Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.2 LAccepted-AOC B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | ₹46.2 L Quoted ₹47.7 L | L1 | Accepted-AOC Contract was awarded to lowest bidder |
| 2 | L2₹48.4 LRejected-Finance | ₹48.4 L | L2 | Rejected-Finance Not become lowest bidder |
| 3 | L3₹50.0 LRejected-Finance | ₹50.0 L | L3 | Rejected-Finance Not become lowest bidder |
| 4 | L4₹50.4 LRejected-Finance | ₹50.4 L | L4 | Rejected-Finance Not become lowest bidder |
| 5 | L5₹51.2 LRejected-Finance 0 BISAI TIKAITGANJ FATEHPUR BARABANKI UTTAR PRADESH 225302 | BARABANKI | UTTAR PRADESH | 225302 | ₹51.2 L | L5 | Rejected-Finance Not become lowest bidder |
| Sl No | Description | Qty | Unit | ROHIT ENTERPRISES L8 | M/s Sohanil Construction L7 | SAMEER ELECTRICAL SUPPLIER L1 | PRADEEP SISODIYA L4 | ADARSH ENTERPRISES L5 | F B ELECTRICALS L3 | M/S BIGBEST CONSTRUCTION L6 | PRAGATI ELECTRICALS AND ELECTRONICS L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Attending daily complaints of Jhansi Mil area incl Calib Vihar and AAU by deputing adequate number of Skilled teams of qualified Electrician and helper any time of the day ( Minimum 01 Skilled Electrician & 02 Helper ) for repair / tightening of end terminals of street light fitting, Flood light, LED strip on poles , High Mast light , Post top lanten of any size/capacity at any height and repair the street lights, Flood lights and Post Top lanten having minor faults i.e loose connections, carbon deposition , Shifting and refixing the same etc and make the light functional. After rectifying the defects of the electrical system replace the U/S items such as street light , flood lights, LED strips, MCBs TPN ,connection plate , thimbles and timmer small pieces of electrical cables PVC insulated copper multistranded conductor of sizes 2.5 Sqmm to 6 Sqmm twin core and length not increasing 1.5 mtrs complete all as specified and directed by Engr-in-Charge. (Complaint slip shall be part of the bill) and In Addition one 16 mtrs hight hydraulic vehicle with driver & operator of the same team will opearte and manage day to day street light Complaints and update the status of complaints on daily basis and confirmed throgh concerned JE E/M daily as per directed by Engr-in Charge.
Note:-
(i)Complaint shall be done within 24 hrs after intimation by JE E&M Engineer-in-Charge failling which penalty of Rs 250 per day per complaint will be levied on contractor.
(ii) One supervisor will report to JE E/M , Engineer -in-Charge on daily basis with complaint register.
(iii) Contractor shall be fully responsible for Complaint slip/ Job card prepared and submitted on daily basis ( Format as per provided by the Engineer in Charge.
(iv) This item pertains to attending complaints of street light/flood light/LED strips on poles/High mast, MCB, & timer panel including other minor items such as insulating tape, screws etc as required to attend the complaint to the entire satisfaction of user/Engr-in-Charge.
(v) Items shall be measured and paid seperately under respective item of Sch 'A' | 404 | Each Job | 230 ₹92,920 | 165 ₹66,660 | 100 ₹40,400 | 200 ₹80,800 | 150 ₹60,600 | 180 ₹72,720 | 130 ₹52,520 | 150 ₹60,600 |
| 2.00 | Material and labour for overhauling of existing 16 meters height high mast lighting system by degreasing and cleaning of double drum winch, gear box, wire rope, clamp, bobbin arrangement, power tool motor, mechanical torque limiter, lowering the mast head assembly, degreasing and cleaning the pulley, docking arm etc and applying new grease / lubricating oil for all mechanical moving / rotating parts, checking all the electrical parts such as timer panel, all cable connections in control panel, motor, junction box, flood light fittings & aviation obstruction light fitting etc, rectifying the defects, renewing the defective components etc including testing for proper functioning complete all as specified and directed by Engineer-in-Charge. Note: Replacement of flood light fittings, aviation obstruction light, control cable, steel wire rope , timer panel components & rewinding of motor if required at site shall be measured and paid separately. However, the cost of minor spare parts & lubrication is deemed to be included in the quoted rate. | 7 | Each Job | 6,750 ₹47,250 | 5,555 ₹38,885 | 4,000 ₹28,000 | 4,600 ₹32,200 | 5,000 ₹35,000 | 4,200 ₹29,400 | 4,500 ₹31,500 | 4,500 ₹31,500 |
| 3.00 | Supply and fix in replacement of 250 Watt LED flood light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP65 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including surface mounting using adjustable MS cradle of thickness 5 mm provided with the fixture including taking down existing unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge.
Note :
LM 79 test report, LM 80 report with minimum 9000 hrs testing to support 50K life TTC and dirver NABL accreditated report shall be submitted before execution of work to the Engineer - in - charge. | 15 | Each | 5,750 ₹86,250 | 5,255 ₹78,825 | 4,500 ₹67,500 | 5,700 ₹85,500 | 6,500 ₹97,500 | 5,900 ₹88,500 | 6,000 ₹90,000 | 6,000 ₹90,000 |
| 4.00 | All as per Serial Item No. 3.00 here-in-before but of 200 Watt LED flood light fitting. | 20 | Each | 5,050 ₹1.0 L | 5,655 ₹1.1 L | 4,200 ₹84,000 | 5,300 ₹1.1 L | 5,500 ₹1.1 L | 5,100 ₹1.0 L | 5,000 ₹1 L | 5,000 ₹1 L |
| 5.00 | All as per Serial Item No. 3.00 here-in-before but of 150 Watt LED flood light fitting. | 15 | Each | 5,000 ₹75,000 | 4,955 ₹74,325 | 4,000 ₹60,000 | 4,700 ₹70,500 | 4,800 ₹72,000 | 4,400 ₹66,000 | 4,300 ₹64,500 | 4,500 ₹67,500 |
| 6.00 | All as per Serial Item No. 3.00 here-in-before but of 100 Watt LED flood light fitting. | 18 | Each | 3,400 ₹61,200 | 3,955 ₹71,190 | 2,800 ₹50,400 | 3,700 ₹66,600 | 3,800 ₹68,400 | 3,900 ₹70,200 | 3,500 ₹63,000 | 4,000 ₹72,000 |
| 7.00 | All as per Serial Item No. 3.00 here-in-before but of 80 Watt LED flood light fitting. | 15 | Each | 3,000 ₹45,000 | 3,455 ₹51,825 | 2,200 ₹33,000 | 3,200 ₹48,000 | 3,350 ₹50,250 | 2,800 ₹42,000 | 3,300 ₹49,500 | 3,000 ₹45,000 |
| 8.00 | All as per Serial Item No. 3.00 here-in-before but of 50 Watt LED flood light fitting amber/ green/cool white/worm white. | 20 | Each | 2,100 ₹42,000 | 2,455 ₹49,100 | 2,000 ₹40,000 | 2,200 ₹44,000 | 2,300 ₹46,000 | 2,550 ₹51,000 | 2,100 ₹42,000 | 2,500 ₹50,000 |
| 9.00 | Supply and fixing energy saving LED INVERTER TYPE STREET LIGHT 45 WATT AND BATTERY BACK UP OF MINIMUM 8 HOURS environmental friendly, long life , exclusive innovative die-cast aluminium IP 66 security light with high power LEDs as light source , Suitable for 40 mm GI pipe , 5700K LED connecting up with twin core twisted flexible copper conductor cable all as directed.
Note :-
LM 79 test report, LM 80 report with minimum 9000 hrs testing to support 50K life TTC and dirver NABL accreditated report shall be submitted before execution of work to the Engineer-in-Charge. | 20 | Each | 6,230 ₹1.2 L | 5,555 ₹1.1 L | 5,000 ₹1 L | 4,800 ₹96,000 | 5,000 ₹1 L | 4,850 ₹97,000 | 4,500 ₹90,000 | 5,000 ₹1 L |
| 10.00 | All as per Serial Item No. 9.00 here-in-before but of 60 Watt LED flood light fitting amber/ green/cool white/worm white. | 30 | Each | 7,200 ₹2.2 L | 5,395 ₹1.6 L | 6,000 ₹1.8 L | 5,200 ₹1.6 L | 5,300 ₹1.6 L | 5,000 ₹1.5 L | 4,800 ₹1.4 L | 5,000 ₹1.5 L |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Apr 2026, 6:00 pmClosed
Maj Rajesh Rathore
Garrison Engineer Jhansi
CERTAIN REPAIR AND MAINTENANCE WORKS TO HIGH MAST LIGHTS, SECURITY LIGHTS, SOLAR LIGHTS, etc AT JHANSI CANTT UNDER AGE E/M AT GE JHANSI
2026_MES_758229_1
GE/JHA/TOK/115 OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE Jhansi
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Jhansi
₹1 L
Yes
23 Jun 2026
28 Mar 2026
20 Apr 2026
28 Mar 2026
18 Apr 2026
11 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Attending daily complaints of Jhansi Mil area incl Calib Vihar and AAU by deputing adequate number of Skilled teams of qualified Electrician and helper any time of the day ( Minimum 01 Skilled Electrician & 02 Helper ) for repair / tightening of end terminals of street light fitting, Flood light, LED strip on poles , High Mast light , Post top lanten of any size/capacity at any height and repair the street lights, Flood lights and Post Top lanten having minor faults i.e loose connections, carbon deposition , Shifting and refixing the same etc and make the light functional. After rectifying the defects of the electrical system replace the U/S items such as street light , flood lights, LED strips, MCBs TPN ,connection plate , thimbles and timmer small pieces of electrical cables PVC insulated copper multistranded conductor of sizes 2.5 Sqmm to 6 Sqmm twin core and length not increasing 1.5 mtrs complete all as specified and directed by Engr-in-Charge. (Complaint slip shall be part of the bill) and In Addition one 16 mtrs hight hydraulic vehicle with driver & operator of the same team will opearte and manage day to day street light Complaints and update the status of complaints on daily basis and confirmed throgh concerned JE E/M daily as per directed by Engr-in Charge.
Note:-
(i)Complaint shall be done within 24 hrs after intimation by JE E&M Engineer-in-Charge failling which penalty of Rs 250 per day per complaint will be levied on contractor.
(ii) One supervisor will report to JE E/M , Engineer -in-Charge on daily basis with complaint register.
(iii) Contractor shall be fully responsible for Complaint slip/ Job card prepared and submitted on daily basis ( Format as per provided by the Engineer in Charge.
(iv) This item pertains to attending complaints of street light/flood light/LED strips on poles/High mast, MCB, & timer panel including other minor items such as insulating tape, screws etc as required to attend the complaint to the entire satisfaction of user/Engr-in-Charge.
(v) Items shall be measured and paid seperately under respective item of Sch 'A' | - | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
BOQ_849285.xls
BOQ • 0.55 MB
TenderDocuments115.pdf
Tender Documents • 1.29 MB
Download all tender documents and submit your bid