Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹16.6 L+₹2.0 L (13.7%)Rejected-Finance AMBAGAN TEZPUR TOWN PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹17.7 L+₹3.1 L (21.5%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L3 | Rejected-Finance HIGH BID VALUE | |
| 4 | L4₹19.4 L+₹4.9 L (33.5%)Rejected-Finance A 306 SAISHA RESIDENCY PLOT NO 99 SECTOR 35 KAMOTHE RAIGAD MAHARASHTRA 410209 UDYAM MH 27 0136235 | RAIGAD | MAHARASHTRA | 410209 | L4 | Rejected-Finance HIGH BID VALUE | |
| 5 | L5₹22.2 L+₹7.7 L (52.6%)Rejected-Finance | L5 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹22.3 L
EMD Value
₹44,600
Closing Date
28 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL GANESH ZAPE
HQ CWE Tenga C/O 99 APO
PROVN OF 01X250 KVA TRANSFORMER AT MISSAMARI
2022_MES_555173_1
8319/E8
Open Tender
Civil Works
Item Rate
180 days
GE MISSAMARI
D and above and b ii
8 documents required · 8 mandatory
₹500
Yes
GE MISSAMARI
₹44,600
Yes
30 Nov 2022
30 Sept 2022
4 Nov 2022
30 Sept 2022
28 Oct 2022
14 Oct 2022
Amount
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre depth for laying of UG cable / pole etc getting out including forming bottom surface to required level and gradient in soft/loose soil complete all as specified and as directed.
Returning and filling in excavated soil including spreading leveling, watering, well ramming in layers not exc 25 Cm thick complete all as specified and as directed.
Removing of excavated materials not exceeding 50 metre and depositing where directed by Engr in Charge at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Supply and laying well burnt Bricks , locally available best quality (sub class "B" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified and as directed.
M&L Clean dry river sand in trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified and as directed.
Supply, install, test and commission step down transformer, outdoor type, plinth mounted HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating, level-02 of capacity 250 KVA incl bushing on HT end cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil, etc, and conforming to IS 1180 Part-1:2014 duly mounted on plinth and all as specified and as directed. (a) Oil conservator with filling hole, cap and drain plug (b) Silica gel breather with oil seal and first fills of dehydrating agent (c) Adequate Nos of thermometer pockets incl one No for accomodating bulb type thermometer (d) Drain cum bottom filter valve (e) Top filter valve (f) Prisomatic oil level gauge (g) Inspection cover (h) Cover fitting lugs (j) Jacking and fitting lugs (k) Separate neutral bushing brought out for earthing on LV side (l) Earthing terminal Note: PCC platform / plinth for placing transformer is not included in the quoted rate and will be measured and paid under seperate item.
Supply & Laying, testing & commissioning of LT UG cable XLPE sheathed PVC insulated,screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in trenches, in GI pipe , including brass cable glands, clamps etc of size 3.5 core x 400 sq mm complete all as specified. Note : Earthwork, sand cushioning, bricks, GI pipe, etc will be measured and paid under appropriate items
M&L for earthing complete with GI Earth Electrode 600mmX600MMx6MM thick buried directly in ground vertically to a depth not less 2.25 mtr below ground level with top edge of earth plate a depth not less than 1.50 mtr below Normal Ground level connection to GI strip 32x6 mm drawn through and including galvanised iron protection pipe 40 mm bore (dia)Light grade up to height of the transformer foundation where foundation situated by means of bolt Nuts check Nuts and washers etc earth plate surroumded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150 mm thick PCC pit in cement concreate 1:3:6 ( 20mm graded aggreage ) Pre cast RCC 1:2:4 (20 MM graded aggreagate Cover slab 350X350X50MM thick reinforce with including 8mm dia TMT Bars@10 CM centre to centre both ways GI Wire Mess,Funnel with GI watering pipe 20 MM bore diaMedium grade necessary excavation in soft loose soil returning fillingin and revoal of surplus soil upto a distance of 50 Mtr and all as shown in electrical plate No 3 of MES schedule Part -I and testing on completion complete all as specified and as directed. Note:- 02 Nos for Transformer Body and 02 Nos for main LT panel.
M&L for earthing complete with GI Earth Electrode 600mmX600MMx6MM thick buried directly in ground vertically to a depth not less 2.25 mtr below ground level with top edge of earth plate a depth not less than 1.50 mtr below Normal Ground level connection to galvanised iron as earth lead 4mm dia drawn through and including galvanised iron protection pipe 15 mm bore (dia)Light grade up to 1 .0 Mtr above the ground level of HT pole foundation where PCC pole situated by means of bolt Nuts check Nuts and washers etc earth plate surroumded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150 mm thick PCC pit in cement concreate 1:3:6 ( 20mm graded aggreage ) Pre cast RCC 1:2:4 (20 MM graded aggreagate Cover slab 350X350X50MM thick reinforce with including 8mm dia TMT Bars@10 CM centre to centre both ways GI Wire Mess,Funnel with GI watering pipe 20 MM bore diaMedium grade necessary excavation in soft loose soil returning fillingin and revoal of surplus soil upto a distance of 50 Mtr and all as shown in electrical plate No 3 of MES schedule Part -I and testing on completion complete all as specified and as directed.
M&L for earthing complete with copper Earth Electrode 600mmX600MMx6MM thick buried directly in ground vertically to a depth not less 2.25 mtr below ground level with top edge of earth plate a depth not less than 1.50 mtr below Normal Ground level connection to copper strip 20x3 mm drawn through and including galvanised iron protection pipe 40 mm bore (dia)Light grade up to height of the transformer foundation where foundation situated by means of bolt Nuts check Nuts and washers etc earth plate surroumded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150 mm thick PCC pit in cement concreate 1:3:6 ( 20mm graded aggreage ) Pre cast RCC 1:2:4 (20 MM graded aggreagate Cover slab 350X350X50MM thick reinforce with including 8mm dia TMT Bars@10 CM centre to centre both ways GI Wire Mess,Funnel with GI watering pipe 20 MM bore diaMedium grade necessary excavation in soft loose soil returning fillingin and revoal of surplus soil upto a distance of 50 Mtr and all as shown in electrical plate No 3 of MES schedule Part -I and testing on completion complete all as specified and as directed.
M&L Test point terminal block made of gun metal or phosphorus bronze size 75X75X25mm dnilled and screwed including 3 Nos 8 mm dia 25mm long hex head screw complete all as specified and directed by Engr-in-charge
Surface dressing in soft loose soil n exc 15 cm deep and getting out complete all as specified and as directed.
M&L for Cement Concrete 1:4:8 (40mm graded aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Formwork (as/if required), complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm aggregate) as in foundation for pole etc.complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm aggregate) as in coping of pole, top surface of transformer foundation etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and as directed.
M&L for anti-climbing device comprising 2.24mm dia galvanised steel 2 strand barbed wire with 2.24 mm dia barbs wrapped spirally round poles, to a length of 5 to 1.0 mtr clamed and properly secured or as ordered clamps measured separately
M&L for brick work with burnt old size bricks built in cement mortar 1:6 straight or curved on plan exceeding 6mtr mean radius and all as directed.
M&L for rendering 15 mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth complete all as specified and as directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface for footpath and stone aggregate around perimeter of transformer fondation complete all as specified and as directed.
M&L for Cement concrete 100 mm thick type C-2, 1:3:6 (40mm graded aggregate ) for footpath complete all as specified and as directed.
M&L for Cement concrete 40 mm thick type C-2, 1:2:4 (40mm graded aggregate ) for footpath complete all as specified and as directed.
M&L for Hardcore of gauge n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface for stone aggregate around perimeter of transformer foundation complete all as specified and as directed.
M&L for three coat of white wash on wall surface including preparation of surface complete all as specified and as directed.
M/S S.S.Corporation
PURBANCHAL BUILDERS
R C TRADING COMPANY
JAMDAGNI ENGG WORKS
Saraswati Auto Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .