| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹1.1 Cr+₹24.4 L (28.5%)Admitted-Finance A 45 NTPC VIDYUT NAGAR DADRI GB NAGAR 201008 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201008 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical PQC not Fulfill |
| Sl No | Description | Qty | Unit | M/s Power Tech Engineering Co. L2 | M/s B M ENGINEERING L1 |
|---|---|---|---|---|---|
| 1.00PART-A:- Overhauling of Boiler Pressure Parts of Unit # 9, 2x250MW | |||||
| 1.01 | Supply & erection of cup-lock scaffolding in 1st Pass and conventional scaffolding in 2nd Pass of 250MW Boiler (60 Days). (As per scope of work) | 1 | Job | 29,55,000 ₹29,55,000 | 23,00,000 ₹23,00,000 Lowest |
| 1.02 | Water washing of Boiler (external and internal) and Jet cleaning of Boiler Pressure Part Tubes by HP jet pump & De-slugging of tubes of Boiler. (As per scope of work) | 1 | Job | 5,04,250 ₹5,04,250 Lowest | 6,00,000 ₹6,00,000 |
| 1.03 | DP test for dissimilar joints, header stubs etc. of boiler tubes. (As per scope of work) | 1,500 | Joints | 175 ₹2,62,500 | 126.72 ₹1,90,080 Lowest |
| 1.04 | Rectification by replacement of defective tube and bend of boiler pressure part tubes. (Including survey, cutting & lifting/lowering of 30 Nos. module/hangers each of LTSH / Economizer & re-assembly of the same). (As per scope of work) | 2,700 | Joints | 1,450 ₹39,15,000 | 1,000 ₹27,00,000 Lowest |
| 1.05 | Fin welding of water wall & SCW tubes (single side welding of fin) | 400 | RM | 222 ₹88,800 | 174.72 ₹69,888 Lowest |
| 1.06 | Repairing of furnace ceiling of Penthouse & doghouse. Refractory work in all the areas of boiler. ATT of boiler.(As per scope of work) | 1 | Job | 4,05,000 ₹4,05,000 | 3,48,669.12 ₹3,48,669.12 Lowest |
| 1.07 | Providing SS heat shield in all the erosion prone area of 1st pass & 2nd pass of boiler. | 1,500 | Nos. | 280 ₹4,20,000 | 187.2 ₹2,80,800 Lowest |
| 1.08 | Fabrication of tube bends | 25 | Nos. | 680 ₹17,000 | 610.56 ₹15,264 Lowest |
| 1.09 | Alignment of all S/H, R/H coils and spacers tubes of re -heater and super –heater etc. | 100 | Nos. | 2,990 ₹2,99,000 | 2,673.6 ₹2,67,360 Lowest |
Tender Value
₹86.6 L
EMD Value
₹1.2 L
Closing Date
24 Oct 2025, 1:00 pmClosed
SE OMC II DTPS Kasimpur Aligarh
Office of the SE OMC II DTPS Kasimpur Aligarh Mobile No 9415900792
Overhauling of Boiler Pressure Parts of Unit 9 BMD I DTPS Kasimpur
2025_RVUNL_1073516_1
STET-16/OMC-II/BMD-I/D/25-26
Open Tender
Repair and Maintenance Works
Lump-sum
60 days
BMD I DTPS Kasimpur Aligarh area
As per PQC of Tender Documents
4 documents required · 4 mandatory
₹5,900
SAO EPAD HTPS KASIMPUR ALIGARH
₹1.2 L
11 Nov 2025
12 Sept 2025
25 Oct 2025
12 Sept 2025
24 Oct 2025
12 Sept 2025
12 Sept 2025 - 23 Oct 2025
Amount
PART-A:- Overhauling of Boiler Pressure Parts of Unit # 9, 2x250MW
Supply & erection of cup-lock scaffolding in 1st Pass and conventional scaffolding in 2nd Pass of 250MW Boiler (60 Days). (As per scope of work)
Water washing of Boiler (external and internal) and Jet cleaning of Boiler Pressure Part Tubes by HP jet pump & De-slugging of tubes of Boiler. (As per scope of work)
DP test for dissimilar joints, header stubs etc. of boiler tubes. (As per scope of work)
Rectification by replacement of defective tube and bend of boiler pressure part tubes. (Including survey, cutting & lifting/lowering of 30 Nos. module/hangers each of LTSH / Economizer & re-assembly of the same). (As per scope of work)
Fin welding of water wall & SCW tubes (single side welding of fin)
Repairing of furnace ceiling of Penthouse & doghouse. Refractory work in all the areas of boiler. ATT of boiler.(As per scope of work)
Providing SS heat shield in all the erosion prone area of 1st pass & 2nd pass of boiler.
Fabrication of tube bends
Alignment of all S/H, R/H coils and spacers tubes of re -heater and super –heater etc.
Pad welding on the boiler tubes.(As per scope of work)
Part-B (Overhauling of boiler drum, seal trough & soot blowers of Unit # 9, 2x250MW)
Replacement / Repairing of bracing pipe of duct dia. 50mm to 90mm installed in flue gas path up to ESP inlet (all four passes of ESP).
Overhauling of Boiler Drum of U # 9.(As per scope of work)
Complete servicing work of soot blower of Unit # 9
Repairing of cassette baffle economizer / LTSH coil (As per scope of work)
Replacement of baffles plates (directing plates) between Air Pre-heater outlet to ESP inlet (all four passes of ESP). (As per scope of work).
Repairing of FG Duct up to ESP inlet (Just before Honeybee structure of ESP), baffles plates (directing plates), Economizer and APH hopper. Repairing of PA / SA duct. (As per scope of work).
Repairing of expansion joint between outlet damper of APH and EP inlet.
Overhauling of HP/safety valves
Optional Work :-
H.P. joints beyond 2700 Nos.
Fin welding beyond 400 RM.
Replacement of Economizer coil.
Replacement of LTSH coil.
Retention of scaffolding beyond 60 days.
Repairing of FG Duct beyond 300 Sq. M.
M/s Power Tech Engineering Co. (BID ID -5623725)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
TenderSpecificationSTET16.pdf
Tender Documents • 1.60 MB
BOQ_1960048.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .