Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance GROUND FLOOR ASHFAQ HUSSAIN AL ABASS A S RELIEF TRUST BUILDING KARAN NAGAR SRINAGAR 91495 SRINAGAR JAMMU AND KASHMIR 190010 | SRINAGAR | JAMMU AND KASHMIR | 190010 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹98 L
EMD Value
₹2.0 L
Closing Date
17 Aug 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Office of the Executive Engineer Electrical
SKIMS Soura
SITC of 11 KV Tie Line by way of using XLPE insulated cable from Receiving Station to New ESS Block at SKIMS Soura.
2022_SKIMS_182265_1
eNIT NO.SIMS/HEE/E/ET/30 of 2022-23 Dt. 01-08-2022
Open Tender
Electrical Works
Item Rate
180 days
SKIMS SOura
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
As Described in SBD
₹2.0 L
Yes
24 Aug 2022
2 Aug 2022
18 Aug 2022
2 Aug 2022
17 Aug 2022
3 Aug 2022
Amount
HT Poles & allied items
Supply, mechanical and manual transportation and Erection of following size ST Pole complete with Base Plate and top Cap Confirming to IS 2713 with upto date ammendments complete with red oxide coat and Aluminium Paint Coat. The job includes cost of Stone Pad along with cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required as per REC Stardard 0.4 cum for 7 mtr, 0.5 cum for 9 mtr pole and 0.7 cum for 13 mtr pole .The job includes cost of 3 mtr long 40mm dia GI pipe and G I Strip of Size 25 x3 mm for pole earthing.
a) 410 SP 3 ST poles7mtr Long
b) 410 SP 33 ST poles 9mtr Long
c) 410 SP 56 ST poles 13 mtr Long
Supply fabrication and erection of 75mm x 40mm x 6mm galvanized channel iron cross arm with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mmM.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying and erection of 100 mm X 80 mm 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of11KV, 3 pole ,600 Amp.Horizontal mounting type Isolators Double break with Post type Insulators with Earth Switch (assembled) conforming to IS:9921(Pt.1 to 5)nd other relevant ISS with latest amendmentswith galvanised channel post type, insulator, tinned copper contacts, arching horns ,G.I Pipe operating handle with locking arrangement etc complete as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9KV(rms) and nominal discharge current rating of 5 KA (Station class ) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supplying and erection of galvanised stay set for 11 KV overhead lines complete with 19/ 20 mm dia X 1.8 metres long stayrod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble,stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
HT CABLES & CABLE TRAYS
Supply and laying of 150 mmsq single core 11 KV (E) XLPE cable circular aluminium conductor, conductor screened, XLPE insulated, insulation screened with extruded semi-conducting compound in combination with copper tape. Aluminium round wire armoured and overall PVC sheathed earthed cable conforming to IS:7098/II/85 with latest amendments. a) 4 X 150 mmsq single core = 4x 675 = 2700
Supply and laying of 240 mmsq Three core 11 KV (E) XLPE cable circular aluminium conductor, conductor screened, XLPE insulated, insulation screened with extruded semi-conducting compound in combination with copper tape. Aluminium round wire armoured and overall PVC sheathed earthed cable conforming to IS:7098/II/85 with latest amendments. a) 3C X 240 mmsq =80
Supplying and making indoor cable end termination with heat shrinkable end kit complete with all accessories including lugs suitable for 240 mmsq three core, XLPE aluminium conductor cable of 11 KV grade as required :
Supplying and making outdoor cable end termination with heat shrinkable end kit complete with all accessories including lugs suitable for 240 mmsq three core, XLPE aluminium conductor cable of 11 KV grade as required :
Supplying and making outdoor cable end termination with heat shrinkable end kit complete with all accessories including lugs suitable for 150 mmsq single core, XLPE aluminium conductor cable of 11 KV grade as required :
Supply fabrication and erection of angle iron of size 75 mm X 75 mm X 6 mm for fabrication angle iron bracket/ hangers complete with 50 mm X 6mmM.S. flat iron clamps, bolts and nuts including drilling holes ,foudation bolts, nuts and washers etc and painting with primer and finish paint as required.
EARTHING SYSTEM
Earthing with Copper earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with charcoal or coke and salt) as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
HT PANELS
Supply installation testing & commissioning of HT 12KV, 3Phase 50Hz, totally metal clad withdraw able type Vacuum Circuit Breaker INCOMER CUM OUTGOING (ICOG) panel with Copper bus bar of suitable rating, horizontal isolation type VCB of capacity minimum 630 Amps rated current, as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction with ALUZINC / CRCA sheet powder coated after 7 tank process not less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof.The offered panels shall have following features (i) Mechanical life -30,000 , (ii) Electrical life at Rated Current – 10,000 & (iii) Electrical life at Rated Short Circuit Current – 100 - All the main components like VI/ VCB/ Relays/ Meters shall be of same make. Panel and VCB parameters are as below: (i) Rated Voltage level/ PF withstand voltage/ Impulse level:12KV/ 28kV/ 75 kVp (ii) Continuous current rating: minimum 630A (iii) Short circuit withstand current: minimum 25KA for 3sec. (iv) One no. minimum 630 Amps horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following:- (a)Manually & Motor operated(230V,AC,50Hz) spring charged type, manually and electrically open (electrical – 24 VDC) operation type, incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position. (b)Manual Charging of breaker should be done without opening the front door (c)Cast resin Current transformer 11KV, 400A/1-1A, Core1: class1.0, 15VA for 3 phase , Core2: 5P10, 15VA, Conitinued Below.......
Supplying, Installation, Testing and Commissioning of indoor type floor mounted panel made of AluZinc coated / CRCA sheet steel powder coated after 7 tank process 11 KV integrated VCB panel with 4 nos VCBs (Incoming - 2 nos., Outgoing - 2 nos.) totally enclosed & provision of electrical and mechanical interlocking, horizontal draw out, horizontal isolation type breaker, as per IS 13118, IEC:62271-100& 200, having capacities as mentioned below, single break, trip free mechanism, motorised / manually spring charged and auto / manually closing breaker suitable for use on 11 KV, 3 phase, 50 Hz AC supply with short circuit fault level of 25 KA for 3 sec,IAC AFLR LSC-2B PM classification as per IEC62271 -200 complete with self contained draw out type arc-proof design confirming to relevant IEC standards complete with self-contained, fully interlocked, rack in and rack out mechanism, vacuum bottles,aluminium busbars of 800 Amps capacity, breaker featured with ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switches as required and equipped with following switchgears and accessories i/c necessary foundation & end termination box for terminating HT XLPE 11 KV cable (cable entry from bottom) on primary and secondary side, necessary strip heaters to prevent absorption of moisture during winter and monsoon season, . Vacuum interrupter for VCB shall have minimum 100 nos. operations at full short circuit current rating as specified. Please Note: VCB, VI & Numerical Relay shall be of same make. Continued Below.....
Incoming: 2 nos. (Each comprising of following i/c all required accessories) 1 no 800 Amp, VCB having 11 KV, 25 kA for 3 sec with motorized universal spring charging mechanism, integral spring charging handle for manual spring charge with tripping coil and closing coil for 24 V DC Set of 3 Nos, 11 KV / √3 / 110 / √3 Volts PT Class 0.5 accuracy and 100 VA burden with protection MCBs of suitable rating DigitalMultifunction Meter having V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Maximum Demand (kW & kVA), MD reset with battery charging arrangement for storage of 75 Nos. Events. Accuracy Class : 0.5, Communication Prot: RS485 with suitable Accessories- 1 Set Continued Below.......
Pluggable Relays for contact multiplication, anti-pumping, spring-charging indication etc. where applicable. 1 set of dual core 3 CTs 400/200/1/1 Amp of 15 VA burden and accuracy Class - 0.5 for metering and class 5P10 for protection. Indications : (i) LED type indication for phase (R-Y-B ) (ii) LED type indication for status (ON / OFF / TRIP /TCH / Spring Charge ) (iii) LED type indication for breaker position (Test / Service ) (iv) LED type indication for aux. supply availability ( AC Healthy, DC Healthy ) Note: Incomer feeder shall be Electrically and Mechanically interlocked. Outgoing : 2 nos. (Each comprising of following i/c all required accessories) 1 no 800 Amp, VCB having 11 KV, 25 kA for 3 sec with motorized universal spring charging mechanism, internal spring charging handle for manual spring charge with tripping coil and closing coil for 24 V DC . Continued Below.......
DigitalMultifunction Meter having V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Maximum Demand (kW & kVA), MD reset with battery charging arrangement for storage of 75 Nos. Events. Accuracy Class : 0.5, Communication Prot: RS485 with suitable Accessories- 1 Set Auxialiary Transformer fault relay-3 Pluggable Relays for contact multiplication, anti-pumping, spring-charging indication etc. where applicable. 1 set of dual core 3 CTs 400/200/1/1 Amp of 15 VA burden and accuracy Class - 0.5 for metering and class 5P10 for protection. Indications : (i) LED type indication for phase (R-Y-B ) (ii) LED type indication for status (ON / OFF / TRIP /TCH / Spring Charge ) (iii) LED type indication for breaker position (Test / Service ) (iv) LED type indication for aux. supply availability ( AC Healthy, DC Healthy ) Continued Below.....
Relay :-The relay should have 8 DI & 6 DO and the relay should have multi level password protection 1. Overcurrent protection: The relay should have 3 independent time delayed stages for non-directional three phase over current protection.The first stage and second stage should be programmable to have either a DT characteristic or IDMT characteristic and third stage should be DT only.The relay shall have a current setting range of 10% to 4000% with a time setting of 0.05 seconds to 200 seconds in steps of 0.01 seconds for Definite Time operation for first and second stages and time setting of 0.0 seconds to 200 seconds in steps of 0.01 seconds for Definite Time operation for third stage. 2. Earth fault protection: The relay shall have 3 independent time delayed stages for non-directional earth fault protection. The first stage should be programmable to have either a DT characteristic or IDMT characteristic. Second and third stage should be DT only.The relay shall have a current setting range of 5% to 1200%. The should have a time setting of 0.05 seconds to 200 seconds in steps of 0.01 seconds for Definite Time operation for first and second stages and time setting of 0.0 seconds to 200 seconds in steps of 0.01 seconds for Definite Time operation for third stage. Continued Below.....
3. The Inrush Blocking function measures the ratio of second to fundamental harmonic currents. The relay shall have 2nd harmonic ratio setting range of 10% to 50% with step size of 1%. 4. Thermal Overload: The relay shall have a current-based thermal replica, using r.m.s. load current to model heating and cooling of the protected plant. The element can be set with both alarm and trip stages. The thermal state can be reset by either an opto-input (if assigned to this function using the programmable scheme logic) or the relay menu. The relay shall have setting for base current for thermal replica with setting range of 10% to 300%. The relay shall have option for setting heating time constant and cooling time constant.
Construction of Cable Trench
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: a) 1:3:6 or richer mix (i/c equivalent design mix)
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. a) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for: a) Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc.
Fabrication supply and erection of 6mm chequered plate of required size.
Disconnecting ,shifting of existing LT Panel of Battery charger and control panel . The job includes cost of reconnecting and commisioning at new position in Receiving Station.
TZ Engineering Works
SHA INFRA
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .