Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹20.2 L+₹5.8 L (39.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹23.5 L+₹9.0 L (62.0%)Rejected-Finance FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L3 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
7 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
REPAIR/ MAINT OF SUBSTATION EQPTS PANELS AND REPAIR AND MAINT OF VACCUM CIRCUIT BREAKERS, RELAYS, MEASURING METERS, PREVENTING ROUTINE MAINT OF CAPACITOR BANK APFC PANELS ELECTRIC SUPPLY INSTALLATION AT COD CHHEOKI UNDER GE (WEST) PRAYAGRAJ.
2023_MES_622484_1
81778/W/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (West) Prayagraj
₹50,000
Yes
5 Jan 2024
10 Oct 2023
14 Nov 2023
11 Oct 2023
7 Nov 2023
24 Oct 2023
Amount
M&L for inspection/servicing /testing two time in contract period by HT expert of 03 Nos. SF 6 Breaker/VCB of line circuit breaker, control panel including CT, PT and relays in control panel of Indoor type SF 6 Gas Circuit Breaker/VCB of capacity upto 800 Amps and rating 36 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. (iv) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (v) Check for rust and wear. (vi) Checking of spring charge mechanism (vii) Visual check for rust and deformation. (viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (ix) Check for loosened connections, rust, damaged lead wires. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Replacement of Dashpot/shock absorbers . (xiii) Replacement of carbon brush of spring charging motor (xiv) Cleaning of porcelain bushing (xv) Checking of limit switch
(b) The following test shall be carried out:- (i) Primary Injection Test of outdoor CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay (ii) Line diffrential relay. (d) Testing of followig Aux relay:- (i) DC Supply supervision relay. (ii) Trip Circuit suprvision relay (ii) SF 6 gas pressure low. (iii) PT Fuse failure relay (iv) Master trip relay (v) Under voltage relay (vi) Over voltage relay Note:- (i) Test report shall be laminated to control panel of respective breaker. (ii) The wk shall be carried out from auth Rep/ Engineer of CG/ABB. (iii) Caliberation of relays to be done from qulified engineer of CG/ABB. (iv) The parts shall be replace under relevant item of supply only.
S&F bushbar spout for crompton make trolly mechanism 11 KV VCB, complete all as specified and directed.
S&F charging gear for crompton make trolly mechanism 11 KV VCB, complete all as specified and directed.
S&F operating mechanism for breaker 11 KV VCB complete all as specified and directed.
S&F teflon hexagonal interlocking bush complete interlocking with strip complete all as specified and directed.
S&F on Push button complete all as specified and directed.
S&F OFF push button complete all as specified and directed.
S&F ON/OFF Indicator complete all as specified and directed.
S&F OFF load isolator with earth switch mechanism complete all as specified and directed.
S&F Z type lever of OFF push button complete all as specified and directed.
S&F Z type lever of ON push button complete all as specified and directed.
S&F trip coil only Y1 control volt 24 VDC complete all as specified and directed.
S&F close coil only Y2 control volt 24 VDC complete all as specified and directed.
S&F spring charging motor with gear 24 VDC complete all as specified and directed.
S&F standerd spring charging motorised kit for V module complete all as specified and directed.
S&F bus bar bottle of vaccum circuit breaker complete all as specified and directed.
M&L (in replacement) Current transformer, indoor comprising of 3 Nos single phase resin cast CTs of 300-150/5+5 amps ratio, PS class, with suitable VA burden and accuracy suitable for protection & metering of 11 KV VCB panel complete all as specified and directed.
M&L (in replacement) PT : three Nos single phase potential transformer of ratio 11 KV/110 volts, class 1, suitable for VA bourden mounted on extended frame of VCB including mounting structure complete all as specified and directed. Note : (i) All the instruments, primary and secondary injection kit and T&P required for the above job shall be arranged by the contractor at site and cost of the deemed to be included in the above rate. (ii) The above checking, inspection, installation and testing work shall be performed by HT expert/Engineer.
S&F (in replacemement) ACB 4 pole of size 630 Amp , in the existin out door/indoor LT panels and connetion with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed. Make of ACB: Schneider/L&T/ABB/Havells.
Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as directed for following size :- Note :-Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately.
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
185 Sqmm 3.5 core.
240 Sqmm 3.5 core.
400 Sqmm 3.5 core.
Excavation in trenches in soft/ loose soil n.exc 1.5 m wide and n.exc. 1.5 mtr deep and getting out and laying LT UG Cable complete all as specified and directed .
Returning filling in with the soil obtained from item above here-in-before includiing spreading , leveling and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc.1.5 mtr above starting point complete all as specified and directed
Supply and laying sub class 'B' brick old size laid flat in trenches across the length for protection of cable as cable cover complete all as specified and directed .
M&L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed.
M&L for boring under road horizontely of size 40/50 mm bore using GI pipe for passing of cable in road/path in hard/soft/ loose soil complete all as specified and directed.
M&L (in replacement) for GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete for following sizes :-
50 mm bore.
80 mm bore.
Dismantling & taking out defective LT PVC/XLPE cable from trenches with cutting and removing defective parts and supply & making cable joint using straight through joint heat shrink type ad making connection of LT cables, megering & re-storation of electric supply complete including jointing material for the following sizes of cable :- Joint make - Reychem
25 Sqmm 3.5 core to 70 Sqmm, 3.5 core.
95 Sqmm 3.5 core to 240 Sqmm, 3.5 core.
S&F (in replacemement) following items in the existin out door/indoor LT panels and connetion with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below :-
MCCB 4 pole 100 amps rating, 16 KA breaking capacity, with separator at both side.
MCCB 4 pole 150/160 amps rating, 36 KA breaking capacity, with separator at both side.
MCCB 4 pole 200 amps rating, 36 KA breaking capacity, with separator at both side.
MCCB 4 pole 250 amps rating, 36 KA breaking capacity with spreader at both side.
MCCB 4 pole 400 amps rating, 36 KA breaking capacity with spreader at bothe side.
S&F ( in replacement ), connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 900x600x500mm and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :-
(a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 400 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. , (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase : L&T/Seimens (d) Replacement of volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B . (e) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete. (f) MCCB 4 Pole 250 Amp 415 volt thermal adjustable ,type with 25 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos.
M&L for checking all connections and Mechanism, cleaning, servicing, overhauling, testing complete and repair for at automatic power factor correction panel (APFC) upto 35/50/70/200 KVAR by taking out 4mv heavy duty capacitor banks of existing rating/Size/Steppings 3 Phase 415 suitable for having losses not less than 0.5 w/KVAR with discharge registors. Including Replacement of minor/major parts if required for smooth functioning complete all as specified & directed by Engineer-in-charge. Note:- (i) Cost of major/minor parts required for replacement shall be measured and paid separately as supply only . (ii) All the instruments and T&P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (iii) The all above checking, inspection, installation & testing work shall be performed by authrised manufacturer or expert electrical Engineer of company.
S&F capacitor 5 KVAR capacity complete all as specified and directed.
S&F capacitor 7.5 KVAR capacity complete all as specified and directed.
S&F capacitor 10 KVAR capacity complete all as specified and directed.
S&F capacitor 12.5 KVAR capacity.
S&F capacitor 15 KVAR capacity complete all as specified and directed.
S&F capacitor 20 KVAR capacity complete all as specified and directed.
S&F capacitor 25 KVAR capacity complete all as specified and directed.
S&F capacitor 50 KVAR capacity complete all as specified and directed.
S&F MCCB TPN 160 Amp, 25 KA capacity complete all as specified and directed.
S&F MCCB TPN 200 Amp, 25 KA capacity complete all as specified and directed.
S&F MCCB TPN 250 Amp, 25 KA capacity complete all as specified and directed.
S&F LED phase indicator lamp complete all as specified and directed.
S&F contactor having current lighting resistors suitable for capacitor Switching off variable KVAR correctiong of specification as approved.
S&F Varlogic APFC Relays of existing size/capacity step of five complete all as specified and directed.
S&F Rotary Switch 5KVAR to 10 KVAR complete all as specified and directed.
S&F Rotary Switch 12.5KVAR to 20 KVAR complete all as specified and directed.
S&F High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 150/250/400 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve complete all as specified and directed.
S&F (in replacemement) of onload /offload Changeover rotary handle type in the existing out door/indoor LT panels/wall and connetion with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door/wall using cutting/ chasing as required for proper fixing & connection complete all as specified and directed by Engineer-in-Charge. Make:-Havells/L&T/C&S/Sneider)
On Load Change over switch of 200 Amp, 4 Pole.
On Load Change over switch of 300/320 Amp, 4 Pole.
On Load Change over switch of 400 Amp, 4 Pole.
On Load Change over switch of 600 Amp, 4 Pole.
Off Load Change over switch of 200 Amp, 4 Pole.
Off Load Change over switch of 400 Amp, 4 Pole.
Supply, fixing ,commissioning and testing of outdoor type automatic power factor correction (APFC) panel for 3 phase ,415 Volt & 50Hz system of capacity 100KVAR with including foundation of panel ,voltmeter , ammeter and indicator complete all as specified and directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel pipe electrode,40mm bore ,medium grade ,2.5 metres length buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 32x6mm dia galvanised iron or steel wire all as shown in complete all as specified and indicated including testing on completion
M&L for spreading and levelling evenly (any thickness) hard core using 40mm graded stone aggregate at sub-station complete all as specified and directed.
Titco Electricals
RAMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .