Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16.5 LAdmitted-Finance | -0.11% | ₹16.5 L | L1 | Admitted-Finance |
| 2 | L2₹16.7 LAdmitted-Finance PLOT NO 22 A SWASTISHRIRAJYABHISHEK SHAKE 350 RAMKRUSHNA GODAVARI HOUSING CO OPERATIVE SOCIETY RAMGOPALNAGAR PADEGAON TAL DIST CHHATRAPATI SAMBHAJINAGAR | AURANGABAD | MAHARASHTRA | 423701 | +1.00% | ₹16.7 L | L2 | Admitted-Finance |
| 3 | L3₹17.1 LAdmitted-Finance | +3.00% | ₹17.1 L | L3 | Admitted-Finance |
Tender Value
₹16.6 L
EMD Value
₹16,557
Closing Date
23 Mar 2026, 2:00 pmClosed
Addl CEO
Zilla Parishad Chhatrapati Sambhajinagar
COMPOUND WALL AND OTHER ALLIED REPAIR WORKS, AT PHSC, VILLAGE KASABKHEDA, TQ. KHULTABAD DIST. CHH. SAMBHAJINAGAR
2026_AURAN_1287384_4
ZPCHSN/Works/DPC/PHSC/2441/04
Open Tender
Civil Works
180 days
Tq. Khultabad Dist. Chh. Sambhajinagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹16,557
20 Apr 2026
16 Mar 2026
24 Mar 2026
16 Mar 2026
23 Mar 2026
16 Mar 2026
EXCAVATION FOR FOUNDATION IN EARTH, SOIL OF ALL TYPES, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (LIFT UPTO 1.5 M.) BY MECHANICAL Means
Providing SOLING USING 80 MM SIZE TRAP METAL IN 15 CM. LAYER including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M-10 of trap/ granite/ quartzite/ gneiss metal FOR FOUNDATION AND BEDDING including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying in situ /Ready Mix CEMENT CONCRETE M-20 of trap / granite /quartzite/ gneiss metal FOR R.C.C. WORK IN FOUNDATIONS LIKE RAFT, STRIP FOUNDATIONS, GRILLAGE AND FOOTINGS of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-20 of trap / granite /quartzite/ gneiss metal FOR R.C.C. COLUMNS as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-20 of trap / granite/quartzite/ gneiss metal FOR R.C.C. BEAMS AND LINTELS as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M-20 of trap/ granite/ quartzite/ gneiss metal FOR R.C.C. PARDI of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing in position TMT - FE - 500 BAR REINFORCEMENT OF VARIOUS DIAMETERS for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing SECOND CLASS BURNT BRICK MASONRY with conventional/ I.S. type bricks in cement mortar 1:6 IN FOUNDATIONS AND PLINTH of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
Providing second class BURNT BRICK MASONRY with conventional/ I.S. type bricks in cement mortar 1:6 IN SUPERSTRUCTURE including striking joints, raking out joints, watering and scaffolding etc. Complete
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-15 of trap/ granite/quartzite/gneiss metal FOR COPING TO PLINTH OR PARAPET, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
Providing internal CEMENT PLASTER 20MM THICK in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.
Providing FINE CEMENT FINISH 1.5 MM THICK OVER GREEN PLASTER SURFACE including scaffolding curing etc. complete.
Providing and fixing heavy duty inter locking CONCRETE COLOURED PAVING BLOCKS OF 60 MM THICKNESS of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M15 of trap/ granite/quartzite/gneiss metal FOR FOUNDATION AND BEDDING / STEPS including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fabricating STRUCTURAL STEEL WORK IN ROLLED SECTIONS LIKE JOISTS, CHANNELS, ANGLES, TEES ETC. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Providing and fixing COLOUR COATED ZINCALUME ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) PROFILED SHEETS FOR ROOFING. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre)
Providing and fixing SOLID CORE FLUSH DOOR SHUTTER IN SINGLE LEAF 32 MM THICK decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
Providing and fixing 50 MM. DIA. MEDIUM CLASS G.I.PIPE GATE with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete.
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.
Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing.
Supplying Plain Glass 6mm etc.
Providing and fixing in position, SINGLE SHUTTERED ALUMINIUM EXTRUDED POWDER COATED OPENABLE DOOR of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.Complete
Providing WATER PROOFING TREATMENT as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete TERRACE SLAB WITH BITUMEN FELTS in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 One Square Metre., hot bitumen layer at the rate of 14.50Kilogramper 10 One Square Metre. and over the same layer of bitumen felt of type III grade (I) as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50Kilogramper 10 Square Metre. and finally spreading over it grit at the rate of 14.50Kilogramper 10 Square Metre. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete.
Providing and fixing on WALLS/ CEILING/ FLOOR 15 MM DIA. UPVC PIPE with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on WALLS/ CEILING/ FLOOR 25 MM DIA. UPVC PIPE with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing 15 MM DIAMETER PVC AQUA KRAFT TYPE OF APPROVED MAKE SUPER BIB TAP with flange including all accessories etc complete
Providing and constructing BRICK MASONRY INSPECTION CHAMBER 60CM X 45CM X 90CM including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogramwith frame etc complete.
Providing and fixing 100 MM DIA STABILISER PIPE/ P.V.C. SOIL VENT/WASTE PIPE and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
RWH - SHALLOW PERCOLATION PIT PROVIDING, CONSTRUCTING 2.0M DEEP SHALLOW DEPTH PERCOLATION PIT comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Providing and constructing 75 MM. THICK MODIFIED PENETRATION MACADAM (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 30% CRUSHER BROKEN METAL + 70% HAND BROKEN (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kg/sqm, spreading 12 mm.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. INCLUDING PICKING OF EXISTING WBM SURFACE. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying TACK COAT on the prepared surface heating by fames in Boiler and spraying bitumen with sprayer on Dry / Hungry B.T. surface 3 kg/10 sqm. (VG-30 bulk bitumen rates are considered to arrive at rates)
OPEN GRADED PREMIX SURFACING- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( OVER MPM SURFACE) (VG-30 bulk bitumen rates are considered to arrive at rates)
PROVIDING BITUMINOUS TYPE A LIQUID SEAL COAT ON BITUMINOUS SURFACE including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 KgSqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying TWO COATS OF WALL CARE PUTTY ON PLASTERED SURFACE AND CEILING AND WALLS to prepare surface even and smooth of approved make, etc complete.
Providing and applying PRIMING COAT ON CONCRETE/ MASONARY/ ASBESTOS CEMENT PLASTERED SURFACES including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
Providing and applying PLASTIC EMULSION PAINT of approved quality, colour and shade to old and new surfaces IN TWO COATS including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
Providing and applying TWO COATS OF EXTERIOR ACRAYLIC EMULSION PAINT confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.
Providing and fixing sign boards of size size 60 x 80 cm made out of 14 gauge M.S.Sheet with retro reflective sheeting of Engineering Grade as per M.O.T. specification No. 801-3(1993) white reflective back ground, lettering symbol bordering of black non reflective paint including 3.65 metre long M.S.angle one post of 65 x 65 x 6 mm size duly painted with white and black bands including fixing the boards of M.S. angle with galvanised nuts and bolts and washer. The Board shall be as per IRC-67-1977 including conveying fixing in ground with C.C. 1:4:8 block of size 0.60 x 0.60 x 0.75 m, with 7 year guarantee for the sheeting etc. complete. Mild Steel Board with Engineering Grade.
Please Enable Macros to View BoQ information
SPECIFICATION OF WORKS
EXCAVATION FOR FOUNDATION IN EARTH, SOIL OF ALL TYPES, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (LIFT UPTO 1.5 M.) BY MECHANICAL Means
Providing SOLING USING 80 MM SIZE TRAP METAL IN 15 CM. LAYER including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M-10 of trap/ granite/ quartzite/ gneiss metal FOR FOUNDATION AND BEDDING including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying in situ /Ready Mix CEMENT CONCRETE M-20 of trap / granite /quartzite/ gneiss metal FOR R.C.C. WORK IN FOUNDATIONS LIKE RAFT, STRIP FOUNDATIONS, GRILLAGE AND FOOTINGS of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-20 of trap / granite /quartzite/ gneiss metal FOR R.C.C. COLUMNS as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-20 of trap / granite/quartzite/ gneiss metal FOR R.C.C. BEAMS AND LINTELS as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M-20 of trap/ granite/ quartzite/ gneiss metal FOR R.C.C. PARDI of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing in position TMT - FE - 500 BAR REINFORCEMENT OF VARIOUS DIAMETERS for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing SECOND CLASS BURNT BRICK MASONRY with conventional/ I.S. type bricks in cement mortar 1:6 IN FOUNDATIONS AND PLINTH of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
Providing second class BURNT BRICK MASONRY with conventional/ I.S. type bricks in cement mortar 1:6 IN SUPERSTRUCTURE including striking joints, raking out joints, watering and scaffolding etc. Complete
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-15 of trap/ granite/quartzite/gneiss metal FOR COPING TO PLINTH OR PARAPET, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
Providing internal CEMENT PLASTER 20MM THICK in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.
Providing FINE CEMENT FINISH 1.5 MM THICK OVER GREEN PLASTER SURFACE including scaffolding curing etc. complete.
Providing and fixing heavy duty inter locking CONCRETE COLOURED PAVING BLOCKS OF 60 MM THICKNESS of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M15 of trap/ granite/quartzite/gneiss metal FOR FOUNDATION AND BEDDING / STEPS including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fabricating STRUCTURAL STEEL WORK IN ROLLED SECTIONS LIKE JOISTS, CHANNELS, ANGLES, TEES ETC. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Providing and fixing COLOUR COATED ZINCALUME ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) PROFILED SHEETS FOR ROOFING. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre)
Providing and fixing SOLID CORE FLUSH DOOR SHUTTER IN SINGLE LEAF 32 MM THICK decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
Providing and fixing 50 MM. DIA. MEDIUM CLASS G.I.PIPE GATE with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete.
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.
Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing.
Supplying Plain Glass 6mm etc.
Providing and fixing in position, SINGLE SHUTTERED ALUMINIUM EXTRUDED POWDER COATED OPENABLE DOOR of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.Complete
Providing WATER PROOFING TREATMENT as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete TERRACE SLAB WITH BITUMEN FELTS in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 One Square Metre., hot bitumen layer at the rate of 14.50Kilogramper 10 One Square Metre. and over the same layer of bitumen felt of type III grade (I) as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50Kilogramper 10 Square Metre. and finally spreading over it grit at the rate of 14.50Kilogramper 10 Square Metre. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete.
Providing and fixing on WALLS/ CEILING/ FLOOR 15 MM DIA. UPVC PIPE with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on WALLS/ CEILING/ FLOOR 25 MM DIA. UPVC PIPE with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing 15 MM DIAMETER PVC AQUA KRAFT TYPE OF APPROVED MAKE SUPER BIB TAP with flange including all accessories etc complete
Providing and constructing BRICK MASONRY INSPECTION CHAMBER 60CM X 45CM X 90CM including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogramwith frame etc complete.
Providing and fixing 100 MM DIA STABILISER PIPE/ P.V.C. SOIL VENT/WASTE PIPE and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
RWH - SHALLOW PERCOLATION PIT PROVIDING, CONSTRUCTING 2.0M DEEP SHALLOW DEPTH PERCOLATION PIT comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Providing and constructing 75 MM. THICK MODIFIED PENETRATION MACADAM (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 30% CRUSHER BROKEN METAL + 70% HAND BROKEN (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kg/sqm, spreading 12 mm.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. INCLUDING PICKING OF EXISTING WBM SURFACE. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying TACK COAT on the prepared surface heating by fames in Boiler and spraying bitumen with sprayer on Dry / Hungry B.T. surface 3 kg/10 sqm. (VG-30 bulk bitumen rates are considered to arrive at rates)
OPEN GRADED PREMIX SURFACING- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( OVER MPM SURFACE) (VG-30 bulk bitumen rates are considered to arrive at rates)
PROVIDING BITUMINOUS TYPE A LIQUID SEAL COAT ON BITUMINOUS SURFACE including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 KgSqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying TWO COATS OF WALL CARE PUTTY ON PLASTERED SURFACE AND CEILING AND WALLS to prepare surface even and smooth of approved make, etc complete.
Providing and applying PRIMING COAT ON CONCRETE/ MASONARY/ ASBESTOS CEMENT PLASTERED SURFACES including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
Providing and applying PLASTIC EMULSION PAINT of approved quality, colour and shade to old and new surfaces IN TWO COATS including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
Providing and applying TWO COATS OF EXTERIOR ACRAYLIC EMULSION PAINT confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.
Providing and fixing sign boards of size size 60 x 80 cm made out of 14 gauge M.S.Sheet with retro reflective sheeting of Engineering Grade as per M.O.T. specification No. 801-3(1993) white reflective back ground, lettering symbol bordering of black non reflective paint including 3.65 metre long M.S.angle one post of 65 x 65 x 6 mm size duly painted with white and black bands including fixing the boards of M.S. angle with galvanised nuts and bolts and washer. The Board shall be as per IRC-67-1977 including conveying fixing in ground with C.C. 1:4:8 block of size 0.60 x 0.60 x 0.75 m, with 7 year guarantee for the sheeting etc. complete. Mild Steel Board with Engineering Grade.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
NoBlackListedDeclaration.pdf
PDF • 0.54 MB
SelfDeclarationAffidavitFormat.pdf
PDF • 0.02 MB
DECLERATINFORMAT.pdf
PDF • 0.10 MB
Tendernotice_1.pdf
PDF • 2.19 MB
BOQ_2213668.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid