Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹21.4 L+₹55,151.50 (2.65%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹21.9 L+₹1.0 L (5.01%)Rejected-Finance | L3 | Rejected-Finance Rejected |
Tender Value
₹33.3 L
EMD Value
₹66,600
Closing Date
16 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
EXECUTION OF CERTAIN SANCTIONED WORKS UNDER THE AREA OF AGE B/RI AGE B/RII AGE E/MI OF GE AF SUBROTO PARK
2024_MES_650583_1
GE/SP/ TOKEN-65/2023-24
Open Tender
Civil Works
Item Rate
120 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹66,600
Yes
14 Sept 2024
20 Apr 2024
18 May 2024
20 Apr 2024
16 May 2024
4 May 2024
Amount
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc and removing the debries outside the MOD land complete all as specified and as directed by Engr -in - Charge.
M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in 1:4 cement mortar including dismentling complete all as specified and as directed by Engr-In-Charge.
M&L for rendering CM (1:6) 15 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M & L rendering 10mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement complete all as specified and directed by Engr In Charge.
M&L for preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 3mm thick putty on walls complete all as specified and directed by Engr-In-Charge.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper with 3mm thick elastomeric wall care putty on walls, including repairing of pot holes and cracks with putty, including plaster where it required complete all as specified and directed by Engr-in-Charge.
M&L for preparation on old plastered or unplatered surfaces of walls and applying two coat of exterior Apex/weather coat over a coat of primer any tint (colour as approved by GE) over putty including preparation of surface of wall, band/chajja/balcony up to four storey height building complete all as specified and dircted by Engineer in charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed by Engr In Charge.
All as per Item N0 8 here in before but not exc 1.5 Sqm .
S&F aluminium powder coated any colour (minimum thickness of powder coating 50 micron) for doors, windows, partician, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium powder coated an (minimum thickness of powder coating 50 micron) as in window and ventilator shutters, sliding type three track, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber packing, anodised aluminum snap beading screws etc complete all as specified and as directed by Engr-In-Charge.
S&F for powder coated aluminium doors shutters,( thickness of powder coating not less than 50 micron) aluminium section weighing 0.55 kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing , handels 2 Nos in each door , hinges, anodised aluminium snap beading screws etc. complete all aspecified and directed by engr-In-Charge.
S&F 12mm thick particle board prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc.Complete all as specified and directed by Engr-in-Charge.
S&F brass body Mortice lock, vertical type,size 100 mm 4 lever, incl escutcheon plate and two No keys fixed complete all as specified and directed by Engr-in-Charge.
S&F in repair aluminium deco grills confirming to DG-104 grade all as specified and directed by Engr-In-Charge.
S & F in repair aluminium extruded section door closer hydraulically operated designation No-03, universal type, suitable for door shutters of 851 to 1000mm width and of weight of 61 to 80 Kg complete all as specified and directed by Engr In Charge.
S & F in repair 140mm long floor door stopper of Almn alloy body and tongue with hard drawn steel spring complete all as specified and directed by Engr In Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.complete all as specified and directed by Engr In Charge.
M&L Glazed ceramic coloured tiles in vertical surface 300X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl back plaster 10 mm thick in cm 1:4 & including 100mm thick cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes complete all as specified and directed by Engr In Charge.
M&L Virified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and as directed by Engr-In-Charge.
All as per Item No 21 here in before but on vertical surface of wall such as skirting/dado including 10mm thick cement plaster (1:4) as in backing coat of tiles.
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE all as per , Everest Ceiling grid system 'Regular T-2430' or its equivalent make of "'Ramco, Charminar/Armstrong'' at any height including dismantling complete all as specified and as directed by Engr-In-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling of asbastos cement (corrugated or semi corrugated) sheeting in roof covering as specified and directed by Engr-in-charge.
S&F steel/work in tubular truses, purlins, rafters, struts, vertical members and similar work including special shape washers complete using ERW or induction butt welded tubes conforming to IS-1161-1979, grade St-240, Mild Steel plates complete all as specified and directed by Engr-in-charge.
M&L for preparation of new steel surfaces of any description, not other wise described, over 10 cm width or girth and applying two coats synthetic enamel paint over a coats of red oxide primer as specified and directed by Engr-in-charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by Engr-in-charge.
All as per item No 27 here in before but 20mm bore size
S&F for 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
All as per item No 29 here in before but 20mm bore size
Dismantling water tanks exc 500 but not exc 1000 ltrs capasity and removing to store complete all as specified and directed by Engr In Charge.
S&F Rotational moulded polyethylene 1000 Ltr water storage tanks as per IS (cylindrical vertical with closed top) hoisted and fixed in position including necessary fittings complete all as specified and as directed by Engr-in-Charge.
S &F for 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe orr brass errule and fixed complete all as specified and directed by Engr In Charge.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engr In Charge.
S&F for Stack clamps for 75mm dia PVC pipe made out of flat iron 50mm x 5mm size and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof complete all as complete all as specified and directed by Engr In Charge.
S&F Stack clamps for 110mm dia PVC pipe made out of flat iron 50mm x 5mm size and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as per complete all as specified and directed by Engr In Charge.
S&F for PVC SWR bends of size110 mm complete all as specified and directed by Engr In Charge.
S&F PVC SWR bends of size 75 mm complete all as specified and directed by Engr In Charge.
S&F for PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors complete all as specified and directed by Engr In Charge.
All as per Item No 39 here in before but 75 mm dia.
S&F for PVC SWR Junction piece of size 75 mm provided with access door equal or unequal complete all as specified and directed by Engr In Charge.
S&F for 110 mm PVC SWR Junction single (Single T) of size 110mm dia provided with access door complete all as specified and directed by Engr In Charge.
S&F in repairs Vitreous China wash basin white of size 630x450mm including all fitting like iron angle, CP pillar tab swan neck, pvc connection, CP waste coupling 32mm size half threaded with 130mm height complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs 15mm CP bib tap fancy type copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe etc complete all as specified and directed by Engr In Charge.
S & F in repairs CP Soap dish complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 15mm bore two way angle valve chromium plated with wall flange and fancy type high pressure screwed down with CP flange complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PTMT grating round of 100mm dia (Minimum wt 50gms) complete all as specified and as directed by Engineer-in-Charge.
S&F in reapirs PTMT grating with waste hole (Minimum wt 100 gms) complete all as specified and as directed by Engineer-in-Charge.
S&F in repair stainless steel sink without drainage board made out of 1mm thick sheet for kitchen or laboratory with plug, washer, waste pipe etc including cast iron brackets, connecting union over all size 915mm X 460mm with bowl size 410mm X 330mm X 160mm complete all as specified and directed by Engr In Charge.
S & F for repair 15 mm bore brass CP sink mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engr In Charge.
S&F in repairs stainless plate rack of size 900mmx750mmx250mm depth size made out of 0.75mm thick sheet complete all as specified and directed by Engr In Charge.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed
Dismantling of aluminium door, partition, window & ventilator including all necessary fittings complete all as specified and as directed
S&F Aluminium( extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as directed and specified.
S&F for double action floor spring hydraulically regulated mode lap of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed to shutter complete all as specified and directed by Engr-in-Charge.
M&L for scratch free vitrified ceramic tiles 10mm thick (square or rectangular) polished area of each tile exceeding 0.42 sqm but n. exc 1.00 sqm ,in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
S&F in repair vertical roller blinds made out of nylon cloth of any colour as approved including hanging arrangement rollers etc complete as specified and directed by Engineer in charge.
M &L for PVC profile for wall panelling colour / shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square ( size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls and including dismentling complete all as specified and directed by Engr-in-Charge.
M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid ceramic coloured / light shade, premium quality tiles (300mmx300mm/400mmx400mm)x7 mm thick as decided by EIC in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in cement mortar 1:6 complete all as specified and directed by Engr-In-Charge.
M&L for PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregates) of 25 mm thick as in levelling course ,finished surfaces even and rough to receive floor finish complete all as specified and directed.
M&L for glazed ceramic coloured tiles/ light shade, premium quality tiles including designer tiles of size 350mm x 250mm x 7mm/450mm x 350mm x 7mm thick or as decided by EIC over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces or as in highlighter, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-In-Charge.
M&L for Vitrified coloured tiles (600mmx600mm)x10mm thick in floors/Skirting etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in cement mortor 1:6 complete all as specifed and directed.
M & L for complete removing existing treatment, old decorated surfaces of walls/Ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. including cornices, pilasters etc. (Plastered or unplastered surfaces) and applying two coats of exterior plastic emulsion paint (Coloured as directed by EIC), over 2mm thick wall care putty , complete all as per manufacturers instructions and as directed by Engineer-in-Charge.
M&L for complete removing existing treatment old/new surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance 1st quality exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including change of existing colour if required complete all as specified and as directed by Engineer-in-Charge. Note:- (a) Work will executed upto 5th floor. (b) The rate is inclusive for scaffolding or reqd necessary arrangement for multi-storey bldg painting.
S&F vitreous china counter top wash hand basin of size 45cmx37cmx14.5cm white, complete all as specified and as directed by Engineer-in-Charge.
S&F for 15mm bore dia fancy type pillar taps cast copper alloy chromium plated screwed down high pressure with or with out littred hot or cold with long screwed shanks and flynuts screwed for iron pipe complete all as specified and directed.
S&F vitreous china wash down water closet pan (pedestal pattern, one piece) white, size 65.5cmx38.5cmx76.5cm with integrated flushing cistern, including making good complete all as specified and directed.
S&F 32 mm dia brass chromium plated bottle trap complete all as specified and as directed by Engineer-in-Charge.
S&F for PVC connection 15mm dia and 600mm long complete all as specified and directed.
S&F in repair CP stop/angle valves, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type) with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore complete all as specified and directed by Engr-In-Charge.
S&F fancy type mirror of 8 to 10 mm thick glossy glass decorative/ designer type, any size and shape bevelled edges all-round as decided by EIC, wall mounted mirror complete all as specified and directed by Engineer-in-Charge.
S&F for CP towel rail of 15mm dia with hook 600mm long complete all as specified and directed by Engr-In-Charge.
S &F Toilet paper holder with flat recessed type stainless steel complete all as specified and directed by Engr-In-Charge.
S&F CP bib taps long body , cast copper alloy, fancy type with with wall flange, chromium plated, screwed down to iron pipes or for brass ferrule of 15 mm bore complete all as specified and directed by Engr-In-Charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified
S&F 15mm dia CP jet with CP flexible pipe 90cm long incl necessary fittings complete all as specified and directed .
S&F liquid soap dispenser with stainless steel metallic bottle complete, all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC (SWR) pipe single socketed any length with rubber ring joints fixed on walls or laid in trenches , in floor or in under sunken system, including taking down complete all as specified and directed. NOTE :- Rate includes core cuttings of RCC slab/cutting holes in wall and all fittings as branch piece/ junction , single/ double/ triple , equal/ unequal.
S&F 150mmx150mm floor drain with cockroach trap buld with 1mm thick 304 grade stainless steel with complete set ( Frame, drain cover, outer cup, inner cup etc. including jointing with solvent cement) complete all as specified and directed.
M&L for 20mm thick prepolished Granite slab any colour/quality as approved by GE on top of platform, WHB counter and similar work including cutting rounding on edges etc machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding, polishing and cutting grooves for anti skid porpose complete all as specified and directed by Engr-In-Charge.
M & L for providing reinforced cement concrete 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) as in copping, shelves roof kerbs or mud stops, rounded or chamfered edges, including necessary formwork complete all as specified.
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and blinding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips. Complete all as specified and directed.
S&F for powder coated (minimum thickness of powder coating 50 micron) aluminum anodized three track sliding window with two or more shutter with 5 mm thick plane glass, one shutter of stainless steel mosquito proofing with good quality bearing ,handle lock,etc rubber beading and glazing clips etc using following sections as given in 'JINDAL' catalogue etc as specified as per manufacturer instructions with the following size and directed by Engineer-in-Charge. Note : (a) Rate included sliding window section, Glass and Wire mesh. (b) Opening will be measured for payment purpose excluding aluminum frame.
S & F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
Supply and fixing 4.8 mm thick ordianary quality sheet glass exe 0.5 sqm in each pane of glazing with oil putty /beading etc all as specified and directed by Engineer-in-Charge.
M&L prelaminated particle board 12mm thick interior grade prelaminated both side with decorative choice lamination and other side balancing white lamination with screws to timber frame work complete all as specified and directed by Engr-In-Charge.
Surface Excavation n exc 30 cm deep and averaging 15 cm deep and getting out Hard / dense soil complete all as specified and directed.
M&L for 75 mm thick PCC type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L for 60mm thick, M-30 Grade Machine pressed precast concrete pre-painted interlocking paver block any shape and size casted in plastic moulds and compated on vibratory table confirming to IS 15658-2006 with grey cement and pigment complete all as specified and directed.
M&L for Providing, cement concrete in roof/side kerbs or mud stops, rounded or chamfered on edges making good disturbed surface of ground complete all as specified and directed.
M&L for two coat of terakota paint on floor incl preparation of newly or previously untreated surfaces of any description, over 10cm width or girth, not otherwise described complete all as specified and directed by Engineer-in-charge
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc and removing derbies out site MOD land complete all as specified and directed .
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power) complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and acessories concealed in wall / ceiling or surface conduit wiring on ceiling /wall terminated in flush metal box alongwith outer cover plate for mounting modular switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size for one light point controlled by one switch one way.
All as per item No 98 here in before but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
All as per item No 98 here in before but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 98 here in before but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size.
S&F switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
S&F switch piano, flush type single pole, one way, 15 Amps, 240 volts all as specified and directed at site.
S&F socket outlet 5 pin 5 Amps all as specified and directed at site.
S&F socket 16 Amps, 2 in 1, flush type all as specified and directed at site.
Supply and fixing ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
Taking down LED Light of any size Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED lights fitting 1x 20W 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F wall mounting fan 250 mm sweep 230 Volt, rated motor speed not more than 1200 RPM, pull cord type 3 step regulator, pull cord type oscillation and mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified.
S&F Exhaust fan steel body AC single 300 mm sweep 230 Volt, 1400 RPM with louver including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling fan heavy duty 1200 mm sweep, 230 Volt including necessary fixing arrangement for proper fixing/hanging as per site requirement complete all as specified and as directed by Engineer-in-Charge.
M & L for submain wiring with two run of single core 10.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specifiedand directed. Note :- 2 Runs of 10.0 Sqmm single core and one run of 10.0 sqmm single core cable for earth continuity conductor with one Run of Non metalic PVC conduit consider as one unit for payment purpose.
M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed- 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable for earth continuity conductor with one Run of Non metalic PVC conduit consider as one unit for payment purpose.
Supply and fixing load line vertical distribution board 'G' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'G' frame MCCB of 250 Amps =01 No and MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing 415V 10KA 'C' curve TPN 16 To 32 AMP miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core comlete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MS cable tray Mild steel of size 300x50MM perforated cable tray for industrai use of size 3MM thicker rectangular with polished finishing and galvonaised coating with all connecting accessories requied at site with proper fixing/finishing completed all as specified and as directed by Engineer-in-Charge. .
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 250 Amps, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed by Engineer-in-charge.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
M&L in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB DB single pole and neutral with two pin and earth plug and socket 20 Amps complete with one SP MCB 20 Amps fixed flush in wall including cutting chases in wall for fixing DB and making good the distrubed wall surface to match with existing specification
S & F Modular Socket, 6A- 3 pin combined 2 module, suitable for 240 volt AC complete all as specified and directed by Engineer-in-Charge
S & F modular switch 1 way 16A, 1 modules suitable for 240 volt AC complete all as specified and directed by Engineer-in-Charge
S & F Modular Socket, 16A- 3 pin combined 2 module, suitable for 240 volt AC complete all as specified and directed by Engineer-in-Charge
Supply and fix white cover plate with frame, 3 module complete all as specified and directed by Engineer-in-Charge
Supply and fix white cover plate with frame, 4 module complete all as specified and directed by Engineer-in-Charge
Supply and fix white cover plate with frame, 8 module complete all as specified and directed by Engineer-in-Charge
Supply and fix modular metal flux box, 3 module complete all as specified and directed by Engineer-in-Charge
Supply and fix modular metal flux box, 4 module complete all as specified and directed by Engineer-in-Charge
Supply and fix modular metal flux box, 8 module complete all as specified and directed by Engineer-in-Charge
Taking down unsv SP/SPN MCBs of any capacities from the MCCBs, DBs/ MCB, DBs after disconnecting the electric supply, complete all as specified
M/S MG GROUP
GIR RAJ BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .