Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.2 LAccepted-AOC | L-1 | Accepted-AOC Bing L-1 | |
| 2 | L-2₹22.4 L+₹1.2 L (5.48%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹22.6 L+₹1.4 L (6.82%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹25.3 L+₹4.1 L (19.2%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L-4 | Rejected-Finance other than L-1 |
Tender Value
₹29.3 L
EMD Value
₹58,680
Closing Date
28 Oct 2021, 6:00 pmClosed
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR MAINT OF HT POLES HT OVERHEAD LINES HT BREAKERS DISTRIBUTION 11KVA AND POWER 33KV TRANSFORMERS AND CONNECTED WORKS AT MPH AREA UNDER GE UTILITY UDHAMPUR
2021_MES_478164_1
CWE/U(U)-59/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
GE U UDHAMPUR
₹58,680
Yes
2 Nov 2021
27 Sept 2021
30 Oct 2021
27 Sept 2021
28 Oct 2021
16 Oct 2021
Amount
Drawing out the SF 6 / RMU from the Circuit system of 11 KV , Servicing the Circuit breaker by checking the following parameters for proper functioning using CTC for clear off the carbon deposited. a) Checking / fault diagonises of Isolator & earth switch mechanism slips b) Checking of Gas inside the tank c) Checking the functionality of relay protection system d) Checking the Mechanism of isolator module and vcb module e) Checking the voltage presence indicator f) Checking the comlete control wiring for tripping/ closing / indication system Necessary spare parts shall be measured as Supply only in following items.The labour charges are deemed to be included in the quoted unit rate for this item. Note : a) Servicing shall be performed by authorised service personnel of OEM i.e M/s ABB b) Servicing certficate shall be provided to engineer-in-charge. c) Replacement of minor spares like Push button lever, Green push button, red push buttons and shaft for operating handles etc. are inclusive of rate quoted by tenderer.
Supply only Spare parts of SF6/RMUs 630 Amperes ( Make of OEM : M/s ABB) :-
3PKE Mechanism without hex rod for isolator module
2 PA Mechanism without hex rod for VCB Module
ASHIDA ADR241S NANO Relay
Voltage Presence Indictor ( Capacitor unit & Chord )
Gas for RMU Tank ( 5 Kg / Can )
CT 200-100/1A 5P10 for protection
CT 200-100/1a, Ci.1 for metering
V module push button bracket
Taking down the VCBs of capacities (630-800 ampers) from the VCB Panel Maintenance and complete overhauling of 11 KV,3 phase, VCB including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 including reassembling, panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components complete, all as specified and directed by Engr-in-Charge. Make of VCB:- Crompton Note:- Spare parts will be measured and paid seperately as supply only under respective items. The labour charges are deemed to be included in the unit rate quoted for this item.
Supply only Spare parts of VCBs ( Make : As Suitability for VCB Crompton Greaves )
Current transformer of capacities 400/200/5/5A
Current transformer of capacities 200/100/5/5A
Circuit Spouts
Bus Spouts
Vacum Interrupters of Make CG model No WL-34599 M3+
Tripping / Closing Coils
M&L for painting to steel tubular swaged pole of Overhead lines (11 Mtr long) complete with and including comprising the following works :- (a) Scraping out wornout old paint and making the surface smooth. (b) Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) as directed by Engr-in-charge. (c ) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engr-in-charge) synthetic enameled paint and marking pole no. with black and white paint complete all as specified.
M&L for ACSR conductor of required size for Over head lines on poles including streching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor all as specified and directed by Engr-in-Charge.
Supply, installation and testing HT gang operated air break switch 11 KV, 3 pole vertically mounted type, mechanically operated, mounted on steel frame with operating mechanism, worked from ground level for current upto 200 Amps with drop out fuse elements of required capacity, GOD/switch having 100 MVA rating at 11 KV and 12 insulators suitable for 11 KV, 50 C/s including mounting on HT poles and necessary electrical connections complete all as specified and directed by Engr-in-Charge.
Supply, installation and testing Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp,11000 Volts complete all as specified.
M&L for cross arms of any sizes with drilled hole (hot and cold etc) in position M.S. work including MS nut and bolts, washers and two coats of aluminium paint over one coat of redoxide primer, all as specified and directed by Engr-in-Charge.
M&L for stay assembly for steel tubular poles comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps bolts, nuts, washers, galvanized steel stay rod 20 mm dia 180 cm long bow 400x14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 90x140mm vitreous, clearance dia of hole 16mm, stayplate of size 230x230x6mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus spoil, upto 50 M all as specified and shown in plate No 1 of MES SSR Pt -I, complete all as specified and directed by Engr-in-Charge.
Dehydration and filteration of existing serviceable transformer oil at site or at factory permisses of any type,any capacity,any rating transformers till it achieves the required dielectric strength upto 50 KV at 2.5mm gap using dehydration plant complete, all as specified and directed by Engr-in-Charge. Note: Mobile filtration machine has to be brought at site for dehydration alongwith hose pipe/ cable, necessary T&P shall be provided by contractor.
Topping up of transformer oil of good quality having not less than 50 KV dielectric strength,flash point not less than 135 degree C, having low viscosity for filing complete, all as specified and directed by Engr-in-Charge. Make: Savita/Power oil/Servo oil as per IS 335 of 1983 all as specified. Note: Draining out old unserviceable oil & filling process is deemed to be included in quoted rate in respsctive item.
Taking proper shut down in writing and disconnecting the LT and HT electric mains from transformer of capacity 63 KVA to 500 KVA, removing the lid/cover for inspection to facilitate minor repairs at site , replacement of HV/LV bushings of aluminium of required current rating , draining out the transformer oil reassembling the transformer, refilling the transformer oil (new or old) installing, commissioning and testing at site complete, all as specified and directed by Engr-in-Charge.
Shifting of transformer of capaicites (63KVA-500KVA) from the Premises of ( MPH Premises) to workshop for necessary repairs. Reshifting the transformer Post repairs from workshop to MPH (Premises) with help of hydra/crane/any other lifting devices . Note: Transformer rewinding shall be done at authorized workshop by Sstate Electrical Board or OEM.
M&L for rewinding of HT/LT coil conforming to the original winding of the transformer of any make/capacity with super enamelled cooper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete, all as specified and directed by Engr-in-Charge.
Taking down the old corroded / damaged HT Poles from site including supply and fixing Steel tubular swaged pole erected to truly vertical or planted as strut complete with 6 mm thick MS Base plate,welded to pole,finial taper cap, bolts, nuts, screws,11 Mtr long, type 410 SP - 55,including drilling of holes of required size for fixing of cross arms,painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the portion embedded in concrete, and marking pole no. with black paint at suitable height all as specified and directed by Engineer-in-Charge.Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’
Plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete, all as specified and directed by Engr-in-Charge.
Plain cement concrete 1:2:4 type B-1(using 20 mm graded stone aggregate) for coping of poles complete including necessary form work, all as specified and directed by Engr-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete, all as specified and directed by Engr-in-Charge.
Description all as per Srl item No 19 above but size of cable 120 to 185 sqmm.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for heat shrinkable straight through joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete, all as specified and directed by Engr-in-Charge.
Description all as per Srl item No 21 above but size of cable 120 to 185 sqmm.
Taking down the unserviceable / moistured HT Cable from the under ground system. Supply , lay test and commissiong of HT Cable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor , 11000 volts earthed grade cross sectional area as illustrated below:-
a) 120sq.mm, 3 core
b) 150sq.mm, 3 core
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Description all as per Srl item No. 24 here in before but depth exceeding 1.5m but not exceeding 3m complete all as specified & directed by Engineer-in-charge.
Returning filling in (soil) including spreading leveling watering and well ramming in layers not exceeding 25cm thick, all as specified.
Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified.
Supply and lay DWC Pipe ( Double wall corruguated) confirming to IS: 14930(Part-II) along with necessary Snap fit Coupler for interconnection Suitable for HT Cable of size 300/240 sq.mm (90X 76 mm as diameter) all as specified & directed by Engineer in charge.
Supply and lay DWC Pipe ( Double wall corruguated) confirming to IS: 14930(Part-II) along with necessary Snap fit Coupler for interconnection Suitable for HT Cable of size 185/120sq.mm (77X63 mm as diameter) all as specified & directed by Engineer in charge.
Taking down the unserviceable rubber mats from the substation . Supply and laying synthetic rubber insulated mats 2.5 mm thick for voltage up to 11kv electrical purpose as per IS 15652-2006 suitable for electric shock safety of sizes 2 x1 m, complete all as specified and as directed by Engineer in charge.
M&L for replacement of earthing with Copper earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the earth plate not less than 1.5 M below ground level connected to Copper strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR-2009 part 1, including necessary excavation and earth work in any type of soil, comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh, PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note: - (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
vijay kumar gupta and co
MOHAN LAL AND SONS
FANGALIA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .