Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹11.8 L+₹2.1 L (21.4%)Rejected-Finance | L2 | Rejected-Finance Not Being lowest | |
| 3 | L3₹12.4 L+₹2.7 L (27.6%)Rejected-Finance | L3 | Rejected-Finance Not Being lowest | |
| 4 | L4₹15.5 L+₹5.8 L (59.5%)Rejected-Finance | L4 | Rejected-Finance Not Being lowest |
Tender Value
₹13.2 L
EMD Value
₹26,320
Closing Date
16 Oct 2020, 6:00 pmClosed
GE 970 EWS
GE 970 EWS C/o 56 APO
SPL REPAIR OF LT PANELS AT CERTAIN EM INSTALLATIONS AT OLD AIR FEILD UNDER GE 970 EWS
2020_MES_378485_1
GE 970 EWS- 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Old air field
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹26,320
Yes
17 Nov 2020
18 Sept 2020
19 Oct 2020
18 Sept 2020
16 Oct 2020
2 Oct 2020
Amount
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed.
Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc . 1.5M above the starting point complete all as specified and directed.
Supply and laying dry river/M-sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness only measured and paid
M & L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.
Supply, laying and testing XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor confirming to IS : 7098 (Part-I) of cross-sectionsl area 95 sq mm 3½ core including Taking out the existing underground cable complete all as specified and directed.
All as per serial item No 6 but size 120 sq mm 3½ core
All as per serial item No 6 but size 25 sq mm 4 core
All as per serial item No 6 but size 35 sq mm 3½ core
All as per serial item No 6 but size 50 sq mm 3½ core
All as per serial item No 6 but size 70 sq mm 3½ core
S & F in repairs MCCB 4 Pole, current rating 400 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, of (Make : L & T Cat No CM93003OOOOX1 or equivalent in Legrand / Schneider electric) incl necessary spreaders / cable lugs / nut, bolt and washers if required complete all as direcetd
All as per item No 18 here in before but 4 pole 500 A, having breaking capacity 36 kA (Make : L & T Cat No CM93007OOOOX1 or equivalent in Legrand / Schneider electric)
All as per item No 18 here in before but 4 pole 315 A, having breaking capacity 36 kA (Make : L & T Cat No CM93003OOOOX1 or equivalent in Legrand / Schneider electric)
All as per item No 18 here in before but 4 pole 250 A, having breaking capacity 36 kA (Make : L & T Cat No CM92151OOOOX1 or equivalent in Legrand / Schneider electric)
All as per item No 18 here in before but 4 pole 63 to 160 A, having breaking capacity 36 kA, (Make : L & T Cat No CM92152OOOOX1 or equivalent in Legrand / Schneider electric)
Material and labour for earthing complet with galvanised steel earth plate electrode 60cmx 60cmx 6.00 mm thick buried directly in ground (Earth pit not less than 2.25 metre below normal ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected and including GI strip 32mm x 6mm by means of GI bolts, nuts, check nuts and washers, earth plate surrounded by packed alternate layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh and 50mm bore GI pipe light grade for protection of GI strip 32mmx6mm from top of earth plate upto test point (upto 7.5metre in length) connected with suitable size of GI nuts, bolts and washers all as shown in Electrical plate No. 3 of SSR Part-I, testing on completion including excavation/earth work in any type of soil/rock, PCC chamber (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways with suitable handle for lifting arrangement & including formwork and MS frame using MS angle iron 40x40x6mm complete all as specified and directed. Note :- Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit.
M/S Noor Mohammad Shalla
yattoo contractors
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .