Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32,912.56Accepted-AOC AT PO DAKRA KHALARI DIST RANCHI JHARKHAND PIN 829210 | RANCHI | JHARKHAND | 829210 | L1 | Accepted-AOC TechnoCommercially acceptable | |
| 2 | Rejected-Technical AT DAKRA KHALARI RANCHI JHARKHAND PIN CODE 829210 | RANCHI | RANCHI | JHARKHAND | 829210 | - | Rejected-Technical Not uploaded all documents as per clauses as well as it is not lowest bidder | |
| 3 | Rejected-Technical 00 C O LAKHAN LAL AGRAWAL RATU ROAD NEAR KABLISTHAN RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | - | Rejected-Technical Not uploaded all documents as well as not the lowest bidder |
Tender Value
₹30,167
Closing Date
24 Oct 2022, 11:00 amClosed
Project Engineer(EnM) Rohini OCP, NK Area, CCL
OFFICE OF THE PROJECT OFFICER, PROJECT ENGINEER (EnM) DEPT.ROHINI OCP, NK AREA,DISTT-RANCHI-829210
Repair and maintenance of internal wiring along with service connection of Qtr. No.- B122 at Dakra of Mubarak Khan(Sr. Cashier) in respect of Rohini Project
2022_CCL_259338_1
PE(EnM)/RH/eNIT/22-23/70
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Rohini Project, NK Area, CCL
Please refer Tender documents.
4 documents required · 4 mandatory
17 Mar 2023
14 Oct 2022
25 Oct 2022
15 Oct 2022
24 Oct 2022
15 Oct 2022
15 Oct 2022 - 20 Oct 2022
Amount
Wiring of light point / call bell with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size MS box and earthing point with 1.5 sq. mm FRLS PVC insulated copper conductor single core etc as required.
Supply and fixing metal box of 150mmX 75mm X 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3pin 5/6A socket outlet and 5/6A piano type switch, connection, paintingetc, as required(for light plugs)
Supply and fixing metal box of 180mmX 100mm X 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6pin 5/6A socket outlet and 5/6A piano type switch, connection, paintingetc, as required(for light plugs)
Supply and drawing of following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surfce/ recessed steel/PVC conduit as required 2 X 6 sq. mm
Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/wooden block including connection etc., as required.
Supplying and fixing brass batten/angle holder including connectionetc. As required
Supply and fixing 5A to 32A rating,240/415V , “C” curve, MCB suitable for Inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc. as required.
Providing and fixing 32A TP&N disconnector fuse switch unit inside the existing panel board with ISI mark HRC fuses including drilling holes in cubicle panel, making connections, etc as required.
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate
Fuse Kit Kat 32 Amp.
Earthing with GI pipe 4.5m long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc(but without charcoal and salt)
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required.
Total impact of GST for the purpose of CTC
M/S A. K. ENTERPRISES
M/S PRAVEEN KUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_268184.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .