Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L1 | Accepted-AOC DUE TO L1 RATE | |
| 2 | L2₹6.7 L+₹44,240 (7.10%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance OTHER THAN L1 RATE | |
| 3 | L3₹7.1 L+₹84,895 (13.6%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L3 | Rejected-Finance OTHER THAN L1 RATE |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
13 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA, ASSAM
REPAIRS/MAINT OF VARIOUS CAPACITY DG SETS AT LEKHAPANI UNDER GE LEKHAPANI
2024_MES_641475_2
8773/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E and category b (i)
9 documents required · 9 mandatory
₹500
GE LEKHAPANI
₹12,000
Yes
17 May 2024
21 Mar 2024
16 Apr 2024
21 Mar 2024
13 Apr 2024
30 Mar 2024
Amount
Periodical Maintenance/Servicing /Repairs for diesel Gen set installed at Lekhapani stn for trouble free operation of generator sets and ensuring the serviceability , carrying out minor spares (if any/ settings required for operation of the set shall be carried out without any extra cost for the following capacity Model/ Make by carry out the inspection /work by an authorized dealer of OEM (or) qualified/experienced technician including extra minimum one visit for incspection between the time of PDC. Engine Maintenance (i) Checking the lubricant oil, top up, filters, (ii) Checking the oil level in the oil both air cleaner if required (iii) Checking of alternator, checking/changing fan belt if required, (iv) Checking of circuits of various controls of engine, (v) Cleaning the cylinder head, lever, lube oil ,cooler pins etc, (vi) Draining the fuel filter bowels to remove water/sediments, (vii) Checking and tightening of all external fasteners, (viii) Checking and tightening of all lube and fuel/hose connections, (ix) Checking of air filters, (x) Cleaning of air filter assembly, (xi) Replacement of all external rubber parts, (xii) Arresting all water /lubricant/fuel leakages, (xiii) Checking of all engine parameter and ensuring trouble free performance, (xiv) Removing the U/S spares and fixing of new spares including testing etc , Alternator Maintenance, (i) Checking the lubricant in the bearings, (ii) Checking of the electrical excitation system and repair if required, (iii) Checking of alternater.charging,fan belt checking if required, (iv) Checking of circuits of various connections, (v) Cleaning the slip rings/brushes etc, (vi ) Removing the U/S spares and fixing of new spares including testing etc Control Panel Panel will be maintained for good operation with the existing components. Any components found defective will be replaced and paid under relevant Item of schedule for removing the US spares and fixing of new spares shall be measured as per ground requirement. Note: (i) All repairs/periodical maintenance shall have to be carried out by the authorised service personnel of OEM (or) qualified/experienced technician of DG Sets for checking, identifying the functionality of DG Set and will carry out required preventive maintenance work and ensure smooth functioning of DG sets and connected works . For the following capacity DG Set (a) DG Set of Capacity 125 KVA
(b) DG Set of capacity 40 KVA
(c) DG Set of capacity 30 KVA
(d) DG Set of capacity 20 KVA
(e) DG Set of capacity 15 KVA
(f) DG Set of capacity 5 KVA
Supply in replacement of following spares for carrying out repairs/periodical maintenance of the DG Set, labour cost for replacing & refixing the spares deemed to be included in quoted rate of item No 1 above. (a) Lube oil filter Set required for 5/15 KVA Gen Set
Lub Oil filter set required for 20 KVA Gen set
Lub Oil filter set required for 30/40 KVA Gen set
Lub Oil filter set required for 125 KVA Gen set
Diesel filter set required for 5/15 KVA Gen set
Diesel filter set required for 20 KVA Gen set
Diesel filter set required for 30/40 KVA Gen set
Diesel filter set required for 125 KVA Gen set
Engine gasket with engine oil seal for 5/15 KVA DG Set.
Engine gasket with engine oil seal for 20 / 30/ 40 KVA DG Set.
Engine gasket with engine oil seal for 125 KVA DG Set.
Dry type Air filter element as required for 5/15 KVA Gen set
Dry type Air filter element as required for 20 KVA Gen set
Dry type Air filter element as required for 30/40 KVA Gen set
Dry type Air filter element as required for 125 KVA Gen set
Ignition switch heavy duty with keys
V' Belts for dynamo/fan suitable for capacity upto 125 KVA.
Flexible fuel/Lub oil PVC pipe (steel braided) with suitable banjo bolts of suitable size for capacity upto 15 to 125 KVA.
Coupling rubber for generator set 15 to 125 KVA
Water outlet and inlet hose pipe
Battery connecting copper cable with terminal made of brass
LED phase/ON Off indicator lamp RYB
DG Set diesel tank lock (as per sample) with fixing accessories
Supply and top up coolent oil. Make : Volvo line / Servo / Castrol
Supply and top up engine oil 15W40 grade. Make : Volvo line / Servo / Castrol
Supply and top up of Battery Distilled Water of recommended ph value
S&F in repairs new gasket for manifold to arrest all exhaust leakage for silencer of Genset of capacity upto 125 KVA
Material and labour for repairs to 15/30/40 KVA DG Set alternator and removing the same from engine of DG Set, transporting the same to the work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage with number of turns as required to achieve the required voltage and ampere and re-warnishing with superior quality varnish, drying inside the oven for required duration to remove the moisture content incl exciter coil ,checking of commentator, brushes ,replacement of bearings and reassembling the stator and rotor coil, complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing all as specified and directed.
Remove the unserviceable fuel injector pump, servicing and calibrating including replacing the unserviceable plunger, springs, Injector caps etc all as directed for 15/30/40 KVA DG Set
Disconnecting, dismantling battery charging alternator assembly replacing the unserviceable burnt coil assembly, re-assembling, refixing to engine and testing for satisfactory charging of battery complete all as specified and directed.
Supply and fix (in repair) battery 12V, 130 AH, initial charging, filled with required electrolite/distilled water and fixing/connecting with electric connector cable all as specified and directed. Make : Exide Model : Gen Plus or equivalent as approved
Supply and fixing (in repairs) AVR (Auto Voltage Regulator) suitable for Gen Set 5/15 KVA to 30 KVA/ having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, outpur current 4 A DC voltage regulation +/- 1% average volts, over excitation current tripping fuse protection 4A, fast acting and frequency 50Hz, complete all as specified and directed.
Supply and fixing (in repairs) AVR (Auto Voltage Regulator) suitable for Gen Set 40 KVA to 125 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, outpur current 4 A DC voltage regulation +/- 1% average volts, over excitation current tripping fuse protection 4A, fast acting and frequency 50Hz, complete all as specified and directed.
Supply and fixing (in repair) Digital DG Controller suitable for any type DG Set of any capacity complete and connecting with existing electrical circuit all as specified and directed. Make : Kirloskar Green Model as per existing or equivalent
Supply and fixing (in replacement) CT Coil with CT Ratio 100/5A, 5VA Cl 1.0 accuracy all as per IS 2705-1992 and as specified and directed.
S&F (in replacement) On load change over switch 160 Amps, 415V, AC 50 Hz, front operated handle, totally enclosed in sheet metal enclosure including fixing on wall with suitable accessories and connecting the cable end with suitable size lugs, nuts/bolts/washers etc complete all as specified and directed.
Dismantling, removing the self starter, motor from the engine of following capacity DG sets, opening the self starter body and overhauling/servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and directed for the following DG set:- (a) 5/15/20/30 KVA Genset
(b) 40 KVA Gen Set
(c ) 125 KVA Genset
S&F DG Set Oil pressure sensor assly with fixing accessories suitable for DG Set of any capacity complete all as specified and directed.
S&F Stop solenoid assly with fixing accessories suitable for DG Set of any capacity complete all as specified and directed.
Repair/overhauling of DG set 15/20 KVA, dismantling and removing nuts & bolts electric connections, water connections for the following repairs/overhauling :- (a) Dismantling/opening of complete cylinder head assembly rocker arms assembly piston head assembly sleeves by removing nuts & bolts for repairs complete. (b) Servicing Washing of complete engine parts with kerosene oil. (c) Reassembling of complete engine by tightening of nuts and bolts with replacement of suitable size Bearing set-01, Anabond-01 set, Piston Ring Set-02 Sets, Piston Complete- 02 Nos, Liner - 02 Nos & Gasket set as required complete all as specified and directed
M&L earthing complete with galvanized steel earth plate electrode 600X600X6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr deep connected with and including GI strip 32 x 6 mm upto 7.5 mtr long in 40 mm dia GI pipe light grade by means of nuts, bolts, washers and necessary earth work in any type of soil, PCC (1:3:6) type C1 chamber and RCC cover and watering pipe 20 mm dia medium grade with funnel,earth test point terminal, etc. complete all as specified.
M/s PRABIR ENTERPRISE
M/S S. P. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .