SE RANDB KHURDA
O/o the SUPERINTENDING Engineer R and B Division, Khurda
Provision of Fire down comer system Booster pump,Fire Detection and PA system, Fire extinguisher and Signage at CHC Building at Chilika-Nuapada Buildings.
2026_EICCL_141402_1
TCN-14-26-27
Open Tender
Electrical Works
Percentage
60 days
Khordha
2 documents required · 2 mandatory
₹6,000
₹16,300
Yes
22 Sept 2026
22 Sept 2026
3 Oct 2026
22 Sept 2026
1 Oct 2026
22 Sept 2026
22 Sept 2026 - 1 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | TERRACE PIPING & ACCESSORIES Supply and Fixing of 1 Nos of 5000 ltr.triple layer plastic water storage tank for fire fighting hydrant system to be placed at terace level.Make: Sinttex/Plasto | 1 | each | 47,388 | ₹47,388 |
| 2 | Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.Make Wilo/KSB/Kirloskar/Grundfoss | 1 | set | 65,480 | ₹65,480 |
| 3 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1) 63 Amp, 10 KA,TPN (Class C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make Legrand/schneider/Siemens/ABB | 1 | set | 37,800 | ₹37,800 |
| 4 | Supplying, Installing, Testing and commissioning of 1100 V GRADE POWER/CONTROL CABLES :SITC of FRLS, PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge. Size 4C x 16 Sqmm. Make Polycab / KEI/Gloster/RR kabel/Havells/Finolex | 83 | rm | 480 | ₹39,840 |
| 5 | Supplying, installing, testing and commissioning of 2C x 1.5 sq. mm, Twisted Pair PVC insulated FRLS Armored Cable with Accessories confirming to IS standards and specifications. The quoted rate shall includes of Acrylic Fire stop Sealant in the opening for cables passing through fire compartment walls of RCC floors, masonry walls to provide up to 2 hours fire rating. Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Gloster/V Guard | 83 | rm | 141 | ₹11,703 |
| 6 | Supplying, installation testing and commissioning of the following C class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pipe coat (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation.Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete.
Make TATA/JINDAL/SAIL
100mm NB | 109 | mtr | 2,457 | ₹2,67,813 |
| 7 | 80mm NB | 5 | mtr | 1,360 | ₹6,800 |
| 8 | 25mm NB | 5 | mtr | 618 | ₹3,090 |
| 9 | Supply and installation, testing and commissioning of CI Butterfly valves ( heavy ) conforming to BS 5155 ,PN1.6 tested to 1.5 times working pressure with necessary companion flanges, bolts, nuts, gasket packing, support and any other spares, including indicator for open and shut position as per fire practice etc complete..Make Zoloto/Audco/Leader.100 mm dia | 2 | nos | 5,330 | ₹10,660 |
| 10 | SITC of NRV conforming to IS 5312 (swing type) or to API 594/598 (dual plate check type) with CI body & brass trim part, PN 1.0 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved make.Make Zoloto/Audco/Leader. Size : 100 mm dia | 1 | nos | 6,470 | ₹6,470 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 1.52 MB
Tendernotice_1.pdf
PDF • 0.35 MB
BOQ_610384.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .