| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC 45 58 5 15A AKSHAYA NARASIMHANAGAR VISAKHAPATNAM 530 024 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530024 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹39.3 L+₹1.3 L (3.50%)Rejected-Finance H NO 9 9 1 1 DOCTOR S COLONY SHIVAJIPALEM VISAKHAPATNAM 530 017 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530017 | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹40.3 L+₹2.2 L (5.91%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹40.6 L+₹2.6 L (6.75%)Rejected-Finance | L4 | Rejected-Finance Other than L1 Bidder | |
| 5 | L5₹41.4 L+₹3.4 L (8.83%)Rejected-Finance HARINAGAR BEHIND MAHESHWARY MARKET PO TATISILWAI DIST RANCHI PIN 835103 | RANCHI | JHARKHAND | 835103 | L5 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹38.4 L
EMD Value
₹76,800
Closing Date
20 Mar 2025, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I) (CG), P-16, CGRA Meenampakkam 4th Street NGO Colony, Nanganallur, Chennai 600 061
COMPREHENSIVE MAINTENANCE AND REPAIRS/ REPLACEMENT OF SPARES OF LIFTS INSTALLED AT CGRA PHASE-II MEENAMBAKKAM AREA UNDER GE (I) (CG) CHENNAI
2025_MES_699794_1
8200/E8
Open Tender
Electrical and Maintenance Works
Item Rate
244 days
CHENNAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹76,800
Yes
5 May 2025
1 Mar 2025
22 Mar 2025
1 Mar 2025
20 Mar 2025
7 Mar 2025
1 Mar 2025 - 5 Mar 2025
Amount
NOTE FOR ITEMS NO.1.00 & 2.00: FORTNIGHTLY MAINTENANCE/CHECKS (a) Check the alignment and operation of the Door operating mechanism at all landings (b) Check the action of the brake with lift in Operation (c) Check shoes, pulleys and lubricate (d) Check oil level and oil leakage in the gear
MONTHLY MAINTENANCE/CHECKS (a) Check the position of the operating cum in relation to the landing door and door locks (b) Clean lubricate pivot point and wherever requires (c) Lubricate the brake pin (d) Check suspension of ropes and anchorage and lubricate (e) Check over speed of governor and lubricate the required part (f) Make full ascent and decent to assess the quality of theride at all points
QUARTERLY MAINTENANCE/CHECKS (a) CAR (i) Clean light fixtures (ii) Check retiring cam device chain, dash pots, commutator brush cams, divots, fastenings. (iii) Check emergency switch/battery & Alarm bell (iv) Check safety points, set, screws, switches (b) Check trailing cables for evidence of chaffing orother constructions in the lift well check anchorages. (c) Inspect at every landing, landing doors, tracks,guidesand locks, fasteners and clean and lubricate them.4. Check function box for loose connections and also check mainline switch fuses for heating.
(d) Check car and counter weight guides and shoes. (e) Check whether guide rail surface is smooth and clean. Also check the guide shoes for excessive wear & tear (f) Check and lubricate all bearings & gear box (g) Motor, Generators, Evictor : Clean all commentators and renew or reset brushes if necessary. (h) Ropes : Check all fastening inspect all rope for wear and lubricants (j) Leveling : Check leveling operation and switches
(g) Run the machine in both direction and check sign of excessive play or back lash in gear. Check the overheatingor excessive bearing noise (h) Check oil level and oil leakage in the gear (j) In DC motors and MG sets check commutation for fitting or wear and for signs of undue sparking or brush chatter keeps them clean (k) Check brushes and ensure that spring for adjusting Brush pressure is adjusted to give enough pressure on the brushes. (l) Check the conditions of linings and couplings (m) Check the tightness of the coupling keys
ANNUAL MAINTENANCE/CHECKS (a) MACHINE ROOM (i) Examine all main switches for positive make and break of contacts. Check for loose connections (ii) Clean machine room and ensure proper earthing of motors, controllers, bed plates.
(b) CONTROL BOARD (i) Keeps the controller clean and free from dust (ii) Lubricate all moving parts and check for loose connection if any (iii) Check gap between armature and housing plate (iv) Check and clean all contact (v) Check transformer connections are tight or not (vi) Check resistors, capacitors and rectifiers. (vii) Check fuse ratings etc (c) MACHINE UNIT (i) Check for any abnormality such as vibrations noisetemperature, alignment and check all grease cups and refill if required (ii) Check all bed plate and ensure that all bolts are tight and of the diverting pulley plates and rigid. (iii) Check motor/MG set/DC motor & Techno generatorfor oil levels up to the given marking in case of oil leakage change the oil seal and check the axial play rigidly and belt tension. (iv) GEAR UNIT : Overheating and leaking to be checked for gear box and must be filled with oil (ENKLO-320) (v) BREAK DRUM & COUPLINGS : Check that bolt, nuts, rubberbushes are in appropriate position(if the rubber bushesare found replace them) (vi) Check the running sound, if any unusual running sound develops rectify.
Additional Note for item No 1.00 & 2.00 : (i) The contractor shall enter into a MOU with the OEM for manitenance and repairs of the above work at site. (ii) The spares/electrical items as listed in Sch 'A' Part II will be used whenever required only and measured and paid separately under respective items. (iii) The rate is inclusive of all items as required at site except those items as given in Sch 'A' Part II to keep the lift operational round the clock including cleaning and greasing all moving parts on monthly basis complete all as specified and as directed by Engineer-in-Charge. (iv) If spare parts of original make is not available in market necessary suitable spare equivalent to existing lift part as approved by Engr-in-charge shall be used in the work so that to run the lift with smooth functioning. (v) Cost of renewal of lift license from Lift inspector, Govt. of Tamil Nadu is demed to be included in the qruoted rate against Sl No 1 to 2.
(vi) Quoted rate includes the testing of all the lifts by licensed Lift Inspector of Tamil Nadu twice in contract period for safety if required / asked by GE. Certificate issued by the licensed lift inspector shall be submitted to Engineer-in-charge. (vii) In case of any of the lift/lifts is/are not working for more than 24 hours but less than 10 days, Recovery will be affected at the rate of Rs.2,000/- per lift per day and Rs.3,000/- per lift per day after 10 days. (viii) The above lifts shall be repaired through OEM (Original Equipment manufacturer) or through their nearest authorised/ accredited agency service personel only. The bidder shall submit and uploading MoU from the OEM of lift or their authorised/ accredited agency at time of uploading of tender. (ix) Contractor should submit all valid docucments before the opneing of tehcnicial bid. (x) Testing cerfificte of each lift duly tested by Electrical Lift Inspector shall be provided by the contractor.
SPARE PARTS OF LIFTS
Supply only Main controller transformer primary 415V AC secondary - 24/110/130/230/270v AC. Make:SSPM or equivalent
Supply only Floor oscillator relay optical type working on 12/24 Volt DC.
Supply only Main contactor with coil, 60 Amp, Power contactor with 2 NO + 2NC aux. Contacts and with 230 V AC/DC Coil . Make : C&S, ABB.
Supply only Power contactor 32 Amps with 24/48 V AC / DC coil. Power contactor, 32 Amps with 02 No + 2 NC. Aux contacts with 230 V AC/110VDC complete all as directed. Make : C&S, ABB.
Supply only Digital lift cabin position indicator 1 digit vertical one segment card. Make: IES
Supply only Lift cabin coaxial fan 300 mm 1000 RPM.
Supply only Nylon roller for lift car door and landing door 35X40 mm. Make IES
Supply only BCD to 7 segment card programable type for lift control panel. Make IES
Supply only COP digital position indicator with FL/OL card for lift cabin. Make IES
Supply only ARD 12 relay card. Make : IES
Supply only Lift cabin / Landing illuminated push button working
Supply only Six relay card for lift control panel. Make : IES
Supply only Two relay card for lift control panel. Make : IES
Supply only Three changeover relay 24V DC. Make : PLA
Supply only Two changeover relay 24V DC. Make : PLA
Supply only Trailing cable 10 core x 0.75 Sqmm, 100meter Coil.
Supply only Microprocessor MicroLogix 1200 1762L40BWA. Make : Allen Bradely
Supply only Input module 24 Volts DC l/P or Potential free relay O/P contact to match with MicroLogix 1200. Make : Allen Bradely
Supply only Full length Infrared sensor 04 beams for car door including transmitter, receiver and control unit.
Supply only Charger card of automatic rescue device 230 Volts input / 72 Volts output . Make Jeltron /IES.
Supply only Microprocessor card of automatic rescue device Make Jeltron /IES.
Supply only Converter card of automatic rescue device to convert 72 Volts DC input to 24 Volts DC output Make Jeltron /IES.
Supply only MOSFET card of automatic rescue device to covert 72VDC to 230 Volts AC 3 Amps. Make :Jeltron / IES
Supply only Rotary encoder for speed feedback of main drive
Supply only Door motor and suitable VVVF drive for car door operation. Make : Monarch
Supply and fix in repair of unserviceable VVVF drive up to 15 KW for lift motor up to 11KW including feeding all parameters and interfacing with controller micro processor and drive including setting of basic parameters to obtain the desired and designed value of various motions of the lift complete Suitable for passenger Lift complete all as specified and directed by Engr-in-Charge. Make : Toshiba/ Square-D/ AB /GEFRAN
Supply only Car Door Operator for 800 mm Centre Opening Door along with bottom Aluminum Cill, Stainless Steel Door Panel with Vision Panel of size 200 X 800 mm with 8 mm Toughened Glass complete made out of AISI 304 Grade Stainless Steel Sheet of 1.5mm thick, Car Door Motor with Built-in Rotary Encoder, VVVF Drive for Car Door operation, Full Length / Infra Red Sensor, 64 Beams for Car Door including Transmitter, Receiver and Control Unit working on 230 Volts, AC. Make : IES
Supply only Landing Door Mechanism of 800 mm Centre Opening Door along with Bottom Aluminum sill Make : IES
Supply only Maintenance free sealed battery 12V 7AH. Make : Exide/ Amaron/Amco
Supply only Lift landing door rope for 800mm center opening door mechanism. Make : IES.
Supply only car door operator belt for 800mm center opening door mechanism. Make : IES.
SERVO-TECH ENTERPRISES (BID ID -3260270)
SANTOSH CONSTRUCTIONS (BID ID -3262023)
SATYAM ENGINEERS (BID ID -3260673)
UNIVERSAL ENTERPRISES (BID ID -3261934)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .