Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹30.5 L+₹52,684.60 (1.76%)Rejected-AOC | L2 | Rejected-AOC REJECT | |
| 3 | L3₹32.0 L+₹2.0 L (6.62%)Rejected-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L3 | Rejected-AOC REJECT | |
| 4 | L4₹32.0 L+₹2.0 L (6.67%)Rejected-AOC | L4 | Rejected-AOC REJECT |
Tender Value
₹29.1 L
EMD Value
₹58,300
Closing Date
28 Jan 2022, 6:00 pmClosed
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
SPECIAL REPAIR / REPLACEMENT OF OH LT LINE TO UG LT CABLE AT WKSP AREA UNDER GE PANAGARH
2021_MES_486164_2
8731/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PANAGARH
Pl refer Tender Documents
7 documents required · 7 mandatory
₹500
GE PANAGARH
₹58,300
Yes
17 Feb 2022
6 Jan 2022
31 Jan 2022
6 Jan 2022
28 Jan 2022
14 Jan 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil, complete all as specified and as directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc. 25cmin soft/loose soil, complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed.
Dismantling cross arms of MS channel or angle iron sections etc and setting aside , complete all as specified and as directed.
Dismantling of insulators any type any size, complete all as specified and as directed.
Dismantling steel earth wire from existing overhead service feeder etc , complete all as specified and as directed.
Dismantling ACSR conductor of any size from existing overhead service feeder etc , complete all as specified and as directed.
S&F 80 mm bore GI tubing medium grade ISI marked for protection of cable including necessary joint, complete all as specified and as directed.
S&F in repair's 40 mm bore GI tubing medium grade ISI marked for protection of cable including necessary joint, complete all as specified and as directed.
M&L and testing in passing through HDPE DWC Pipe of suitable size 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 240 Sqmm 3.5 core, complete all as specified and as directed. Note : (1) Cost of HDPE DWC pipe to be catered in item rate and prior approval for colour of pipe to be taken from Engr-in-Charge, (2) DWC high density Polyethylene pipe shall have corrugation on outer wall but inner wall shall be plain with ISI marka conforming to IS – 14930 Part I and II amended from time to time and Accessories like HDPE snap fit coupler with neoprene ‘O’ ring shall be part of supply to make the joints water / damp proof. (3) Cable route indicator of metal of height 600 mm, 450 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
M&L and testing in passing through HDPE DWC Pipe of suitable size 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 120 Sqmm 3.5 core, complete all as specified and as directed. Note : (1) Cost of HDPE DWC pipe to be catered in item rate and prior approval for colour of pipe to be taken from Engr-in-Charge, (2) DWC high density Polyethylene pipe shall have corrugation on outer wall but inner wall shall be plain with ISI marka conforming to IS – 14930 Part I and II amended from time to time and Accessories like HDPE snap fit coupler with neoprene ‘O’ ring shall be part of supply to make the joints water / damp proof. (3) Cable route indicator of metal of height 600 mm, 450 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
M&L and testing in passing through HDPE DWC Pipe of suitable size 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 95 Sqmm 3.5 core, complete all as specified and as directed. Note : (1) Cost of HDPE DWC pipe to be catered in item rate and prior approval for colour of pipe to be taken from Engr-in-Charge, (2) DWC high density Polyethylene pipe shall have corrugation on outer wall but inner wall shall be plain with ISI marka conforming to IS – 14930 Part I and II amended from time to time and Accessories like HDPE snap fit coupler with neoprene ‘O’ ring shall be part of supply to make the joints water / damp proof. (3) Cable route indicator of metal of height 600 mm, 450 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
M&L and testing in passing through HDPE DWC Pipe of suitable size 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 70 Sqmm 3.5 core, complete all as specified and as directed. Note : (1) Cost of HDPE DWC pipe to be catered in item rate and prior approval for colour of pipe to be taken from Engr-in-Charge, (2) DWC high density Polyethylene pipe shall have corrugation on outer wall but inner wall shall be plain with ISI marka conforming to IS – 14930 Part I and II amended from time to time and Accessories like HDPE snap fit coupler with neoprene ‘O’ ring shall be part of supply to make the joints water / damp proof. (3) Cable route indicator of metal of height 600 mm, 450 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
M&L and testing in passing through HDPE DWC Pipe of suitable size 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 25 Sqmm 4 core, complete all as specified and as directed. Note : (1) Cost of HDPE DWC pipe to be catered in item rate and prior approval for colour of pipe to be taken from Engr-in-Charge, (2) DWC high density Polyethylene pipe shall have corrugation on outer wall but inner wall shall be plain with ISI marka conforming to IS – 14930 Part I and II amended from time to time and Accessories like HDPE snap fit coupler with neoprene ‘O’ ring shall be part of supply to make the joints water / damp proof. (3) Cable route indicator of metal of height 600 mm, 450 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
M&L and testing in passing through HDPE DWC Pipe of suitable size 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 16 Sqmm 4 core, complete all as specified and as directed. Note : (1) Cost of HDPE DWC pipe to be catered in item rate and prior approval for colour of pipe to be taken from Engr-in-Charge, (2) DWC high density Polyethylene pipe shall have corrugation on outer wall but inner wall shall be plain with ISI marka conforming to IS – 14930 Part I and II amended from time to time and Accessories like HDPE snap fit coupler with neoprene ‘O’ ring shall be part of supply to make the joints water / damp proof. (3) Cable route indicator of metal of height 600 mm, 450 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
M&L and testing in passing through HDPE DWC Pipe of suitable size 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 10 Sqmm 2 core, complete all as specified and as directed. Note : (1) Cost of HDPE DWC pipe to be catered in item rate and prior approval for colour of pipe to be taken from Engr-in-Charge, (2) DWC high density Polyethylene pipe shall have corrugation on outer wall but inner wall shall be plain with ISI marka conforming to IS – 14930 Part I and II amended from time to time and Accessories like HDPE snap fit coupler with neoprene ‘O’ ring shall be part of supply to make the joints water / damp proof. (3) Cable route indicator of metal of height 600 mm, 450 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 150-185 Sqmm 4 Core including testing after jointing complete all as specified & as directed.
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 70-120 Sqmm 4 Core including testing after jointing complete all as specified & as directed.
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 25-50 Sqmm 4 Core including testing after jointing complete all as specified & as directed.
Supply & fixing Street light fitting LED type capacity 60 W die-cast aluminium body, 60 watt LED 6000K lense type and toughened glass with Surge protection Device with 1.2 meter length suitable size GI bracket and MS clamps , complete all as specified and as directed.
S&F in repair's circuit / submain wiring alongwith earth wire in PVC conduit with FR PVC insulated copper conductor , 2 x 1.5 Sqmm + 1 x 1.5 Sqmm single core in surface including necessary MS clamps , complete all as specified and as directed.
Supply & Fix junction box made of Polycarbonate with IP 65 degree of protection , dust proof, water tight, light weight, acid resistant, corrosion proof inslated & shock proof, fire retardant, self extinguishing, halogen & silica free non-toxic material, UV resistant, with internally ebbedded gasket fitted with required terminals for upto size 25 sqmm 4 core cable and including 1x10A SP, 10 KA MCB fitted on DIN Rail and including Brass Glands , complete all as specified and as directed.
Dismantling existing Steel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc , complete all as specified and as directed.
M&L for Steel tubular swaged poles complete with cast iron/MS base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31 , 9 meter long including PCC (1:3:6) type C2 (using 40 mm stone graded stone aggregate in foundation and coping with PCC (1:2:4) type B-1 (using 20mm stone aggregate), complete all as specified & as directed. Note: Earth work and PCC for pole fixing will be measured and paid separately
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundation for stay set /Pole/ FPB etc including fair finish even and fir to exposed surfaces without using extra cement, complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as in coping of pole/panel including necessary form work as required , complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 25 mm x 4 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 3 including testing on completion, complete all as specified and as directed incl demolition to existing one.
Supply, commissioning and testing Outdoor type LT Distribution Panel, Double door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, suitable size for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement New Panel board shall comprise of :- (a) Copper Busbar rating- 800 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB - 320 Amp, 4 pole, 50 KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No (Incomer) (d) MCCB-160 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-03 No(Outgoing) (e) MCCB-100 Amp, 4 pole, 18 KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-06 No(Outgoing) (f) MCCB-63 Amp, 4 pole, 18 KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (g) MCB 32A DP , C Curve 10 KA, 230 V - 08 Nos (Outgoing) (h) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (j) S & F digital voltmeter 0-500 V = 01 Nos (Note: PCC rate for panel to be included in this item rate)
Supply, commissioning and testing Outdoor type LT Distribution Panel, Double door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, suitable size for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement New Panel board shall comprise of :- (a) Copper Busbar rating- 200 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB - 100 Amp, 4 pole, 18 KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No (Incomer) (d) MCCB-63 Amp, 4 pole, 18 KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-07 No(Outgoing) (e) MCB 32A DP , C Curve 10 KA, 230 V - 12 Nos (Outgoing) (f) S&F digital ampere meter 3 line display incl CT having CTR 100/5-01 Nos (g) S& F digital voltmeter 0-500 V = 01 Nos (Note: PCC rate for panel to be included in this item rate)
Supply, commissioning and testing Outdoor type LT Distribution Panel, Double door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, suitable size for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement New Panel board shall comprise of :- (a) Copper Busbar rating- 250 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB - 160 Amp, 4 pole, 25 KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No (Incomer) (d) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (e) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (f) MCB 32A DP , C Curve 10 KA, 230 V - 12 Nos (Outgoing) (g) S&F digital ampere meter 3 line display incl CT having CTR 200/5-01 Nos (h) S& F digital voltmeter 0-500 V = 01 Nos (Note: PCC rate for panel to be included in this item rate)
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure.
Schedule of Credit
BISWAS ENTERPRISE
M/S Ali Trading Co
S S ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .