply of Electrical key transmitter rotary type as per IRS-S-21/2001 Rev.1 , Drg. no.SA-22601 Alt. 4 with the key and of the Ward No. as per approved signalling plan or as per instruction of Engineer-in-charge.
Installation, wiring, testing and commissioning of electrically operated lifting barrier, 55 complete with Casting of cement concrete foundation (including supply of sand, stone, cement, bolt, plate etc.) for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc.
Design of circuits and plans to suit layout given in the signalling plan of IBS/ABS/LC GATE. All plans and wiring diagram shall be prepared on Auto Cad Drawing and supplied with CD. This will include supply of Control cum Indication panel diagram, Route section plan, square sheet, wiring diagrams, Relay rack/Relay arrangements, Bus bar details, Fuse analysis, contact analysis, Relay room tag block analysis, panel tag block analysis, Power panel diagram, IPS wiring diagram, Auto change over diagram, Power equipment arrangement with program switch, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings. NOTE: The contractor 56 shall initially supply 2 sets of documents (Paper Prints) for approval of Railways. Railway will return one set to the contactor duly approved with alterations/corrections, if any. The contractor shall incorporate Railways' alterations/ corrections/ comments, if any, in the tracing & CD without any deviation and submit all the tracings and Final CD complete with all respect for Approval of Railways. After Approval of Railways on the tracings, the contractor shall submit 3 sets of final approved diagrams to the Railways within 15 days. He shall ensure that each sheet has a block for signature of railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each IBS/ABS/LC Gate.
Concrete foundtion for pedestal of lifting barrier as per tech specs. (All required masonry materials including grouting Bolts & Nuts are to be supplied by the contractor)
Concrete foundation for gate barrier rest post with grouting bolt as per tech specn. (All required masonry materials to be arranged by the contractor with grouting bolt).
Welding of Gate boom, roddings etc and its reinstallation as per technical specifications. (Nos= Each joint)
Supply of Medium class GI pipes 80 mm dia (4 mm thickness) as per IS 1239 (Part 1): 60 2004 or Latest with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends.
Supply of Medium class GI pipes 50 mm dia (3.6 mm thickness) as per IS 1239 (Part 1): 2004 for use in ASM room and at any other location as decided by Site Engineer. It includes supply of all material required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges and sudden bends.
Supply of HDPE DWC pipe of size 90/76 mm dia nominal - as per RDSO Specification 62 No.RDSO/SPN/204/2011 version 1.1 Amd. 1 or latest TEC specification No. with Anti Rodent and Anti- flammable property - along with socket, coupler etc. - as per technical specification and as approved by Engineer-in-charge
Excavation of trenches in all types of soils including soft rock as per including cutting and clearing of bushes and roots of trees etc., upto a depth of 1.2 Mtrs and width of 0.3 Mtrs at the 63 bottom in the entire section, back filling and ramming of the soil in trenches to original level. The work shall be executed as per technical specification. NOTE: Proportionate payment against the work executed by the contractor will be arranged where digging of trench upto 1.2 mtr depth is not possible due to water seepage inside the trench, this has to be confirmed by the railway representative present at site and should be recorded in the field book.
All works of Excavation of cable trench 1.0 M deep , 0.3 mtr wide on pucca platform/Pucca Road and placing of GI pipe, and restoration of the platform /Road surface to the original condition after cable laying and refilling the trench. Necessary materials e.g. GI pipe, 64 cement, sand, stonechips, mortar have to be supplied by the contractor.The work should be done as per specification. NOTE: Proportionate payment against the work executed by the contractor will be arranged where digging of trench upto 1.0 mtr depth is not possible due to water seepage inside the trench, this has to be confirmed by the railway representative present at site and should be recorded in the field book.
Digging of 1.0 Meter deep and 0.3 Meter wide trenches In hard soils including hard rock and Soil mixed with ballast/Stone/Bricks, including clearing of roots of trees and bushes and temporary obstruction on the selected route back filling and ramming of the soil in trenches to 65 original level., as per technical specifications and cable route plan. Note: In case where digging of trench up to 1.0 Meter depth and 0.3 meter wide is not possible or bigger size trench is required to lay more cables or loose soil/ muck is encountered, the depth can be reduced / increased as per directions of the Engineer-in-charge of the works, the payment will be decreased/increased proportionate to the depth & width of excavation compared to 1.0 Meter deep and 0.3 Meter wide.
Excavation of trench to a depth of 1 Mtr. for track crossing of cables, laying of DWC/ RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the 66 instructions of Railway representative at site. During excavation of trench it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule).
Transportation of HDD machine with accessories including handling of stores materials, supply of HDPE/DWC pipe of various sizes as per instruction of Engineer in Charge, preparation of site ,entry and exit pit (1mX1mX1m) and boring for placing of HDPE Silicore 68 duct/DWC of various dia size as per instruction of site engineer for 6Quad Cable/OFC cable/other cables for crossing Track/PuccaRoad/Congested area. Boring trench shall be minimum 3 (three) meter below the river bed/Track and 1(one) meter below the road/pucca road crossing area.Track/Road includes supply of accessories for pulling HDPE pipe. All other petty materials with earthwork, jointing of duct is to be done by Contractor.
Laying & Fixing of Medium class GI pipes 50/80/100 mm dia as per IS 1239 (Part 1): 69 2004 with socket & coupling, nuts, bolts, MS angle, MS Flat etc. on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work as required to protect the cables from sharp edges and sudden bends.
Laying of underground signalling/ power/telecom cables of various sizes in trench, at bridges in pipes, in road crossing, platforms & across the track through GI/DWC/HDPE pipe as per technical specifications.
Protection work of cable over boulder pitched / high cutting area, culvert, in yard, 71 rocky,congested / residential area using HDPE pipe and covering it making continuous square block of 1:2:3 massionary work as per site condition.Minimum 10 cm layer of concrete to be made and then covered with soil. Minimum depth of concreted portion to be maintained at 500 mm from ground level. All required materials i.e. HDPE pipe, cement, sand, aggregate, etc. will be supplied by the contractor.
B-Indoor & Miscellaneous: Supply & Execution
Track Relay QBAT, AC immunized, 2F-2B contacts, 9 ohms. Complete with plug board, retaining clip & connectors as per RDSO/SPN/84 Ver 2.0 Amdt. 1 or latest. The interlocking code for this unit shall be "ABEJX".
Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V DC 2 complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No.IRS: S-34 & S-23with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDEG".
Contactor Unit (QBCA1 Type), 24 V DC, 2F(HD)/4B or 2F(HD)2F-4B complete with 3 plug board (base plate), connectors, retaining clips etc. and conforming to BRS- 943 and RDSO Specn.No.IRS:S-34 & S-23 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be "BCEJK" or "DEHJX".
Q-Series LED ECR (Universal Type i.e. QECX), 4F/4B complete with plug board (base 4 plate), connectors, retaining clips etc. and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt. -1 and RDSO Specn.No.IRS:S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDHK".
Supply of Non detoriating type low voltage cartridge electric fuse 2/4Amps with cyndrical head end cap as per Spec NoIRS/S/78/92 with latest amendments .
Supply of Non detoriating type low voltage cartridge electric fuse 6/10Amps with cyndrical head end cap as per Spec NoIRS/S/78/92 with latest amendments .
Supply of Non detoriating type low voltage cartridge electric fuse 16/20Amps with cyndrical head end cap as per Spec NoIRS/S/78/92 with latest amendments .
PVC INSULATED SHEATHED SINGLE CORE FLEXIBLE COPPER CABLE 2.5 SQ, STRANDED FOR WORKING VOLTAGE UP TO AND INCLUDING 1100 VOLTS.
Supply of 1 x 35 Sq.mm. (Red/Black/Green) multi strand copper power wire as per IS: 9 694:2010 or latest, 276 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.554 ohms/km and test parameters as per RDSO Specn. No.IRS: S76/89(Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer in charge.
Supply and installation of housing cabinet of suitable dimensions to house VDU control terminal along with CPU, one set of input device (Keyboard and mouse etc.), monitor and 10 power supply arrangement . The detailed drawing of the cabinet along with placement of various equipment inside the cabinet shall be submitted by the tenderer and got approval by the railway before supply . Dimensions shall be similar to as available in IRSEM or suitable for existing dimensions of SM's room at station.
Supply and installation of maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest, TAN 3006 ver. 3.0 or Latest . Necessary testing certificate of UL, IEC to be produced. Supply of Basic Materials Includes: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (Total 30-35 KG) (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC 11 insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipment to SEEB (v) Supply of copper lug sleeve for 3/16 cable Installation Includes: (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Minimum: 30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipment. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential bus bar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential bus bar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest.
Supply and installation of Earth electrode for outdoor equipment consisting of 2.5 meter G.I. Pipe medium grade having internal dia of above 38 mm GI pipe, perforated shall consist of spike at one end and a lug at the other for connecting the earth lead wire.
Supply of Earth electrode for outdoor equipment having G.I. pipe one end spike and 13 other end having a lug for connecting the earth lead wire / MS flat for earthing including M10 steel screw and nut, consisting of 2.5 meter perforated G.I pipe medium grade having internal dia of above 38mm GI pipe shall consist of spike at one end and a lug at the other for connecting the earth lead wire.
Installation of Earth Electrode including supply of MS flat (with peripheral earthing of apparatus case) for signalling Equipments as apparatus cases, signal,relay rack etc.
Supply of MS Flat of size 35mm x 6mm for perimetric earthing as per SEM and CSTE/NFR's Drawing No.SK/21/00071 or latest.
Copper tape 25 X 3 mm for interconnection of earth electrode or making equipotential bus bar etc as per technical specification
Provision of cement concrete enclosure for earth electrodes as per NFR standard practice. This includes supply of all materials by the contractor duly inspected by consignee.
Exothermic welding in relay room ,IPS or any indoor room as per RDSO's TAN No. STS/E/TAN/3006 ver 3.1 or latest as per TS.
Exothermic welding for any outdoor Work for earth connection as per as per RDSO's TAN No. STS/E/ TAN/3006 ver 3.1 or latest as per TS.
Supply of Charge Controller, 110V/60A of 5.76 KWP Solar Power Generating System for IPS battery charging, Make - Mahadev Saur Urja Projects Private Limited or similar.
63A DPC Plastic MCB Double Pole C Curve as per TS.
Rotary cam switch 63A rated capacity suitable for 250VAC , Type N4Y29B/YR or similar of Kaycee make.
63 A Fuse with Fuse Holder for 230V AC application. Installation at 230V AC input power supply of IPS or similar. Make- Bussmann or similar.
105 Ah, 12V Battery EXIDE GENPLUS MODEL:EXIDE GP115E41L or similar
Supply of SMPS based battery charger, 12 Volt suitable for charging above battery for DG Sets.
SM's Key for Domino Panel as per TS
RRBU key for Domino Panel as per TS
Gate Man's Key for Gate Operatingh panel as per TS
LED Indication (Red or Yellow) for DG/SEB changeover box, 230V. (Colour as per requirement)
LED suitable for Deltron make block panel & UFSBI as per technical specification.
Supply of CCC card (Control Communication Card) Compatible with existing UFSBI System of Make/Brand: Deltron
CPU CARD COMPATIBLE TO WORK WITH EXISTING UFSBI AS PER SPECIFICATION NO. IRS:S-105/2012 VER.0.OR LATEST. MAKE/BRAND:- DELTRON OR SIMILAR. Accepted Make/Brand:- DELTRON
Supply of Output card compatible with existing UFSBI system Deltron make as per RDSO specification No. IRS : S-105/2012 ver 0 Make Brand DELTRON MAKE
Input Card Compatible with existing UFSBI System as per RDSO Specification No.IRS: S:105/2012 (Version.0), Make Deltron Equipments & System (P) Ltd. Make Brand - DELTRON MAKE
Supply of Modem for UFSBI for use with secondary media OFC/Quad. The modem shall be complete with existing system as per RDSO/SPN/147/2005 with amendment -1 or latest.
Supply of Automatic Media changeover system of Modem working on redundant channel for data transmission on OFC/Quad/ microwave radio, for seamless operation of UFSBI over multiple media.
Supply and installation of Push Button Switch of Make L&T or SIEMENS with paralleling of NO/NC contact in block panel of UFSBI of Deltron Make Equipments and systems as per RDSO Specification No. IRS:S:105/1012 ver.1.0. (Black or Red as per requirement).
Block Telephone (Complete with PTT Handset) suitable to working with block panel & UFSBI make as per IRS spec. no. IRS:S105/2012 ver.0 or latest
Supply of Key Switch with 1 NO + 1NC or 2 NO Config. Of ESBEE make, suitable to work with Block Panel of Deltron make as per RDSO Spec.No.IRS-S-105/2012 VER.0 or latest
DC-DC Converter card for GG Tronic make HASSDAC as per RDSO specification No.RDSO/SPN/177/2012 with version 3.0 or latest with RDSO inspection Make/Brand:- GG Tronics. RDSO Item ID: 3100268 Sub Item ID: 3100268002.
PCB MODULE CENTRAL PHASE DETECTOR CARD 1-21 KHz (PD 1) COMPATIBLE FOR HA-SSDAC OF GG TRONICS MAKE Firms accepted offer Make/Model: GGT
PCB MODULE CENTRAL PHASE DETECTOR CARD 2- 25 KHz (PD 2) COMPATIBLE FOR HA-SSDAC OF GG TRONICS MAKE Firms accepted offer Make/Model: GGT
Supply of 21/ 25 Khz Transmitter coils Assembly Compatible to G.G Tronics Make SSDAC/ HASSDAC Conforming to Spec. No. RDSO/SPN/177/2012 (VER.3) or latest (Clamp Type)
Supply of 21/ 25 Khz Receiver coils Assembly Compatible to G.G Tronics Make SSDAC/ HASSDAC Conforming to Spec. No. RDSO/SPN/177/2012 (VER.3) or latest (Clamp Type)
Modified Rail Base Clamp along with acessories for Fitting Rx/ Tx Coils Conforming to Spec. No. RDSO/SPN/177/2012 (VER.3) of G.G. Tronics Make
Supply of communication card (COM-1/2) suitable for GG tronics make 46 SSDAC/HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012(Ver.3) (Material to be inspected by RDSO) Accepted supply of communication card (COM-1/2) suitable for GGtronics make SSDAC/HASSDAC as per RDSO specification No. RDSO/SPN/177/2012(Ver.3)
Supply of CPU-1 Card suitable for GGTronics make SSDAC/HASSDAC as per RDSO 47 specification No. RDSO/SPN/177/2012(Ver.3) (Material to be inspected by RDSO) Accepted supply of CPU-1 card suitable for GGtronics make HASSDAC as per RDSO specification No. RDSO/SPN/177/2012(Ver.3)
Supply of CPU-2 Card suitable for GGTronics make SSDAC/HASSDAC as per RDSO 48 specification No. RDSO/SPN/177/2012(Ver.3) (Material to be inspected by RDSO) Accepted supply of CPU-2 card suitable for GGtronics make HASSDAC as per RDSO specification No. RDSO/SPN/177/2012(Ver.3)
Supply of Reset box suitable for GGTronics make SSDAC/HASSDAC as per RDSO 49 specification No. RDSO/SPN/177/2012(Ver.3) (Material to be inspected by RDSO) Accepted supply of reset box suitable for GGtronics make SSDAC/HASSDAC as per RDSO specification No. RDSO/SPN/177/2012(Ver.3)
21/23 KHZ TX coils assembly suitable for CEL make HASSDAC as per RDSO specification RDSO/SPN/177/2012 (Ver. 3).
21/23 KHZ RX coils assembly suitable for CEL make HASSDAC as per RDSO specification RDSO/SPN/177/2012 (Ver. 3).
Signal Conditioner Card No. 1 (SCC 1) for HASSDAC (CEL Make). As per RDSO Spec. No. RDSO/SPN/177/2012 Ver 3 or latest. Make/Brand : Central Electronics Limited. Accepted Make : Central Electronics Limited
Signal Conditioning Card No. 2 ( SCC 2) for HASSDAC Make - CEL, as per RDSO Spec. No. RDSO/SPN/177/2012 Ver 3 or latest. Make: Central Electronics Limited Accepted Make : Central Electronics Limited
Reset Box for HASSDAC compatible for CEL make HASSDAC as per RDSO Spn. RDSO/SPN/177/2012 ver 3.0 or latest.
Reset Card for Reset Box compatible for CEL Make HASSDAC as per RDSO Spec. No. RDSO/SPN/177/2012 Ver. 3.0 or latest
Interface Card for Reset Box for HASSDAC Mother Board Compatible for CEL make HASSDAC (Phase Reversal Type )as per RDSO specification No. RDSO/SPN/177/2012 with Version 3 or latest
LCD Display for Reset Box of HASSDAC as per RDSO Specification No.RDSO/SPN/177/ 2012 with version 3 or latest. Make-CEL
Supply of Relay Drive Card for HASSDAC as per RDSO specification no. RDSO/SPN/177/2012 with version 3 or latest Compatible with CEL Make HASSDAC system
Supply of DC-DC convertor Compatible for CEL make SSDAC as per RDSO spc. NO RDSO/SPN/177/2012 ver. 3.0 or latest
Micro Controller Logic Card (MLB-1/MLB-2) for CEL make HASSDAC, as per RDSO specification no. RDSO/SPN/ 177/2012 (Ver.3) or latest, suitable with existing installations of Central Electronics Ltd. make HASSDAC. (MLB-1=50% & MLB2=50% of total Qty.)
Preparation and Supply of Signal Gear Maintenance Record Book as under
Supply of Emery paper No.00
Supply of Petrolium Jelly
Supply of Grease cup for general purpose
Copper lug heavy duty Dowell's make or similar
Supply of Dowells copper tube terminal heavy duty (BS-4579) 25 sq mm, CAT No. CUS-552.
Supply of Dowells copper tube terminal heavy duty (BS-4579) 35 sq mm, CAT No. CUS-554.
Sealing wire used for sealing of signalling relays & equipment.
Supply of seal plier as per sample got approved from site engineer in-charge.
Supply of Sulphuric acid having specific gravity 1.200 to 1.300 for the use in LMLA battery as per requirement of Consignee
Supply of equipment's assisted to work under 25kV RE area. All Insulated tools should 73 be suitable to work in 25kV RE area, tested to 10,000 VAC and rated for 1,000 VAC when working on live parts and should comply NFPA-70E/ ATSM F1505 -01/IEC: 60900-2004 Standard or similar/lates as per technical specifications.
Insulated Open Jaw Spanner Wrench of size- 50mm. Make- Taparia, Stanlay of similar. Fully insulated for safe electrical applications up to 1000V.
Supply of Hydrometer Thimson or similar superior quality.
Ferrule & label printing machine for S &T wiring installation in relay room, location box, point jb, TLJB, etc. -Machine shall be suitable for printing label of different nomenclature for wrapping on core of cable.
Aluminium Foldable Multipurpose Ladders for Maintenace of Signalling Equipments height 12 foot, as per TS
Rechargeable LED Torch Cum Lantern. With following specification 1 LED Torch cum Lantern Wattage-4 W
Rechargeable LED type Head Lamp with belt/ Headband, Lithium Ion Battery, 79 Charger & other accessories. Designed with an ergonomic, adjustable headband.5 Watt or higher for clear visibility in Night. In built battery should be of required capacity to last 8-10 Hrs in one full charge.
Portable drill machine Petrol/Kerosene run, with movable trolley and track drilling stand.(Drilling rail track for bonding), with guarantee and testing certificate as per RDSO specification TM/SM/3 dated 24/09/91 or latest only. Make/Brand - " CREATIVE ENGINEERS"
Drill bit 7.14 mm make JK or superior (Made using High Quality Ultrafine particle 81 Tungsten Carbide raw material having superior bending strength and impact tenacity • Special cutter edge geometry for steel rail ensures the cutting force is small and cutting Speed is fast, resulting in the cutter regaining good strength & sharpness during drilling. Suitable for Model: RATILER Make Broach cutter HSN code84672100)
Pilot Pin - Diameter 6.35mm X Length 77mm Necessary for locating centre punch, opening flow of coolant and ejecting the slug after the drilling is completed
Drill twist bit 9/32'' make JK or superior
Motor(Moped) Trolly (BG) complete with tool box, Umbrella(roof) & other related accessories. This shall confirn to RDSO specification no TM/SM/33. Make/Brand-Kelvin, R.N. ENGINEERING ENTERPRISE or Similar.
Refilling fire extinguisher DCP/CO2 of 4.5KG capacity with new gas and chemical complete in all respect as per extent safety standard.
HONDA EU 30is 3000 VA Portable Inverter Generator(Self Start). Engine type - Honda 86 GX 200T/OHV Single cylinder. Rated power output(VA )- 2800 VA, Fuel Tank capacity - 12.50 Ltrs. Continuous Operating Time -(HRS) - 6.9 Hrs. Dry Weight - 62 Kg. (Dry Weight shouldn't exceed 62KG). Make - Honda, Yamaha, Sri Ram Greaves.
Transportation of S&T material leading up to 1 Km including Loading from Starting point, unloading & Stacking at destination. The work is to be done as per the instructions of Railway Representative at site. Consignee will also provide gate pass / road permit to the transporter.
Extra for each additional 1 Km or part thereof.
Complete painting and varnishing work at a station (3/4 Line). This includes painting of signal posts and fittings, apparatus cases, point machines, junction boxes, rail post etc.This also includes varnishing, letter writing on relays, terminal Nos., apparatus cases, point machine, Signal Nos. and other details as per Signal Engineering Manual and instructions of Engineer at site. The item includes painting of distances of main cable run from G.P nearest to cable run and painting of 89 distances of S&T gears (Singals, Location boxes, point machines etc.) form the railway lines as per SOD and as per instruction of Site Engineer. At least two coats of paint is to be applied besides primary coating of red oxide. This includes supply of paints, varnishes and all other material required for complete painting work at a station. This includes painting on existing functional units also. The painting shall consist of initial red oxide / base paint followed by at least two coat of the paint as per standard painting scheme. This item also includes painting of interlocked gate attached to the station. Location box no. shall be painted on both sides.
Complete painting and varnishing work at a station (5/6 or more Line). This includes painting of signal posts and fittings, apparatus cases, point machines, junction boxes, rail post etc. This also includes varnishing, letter writing on relays, terminal Nos., apparatus cases, point machine, Signal Nos. and other details as per Signal Engineering Manual and instructions of Engineer at site. The item includes painting of distances of main cable run from G.P nearest to cable run and the 90 painting of distances of S&T gears (Singals, Location boxes etc.) form the railway lines as per SOD and as per instruction of Site Engineer. At least two coats of paint is to be applied besides primary coating of red oxide. This includes supply of paints, varnishes and all other material required for complete painting work at a station. This includes painting on existing functional units also. The painting shall consist of initial red oxide / base paint followed by at least two coat of the paint as per standard painting scheme. This item also includes painting of interlocked gate attached to the station. Location box no. shall be painted on both sides.
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of 92 site-in-charge. Epoxy paint will be supplied by Railways. This also includes numbering of signalling gears (Signal posts, Apparatus cases, TLJB, Point Machines, etc. and painting the distance of singalling gears from the railway lines. NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974).
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make.
Item Breakup - A-Outdoor: Supply & Execution
Numbers Total 174775.14 Assembling, erection, installation, taking of cable inside unit through post, termination and wiring of CLS complete with all accessories of CLS unit, post, base, ladder, ladder guards, platform and MS Item- 9 supporting bracket in the middle of the ladder, hoods, pinacles, offset brackets, Junction/stencil type route indicators (if any) - 1 way to 6 way, etc. including fixing & wiring of LED units lamps with contractor's wiring material as per RE requirement. S No. Item Description of Item Unit Qty Rate Amount No
1.00 11887.20 route indicator
On/AG-Sign/A-Sign/Guard Signal Unit Total 73767.65 Supply & fixing of Hylam sheet 10mm thick of various size of minimum grade P2/P3 on apparatuscase/Location boxes for wiring of signaling circuit and cable termination, fixing on suitable size contractors angle with string rod for supporting cable on back side including fixing of Item- 19 all types of terminal /fuse as per location diagram plan and technical specification with drilling of holes on either side of terminals /fusesand other places as required forcable conductor/wires entry and fixing of sheets. S No. Item Description of Item Unit Qty Rate Amount No LUMDING DIVISION-S AND T/N F RLY
Numbers Total 73424.40 Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 Version 1.0 or latest with inter cell connectors, nuts Item- 40 and bolts etc., with hard rubber container, with washer, micro porous vent-cum- sealed float guide etc. S No. Item Description of Item Unit Qty Rate Amount No
Numbers Total 1604392.80 Charging of lead acid cell (Secondary cell) of various capacities as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity Item- 41 acid should be approved type duly inspected by consignee. This includes installation and commissioning of battery in circuit. Battery to be kept on wooden rack. S No. Item Description of Item Unit Qty Rate Amount No
Numbers 180.00 Total 218220.00 Transportation of HDD machine with accessories including handling of stores materials, supply of HDPE/DWC pipe of various sizes as per instruction of Engineer in Charge, preparation of site ,entry and exit pit (1mX1mX1m) and boring for placing of HDPE Silicore duct/DWC of various dia size as per instruction of site engineer for 6Quad Cable/OFC cable/other cables for crossing Item- 68 Track/PuccaRoad/Congested area. Boring trench shall be minimum 3 (three) meter below the river bed/Track and 1(one) meter below the road/pucca road crossing area.Track/Road includes supply of accessories for pulling HDPE pipe. All other petty materials with earthwork, jointing of duct is to be done by Contractor. S No. Item Description of Item Unit Qty Rate Amount No
Metre Total 630880.00
Item Breakup - B-Indoor & Miscellaneous: Supply & Execution
Point Maintenance Record Book. Paper Size A6 Numbers 400.00 (148 x 105 mm) containing Min 50 pages with one cover page, Format to be printed (Portrait) in both sides. Spiral binding with transparent protective cover. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee.
Signal Maintenance Record Book. Paper Size A6 Numbers 400.00 (148 x 105 mm) containing Min 50 pages with one cover page, Format to be printed (Portrait) in both sides. Spiral/suitable binding with protective cover. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee.
Track Circuit Test Record Book. Paper Size A4 Numbers 200.00 (297 x 210 mm) containing Min 50 pages with one cover page, Format to be printed (Landscape) in both sides (LH & RH). Spiral binding with transparent protective cover. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee. LUMDING DIVISION-S AND T/N F RLY
Point Machine history Record Book. Paper Size Numbers A4 (297 x 210 mm) containing Min 50 pages with one cover page, Format to be printed (Landscape) in both sides. Spiral binding with transparent protective cover. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee.
Glued Joint Register. Paper Size A4 (297 x 210 Numbers 120.00 mm) containing Min 50 pages with one cover page, Spiral binding with transparent protective cover. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee.
IPS Battery Record Book. Paper Size A4 (297 x Numbers 210 mm) containing Min 50 pages with one cover page, Format to be printed Landscape) in both sides. Spiral binding with transparent protective cover. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee.
Cable Meggering Record Book. Paper Size A4 Numbers (297 x 210 mm) containing Min 50 pages with one cover page, Format to be printed (Portrait) in both sides. Spiral binding with transparent protective cover. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee.
Printing, Binding & Supply of Disconnection/ Numbers 150.00 Reconnection Memo Book as per IRSEM. Size of Page : A4, GSM: 75 Pages, Each book consists of 100 Pages with letters in Black ink having Green & Red Stripe. It should be binded properly. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee.
Design and supply of Signal Failure Register Numbers (SFR) as per complete breakup :- Summary of Signal Failure- 3 pages, Annexure-B (Signal & Telecom Failure)-80 pages, Annexure-C (Inspection)- 40 pages, History of Interlocking gear- 13 pages, History of Block gear-3 pages, Dates of overhaul and test of Interlocking frame, Key boxes and SM's Slide- 6 pages, Dates of replacement of batteries- 6 pages, Painting of S&T Equipments- 6 pages , Dates of Overhauling/Visual Inspection of various types of relays-6 pages. Paper shall be used of good quality of reputed Make like GSM-80. One sample copy of Signal failure register to be collected from consignee office and designed copy to be approved from consignee before final print.
Printing, binding & supply of Signal Maintenance Numbers 200.00 Record book of Joint point & TC Inspection Register, Size of Page :A4, GSM: 75, Each Book should have 250 Nos of pages (approximate) with both side printing as per new format issued by RDSO. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee.
Printing, binding & supply of Advice of Work Numbers 150.00 memo book. Each book should have 200 pages, serial number on each page should be mentioned, paper size should be Legal. It shall be binded properly with suitable cover. Formate to be collected from the Consignee & to be supplied after approval of sample copy from the Consignee. LUMDING DIVISION-S AND T/N F RLY Total 242445.95 Item- 67 Copper lug heavy duty Dowell's make or similar S No. Item Description of Item Unit Qty Rate Amount No
Numbers 100.00 Total 3835.00 Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. This also includes numbering of signalling gears (Signal Item- 92 posts, Apparatus cases, TLJB, Point Machines, etc. and painting the distance of singalling gears from the railway lines. NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974). S No. Item Description of Item Unit Qty Rate Amount No
524.33 and complete fittings as per NFR standard practice.
25.00 as per NFR Standard Practice.
Machine complete (Point Machine with Black enamel only outside and ground connections with Red Oxide) Total 761730.05 Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside Item- 94 location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. S No. Item Description of Item Unit Qty Rate Amount No
Numbers Total 4643.94
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TENDER DOCUMENT
ATTACHMENT
TenderDocumentSNT-01-26-27-RTBGMBPB.pdf
ATTACHMENT
Download all tender documents and submit your bid