| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.3 LAccepted-AOC | L-1 | Accepted-AOC BEING LOWEST | |
| 2 | L-2₹8.7 L+₹35,970 (4.29%)Rejected-Finance | L-2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L-3₹9.2 L+₹82,208 (9.80%)Rejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L-3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L-4₹9.5 L+₹1.1 L (13.1%)Rejected-Finance | L-4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L-5₹9.8 L+₹1.5 L (17.4%)Rejected-Finance NO 45 5TH CROSS MALLAPPA LAYOUT BABUSAPALYA KALYAN NAGAR BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L-5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹19,980
Closing Date
17 Sept 2020, 6:00 pmClosed
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIRS TO CHLORONOME PLANTS/RO PLANTS AT VARIOUS LOCATION UNDER GE (AF) MARATHAHALLI BANGALORE
2020_MES_372518_1
GE (AF) MARATHAHALLI / 8851 / E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) MARATHAHALLI
Class E above and Category a(II)
7 documents required · 7 mandatory
₹500
Yes
GE (AF) MARATHAHALLI
₹19,980
Yes
GE (AF) MARATHAHALLI
18 Dec 2020
27 Aug 2020
19 Sept 2020
27 Aug 2020
17 Sept 2020
31 Aug 2020
27 Aug 2020 - 31 Aug 2020
31 Aug 2020
Amount
Servicing of water treatment plant (RO) by checking all parts, cleaning and backwashing of filter media of all units/membrane, arressting of leakages and checking quality of water and keeping the plant in serviceable condition to provide the acceptable quality standrad parameters as required all as specified by manufactures and directed. WATER TREATMENT PLANT CONSISTS OF THE FOLLOWING :- (a) MEDIA FILTER (FRP) - 02 NOs (b) ACTIVATED CARBON FILTER (FRP) - 02 NOs (c) WATER SOFTNER FILTER (FRP) - 02 NOs (d) CONTROL PANEL - 02 NOs NOTE :- (a) Servicing shall be carried out through authorised service personal/agency and necessary certificate to be submitted as proof of having carried out the services. (b) Carry out water analysis test regarding chemicals & biological test report from Karnatka Govt. agencies as directed and test report shall be submitted. (c) Un serviceable spares which are required to be replaced shall be carried out and paid separetly under relevant items.
Taking down U/S membarane & Supply and fix RO membarane (8040) suitable for 750/1000 ltrs per hr water ( Vayu Vihar and SDI )
Taking down U/S membarane & Supply and fix RO membarane suitable for 15000 ltrs per day water capacity.(ASTE)
Taking down damanged/ unserviceable Ultra Voilet system from position, material and labour for new UV system suitable for RO plant capacity of 750/1000 LPH.(SDI and Yavu Vihar)
Taking down damanged/ unserviceable Ultra Voilet system from position, material and labour for new UV system suitable for RO plant capacity of 15000 ltrs/day (ASTE)
Taking out existing perished Filter/water micron catridge 5 micron HD - 05 of RO Plant capacity 750 Ltr/Hr from the position, material and Labour for suitable Filter/water micron catridge 5 micron HD - 05 for RO Plant of suitable for 750 Ltrs/Hr capacity complete with fixing arrangement all as specified and directed.
Taking out existing perished Filter/water net 5 micron HD - 05 of RO Plant capacity 750 Ltr/Hr from the position, material and Labour for suitable Filter/water net 5 micron HD - 05 for RO Plant of suitable for 750 Ltrs/Hr capacity complete with fixing arrangement all as specified and directed.
Taking down U/S Rotto meter & Supply and fix RO Rotto meter suitable for 750/ 1000 LPH and 15000 ltrs per day water capacity.(ASTE)
Materials and labour for servicing of Mono Block pump/SS monobock pump 0.5 to 2 HP, opening the pump and re- fixing, machining the pump impeller shaft key ways, and materials and labour for replacing the key, impeller nut gland packing, gland nuts and coupling as per existing size including re-fixing the same to the original position and commissioning testing complete all as specified and directed.
All as per item No. 9 here-in-before but 3 HP pump.
All as per item No. 9 here-in-before but 5 HP pump.
Disconnecting the monoblock pump of capacity 0.5 HP to 2 HP from position, strip opening the motor, taking out the burnt copper winding wire from slots cleaning the slots , rewinding the motor with suitable guage of copper wire, insulating and varnishing, heating and refixing the motor with proper alignment with pump set connecting up the electric connections testing and commissioning complete.
All as per item No 12 here-in-before but 3 HP Motor
All as per item No 12 here-in-before but 5 HP Motor
Taking down old u/s control panel & Supply and fix control panel of RO plant suitable for 750 ltrs per hr water capacity.( Vayu Vihar)
Supply citric acid Monohydrate for regeneration of RO Plant Membrane
Taking down unserviceable Air Break (Power) Contactor 3TF 32 00-0A and Supply & fix Air Break (Power) Contactor 3TF 32 00-0A automatic suitable for 5 HP pump set complete all as specified and directed. Make:- SIEMENS or equivalent.
Supply only calcium based granular high strength chlorine suitable for drinking water treatment.
Maintenance/repair/servicing of Chloronome Granules dozing pump including combined gear motor and agitator excellent proportional control and injection electric motor 0.5 HP capacity and cleaning of inlet & outlet UPVC pipes all as specified & directed. Note: (i) Un serviceable spares which are required to be replaced shall be carried out and paid separetly under relevant items.
Supply only Activated carbon suitable for Water Treatment Plant (RO) including taking out existing unserviceable carbon all as specficied and as directed.
Taking down damaged UPVC clamp from position and Material and labour for new PVC clamps suitable for 63mm bore HDPE pipe complete with provision for 25mm dia for pressure guage branch connection and socket nipple, clamp all as specified and directed.
Taking down damaged / unserviceable pressure gauge, material and labour for new pressure guage 25mm bore with pressure rating as required all as specified and directed.
Taking down unserviceable UPVC pipe of size 90 mm bore from position and material and labour for UPVC pipe of size 90 mm bore and pressure capacity 6Kg/cm² all as specified and directed.
All as per item No-23 here-in - before but size 65 mm bore.
All as per item No-23 here-in - before but size 25 mm bore.
All as per item No-23 here-in - before but size 20 mm bore.
All as per item No-23 here-in - before but size 15 mm bore.
Taking down unserviceable multiport valve from position of size 65mm, material and labour for multiport valve of size 65mm suitable for UPVC pipe all specified and directed.
Taking down unserviceable water purifier system of capacity 8/16/25/60 Ltrs from the position for servicing, repairs replacement of defective components/parts and reassembling with testing and complete all as specified and directed. NOTE :- Spare will be measured and paid separetly.
Supply only booster pump OF CAP 0.5 hp
Supply only sediment filter 10 Micron
Supply only electrical controller/PCB
Supply only antiscalent agent
Supply only PH boosting chemical.
Material and Labour for chemical cleaning of RO system using suitable chemical all as directed.
B5BUILDING SOLUTIONS
GKR and CO
J PUSHPALATHA ENGINEER AND CONTRACTOR
M/S Suresh Raju
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .