Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
1 May 2024, 3:00 pmClosed
SE EDC MAHOBA
BAJARIYA MAHOBA
MAJOR OVERHAULING AND REPAIRING OF DIFFIRENT MAKE 33 KV VCB TYPE CIRCUIT BREAKER 33/11 KV SUBSTATION EDC MAHOBA (BUS_PLAN 2024-25)
2024_DVVNL_920678_2
92/SE/EDCM/2023-24
Open Tender
Electrical Works
Item Rate
180 days
MAHOBA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
www.dvvnl.org
₹10,000
25 May 2024
26 Apr 2024
1 May 2024
26 Apr 2024
1 May 2024
26 Apr 2024
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Cartage of Erection Major overhauling and repairing of Diffirent Make 33 KV VCB type circuit breaker 33/11 KV Substation EDC Mahoba :- Each. VCB and CRP Pannel Work as Follows. and also including the cost of labour, T&P carrier etc. required for proper completion of work. | |||||
| 1.01 | 1- Cleaning of porcelain of drive insulator and porcelain of vacuum interrupter from inside and outside of each pole.
2-Checking & adjustement of snatch gap, travel of drive insulator rod & tie rod of each pole.
3-Opening, repairing of mechanism by welding, drilling, machning and filling of material as per requirement and proper fitting of it in breaker cubicle.
4-Oiling & greasing of crank gears by opening of lock circlip etc.
5-Replacement of worn out parts such as bush, rings, lock pins and latch etc.
6-Checking & adjustment of oil daspot of breaker for its damping action. | 10 | JOB | - | - |
| 2After major overhauling and repairing of above VCB, following tests are to be carried out :- | |||||
| 2.1 | 1- Repairing/Wiring of CRP Pannel and Make Operational.
2- Opening & closing time of breaker of each pole.
3- Carrying out Contact Resistance Measurement (CRM test) of each pole.
4- Checking of megger values of breaker poles.
5-Checking triping of breaker at 70% DC voltage.
6- Checking the CLOSE/OPEN operation of breaker from REMOTE & LOCAL.
7-Prepare and submit the site ovehauling report of each breaker. | 10 | JOB | - | - |
| 3As Required Supply and Installation of Material for 33 KV Brecker/Pannel | |||||
| 3.1 | Relay Ashida Make | 8 | No | - | - |
| 3.2 | Triping Coil | 5 | No | - | - |
| 3.3 | Ampere Meter | 5 | No | - | - |
| 3.4 | Alaxuary Switch | 5 | No | - | - |
| 3.5 | 33 KV CT 400/200/A | 3 | No | - | - |
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tendernotice_1.pdf
Tender Document • 1.56 MB
92R.pdf
Tender Document • 1.71 MB
BOQ_1594869.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .