Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
26 Nov 2020, 6:00 pmClosed
Commandant
Commandant Base Hospital Lucknow
For supply of medical stores to Base Hospital Lucknow FY 2020-21
2020_ARMY_392753_1
BH/MS/PC/DGLP/ECHS/RE22/20-21
Open Tender
Medical Equipments/Waste
Buy
30 days
Base Hospital Lucknow
Please refer to Tender Documents
6 documents required · 6 mandatory
₹0
₹40,000
Yes
23 Dec 2020
5 Nov 2020
27 Nov 2020
5 Nov 2020
26 Nov 2020
5 Nov 2020
5 Nov 2020 - 26 Nov 2020
Vertical Isolation Drape for Hip surgery of clear transparent waterproof material. Adhesive Incise Area iodophor impregnated approximately 40cm x 75cm, Fluid Collection Pouch with Suction Port, Attachable Instrument Pouch, Tube Holders, Central Release Tape Strip for Horizontal Rod Attachment . 10% variation acceptable. Up to 10% variation in size acceptable.
SYNTHETIC BONE GRAFT CUBES/CONES-sterile packed. USFDA/ CE(EU)/IC Med approved. Size 8-12mm cones/cubes
SYNTHETIC BONE GRAFT WEDGES-sterile packed. USFDA/ CE(EU)/IC Med approved.size 6 x 12mm wedges
3.5mm DISTAL TIBIAL MEDIAL LOCKING PLATES with at least 6 holes in head and 9/10 holes for shaft with 8 x locking and 2 x cortical screws. variable angle, Complete construct. Titanium. Implants should be USFDA/ CE(EU)/IC Med certified.
3.5mm DISTAL TIBIAL MEDIAL LOCKING PLATES with at least 6 holes in head and 11/12 holes for shaft with 8 x locking and 2 x cortical screws. variable angle, Complete construct. Titanium. Implants should be USFDA/ CE(EU)/IC Med certified.
3.5mm DISTAL TIBIAL MEDIAL LOCKING PLATES with at least 6 holes in head and 13/14 holes for shaft with 8 x locking and 2 x cortical screws. variable angle, Complete construct. Titanium. Implants should be USFDA/ CE(EU)/IC Med certified.
3.5mm ANTEROLATERAL DISTAL TIBIAL LOCKING COMPRESSION PLATES with 4-5 holes for subchondral bone, 8/9 holes for metaphysis/shaft with 10 x 3.5mm locking and 2 x 3.5mm cortical screws. Complete construct. Implants should be USFDA/ CE(EU)/IC Med certified.
3.5mm ANTEROLATERAL DISTAL TIBIAL LOCKING COMPRESSION PLATES with 4-5 holes for subchondral bone, 10/11 holes for metaphysis/shaft with 10 x 3.5mm locking and 2 x 3.5mm cortical screws. Complete construct. Implants should be USFDA/ CE(EU)/IC Med certified.
3.5mm ANTEROLATERAL DISTAL TIBIAL LOCKING COMPRESSION PLATES with 4-5 holes for subchondral bone, 12/13 holes for metaphysis/shaft with 10 x 3.5mm locking and 2 x 3.5mm cortical screws. Complete construct. Implants should be USFDA/ CE(EU)/IC Med certified.
3.5mm low profile locking Pelvic reconstruction plates (SS) 10 holes curved with 10 x cortical/cancellous screws complete construct. Implants should be USFDA/ CE(EU)/IC Med certified.
3.5mm low profile locking Pelvic reconstruction plates(SS) 12 holes curved with 12 x cortical/cancellous screws complete construct. Implants should be USFDA/ CE(EU)/IC Med certified.
3.5mm low profile locking Pelvic reconstruction plates(SS) 14 holes curved with 14 x cortical/cancellous screws complete construct. Implants should be USFDA/ CE(EU)/IC Med certified.
3.5MM T-Plate (Buttress plate), right angled, 4 transverse and 2/3 holes along long axis with 5 self tapping cortical screws, complete construct Titanium.
3.5MM T-Plate (Buttress plate), right angled, 4 transverse and 4/5 holes along long axis with 6 self tapping cortical screws, complete construct Titanium.
3.5MM T-Plate (Buttress plate), right angled, 4 transverse and 6/7 holes along long axis with 7 self tapping cortical screws, complete construct Titanium.
3.5MM T-Plate(Buttress plate), oblique angled, 4 transverse and 2/3 holes along long axis with 5 self tapping cortical screws, complete construct Titanium.
3.5MM T-Plate (Buttress plate), oblique angled, 4 transverse and 4/5 holes along long axis with 6 self tapping cortical screws, complete construct Titanium.
3.5MM T-Plate (Buttress plate), oblique angled, 4 transverse and 6/7 holes along long axis with 7 self tapping cortical screws, complete construct Titanium.
Disposable Sterile suction tube with a reservoir and Filter
Suture Post Titanium 6.5mm x 25/30mm (Sterile Packed)
Trochnateric stabilization Plate (TSP), Stainless steel, for use over DHS Side plate.(Large/medium/small)
Triclosan coated Braided dyed Polyglactin for Orthopaedic surgery size no 2, 90 cm long thread with taper cut heavy needle. USFDA/ CE(EU)/IC Med certified.
Post operative sterile adhesive porous port dressing with absorbent pad and confirmative fixative layer 5 cm x 5 cm
Calibrated Cannulated 4 fluted Drill Bits H.S.S. (175-200mm Length) 2.5 mm, 3 or 4 faced chuck end. 316Lvm stainless steel.
Olive wire for ilizarov bayonet tip,3 faced chuck end, 1.8x 370mm.316Lvm stainless steel.
Wire (Kirschner) 15 cm long X 1.5 mm dia. 316Lvm stainless steel.
Wire (Kirschner) 15 cm long X 2.0 mm dia. 316Lvm stainless steel.
Bone graft substitute Paste in prefilled syringe, sterile packed 5 ml
Bone graft substitute Paste in prefilled syringe, sterile packed 10 ml
Disposable Tie-on Face mask (4 ply) with fog free fluid shield visor (Compliant with ISO 22609 & EN14683 standards)
NEW LIFE MEDICOS
KOHLI DISTRIBUTORS
Navyug Enterprises
Saraswati Associates
SHINE SURGICALS PVT LTD
AHUJASONS SURGICALS
Prakash Medicos
madhulika associates pharma services
SHINE SURGICALS PVT LTD
NEW LIFE MEDICOS
Saraswati Associates
SHI MEDIWEAR PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .