Loading…
Loading…
Tender Value
₹20.2 L
EMD Value
₹40,475
Closing Date
2 Sept 2026, 12:00 pm5d left
SACHIN YADAV
Municipal Corporation Gurugram
Supply and Erection of street light fitting at MDI chowk Flyover from sector 14 to sector 17 under ward 25 zone 4 MCG.
2026_HRY_543606_1
20260412AC3D F273 4F98 AC85 DCD56A16E440285ULB
Open Tender
Civil Works
Works
120 days
Gurugram
Supply and Erection of street light fitting at MDI chowk Flyover from sector 14 to sector 17 under ward 25 zone 4 MCG.
2 documents required · 2 mandatory
₹1,180
₹40,475
Yes
26 Aug 2026
26 Aug 2026
2 Sept 2026
26 Aug 2026
2 Sept 2026
26 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Supply and Erection of street light fitting at MDI chowk Flyover from sector 14 to sector 17 under ward 25 zone 4 MCG. | - | - | - | - |
| 3 | Supply and erection of 2.5 sqmm 3 core unard FRLS PVC insulated ISI Marked copper conductor cable complete as per entire satisfication of engineer in charge.Make RR / Havells / Polycab/Grandley. 2.5 Sq. mm 3 Core Cable. | 336 | Metre | - | - |
| 4 | Restoring the road cut, in level with the existing road surface, including preparation of subgrade laying and relaying of soiling and laying and consolidation of wearing coats to water bound macadam specification and laying 20mm thick premix carpet, on top including cost of tack and sealcoat complete in all respects... | 100 | Sqm | - | - |
| 5 | Providing trench less cuttting by Hydraulic Drilling Device boring/ Manual OR through some suitable alternate method with insertion of HDPE Pipe including supply, Delivery of HDPE pipe at work site and laying of 50mm internal diameter HDPE pipe inside road for road corssing of cable by Hydraulic Drilling Device without opening of the road top surface, laid at a depth of at least 900mm below the road surface from the feeding point to the feeder pillar box in median (OR) from feeder pillar to respective street light pole including cost of all accessories for road crossing for laying of cables.. | 100 | Metre | - | - |
| 6 | Erection Testing and commissioning of Three phase CCMS panel petty material required for installation of ccms panel i.e clamp,nut and bolts,thimble ,wire etc complete in all material required for installation on PCC pole or Pedstal. complete in all material required for installation on PCC pole or Pedstal. | 2 | Each | - | - |
| 7 | Providing and fixing of 4G/5G Sim Card and recharse fees per month for street lights CCMS panel Compelte in all respect required for proper operation of CCMS panel. 500 Nos x 60 | 24 | Each | - | - |
| 8 | Defect liablity period for Replacement of burnt/faulty cables of various sizes 10x3core,e and 25X 4 core cable SPMCB, EPMCB,contractor, wiring and other item required for CCMS panel and Installation of material supplied by the M/s Surya Co. as per rate contract term and Condition i.e SPMCB, EPMCB, contractor, wiring etc and other item required for CCMS panel and maintaining the connectivity of CCMS panel with the GMDA/other portal through sim and removing of fault in ccms
panel for 1st and 2nd year free of cost | 1 | Each | - | - |
| 9 | HSR No 23.28.12.14 .Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 90watt | 56 | Each | - | - |
| 10 | Supply and erection of Aluminum painted wall mounting single arm bracket made out of 42 mm OD Dia 1.5 mtr long with base plate of 150X150x8 Memnon existing flyover wall up to height of 9 mtr including the cost of 4 No fashner and other petty material required for installation complete in all respect | 56 | Nos. | - | - |
| 11 | S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 , on existing flyover wall up to the Hight of 9 mtr wall including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. | 2,000 | Per Metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
BOQ_623111.xls
BOQ • 0.28 MB
AD0173979.pdf
Additional Documents • 0.99 MB
OT0173979.pdf
Other Document • 0.99 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].