| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.4 LAccepted-AOC | 1 | Accepted-AOC LI BIDDER | |
| 2 | 2₹29.8 L+₹5.9 L (24.5%)Rejected-AOC B 42 B 42 SECOND FLOOR SECOND FLOOR VILLAGE TOWN SECTOR 65 CITY NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 INDIA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | 2 | Rejected-AOC L2 BIDDER | |
| 3 | 3₹31.9 L+₹8.0 L (33.4%)Rejected-AOC G 132 FIRST FLOOR G BLOCK SECTOR 63 SECTOR 63 GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | 3 | Rejected-AOC L3 BIDDER |
Tender Value
₹28.2 L
EMD Value
₹56,000
Closing Date
14 Mar 2020, 1:00 pmClosed
Superintending Engineer
Superintending Engineer OMC 5 BTPS ANPARA
Routine, Breakdown Maintenance and Testing of 400/132/33/11KV Switchyard equipments and associated auxiliaries of Anpara A and B TPS Switchyard.
2020_RVUNL_425912_1
T-01/ESMD/BTPS/2020-21
Open Tender
Electrical Works
Fixed-rate
365 days
400KV BTPS switchyard ATP Anpara
as per tender documents
3 documents required · 3 mandatory
₹1,180
Dy CAO CFA and BO BTPS Anpara
₹56,000
29 May 2020
21 Jan 2020
16 Mar 2020
21 Jan 2020
14 Mar 2020
21 Jan 2020
Amount
PART- A: ROUTINE MAINTENANCE WORKS
Round the clock operation of air compressors of ‘A’TPS daily (including SUNDAYS & HOLIDAYS).
Routine Maintenance of 400 KV‘A’ TPS, Switchyard in Anpara.
Routine Maintenance of 400 KV‘B’ TPS, Switchyard in Anpara.
Routine Maintenance of 132 /33/11KV‘A’ TPS, Switchyard in Anpara.
Routine Maintenance of 100MVA ICTs, 10MVA CS-1&2, 400/33KV reactor 220/48V battery system & MCC room etc.
PART- B: BREAKDOWN MAINTENANCE WORKS Providing assistance in the following works
Dismantling, erection, commissioning & testing of 400/132KV Lightning arrestor & CVT.
Dismantling, erection, commissioning & testing of 400KV CT.
Dismantling, erection, commissioning & testing of 132KV CT.
Preventive maintenance of 400KV Sequential /Pantograph isolator including bearing O/H
Preventive maintenance of 132KV Sequential isolator including bearing O/H
Providing shunts/ restrengthening /replacement of 400/132KV damaged jumper.
Centrifuging of oil of 100MVA ICTs/ Reactor / 10MVA Transformer per day.
Replacement of pantograph isolator of one pole
Replacement of support insulator of pipe bus of 400/132KV along with associated work
Rewinding of induction motors of 3 phase, 415-430 volt and 220V DC motors of following rating.
Up to 1.0 KW
Above1.0 KW & up to 2.5 KW
Above 2.5 KW & up to 5.0 KW
Above 5.0 KW & up to 10.0 KW
Above 12.0 KW & up to15.0 KW
Overhauling of 3 phase, 415-430 volt, induction motors of following ratings:
Up to 5.0 KW
Above 10.0 KW & up to 15.0 KW
Replacement of Male & or Female contacts of one pole of 11KV MOCB breaker.
Replacement one pole of 11 KV VCB breaker
Replacement of wave trap of one phase
Replacement of trapeze assembly
Replacement of Pilot Valve of 400 KV BHEL/Siemens SF6 Breaker
Erection and Dismantling of Scaffolding in 132/400 KV switchyard per pole
Replacement of one Buchholz relay of ICT/Reactors/10 MVATransformer.
Shifting of one 10 –14 KL capacity oil tank
Replacement of PRV of 100MVA,400/132/33KV ICT
Attending hot spot from 400KV/132KV Switchyard Equipments.
Attending air leakages from cooler tubes of IR make type 15T-2 air compressors by replacing the faulty tube with new/repaired tube:
Attending problem of safety valve floating of various stages of 15T-2 compressors:
Attending mal-functioning of 60Kg/cm2 air pressure reducers and solenoid valves by replacing O-rings, gaskets & seals
Attending problem of air leakage/passing from 60Kg/CM2 NRV by replacing faulty valves seals, spring etc
Checking and attending air leakage from 400/132 KV S/Y compressed air line stop valves, NRV etc
Brazing, cutting and jointing the finned tube cooler nest for attending the air leakage from 60Kg/cm2 finned tubes of stage-I,II,III of 15T-2 compressors are to be repaired
Brazing, cutting/jointing works on 30Kg/cm2 compressed air pipe line of 400/132 KV S/Y:
Replacement of desiccant material & overhauling of heat less air drier.
Replacement of crank shaft of 15T-2 IR make compressors
O.H. of Compressors
Disconnecting and connecting of terminal connectors at transformer bushing of ICT/GT per phase
Shorting of all the three phases of Generator bay
PART- C: TESTING WORKS
400 KV SF6 Circuit breaker timing test.
132 KV ABCB/SF6 Circuit breaker timing test.
132 KV ABCB/SF6 Circuit breaker static contact resistance measurements.
400 KV SF6 Circuit breaker static contact resistance measurements.
400 KV Centre break isolator contact resistance measurement.
132 KV Centre break isolator contact resistance measurement.
Testing of 400 KV CT & its connected circuit.
Testing of 132 KV CT & its connected circuit.
Testing of protection and tripping relays of 132/6.9 KV & 132/11KV Transformers
Testing of 11/33 KV MOCB/Vacuum Circuit breaker(R,Y&B phase)
Testing of 11/33KV CT and it’s connected circuit.
Circuit Breaker Timing Test Kit
Contact Resistance Measurement test kit
Primary Injection Test Kit
Testing of Distance Protection numerical relays (REL670, 7SA522, P543 and P542)
Testing of Transformer Differential, REF, etc. Protection numerical Relay (P645).
Testing of Over Current, Earth Fault, etc. Protection numerical Relay (P142).
Testing of 11 KV Over Current, Earth Fault, etc. Protection numerical Relay (VAMP).
Relay Test Kit
OASIS TECHNO ENGINEERS Pvt. Ltd.
ELITE POWERTECH Private Limited
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .