Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹37.4 L+₹5.6 L (17.7%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹37.2 L+₹5.4 L (17.0%)Rejected-Finance SUMATEE BHAWAN GUWAHATI AIRPORT NEAR BORJHAR TELEPHONE EXCHANGE GUWAHATI 781015 ASSAM | KAMRUP METRO | ASSAM | 781015 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
23 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
Provn of store room for storage of New weapons in STN Armoury at 19 Wing and certain Minor Work at 14 BRD under GE (AF) Borjhar
2023_MES_581662_1
8336/BOR/E8
Open Tender
Civil Works
Item Rate
240 days
GE (AF) Borjhar
MES Contractor enlisted as Class D category a(i) and b(i) having deposited Standing Security of Rs 100000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹68,000
Yes
11 Aug 2023
17 Feb 2023
25 Mar 2023
17 Feb 2023
23 Mar 2023
4 Mar 2023
Amount
SCHEDULE 'A'/BOQ OF B/R-I
Surface dressing not exe. 15 cm deep in soft/loose soil complete all as specified and as directed..
Excavating over areas not exe 1.50m deep and getting out in soft/ loose soil complete all as specified and as directed.
Add additional 1.5m or part thereof in depth beyond the first 1.5m but not exe 3.00m complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation as lean concrete for column footings, foundation below brick walls, etc. complete all as specified and as directed.
M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in Column footing, plinth beam, etc. complete all as specified and as directed.
M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in Column above footing up to bottom of roof beam complete all as specified and as directed..
M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in roof slab supported on beams, walls, etc. complete all as specified and as directed..
M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in roof beam complete all as specified and as directed.
M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in lintel beam complete all as specified and as directed.
M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in chajja complete all as specified and as directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, columns up to PB and plinth beams; and similar work; vertical or flat rough finished surfaces of concreate complete all as specified and as directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns, etc. rough finished surface complete all as specified and as directed.
M&L for formwork to sides and soffits of lintel beam etc, rough finished surface complete all as specified and as directed.
M&L for formwork to sides and soffit of chajja, etc. rough finished surface complete all as specified and as directed..
M&L for formwork to sides and soffit of roofs, floor beams, etc rough finished flat concrete surface complete all as specified and as directed..
M&L for formwork to sides and soffits of roofs, floor slabs, etc., finished surface not exc 200mm thick rough finished flat surface of concrete complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per Serial item No. 18 here-in-before but 8 mm to 10 mm dia.
All as per Serial item 18 here-in-before but 8mm dia and over upto and including 10mm dia as in stirrups, binders, etc.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm each layer complete all as specified and as directed.
M&L for removing excavated materials n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed
M&L for brick work with sub class 'B' bricks using old size bricks, exe 6m mean radious, built in cement mortar (1:6) complete all as specified and as directed.
Forming embankments including raising (or lowering) earth, spreading in layers n. exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and as directed.
Sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for PCC (1:5:10) type E-2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and as directed.
M&L for polythene film, 150 micron thick, laid on floor complete all as specified and as directed.
M&L for rendering 15mm thick on other fair faces of brick work surfaces in cement mortar (1:6) as in internal plastering, finished even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work surfaces as in external plastering in two layers consisting 10mm thick in cement mortar (1:6) and top layer 5mm thick in cement mortar (1:4) with WPC @ 3% of cement by weight of cement or as per manufacturer's instructions, finished fair and even without using extra cement complete all as specified and as directed. Note : WPC shall measured and paid separately.
M&L for rendering 5mm thick on soffit of RCC ceiling and chajja surfaces in cement mortar (1:3), finished even and fair without using extra cement complete all as specified and as directed.
M&L for preparing the new plasterd surfaces of ceiling and applying three coats of white washing complete all as specified and as directed.
Supply only Integral water proofing compound, as per latest specification complete all as specified and as directed.
M&L for preparing the new plasterd surfaces of external walls and applying two coats of exterior emulsion paint over and including one coat of primer (Camoflauge pattern) complete all as specified and as directed.
M&L for preparing the new plasterd surfaces of Internal walls and applying two coats of oil bound distempering over and including one coat of primer complete all as specified and as directed.
M&L for 40mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in sub base floor to receive tiling, etc. complete all as specified and as directed..
M&L for 15mm thick screed bed or bedding in cement mortar (1:6) for laying floor finishes complete all as specified and as directed.
M&L for 10mm thick plastering in cement mortar (1:4) for laying floor finishes as on vertical surfaces, such as dado, skirting, etc. complete all as specified and as directed.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
All as per Serial item No. 38 here-in-before but as on vertical surface of skirting,
M & L for rendering 10 mm thick on top of RCC roof surfaces in CM(1:4) , & applying 3 mm thick APP felt incl priming surfaces with bituminus primer @ 0.40 KG/SQM complete all as specified and as directed.
S & F for Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed. (Profile size 125 x 60 mm) complete all as specified and as directed.
S&F for 35mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides and fitted to chowkhats complete all as specified and as directed.
S & F for 2nd class hard wood plain ,soild straight chowkats and frames of wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed..
S&F Glazed and skelton window, Ventilator shutters, 30mm thick of Second class hard wood open rebated and prepared to receive glass, gauge etc divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a) complete all as specified and as directed.
S & F for MS cold rolled butt hinges of size 75 mm complete all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed length of bolt 250 mm complete all as specified and as directed.
S&F for aluminium handle, cast type anodized size of handle 125 mm complete all as specified and as directed.
S&F for aluminium handle, cast type anodized size of handle 100 mm complete all as specified and as directed.
S & F for aluminium anodized, barrel tower bolt of extruded section, length of bolt 200 mm complete all as specified and as directed.
S & F for Aluminium anodized, barrel tower bolt of extruded section, length of bolt 150 mm complete all as specified and as directed.
M & L for sheet glass panes 3 mm thick area of each pane not exe 0.50 SQM with balck tint. Fixed to aluminium Door/ Window complete all as specified and as directed.
M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; ramework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Material and labour for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed.
M & L for Preparation of new or untreated painted wood and wooden based surfaces of any description not other wise described over 10 centimetre width or girth and applying Two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M & L for hard core of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface as in plinth protection, Path etc complete all as specified and as directed.
M & L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in Plinth protection.Path etc, 75 mm thick finished even & smooth without using extra cement etc complete all as specified and as directed.
Material and labour for providing Plain Cement Concrete (1:3:6) type C1 using 20mm graded aggregate as in surface channel and drain all as specified and directed.
M & L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etccomplete all as specified and as directed.
SCHEDULE 'A'/BOQ OF E/M WORKS
Material and labour for flame proof point wiring on wall and surface wiring on ceiling/ roof with necessary fixing arrangements for one light/fan point controlled by one switch with stranded PVC, FRLS insulated and unsheathed copper stranded conductor of size 1.5 sqmm, 1100 volts grade drawn in and including 14 gauge ERW rigid steel conduit (metallic) not less than 20 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc., including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 sqmm, 1100 volts grade for continuous earthing complete all as directed.
Supply and fix in repair flame proof rotary switch in ML6, 10/16 amps, single pole, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit duly approved by CMRI dhanbad and as manufacturers intructions including taking down old flame proof rotary switch with enclosure complete all as directed.
Supply and fixing LED Flame proof tube light fitting 20 w connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed..
Supply and fixing Modular VTPN Distribution Board Thermoplastic Polycarbonate Thermoplastic double door type Opaque/Transparent Vertical Three Phase and Neutral Distribution Board according to IEC 61439-3 for Commercial and Industrial Buildings which is suitable upto 250A 690V a.c., IP-66 according to IEC60529 extended type , weather proof, rust proof, UV resistance, halogen free, silica free, corrosion proof; protection class I - earthed ,totally insulated, having internally embedded gasket with provision for cable entry through glands/grommets/ flanges, flame retardant, self-extinguishing with glow wire test at 960C according to IEC 60 695-2-11,ULSubject 94,V-2;chemical resistance towards acid, lye, benzene and mineral oil; Impact strength IK 08( 5 Joule) in accordance with DIN EN 50102, Colour :Grey, RAL 7035
Supply and fixing MCCB 3 Pole .415 V. fixed type, 25 to 100 Amps with breaking capacity 16 KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing SP 6 to 32 AMP amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Earthing complete with galvanised steel pipe electrod, 40 mm bore, medium grade, 2.5 meters length, burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.25 meter below ground level, connected to galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 2 of SSR Part-I 1991 connected to earthing main DB's/ Panels all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1 and CI pit cover with frame duly grouted in the PCC chamber. Charcol, salt including provision of earth lead protected by 15mm dia light grade GI pipe and funnel with wire mess, 20mm dia medium grade GI Pipe for watering complete as specified and directed including testing on completion.
M&L, connecting of 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 Sqmm nominal cross section 4 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers testing and commissioning complete all as specified including taking out existing unserviceable cable from trenches, floor, ducts, poles or roads complete all as directed (Earth work shall be measured and paid separately above mentioned BOQ item No 03).
M&L dry Sand cushioning to underground electric cable 8cm below and 15 cm above the cable all as specified in clause 19.75 of SSR Part-I Note:- (i) Sand shall be fine sand as specfied in clause 14.5 of SSR Part-I. (ii) Punned thickness shall be measured.
M&L Bricks laid in trenches flat with width equal to length of bricks for cble protection with well burnt sub class B bricks complete all as specified.
Supply and fix copper strip 20 x 3 mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified.
Supply and fix single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified.
Test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified.
M & L for earthing complete with copper plate electrode 600x600x3.15 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to copper strip 20x3mm dia by means of brass nut, bolts, check nut , bolt, washer & protection pipe for earth wire from the earthing plate to the DB/main switch/panel,(40mm bore, light grade,) watering pipe from plate to earthing pit (20mm bore, medium grade) funnel wire mesh. The earthing pit made up of PCC 1:3:6 type CI and pit cover made up of 40 mm thik precast RCC 1:2:4 type BI reinforced with 6 mm dia TMT rod and suitable handle of 8 mm dia TMT rod incl necessary earth work as shown in SSR Part-I plate no.5 as specified and directed. Note;- i) The copper strip and protection pipe beyond 7.5 Mtr length shall be measured and paid separately. However earthwork for the same is deemed to be included in this rate . ii) The desired value of earth resistance is less than 5 Ohm on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost, otherwise it will not be measued and paid to the contractor . iii) Form work of size .9mx.9mx.6m for pouring charcoal and salt is deemed to be included in this rates . v) During earth work if surface water found at site , the cost for dewatering through pumpset is deemed to be included in this rate.
M & L Point wiring with 1.5 Sqmm PVC insulated and unsheatheed single core multi stranded copper conductor ISI marked 1100 volts grade drawn in ms conduits & accessories on walls/roofs ceiling for fixing of switches/sockets etc including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable for earth continuity and connecting to commom earth dolly complete all as specified and directed :- (a) One Light /fan point controlled by one switch
Supply and fixing flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed
S&F Flameproof ON-OFF button with switch for light/fan point complete all as specified and directed.
Material & labour for Sub main wiring with two runs of single core 4 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh and including MS conduit of adequate size with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 4 Sqmm as earth wire (green in colour) run through pvc conduit and connected common earth dolly including taking out the old sub main wiring shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed.
S&F Fan regulator for Flame proof Ceiling fan of 1200 mm sweep size complete all as specified and directed.
S&F FLP-WP Rotary switch with cable termination box in LM6 for 16A,single pole ON-OFF complete all as specified and directed.
S&F FLP-WP DOL starter in LM6 with isolator for capacity 5 HP complete all as specified and directed..
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size as directed.
Supply and fix in repairs of MCB SPN DB 4 way double door, glazed type, IP 43 protection,Glazed door, isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09, complete all as specified and directed.
S&F Flameproof-Weatherproof ceiling fans single phase in cast aluminium LM6 of sweep size 1200 mm complete all as specified and directed.
S & F flame proof Exhaust fan of confiming to IS 65 Single phase of sweep size 300mm including suitable louvers running at 1440 RPM and minimum CFM 1120 complete all as specified and directed.
Supply & fix in repair of MCBs single pole (SPN) 6 to 32 Amps with 10 KA breaking capacity of 'C' Curve in distribution boards confirming to IS/IEC 60898-1 (ISI merked) complete all as specified and directed.
Ms Sukumar Talukdar and Co.
M/s Rawat Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .