Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹24.8 L+₹2,995.90 (0.12%)Rejected-Finance | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹26.3 L+₹1.5 L (6.17%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance RATE HIGH | |
| 4 | L4₹28.3 L+₹3.5 L (14.2%)Rejected-Finance MOURYA HEIGHTS SATAVNAGAR HANDEWADI ROAD HADAPSAR PUNE 28 | PUNE | MAHARASHTRA | 411028 | L4 | Rejected-Finance RATE HIGH | |
| 5 | L5₹28.3 L+₹3.5 L (14.3%)Rejected-Finance 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L5 | Rejected-Finance RATE HIGH |
| Sl No | Description | Qty | Unit | REKHA ELECTRICALS L2 | M/s.BAJRANG CONSTRUCTION L5 | Suchit constructions L1 | Gauri Associates L4 | R R Associates L6 | N B ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying, installing, testing and commissioning at any hight of BEE 5 star split type variable speed inverter technology with minimum 5 -in 1 convertible mode for compressor air conditioning unit 1.5 TR cooling capacity having ISEER 5 & above suitable to operate on 230 V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant Refrigerant 410 A/R-32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50.2 dBA at position including industrial socket, 4 Sqmm 3 core insulated copper conductor from outdoor unit to socket outlet and making hole in wall, minor carpentry and civil work and U PVC drain piping of 25mm bore with its all accessories like bend, solution etc as per site condition and writing GE(S), Pune SM No / MES No with black paint of letter size of 2cm complete all as specified and as directed by Engr-in-Charge.
Note :-Necessary T& P Required For installation Shall Be Included In Quoted Rate | 17 | Each | 46,500 ₹7,90,500 | 44,500 ₹7,56,500 | 44,100 ₹7,49,700 Lowest | 48,000 ₹8,16,000 | 49,000 ₹8,33,000 | 54,000 ₹9,18,000 |
| 2.00 | M&L for soft annealed copper tubing, confirming to relevant IS, 5/8" and 3/8" flare size or as required at site for connecting indoor and outdoor unit gas system including suitable size 4 core 6 sqmm copper cable, PVC drain pipe and insulation with superlon insulation to copper tubing of required length complete all as directed by Engr-in-Charge.
Note:- Both inlet and outlet copper tubing with insulation, copper cable and PVC drain pipe will be measurd as one RM. | 170 | RM | 650 ₹1,10,500 | 1,050 ₹1,78,500 | 702 ₹1,19,340 | 1,200 ₹2,04,000 | 400 ₹68,000 Lowest | 850 ₹1,44,500 |
| 3.00 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, Make V-Guard VG500, complete all as directed by Engr-in-Charge | 17 | Each | 2,900 ₹49,300 Lowest | 3,950 ₹67,150 | 4,230 ₹71,910 | 4,500 ₹76,500 | 6,500 ₹1,10,500 | 3,000 ₹51,000 |
| 4.00 | Supply and fix single pole and neutral enclosures with a two pin and earth plug and socket complete with one double pole MCB 20 A, 240 V complete all as directed by Engr-in-Charge | 17 | Each | 850 ₹14,450 | 750 ₹12,750 Lowest | 1,080 ₹18,360 | 1,100 ₹18,700 | 900 ₹15,300 | 1,200 ₹20,400 |
| 5.00 | M&L sub main wiring concealed / surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run o f 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as directed by Engr-in-Charge.
Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one unit length. | 350 | RM | 190 ₹66,500 | 405 ₹1,41,750 | 207 ₹72,450 | 180 ₹63,000 | 167 ₹58,450 Lowest | 240 ₹84,000 |
| 6.00 | Supply and fixing load line distribution board TPN vertical, 4 way double door type,with IP 54 protection fixed on wall or semi flush with incoming MCCB 4 poles 125 Amps, 16 KA, busbars , isolated neutral link bar , blanking plates, door earthing complete with all accessories complete all as directed by Engr-in-Charge.
Note: Outgoing MCBs shall be measured and paid separately. | 2 | Each | 10,200 ₹20,400 Lowest | 14,500 ₹29,000 | 14,400 ₹28,800 | 12,000 ₹24,000 | 14,000 ₹28,000 | 12,500 ₹25,000 |
| 7.00 | M&L submain wiring concealed type/surface type with four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 10 Sqmm, 1100 volts grade (FRLS) and one run o f 10 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as directed by Engr-in-Charge.
Note :- Four runs of 10 Sqmm cable, one run of 10 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one unit length). | 70 | RM | 1,700 ₹1,19,000 | 1,575 ₹1,10,250 | 900 ₹63,000 | 830 ₹58,100 | 690 ₹48,300 Lowest | 1,000 ₹70,000 |
| 8.00 | S&F MCB, SPN, 240 Volts, 5 to 32 Amps. 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and neutral in the MCB DB complete all as specified and as directed | 17 | Each | 650 ₹11,050 | 700 ₹11,900 | 504 ₹8,568 | 900 ₹15,300 | 150 ₹2,550 Lowest | 200 ₹3,400 |
| 9.00 | Demolition of cement concrete of any description in any position in sunken floor and roof slab padding & like etc including removal of debris outside MD land and dumping ground will be sorted out by contractor at their own arrangement complete all as specified and as directed. | 37.5 | Cum | 1,000 ₹37,500 | 250 ₹9,375 | 360 ₹13,500 | 170 ₹6,375 Lowest | 1,000 ₹37,500 | 300 ₹11,250 |
| 10.00 | M&L for cleaning of surfaces by brushing and washing with water of any description and Provide padding of PCC 1:2:4 type B-0 of uniform thickness of 50mm in two layers of 25mm thickness with chicken wire mess 0.91 mm dia, laid between two layers and of 12x12mm aperture.Top surfaces of PCC padding shall be finished even and smooth without using extra cement with false groove at 300x330 mm centre to centre, laid in slope.(Using water proofing compound of 3% by weight of cement) (Note : Wpc shall be measured and paid seperately) | 770 | Sqm | 200 ₹1,54,000 | 450 ₹3,46,500 | 207 ₹1,59,390 | 275 ₹2,11,750 | 470 ₹3,61,900 | 120 ₹92,400 Lowest |
Tender Value
₹36.7 L
EMD Value
₹73,480
Closing Date
15 Jan 2026, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GEN BHAGAT MARG PUNE
ADDITIONAL ALTERATION TO ROOF TREATMENT AND CHAJJA OF HOSTEL BUILDING AND SPECIAL REPAIR TO AC AGAINST BER AT NADFM UNDER GE (SOUTH) PUNE
2025_MES_743021_2
8778 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
120 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹73,480
Yes
24 Mar 2026
1 Jan 2026
17 Jan 2026
1 Jan 2026
15 Jan 2026
10 Jan 2026
Supplying, installing, testing and commissioning at any hight of BEE 5 star split type variable speed inverter technology with minimum 5 -in 1 convertible mode for compressor air conditioning unit 1.5 TR cooling capacity having ISEER 5 & above suitable to operate on 230 V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant Refrigerant 410 A/R-32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50.2 dBA at position including industrial socket, 4 Sqmm 3 core insulated copper conductor from outdoor unit to socket outlet and making hole in wall, minor carpentry and civil work and U PVC drain piping of 25mm bore with its all accessories like bend, solution etc as per site condition and writing GE(S), Pune SM No / MES No with black paint of letter size of 2cm complete all as specified and as directed by Engr-in-Charge. Note :-Necessary T& P Required For installation Shall Be Included In Quoted Rate
M&L for soft annealed copper tubing, confirming to relevant IS, 5/8" and 3/8" flare size or as required at site for connecting indoor and outdoor unit gas system including suitable size 4 core 6 sqmm copper cable, PVC drain pipe and insulation with superlon insulation to copper tubing of required length complete all as directed by Engr-in-Charge. Note:- Both inlet and outlet copper tubing with insulation, copper cable and PVC drain pipe will be measurd as one RM.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, Make V-Guard VG500, complete all as directed by Engr-in-Charge
Supply and fix single pole and neutral enclosures with a two pin and earth plug and socket complete with one double pole MCB 20 A, 240 V complete all as directed by Engr-in-Charge
M&L sub main wiring concealed / surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run o f 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as directed by Engr-in-Charge. Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one unit length.
Supply and fixing load line distribution board TPN vertical, 4 way double door type,with IP 54 protection fixed on wall or semi flush with incoming MCCB 4 poles 125 Amps, 16 KA, busbars , isolated neutral link bar , blanking plates, door earthing complete with all accessories complete all as directed by Engr-in-Charge. Note: Outgoing MCBs shall be measured and paid separately.
M&L submain wiring concealed type/surface type with four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 10 Sqmm, 1100 volts grade (FRLS) and one run o f 10 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as directed by Engr-in-Charge. Note :- Four runs of 10 Sqmm cable, one run of 10 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one unit length).
S&F MCB, SPN, 240 Volts, 5 to 32 Amps. 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and neutral in the MCB DB complete all as specified and as directed
Demolition of cement concrete of any description in any position in sunken floor and roof slab padding & like etc including removal of debris outside MD land and dumping ground will be sorted out by contractor at their own arrangement complete all as specified and as directed.
M&L for cleaning of surfaces by brushing and washing with water of any description and Provide padding of PCC 1:2:4 type B-0 of uniform thickness of 50mm in two layers of 25mm thickness with chicken wire mess 0.91 mm dia, laid between two layers and of 12x12mm aperture.Top surfaces of PCC padding shall be finished even and smooth without using extra cement with false groove at 300x330 mm centre to centre, laid in slope.(Using water proofing compound of 3% by weight of cement) (Note : Wpc shall be measured and paid seperately)
M & L Water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below including Removing of existing bitumenous tarfelt including cement screed bed and clean the surface with wire brush and washing with water to achieve the original surface of slab including removing of bitumen primer applied on slab all as spd and as directed by Engineer-in-Charge. (a) Rendering 10mm thick cement plaster in CM (1:4) complete all as directed by Engr-in-Charge (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of ShaliTex primer (solvent based bituminous primer) conforms to IS: 3384-1986 coat of ShaliTex primer @ 0.3 Kg/Sqm shall be applied on the prepared and cleaned roof surface and parapet. Ensure not to apply when temperature is less than 5° C or during foggy period. Primer shall be allowed to dry for overnight.
(c) Providing and laying APP (Atactic Polypropylene polymer) 3mm thick SuperThermolay Spun bonded non woven polyester reinforced APP modified water proofing membrane, black finished reinforced with non woven polyester matt weight not less than 3.5 Kg/Sqm manufactured by STP Ltd. The laying of membrane with a 75 mm longitudinal and 100mm transverse direction overlap shall be provided and laid using LPG torch and sealing all joints etc (d) Finally applying a coat of Super Silver Shield confirmed to IS: solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge. (Make: STP Ltd or equivalent in Supremo/ pidilite/fosroc) Note : i) Work should be done by STP Ltd (OEM) /fosroc /Pidilite /Suprimo (OEM) respective applicator & work should be able to furnish stagewise on site technical reports from concerned company technologist during currency of work and entire completion of work. ii) Contractor shall submitt 10 year OEM guaranttee for water proof treatment.
Supply only Integral waterproofing compound only (Make:- Pidilite CF 21 by Pidilite, DR.FIXIT, ShaliPlast LW+ by STP Ltd.) [Note : Contractor shall bring complete material incorporated in work with concern executive.]
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3
M&Lfor Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of n.exc 1000 m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination ® (1 Load =0.65 Cum)
Removing of existing water tank of capacity 500,1000 or 2000 Ltr setting aside (or lowering if required) for repair, cleaning etc and reconnecting & refixing in position after carrying out necessary roof treatment including necessary fittings and GI Pipes if required. (NOTE : Necessary by pass arrangements for water supply is to be done by the contractor till completion of roof work.)
Supply and fix in replacement rotational moulded polyethylene water storage tanks in replacement (vertical cylindrical with closed top) double layered ISI marked with existing inlet, outlets & provision of washouts, (vent pipe all as directed of following capacity including all new tank nipples of suitable size.
M&L for Taking up or down GI water tubing with fittings including cleaning for re-fixing and Refixing old steel tubing and connection/fitting in new or old position (wall, ceiling, floors etc) all as specified and directed. (Note : The quoted rate deemed to include for new fittings as required of site.)
(a) 20 mm bore
(b) 25 mm dia
(c) 32 mm bore
M&L for taking up and down and New Supply and fixing of GI water tubing,medium grade with fittings, fixed to wall and ceiling (conceled) or laid in floor of size including taking down GI water tubing with fittings
(a) 20 mm bore
(b) 25 mm bore
(c) 32 mm bore
Taking down plastering in cement mortar on brick or stone walls,etc. including raking out joints,hacking for key,scrubbing down with water,etc.complete all as specified and as directed
M&L rendering 15 mm thick in cement sand mortar ( 1:4), on fair face of brick work or concrete surfaces or chajja finished fair and even mixed with WPC as per manufacturers instruction complete all as specified and directed. (WPC shall be measured and paid separately) Note height for plaster work are including upto 12 M height
Material & Labour for Prepration of new surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed
M&L for Mild Steel framed work conforming to Fe-290 (Gde E-165), as in roof trusses (framed), trussed, purlins, crane gantries rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat section ) including distance pieces, cleats etc, and welding or riveted complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth, not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
S & F roof sheeting prepainted galvalume aluminium zinc coating 150 gms GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to all, fixed with self tapping screws including taking down old AC sheet complete all as specified and as directed.
M&L PCC (1:2:4) type B-1 using 20 mm stone graded aggregate as in roof kerb or benching to MH and coping etc complete. Including Demolition of PCC complete all as specified and as directed
M & L 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified
S & F 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed .
S&F in repairs PVC(SWR) branch piece double equal or unequal 110 mm bore with access door complete all as specified and as directed.
S & F in repair of 32 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified.
S & F in repair of 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified.
S & F 32 mm bore ball brass valves high pressure with polythene float and flynut complete screwed or iron etc complete all as specified.
S & F 25 mm bore ball brass valves high pressure with polythene float and flynut complete screwed or iron etc complete all as specified.
M&L for demolition of concrete surfaces and carry out the Roof Treatment and also apply the following process:- (i) open all cracks, clean, filling crack joints with Pidilite (Dr Fixit) Compound. (ii) Removing all dead skin and applying hard brushing for cleaning. (iii) pressure washing. (iv) U.R.P. & cement pesting.(v) leveling. (vi) Fiber mash pesting with U.R.P & Cement . (vii) apply priming coating (viii) three coats are apply on conc. surfaces New Coat Processing (First Coat), Again New Coat Processing (Second Coat) and Finaly New Coat Processing (Third Coat) on roof comp. The coy has also give the Ten year Guarantee for Roof Treatment (natural disaster no applicable) . The treatment to be carried out on the concrete surfaces including cleaning all RCC surfaces as per manufacturer's specification/ datasheet and material should be utilised authorised coy, pidilite (Dr Fixit) comp all specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
8778TD.pdf
Tender Documents • 0.94 MB
BOQ_836354.xls
BOQ • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .