Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.0 LAccepted-AOC AT MQ 49 BODIYA BASTI KATHARA BOKARO JHARKHAND 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | 1 | Accepted-AOC Accepted | |
| 2 | Rejected-Technical MAIN ROAD KATHARA BOKARO 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Not Evaluated as not L1 | |
| 3 | Rejected-Technical GAYATRI COLONY KATHARA | KATHARA | JHARKHAND | - | Rejected-Technical Not Evaluated as not L1 |
Tender Value
Refer Docs
EMD Value
₹3,800
Closing Date
15 Apr 2023, 4:00 pmClosed
Staff Officer ENM
Office of Staff Officer EnM Kathara Area
Annual Mainte. Contract (AMC) basis of rectification of 3.3KV and 440V OH line, erection of pole, stay set, brackets, pin insulators and shackle insulators etc. from back side Executive hostel to G.M.Office, Rest House campus, Area
2023_CCL_276959_1
GM(KTA)/SOEnM/ETen/22-23/60
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Kathara Area
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,800
17 Jun 2023
3 Apr 2023
17 Apr 2023
4 Apr 2023
15 Apr 2023
4 Apr 2023
4 Apr 2023 - 12 Apr 2023
Amount
Erection of metallic pole /steel tubudan pile of length above qntr and up to 10 mtr in cement concrete 1: 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required
Supplying & Erection of stay set complete galvanized with 19/20mm dia x 1.8meters long stay rod, anchor plate of size 45cm x7.5 mm thimble, stay clamp,turn buckle (20mm x 60mm), 714.00 mm dia G.I stay wire and strain insulator etc. in cement concrete 1:3:6(1 cement : 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/2, 11mm to 7/3.00 diameter 7 span X 4 wire X35Mtr= 980 M, 4 span X 30 mtrs X 2 wire = 240 M, 8 span X 30 mtrs X 2 wire = 480 M, = 1700 M and including 5% lapping & binding 85 M = 1785 mtrs, x0.214 kg/mtr= 381.99kg
Suppling an erection of galvanized D iron clamps complete with shackles insulator (100mm X 110mm) GI bolts and nuts washers coach screw etc as required.
Suppling of channel iron (75mm X 40mm X 6mm 7.14kg per mtr) crass am far 2 wire O/H line complete with clamps bolts nuts & washers etc including dulling of hdes for insulator pin etc as per drawing and painting with primer and finished painters as required.
Suppling of channel iron (75mm X 40mm X 6mm 7.14kg per mtr) crass am far 2 wire O/H line complete with clamps bolts nuts & washers etc including dulling of hdes for insulator pin etc as per drawing and painting with primer and finished painters as required.
Dismantling of pole/street hight standard/ Strunt embedded in cement concrete foundation et as required
Suppying and laying 6 SWG 25mmx6mm G I strip at 0.50 metre below ground as strip earth electrode including connection/ terminating with nuts, bolt, spring, washer etc. as required.(jointing shal be done by overlapping with 2 sets of brass nuts bolt & spring washer spaced at 50mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering
Earthing with G I earth plate 600mm x 600mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having lacking arrangement and watering pipe of 2.7 mtr. long etc. with charcoal/coke and salt as required.
Supply and erection of 100mm X 60mm pin insulator complete with G.I spindles and nuts etc as required.
Pole painting of old poles with Red oxide primer (11nos)
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) Details ofcost for 1 cum.Pole Strenthing of11 nos pole (0.70x0.70x0.90 )= 0 .441 x 11 Nos =4.851
Providing &fixing of maintainless earth resistance of ratty pit copper bonded tube 3000mm lenght,76mm diameter and advanced ground enhancing compound -02 bags ISO Certified with installation complete set ,as required.Details of cost for one Set
Cutting and trimming of trees branches bushes /shrubs along with different over head lines up to a distance of 50 m outside the periphery of the area cleared up to a distance of 50 m outside the periphery of the area cleared.Back side at G M Office 5 spanx35Mx4M=700 Sqm,Area Hospital Kathara 2 span x 30Mx4M=240Sqm,Officer club 8 span x30Mx4M=960Sqm,Rest house 4 span 20Mx3M=240Sqm G Total=2140 Sqm
Total impact of GST for the purpose of CTC
M/S P. L. CONSTRUCTION
M/S VINEET ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_286721.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .