| 1 | L-1₹19.3 LAccepted-AOC SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L-1 | Accepted-AOC M/s Bharti Enterprises is lowest and accepted | |
| 2 | L-2₹20.7 L+₹1.4 L (7.05%)Rejected-Finance 02 RUDIA BIT MESRA ROAD NEORI VIKAS RANCHI JHARKHAND 835217 | RANCHI | JHARKHAND | 835217 | L-2 | Rejected-Finance Not lowest | |
| 3 | L-3₹20.9 L+₹1.6 L (8.35%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L-3 | Rejected-Finance Not lowest | |
| 4 | L-4₹21.2 L+₹1.9 L (9.80%)Rejected-Finance B 1203 VRINDA RESIDENCY BARIATU ROAD RANCHI JHARKHAND 834009 | RANCHI | RANCHI | JHARKHAND | 834009 | L-4 | Rejected-Finance Not lowest | |
| 5 | L-5₹21.3 L+₹1.9 L (10.1%)Rejected-Finance | L-5 | Rejected-Finance Not lowest |
| Sl No | Description | Qty | Unit | arics infrastructure L4 | Raj Construction L3 | BHARATI ENTERPRISES L1 | MONA GENERATOR SEVICES PVT. LTD. L6 | THE SUVASH AND SONS L2 | M/S RANKWAR CONSTRUCTION L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply installation commissioning & testing of Diesel Engine Generating sets 415 volts 125 KVA or nearest higher rating 3 -phase 0.8 power factor 50 Hz, 1500 RPM,Governing class (as per ISO 8528 Part-V) -G3 , CPCB IV+ Gensets with AMF panel incl self exicited self regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Ranchi and confirming to condition under IS 10002,ISO-3046,BS-5514 with following:
(i) DG set shall be Environment Friendly and designed to meet CPCB IV+ norms. It confirms to latest global pollution standards.The capacity of Generator set shall be net after all due derating factors as per relevant ISI design. (ii) Rate quoted shall be deemed to be inclusive of cable and terminations from Generator panel to change over switch including making necessary holes to wall and making good to disturbed surfaces of match to original specification and connection up all as directed.(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.(iv) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of one hour on 10% overhead in presence of representative detailed by accepting Officer, all arrangements shall be made by the contractor for tests at his own cost. (v) Rate of DG set deemed to be included servicing cost, engine oil, air filter,diesel filter and any damaged spare parts cost of DG set upto 2 years from date of completion.. | 1 | Each | 17,00,000 ₹17,00,000 | 16,50,000 ₹16,50,000 | 13,80,000 ₹13,80,000 Lowest | 18,12,281 ₹18,12,281 | 14,75,000 ₹14,75,000 | 15,05,000 ₹15,05,000 |
| 1.10(A). Alternator :- Standard design alternator rated at 125 KVA or higher rating net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of ± 1% at rated voltage from no load to full load. The alternator shall be confirming to BSEN 60034-1 &IS- 4722 and shall be inposition to generate supply with frequecy regulation with in ± 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. (i) Insualation class - 'H' with Efficiency (at 100% load ) with 0.8 PF shall be minimum 91.9%. (ii) Temparature rise Class - 'H' (iii) Excitation : Self Excited (iv) Regulation performance: The voltage is kept constant with ± 1%, manual voltage adjustment within ± 5% . (v) Frequency regulation ±1% | |||||||||
| 1.20(B) Diesel Engine: - Adequate capacity of Diesel engine not less than 156 BHP (Minimum), 04 cylinder , Cubic capacity 4.32 Ltrs based on manufacturers technical details water cooled to drive independently the alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- (i) Fly wheel with housing (ii) Cooling system :- Mounted radiator with fan & belts. (iii) Cooling Water pump : - Centrifugal type belt driven. (iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacturer recommendation & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre. (v)Exhaust gas turbo charger type (vi)Exhaust manifold Silecer : Residual type Bellows | |||||||||
| 1.30c) Annunciation with indication lamps for : (i) Low lub oil pressure.(ii) High Water Temparature.(iii) Engine over speed.(iv) Battery low voltage. Controls :- (a) Load on Indication (b) Load off indication (c) Engine start push button (d) Engine stop push button (e) Fault accept / reset push button (v) Battery Charger incorporated with : (a) Transformer (b) Rectifier (c) Restance (d) DC Volt meter, (e) DC Ammeter (vi)Protection :- (a) Over current relay - 01 No | |||||||||
| 1.40(G) Approved designed to meet CPCB IV+ norms:- (i) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(ii) The generating set batteries and fuel tank should be housed inside the acoustic enclosure. (iiii) Fuel tank should be located inside the acoustic (iv) Construction Details/specification are as follows : - a) Outer body :- CRCA Sheet of 3.15mm thick. b) Doors :- CRCA sheet of 3.15 mm thick c) Sound Insulation :- 100 mm thick rock wool (64kg/Cum) v) The accoustic should be composite in construction and fully assembled integral unit. vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable inlsulated plat form. vii) The DG Set should be provided with external Emergency stop push button. viii) The enclosure should be provided with bulk head light fitting for inside illumination (ix) The noise level should be 75 db at 1m under free field conditions. x) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade and base frame as per manufacturer recommendation | |||||||||
| 2.00 | Fabricate supply install test and commissioning of kiosk box/LT panel out door type totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet including powder coated paint finish including all accessories, provision independent removevable MS plates for fixing cable glands for all incomming and out going cables,control wiring with 2.5 sqmm copper conductor and dismantling old feeder pillar box with cable and reconnecting Existing cables any type any size complete incuding necessary PCC foundation complete all specified. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (2) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work.
(a) Main incoming 315 Amps MCCB 04 pole, 25 KA - 01 nos
(b) Outgoing 200 Amps MCCB 3 pole, 16 KA - 01 nos
(b) Outgoing 63 Amps MCCB 3 pole, 16 KA - 01 nos
(c) 10 Amps MCB SPN pole, 10 KA - 01 nos
(e) On load change over switch 415 V in sheet metal enclosure four pole of capacity 250 amp - 01 Nos
(f) Electrolytic grade aluminium bus bar 400 rating for 3 phase and neutral including PVC colour coded sleves. - 01 Set
(g) LED lamps for R,Y,B Phase indication with control fuse/MCB - 01Set
(h ) Multi function meter digital type with selector switch - 01 set
(k) Insulators, wiring, bus bar sleeves, lugs, gland, sheet metal enclosure etc including complete wiring with suitable size of copper wire
(f) Panel wiring with PVC insulated single core 2.50 sqmm copper conductor. | 1 | Each Job | 90,000 ₹90,000 | 86,000 ₹86,000 Lowest | 1,62,000 ₹1,62,000 | 1,50,517 ₹1,50,517 | 1,55,000 ₹1,55,000 | 1,42,000 ₹1,42,000 |
| 3.00 | M&L for XLPE insulated heavy duty electric cable and LT cable of size 120 Sqmm 3 ½ core with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall (including PVC conduit in suitable size and clamp) /pole and including taking down old unserviceable cable complete all as specified and directed of following sizes Note:- (i) Excavation & earth work, new sand, new bricks for cable protection shall be measured & paid seperatly in respective items here- in- before. | 132 | RM | 816 ₹1,07,712 | 925 ₹1,22,100 | 850 ₹1,12,200 | 799 ₹1,05,468 Lowest | 1,050 ₹1,38,600 | 810 ₹1,06,920 |
| 4.00 | All as per item No 3 but size of LT cable 70 Sqmm 3 ½ core complete all as specified. | 82 | RM | 499 ₹40,918 Lowest | 585 ₹47,970 | 600 ₹49,200 | 517 ₹42,394 | 680 ₹55,760 | 533 ₹43,706 |
| 5.00 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft /loose soil all as directed.Note - Excavation/earth work shall be done by manually manner with the safety of Data/OFC/telephone cable. If any cable damaged during the excavation to be repair same time and cost to be included in qouted rates. | 46 | CUM | 150 ₹6,900 Lowest | 160 ₹7,360 | 300 ₹13,800 | 192 ₹8,832 | 180 ₹8,280 | 450 ₹20,700 |
| 6.00 | Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25cm all as directed. | 30 | CUM | 50 ₹1,500 Lowest | 90 ₹2,700 | 120 ₹3,600 | 83 ₹2,490 | 80 ₹2,400 | 200 ₹6,000 |
Tender Value
₹23.7 L
EMD Value
₹47,400
Closing Date
26 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Ranchi
Commander Works Engineers Ranchi Military Engineer Services Dipatoli Mil Station Hotwar, Ranchi-834009
PROVN OF STANDBY POWER SUPPLY AND CONNECTED ITEMS FOR NFS AT 124 INF BDE SIG COY AT NAMKUM POCKET UNDER GE RANCHI
2025_MES_717335_1
80599/1629/E8
Open Tender
Electrical and Maintenance Works
Item Wise
120 days
GE Ranchi
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GE Ranchi
₹47,400
HQ CWE Ranchi
28 Aug 2025
28 Jun 2025
2 Aug 2025
28 Jun 2025
26 Jul 2025
12 Jul 2025
28 Jun 2025 - 5 Jul 2025
5 Jul 2025
Amount
Supply installation commissioning & testing of Diesel Engine Generating sets 415 volts 125 KVA or nearest higher rating 3 -phase 0.8 power factor 50 Hz, 1500 RPM,Governing class (as per ISO 8528 Part-V) -G3 , CPCB IV+ Gensets with AMF panel incl self exicited self regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Ranchi and confirming to condition under IS 10002,ISO-3046,BS-5514 with following: (i) DG set shall be Environment Friendly and designed to meet CPCB IV+ norms. It confirms to latest global pollution standards.The capacity of Generator set shall be net after all due derating factors as per relevant ISI design. (ii) Rate quoted shall be deemed to be inclusive of cable and terminations from Generator panel to change over switch including making necessary holes to wall and making good to disturbed surfaces of match to original specification and connection up all as directed.(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.(iv) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of one hour on 10% overhead in presence of representative detailed by accepting Officer, all arrangements shall be made by the contractor for tests at his own cost. (v) Rate of DG set deemed to be included servicing cost, engine oil, air filter,diesel filter and any damaged spare parts cost of DG set upto 2 years from date of completion..
(A). Alternator :- Standard design alternator rated at 125 KVA or higher rating net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of ± 1% at rated voltage from no load to full load. The alternator shall be confirming to BSEN 60034-1 &IS- 4722 and shall be inposition to generate supply with frequecy regulation with in ± 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. (i) Insualation class - 'H' with Efficiency (at 100% load ) with 0.8 PF shall be minimum 91.9%. (ii) Temparature rise Class - 'H' (iii) Excitation : Self Excited (iv) Regulation performance: The voltage is kept constant with ± 1%, manual voltage adjustment within ± 5% . (v) Frequency regulation ±1%
(B) Diesel Engine: - Adequate capacity of Diesel engine not less than 156 BHP (Minimum), 04 cylinder , Cubic capacity 4.32 Ltrs based on manufacturers technical details water cooled to drive independently the alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- (i) Fly wheel with housing (ii) Cooling system :- Mounted radiator with fan & belts. (iii) Cooling Water pump : - Centrifugal type belt driven. (iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacturer recommendation & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre. (v)Exhaust gas turbo charger type (vi)Exhaust manifold Silecer : Residual type Bellows
c) Annunciation with indication lamps for : (i) Low lub oil pressure.(ii) High Water Temparature.(iii) Engine over speed.(iv) Battery low voltage. Controls :- (a) Load on Indication (b) Load off indication (c) Engine start push button (d) Engine stop push button (e) Fault accept / reset push button (v) Battery Charger incorporated with : (a) Transformer (b) Rectifier (c) Restance (d) DC Volt meter, (e) DC Ammeter (vi)Protection :- (a) Over current relay - 01 No
(G) Approved designed to meet CPCB IV+ norms:- (i) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(ii) The generating set batteries and fuel tank should be housed inside the acoustic enclosure. (iiii) Fuel tank should be located inside the acoustic (iv) Construction Details/specification are as follows : - a) Outer body :- CRCA Sheet of 3.15mm thick. b) Doors :- CRCA sheet of 3.15 mm thick c) Sound Insulation :- 100 mm thick rock wool (64kg/Cum) v) The accoustic should be composite in construction and fully assembled integral unit. vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable inlsulated plat form. vii) The DG Set should be provided with external Emergency stop push button. viii) The enclosure should be provided with bulk head light fitting for inside illumination (ix) The noise level should be 75 db at 1m under free field conditions. x) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade and base frame as per manufacturer recommendation
M&L for XLPE insulated heavy duty electric cable and LT cable of size 120 Sqmm 3 ½ core with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall (including PVC conduit in suitable size and clamp) /pole and including taking down old unserviceable cable complete all as specified and directed of following sizes Note:- (i) Excavation & earth work, new sand, new bricks for cable protection shall be measured & paid seperatly in respective items here- in- before.
All as per item No 3 but size of LT cable 70 Sqmm 3 ½ core complete all as specified.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft /loose soil all as directed.Note - Excavation/earth work shall be done by manually manner with the safety of Data/OFC/telephone cable. If any cable damaged during the excavation to be repair same time and cost to be included in qouted rates.
Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25cm all as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed.(Note: Thickness after punning shall be measured for payment ) all as specified and directed.
Supplying & laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40 mm abetting Each other with gap between adjacent slab not exceeding 10 mm over under cable for protection all as specified and directed.
Supply and laying HDPE double wall corrugated pipe of size 32 mm dia with fittings as per IS marked clamping to wall for fixing for cable protection trenches complete all as specified & directed.
Material and labour for cutting of metallic road/ hard standing/hard rock/wall up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of protection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm grade crushed stone aggregate upto existing surface level or removing the any type of tiles carefully and refixing properly as per existing surface including suitable size of GI pipe (if necessary) complete all as specified and as directed.Note: 1. If damaged/broken the any type of tiles while removing, the contractor shall replace the broken tiles with new one.2. The Quoted rate is included for all materials/T&P/Machinery used in this item, no material can paid/measured separately.3. All the removable tiles/re fixable material shall kept carefully at a safe place for refixing with in this quoted rate.4. GI Pipe shall measured and paid separately under relevant item.
Supply of Earth electrode 17.2 mm dia 3 mtr long of low carbon steel electrode with copper bonding of thickness 250 micron, Back-fill earthing enhancing compound Carbon based compound conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill comound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per as per IEC: 62561-7 for Back-fill compound shall be submitted along with the material including SS clamp to be provode both side and PVC EARTH PIT 300 X 300 MM WITH PLASTIC LID complete all as specified.Note - (i) Earth electrode should be applicable Standards IS: 3043, IEC 62561-2 & IEC 60364-5 and made of High Tensile steel rods copper bounded, High tensile strength,good electrical conduction & effective performance and suitable for all type of soil and provided minimum distance 3 Mtrs. (ii) Back-fill compound should be Compliance to the Standards IEEE: 80, IS-3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification.(iii) Positive low resistance electrical connection to the earth. (iv) Does not contain hazardous chemicals.(v) Electronically conductive (like in metals) and is not dependent on moisture.
M& L for GI tubing light grade of size 50 mm dia fixed on walls / laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc including taking down of old unseviceable pipe any type and any size complete all as speified and directed.Note - Excavation to be paid separately in respective items.
M&L for Hardcore with broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
Material and labour for Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation all as specified and as directed.
Material and labour for Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in foundation, plinth courses, string courses, lacing courses, parapets with fair surface complete all as specified.
M&L for steel work in tubular pole,truss/rafter/purlins including nut bolt washers, screw complet using ERW or induction but welded tubes conforming to IS 1161,1979 grade St-240 complete as as specified.
M&L for preparation of new surface of any description over 10CM in width or girth not otherwise described complete all as specified and directed.
M&L for primming with red oxide of any of any description over 10 CM in width or girth not otherwise described complete all as specified and directed.
M&L for painting with synthetic enamel paint of any description over 10 CM in width or girth not otherwise described complete all as specified and directed.
M&L for pre painted galvalume aliminium zinc coating GI based corrugated steel sheet 0.50mm thick of san having tensile strength of 550 Mpa as in roof covvering clading to entire structure of shed fix with self taping screws and provide anti leacking arrangement complete all as specified and directed.
THE SUVASH AND SONS (BID ID -3364426)
Raj Construction (BID ID -3364286)
arics infrastructure (BID ID -3357741)
M/S RANKWAR CONSTRUCTION (BID ID -3364114)
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3372255)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .