Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹29.8 L+₹1.9 L (6.89%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹32.0 L+₹4.1 L (14.9%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹33.3 L+₹5.5 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹33.9 L+₹6.0 L (21.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Jan 2022, 6:00 pmClosed
GE (CENTRAL) KIRKEE
GE (CENTRAL) KIRKEE, RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIR MAINTENANCE REPLACEMENT OF LT OUTDOOR PANELS OH LT UNDERGROUND CABLE AND SERVICING OF SWITCH GEAR WITH CONNECTED ITEMS UNDER EM II IN GE C KIRKEE
2021_MES_492463_1
8557/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE (CENTRAL) KIRKEE
₹90,000
Yes
1 Feb 2022
4 Dec 2021
3 Jan 2022
4 Dec 2021
1 Jan 2022
20 Dec 2021
4 Dec 2021 - 18 Dec 2021
Amount
Material & Labour for disconnecting LT XLPE cable of any size from LT Panel, any location as directed for finding fault and Material & Labour for defect rectification of underground cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. complete all as specified and as directed by Engineer in Charge. Note: (i) The fault locating equipments shall be brought to site within the 12 hours of instruction from Engr-in-Charge. (ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and contractor has to rectify the fault within 12 hours after notification, failing which Rs 500/- per day per complaint shall be deduected from the dues to the contractor. (iii) Rate quoted by contractor is deemed to be inclusive of cost towards earth work required for job.
Supplying, fixing, jointing and testing heat shrinkable Straight through joint , with and including jointing materials and necessary earth work suitable for 1100 V , XLPE LT cable of size 25-50 sqmm , 3.5/4 core , complete all as specified and as directed by Engineer in Charge.
All as per item Ser No 2.00 above but for cable of size 70-120 Sqmm, 3.5 core - complete all as specified and as directed by Engineer in Charge.
All as per item Ser No 2.00 above but cable of size 150-185 Sqmm, 3.5 core - complete all as specified and as directed by Engineer in Charge.
All as per item Ser No 2.00 above but cable of size 240-400 Sqmm, 3.5 core - complete all as specified and as directed by Engineer in Charge.
Material & Labour for repair/maint of LT panel board, of any size, any capacity outdoor/indoor type, duly disconnecting existing incomer/outgoing LT Cables any size, taking out all unserviceable MCCBs/MCBs/ bus bar, internal wiring, insulators, cleaning complete panel internally and externally, carrying out necessary repair work of welding, painting complete with spray painting. Installing existing bus bar duly new heat shrink insulating sleeves, new post insulators,door gasket, nut, bolts and washers. Rewiring of complete panel board as per existing with new wire of suitable size, replacement of unserviceable MCCB, MCB, meters, indicators complete. connecting incomer and outgoing LT Cable all as per exisitng, complete all as specified and as directed by Engineer in Charge. Note: (i) Quoted rates are deemed to be inclusive of minor items like cleaning material, insulators, wire, sleeves, gasket, welding work, cable lugs, insulation tape etc and excluding MCCB, MCB, meters, indicators etc required for job. (ii) Quoted rates includes necessary earth work for disconnecting LT cable. (iii) Contractor should report to MES Rep for necessary shutdown for the respective feeder and should insure safety to avoid any untowards incident. All T&P and safety eqpts shall be provided by the contractor to worker at hisown expense.
Supply only following items for incorporation in Item No 6.00 above as replacment of old unserviceable items:- Note: fixing charges included in the item No 6.00.
MCCB of 4 pole 63 Amps 415 Volts with breaking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge. Make: Legrand (Cat No: 669716) or equivalent from list of make as approved by GE.
MCCB of 4 pole 100 Amps 415 Volts with breaking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge. Make: Legrand (Cat No: 669718) or equivalent from list of make as approved by GE.
MCCB of 4 pole 125 Amps 415 Volts with breaking capacity 25 KA complete with thermal and magnetic release all as specified and directed by Engr-in-charge. Make: Legrand (Cat No: 669719) or equivalent from list of make as approved by GE.
MCCB of 4 pole 160 Amps adjustable type, 415 Volts, with breaking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge. Make: Legrand (Cat No: 669070) or equivalent from list of make as approved by GE.
MCCB of 4 pole 200 Amps adjustable type, 415 Volts, with breaking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge. Make: Legrand (Cat No: 669071) or equivalent from list of make as approved by GE.
MCCB of 4 pole 250 Amps adjustable type, 415 Volts, with breaking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge. Make: Legrand (Cat No: 669072) or equivalent from list of make as approved by GE.
MCCB of 4 pole 400 Amps adjustable type, 415 Volts, with breaking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge. Make: Legrand (Cat No: 667655) or equivalent from list of make as approved by GE.
MCCB of 4 pole 630 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release all as specified and directed by Engr-in-charge. Make: Legrand (Cat No: 667657) or equivalent from list of make as approved by GE.
Voltmeter, digital type, as per existing make and compatibility
Ammeter, digital type, as per existing make and compatibility
PVC Insulated, Single core, copper conductor cable 4 Sqmm size
PVC Insulated, Single core, copper conductor cable 6 Sqmm size
PVC Insulated, Single core, copper conductor cable 10 Sqmm size
ACB in the existing panel air circuit breaker of rating 800A, 4 pole, 50 KA, MDO microprocessor based SR 18G release, fully interlocked casette door, automatic saftey shutters, mechanical ON & OFF indicators, closing coil and shunt trip coil voltage 220-250 V AC and as per existing CT ratio ACB ensures validity of short circuit tests, service/test isolated position with indicators complete all as specified and as directed by Engineer in Charge.
ACB in the existing panel air circuit breaker of rating 1600A, 4 pole, 50 KA, MDO microprocessor based SR 18G release, fully interlocked casette door, automatic saftey shutters, mechanical ON & OFF indicators, closing coil and shunt trip coil voltage 220-250 V AC and as per existing CT ratio ACB ensures validity of short circuit tests , service/test isolated position with indicators, all as specified and as directed by Engineer in Charge.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard / dense soil complete all as specified and directed by Engineer in Charge.
Excavation in trenches n.exc. 1.5 mtr in wide and exc. 1.5 mtr but n. exc 3.0 m in depth and getting out in hard / dense soil complete all as specified and directed by Engineer in Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engineer in Charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer in Charge.
Material & Labour for sand/fine dust cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge. (Note : punning thickness of 18 cm shall only be measured for payment)
Supplying and laying precast concrete LT cable cover, class LV, type flat , size 250mm x 150mm x 40mm complete for protection of underground cable all as specified and directed.
Supply, stringing, streaching and binding in replacement with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections etc complete all as specified & directed by Engineer in Charge.
Material & Labour for Dismantling of ACSR conductor from LT pole and shifting of street/security light fittings to the position as directed on any type of pole complete all as specified and directed by Engineer in Charge. Note: Dismantling of ACSR should be done after connection of LT UG Cable and Sch of Credit will be measired against cable.
Material & Labour for Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed by Engineer in Charge.
Supply, Laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed by Engineer in Charge of following size:-
10 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 4 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
Note for Item No 17.01 to 17.08: (i) During earth work for laying of cable, any damage to the existing services shall be made serviceable by the contractor without any extra cost within 24 hrs. (ii) Sch of credit for cable has not been considered for complete qty because conversion of ACSR will be done at some places and credit should be of ACSR. (iii) Contracor should visit the site before quoting the rate for understaniding the scope of work.
Supply & Fix tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed by Engineer in charge for the following bores :-
100 mm bore
80 mm bore
50 mm bore
Material & Labour for cutting through existing bituminous road /PCC/floor/ along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finishes complete all as specified and as directed by Engineer in charge. Note: GI Pipe shall be measured and paid seperately under respective item of this schedule.
Supply and errect in true vertical position steel tubular swaged poles in replacement complete with MS base plate of 6mm of size 300mm X300mm finial taper plug,pole cap,bolts,nuts and washers screws,pole made out of ERW MS tubing as per IS-1161 and pole shall be as per IS-2713 Part II type 410 SP-31 (9.00 Mtrs Long) complete including one coat of red oxide zinc chrome primer and two coats of Aluminium paint for exposed surfaces and two coats of black bitumenous paint for portion embedded in concrete complete including dismantling old pole and removing from site all as specified and as directed by Engineer in Charge. Note: Excavation and earth work, PCC in foundation /plinth block/coping shall be measured and paid for separately.
Material & Labour for Plain Cement Concrete 1 : 4 : 8 Type D-2 using 40 mm graded aggregate as in foundation for pole including necessary form work complete all as specified and directed by Engineer in Charge.
Material & Labour for Plainr Cement Concrete 1 : 2 : 4 type B-1 using 20 mm graded aggregate as in foundation ,filling and mass concrete necessary form work all as specified and directed by Engineer in Charge.
Supply & Fix in repair /replacement of street light juction box of size 200mm x 160mm x 98mm, top hing door type, complete with 4 way connector - 01 No, 6 Amps SP MCB - 01 No, fixing on street/security light pole of any type with suitable MS clamp, nut, bolts, washers and cable gland for each connection complete all as specified and as directed at site by Engineer in Charge. Make of box : HENSEL/Sintex or equivalent as approved by GE
Material & Labour for spreading evenly stone aggregate of size 40 mm size in the Sub Stn area complete all as directed by Eng-in-Charge at site.
Material & Labour for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed by Engineer in charge.
Material & Labour for disconnecting old unsv main switch any type and supply & fixing, connecting to existing cable with new MCCB, 4 pole, 63 Amps, 25 KA, including sheet metal enclosure duly powder coated fixed on existing angle iron stand with nuts, botls etc all as specified and as directed by Engr-in-Charge at site. Make: Legrand (Cat No: 669716) or equivalent from list of make as approved by GE.
All as per Item No 26.00 Above but MCCB, 4 pole, 100 Amps, 25 KA -ditto- Make: Legrand (Cat No: 669718) or equivalent from list of make as approved by GE.
All as per Item No 26.00 Above but MCCB, 4 pole, 125 Amps, 25 KA -ditto- Make: Legrand (Cat No: 669719) or equivalent from list of make as approved by GE.
All as per Item No 26.00 Above but MCCB, 4 pole, 160 Amps, 36 KA -ditto- Make: Legrand (Cat No: 669070) or equivalent from list of make as approved by GE.
All as per Item No 26.00 Above but MCCB, 4 pole, 200 Amps, 36 KA -ditto- Make: Legrand (Cat No: 669071) or equivalent from list of make as approved by GE.
All as per Item No 26.00 Above but MCCB, 4 pole, 250 Amps, 36 KA -ditto- Make: Legrand (Cat No: 669072) or equivalent from list of make as approved by GE.
Supply & Fix Gate Light fittings, decorative type, LED, 40Watt, all including fixing material on gate posts complete and connected to nearest electric pole complete all as specified and as directed by Engineer in Charge. Make: Crompton (Cat No: LPTO-40-CDL ) or equivalent from list of make as approved by GE.
Supply & Fix Energy efficient LED street light fittings, 90 Watt, die-cast aluminium body with power LED and dirver with IP66 protection and 10KV built-in-surge protection device complete all as specified and as directed by Engineer in Charge. Make: Crompton (Cat No: LSTP-90-CDL-M ) or equivalent from list of make as approved by GE.
Supply & Fix street light bracket made out of GI tubing 40mm bore, 1.5 metre long bent to shape as directed, including suitable MS clamp with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED bollard light fittings, LED 10Watt, all including fixing material and earth work complete and connected to nearest electric pole complete all as specified and as directed by Engineer in Charge. Make: Crompton (Cat No: LBLSN-10-CDL ) or equivalent from list of make as approved by GE.
Supply & Fix decorative Post top light fittings suitable for 10 watt LED bulb (B22 base), with stand post made out of GI pipe 40mm dia, 1 M long, duly fixed and connecting electric connection all as specified and as directed at site by Engineer in Charge. Make: Havells (Cat No: LHFXBON1TN5Q014) or equivalent from list of make as approved by GE
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections one twin core cable flat or circular of size 6 Sqmm all as specified and as directed by Engineer in Charge.
Supply and fixing in repair LED flood light fittings for area lighting 150 Watt made out of pressure dia cast aluminium housing with IP66 protection and 10 KV SPD all as specified and as directed by Engineer in Charge. Make: Crompton Cat No CFS-501-150-57-60D-SL-GL-NGG or equivalent from List of Make as approved by GE.
metro electrical services
M/S. Niksun Electro-Infra Private Limited
M/S. OM ENTERPRISES
T.H.ASSOCIATES
Sahara Engineers
Adinath Technical Services
Mahindra Electric Stores
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .