| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹1.1 LQualified Make: SEEMEX
Model: SEEMEX B 6 GUPTA COMPLEX B 6 OLD ROHTAK ROAD GUPTA COMPLEX DELHI 110035 INDERLOK NORTH WEST DELHI DELHI 110035 | NORTH WEST DELHI | DELHI | 110035 | Make: SEEMEX
Model: SEEMEX | L2 | Qualified | |
| 2 | L3₹1.1 LQualified Make: intime
Model: STD4-50 153 K L SECTOR 53 EPIP KUNDLI SONEPAT SONIPAT HARYANA 131028 | SONIPAT | HARYANA | 131028 | Make: intime
Model: STD4-50 | L3 | Qualified | |
| 3 | L4₹1.1 LQualified Make: SAFEPRO
Model: SFSPL2 16 1ST FLOOR CHUNAWALA BUILDING NEAR AL SADIQ HOSPITAL MOHAMMAD ALI ROAD MANDVI MUMBAI MAHARASHTRA 400003 | MUMBAI | MAHARASHTRA | 400003 | Make: SAFEPRO
Model: SFSPL2 | L4 | Qualified | |
| 4 | L4₹1.1 LQualified Make: FIREMATICS
Model: FIREMATICS (MAP BASED 4 KGS) 00 OM INDUSTRIES 7 7 KM STONE V PO TITOLI JIND ROAD TITOLI MOD ROHTAK HARYANA 124001 | ROHTAK | HARYANA | 124001 | Make: FIREMATICS
Model: FIREMATICS (MAP BASED 4 KGS) | L4 | Qualified | |
| 5 | L5₹1.1 LQualified Make: LIFESECURE
Model: Lifesecure, Model-852 E 173 SECTOR 4 DSIIDC INDUSTRIAL AREA BAWANA DELHI 110039 NORTH WEST DELHI DELHI 110039 | NORTH DELHI | DELHI | 110039 | Make: LIFESECURE
Model: Lifesecure, Model-852 | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
22 May 2018, 1:00 pmClosed
Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 150 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure
Gas Cartridge Type Extinguishing Media Powder Based Water Based
Foam Based
Powder Based
Carbon Dioxide Based
Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based
N2 Based (Stored Pressure)
CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media ABC - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire Extinguisher Capacity (Kg) 4 4 1/4 Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2
3
4.5
NA Water Based Fire Extinguisher Capacity NA 2
NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2
NA Weight of Filled Portable Fire Extinghuisher (Kg) 6.5 Rechargebale true - Color Coding Blue - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -20° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar
Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 13 seconds Fire Rating for Class -A Fire Extinguisher 2A - 2/4 Fire Rating for Class -B Fire Extinguisher 21B - Certification BIS Marking Yes - CM/L No.* with Validity Period 8700061214 Validity upto 10.04.2018 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 130932 - Test Report Date 23.01.2017 - Name of the Lab Fire Test & Research Laboratory - Address of the Lab 9th Milestone
SH-11
Sonepat-Gohana Road
Rattangarh
Sonepat – 131001 (Haryana) - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anurag Krishna Agrawal 231222
OFFICE OF GENERAL MANAGER
DUDHICHUA AREA
PO - KHADIA DISTT - SONEBHADRA UTTAR PRADESH 231222 150 15 EMD Required No ePBG Required No
83917
GEM/2018/B/11972
Portable Fire Extinguishers IS 15683
15 days
Uttar Pradesh; Sonbhadra
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 150 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Powder Based Water Based | - | - | - |
| Foam Based | - | - | - |
| Powder Based | - | - | - |
| Carbon Dioxide Based | - | - | - |
| Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based | - | - | - |
| N2 Based (Stored Pressure) | - | - | - |
| CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media ABC - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire Extinguisher Capacity (Kg) 4 4 1/4 Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| 3 | - | - | - |
| 4.5 | - | - | - |
| NA Water Based Fire Extinguisher Capacity NA 2 | - | - | - |
| NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (Kg) 6.5 Rechargebale true - Color Coding Blue - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -20° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar | - | - | - |
| Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 13 seconds Fire Rating for Class -A Fire Extinguisher 2A - 2/4 Fire Rating for Class -B Fire Extinguisher 21B - Certification BIS Marking Yes - CM/L No.* with Validity Period 8700061214 Validity upto 10.04.2018 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 130932 - Test Report Date 23.01.2017 - Name of the Lab Fire Test & Research Laboratory - Address of the Lab 9th Milestone | - | - | - |
| SH-11 | - | - | - |
| Sonepat-Gohana Road | - | - | - |
| Rattangarh | - | - | - |
| Sonepat – 131001 (Haryana) - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anurag Krishna Agrawal 231222 | - | - | - |
| OFFICE OF GENERAL MANAGER | - | - | - |
| DUDHICHUA AREA | - | - | - |
| PO - KHADIA DISTT - SONEBHADRA UTTAR PRADESH 231222 150 15 EMD Required No ePBG Required No | - | - | - |
Exempted
22 May 2018
12 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_83917.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .