| 1 | L1₹1.9 CrAccepted-Finance | ₹1.9 Cr | L1 | Accepted-Finance Accept |
| 2 | L2₹2.2 Cr+₹25.5 L (13.4%)Accepted-Finance | ₹2.2 Cr+₹25.5 L (13.4%) | L2 | Accepted-Finance Accept |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S SURYA ELECTRICALS L1 | SATYA SAI BUILDERS & CONTRACTORS L2 |
|---|---|---|---|---|---|
| 1.00Providing and Errection of 33KV 6Way RMU at Independent 33KV Society Consumers supply from 220 KV GIS Substation Sector 129, Noida for better supply under EUDD 2 Noida | |||||
| 2.00Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 3 to 4 | |||||
| 3.00 | 33KV HT 3X300SQMM XLPE CABLE | 1 | Mtr. | 10 ₹1,000 Lowest | 10 ₹1,000 Lowest |
| 4.00 | 33 KV OUTDOOR JOINTING KIT XLPE 3X300 Sqmm | 1 | Nos | 20 ₹120 Lowest | 50 ₹300 |
| 5.00Errection of above Centralised material and Supply and errection of the below De-Centralised material for completing the works as per RESPO. | |||||
| 6.00 | MAKING AND FIXING OF 33KV OUTDOOR TERMINATION KIT SUITABLE FOR 3X300SQMM XLPE CABLE WITH HELP OF JOINTER AND OTHER REQUIRED MATERIAL AND COMPLETE CONNECTIONS IN ALL RESPECT. | 1 | Job | 2,500 ₹15,000 Lowest | 4,000 ₹24,000 |
| 7.00 | FIXING AND CONNECTION OF RMU BY 33KV HT 3X300SQMM CABLE AS PER SITE REQUIREMENT WITH COMPLETE WORK IN ALL RESPECT. | 1 | Mtr | 100 ₹10,000 Lowest | 200 ₹20,000 |
| 8.00SUPPLY AND INSTALLATION OF RMUs AT PRIMARY SUBSTATION GIS 220KV SECTOR-129 NOIDA FOR UN-INTERUPTTED SUPPLY | |||||
| 9.00 | SUPPLY, INSTALLATION AND PROPER COMMISSIONING OF 33KV, 630 Amps. & extensible, outdoor duty 6-way, fully motorised and manually operated Ring main unit (2 LBS+4 VCB/SF6) consisting of copper busbar in SF6/AIR insulated. RMU should be type tested for internal arc of 25 KA for 1 Sec. for Gas tank, Ingress protection (outdoor) IP54 and cable chamber with AFLR classification and gas to be from rear bottom of the switchgear away from the operator to ensure safety of the operating personnel. Suitable CT with microprocessor based numerical over current relay (IDMTL + Inst.) for Protection to be provided with VCB Feeder with right angle boot for termination Kits Or similar technology. Hermitically sealed stainless steel switching chamber. All the necessary wirings and Dummy panel /space for FRTU to be given along with RMU for future compatibale easy integration with SCADA networks. (Supply of FRTU is not in scope) Aux. PT, Battery, Charger etc. for Motorised operation by remote control. Circuit Breaker protection using a wide range of self-powered and auxiliary relays. Accessible cable Earth & Test Facility at the front of the unit. The scope is including Plinth and Angle iron Stand as per OEM design complete in all rescept as per the direction of Engineer incharge. Complete RMU and its accessories. ( Makes: ABB / Siemens / Eaton / Schneider/Lucy/any other make approved in UPPCL) FOR 33KV BAY with complete work in all respect. | 1 | Nos. | 58,00,000 ₹58,00,000 Lowest | 65,00,000 ₹65,00,000 |
| 10.00 | Construction of Plinth of size 6'x3'x3' (LxWxH) for above RMUs complete in all respect. | 1 | Job | 2,45,000 ₹2,45,000 Lowest | 2,50,000 ₹2,50,000 |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
16 Sept 2025, 12:00 pmClosed
Superintending Engineer
Office of the S.E., EUDC-II, Sec-18 (Ansal) Noida
02 No. of work related to supply and installation of 33kV RMU under the item of strengthening and protection related work of 33/11kV substations in the area of EUDC-II, Noida under Business Plan 2025-26
2025_PVVNL_1070923_1
E-Tender No. 38/2025-26, EUDC-II, Noida.
Open Tender
Electrical Works
Item Rate
45 days
Office of the S.E., EUDC-II, Sec-18 (Ansal) Noida
Attached in DOC
2 documents required · 2 mandatory
₹5,900
S.E., EUDC-II, Noida.
₹1.9 L
25 Sept 2025
3 Sept 2025
16 Sept 2025
3 Sept 2025
16 Sept 2025
3 Sept 2025
Amount
Providing and Errection of 33KV 6Way RMU at Independent 33KV Society Consumers supply from 220 KV GIS Substation Sector 129, Noida for better supply under EUDD 2 Noida
Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 3 to 4
33KV HT 3X300SQMM XLPE CABLE
33 KV OUTDOOR JOINTING KIT XLPE 3X300 Sqmm
Errection of above Centralised material and Supply and errection of the below De-Centralised material for completing the works as per RESPO.
MAKING AND FIXING OF 33KV OUTDOOR TERMINATION KIT SUITABLE FOR 3X300SQMM XLPE CABLE WITH HELP OF JOINTER AND OTHER REQUIRED MATERIAL AND COMPLETE CONNECTIONS IN ALL RESPECT.
FIXING AND CONNECTION OF RMU BY 33KV HT 3X300SQMM CABLE AS PER SITE REQUIREMENT WITH COMPLETE WORK IN ALL RESPECT.
SUPPLY AND INSTALLATION OF RMUs AT PRIMARY SUBSTATION GIS 220KV SECTOR-129 NOIDA FOR UN-INTERUPTTED SUPPLY
SUPPLY, INSTALLATION AND PROPER COMMISSIONING OF 33KV, 630 Amps. & extensible, outdoor duty 6-way, fully motorised and manually operated Ring main unit (2 LBS+4 VCB/SF6) consisting of copper busbar in SF6/AIR insulated. RMU should be type tested for internal arc of 25 KA for 1 Sec. for Gas tank, Ingress protection (outdoor) IP54 and cable chamber with AFLR classification and gas to be from rear bottom of the switchgear away from the operator to ensure safety of the operating personnel. Suitable CT with microprocessor based numerical over current relay (IDMTL + Inst.) for Protection to be provided with VCB Feeder with right angle boot for termination Kits Or similar technology. Hermitically sealed stainless steel switching chamber. All the necessary wirings and Dummy panel /space for FRTU to be given along with RMU for future compatibale easy integration with SCADA networks. (Supply of FRTU is not in scope) Aux. PT, Battery, Charger etc. for Motorised operation by remote control. Circuit Breaker protection using a wide range of self-powered and auxiliary relays. Accessible cable Earth & Test Facility at the front of the unit. The scope is including Plinth and Angle iron Stand as per OEM design complete in all rescept as per the direction of Engineer incharge. Complete RMU and its accessories. ( Makes: ABB / Siemens / Eaton / Schneider/Lucy/any other make approved in UPPCL) FOR 33KV BAY with complete work in all respect.
Construction of Plinth of size 6'x3'x3' (LxWxH) for above RMUs complete in all respect.
PROVIDING AND INSTALLATION OF CHEMICAL EARTHING FOR ABOVE RMUs (WITH ALL MATERIAL AND LABOUR) AFTER INSTALLATION RESISTANCE SHOULD BE LESS THAN ONE OHM. AS PER FOLLOWING (The all material and labour shall be provided by the contractor with 12 month guarantee for resistance value less than one OHM.)
Chemical Earthing of Installed RMU as per site requirement as per specification.
Providing and fixing of GI strip of size 32 mm x 6 mm suitable for RMUs installed at Above 33/11 KV Substation .
Providing and fixing of PVC Pit covers for above earthing electrode terminals.
Providing and Errection of 33KV 6Way RMU in 33KV Bay No. 12 supply from 220 KV GIS Substation Sector 129, Noida for better supply under EUDD 3 Noida
Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No.17
33KV HT 3X300SQMM XLPE CABLE
Errection of above Centralised material and Supply and errection of the below De-Centralised material for completing the works as per RESPO.
FIXING AND CONNECTION OF RMU BY 33KV HT 3X300SQMM CABLE AS PER SITE REQUIREMENT WITH COMPLETE WORK IN ALL RESPECT.
SUPPLY AND INSTALLATION OF RMUs AT PRIMARY SUBSTATION GIS 220KV SECTOR-129 NOIDA FOR UN-INTERUPTTED SUPPLY
SUPPLY, INSTALLATION AND PROPER COMMISSIONING OF 33KV, 630 Amps. & extensible, outdoor duty 6-way, fully motorised and manually operated Ring main unit (2 LBS+4 VCB/SF6) consisting of copper busbar in SF6/AIR insulated. RMU should be type tested for internal arc of 25 KA for 1 Sec. for Gas tank, Ingress protection (outdoor) IP54 and cable chamber with AFLR classification and gas to be from rear bottom of the switchgear away from the operator to ensure safety of the operating personnel. Suitable CT with microprocessor based numerical over current relay (IDMTL + Inst.) for Protection to be provided with VCB Feeder with right angle boot for termination Kits Or similar technology. Hermitically sealed stainless steel switching chamber. All the necessary wirings and Dummy panel /space for FRTU to be given along with RMU for future compatibale easy integration with SCADA networks. (Supply of FRTU is not in scope) Aux. PT, Battery, Charger etc. for Motorised operation by remote control. Circuit Breaker protection using a wide range of self-powered and auxiliary relays. Accessible cable Earth & Test Facility at the front of the unit. The scope is including Plinth and Angle iron Stand as per OEM design complete in all rescept as per the direction of Engineer incharge. Complete RMU and its accessories. ( Makes: ABB / Siemens / Eaton / Schneider/Lucy/any other make approved in UPPCL) FOR 33KV BAY with complete work in all respect.
Construction of Plinth of size 6'x3'x3' (LxWxH) for above RMUs complete in all respect.
PROVIDING AND INSTALLATION OF CHEMICAL EARTHING FOR ABOVE RMUs (WITH ALL MATERIAL AND LABOUR) AFTER INSTALLATION RESISTANCE SHOULD BE LESS THAN ONE OHM. AS PER FOLLOWING (The all material and labour shall be provided by the contractor with 12 month guarantee for resistance value less than one OHM.)
Chemical Earthing of Installed RMU as per site requirement as per specification.
Providing and fixing of GI strip of size 32 mm x 6 mm suitable for RMUs installed at Above 33/11 KV Substation .
Providing and fixing of PVC Pit covers for above earthing electrode terminals.
Replacement of Jarjar 33 KV 3x400 Sqmm XLPE Cable and 33 KV 3x300 Sqmm XLPE Cable for Eco City, Imperial Housing & Purvanchal Society, Sector-137, Noida Under EUDD-III, Noida
Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No.29 to 32.
33 KV 3x400 Sqmm XLPE Cable
33 KV 3x300 Sqmm XLPE Cable
33 KV Outdoor Jointing Kit for 3x400 Sqmm Cable
33 KV Outdoor Jointing Kit for 3x300 Sqmm Cable
Errection of above Centralised material and Supply and errection of the below De-Centralised material for completing the works as per RESPO.
Supply of 140mm OD PN-6-PE-80, 6" Dia Grade UV Stabilized HDPE Pipe.(PVVNL GTP APPROVED)
Drilling of dia 220 mm in bores for Double Curcuit by trenchless method by horizontal boring machine at a depth of 1.50 mtrs to 2.50 mtrs. (as per site requirement) below the ground level for 3x300Sqmm and 3x400sqmm XLPE Cable at Kaccha/Pakka Road/Road Crossing/as per site requirement with complete work in all respect as per RESPO. Road Restoration charges shall be inclusive in quoted rates.
Laying and interconnecting of above HDPE Pipe PE-80, PN6, DN-140mm, 6" dia by HDD trenchless method for HOSTING OF 33 KV 3x300sqmm and 3x400sq.mm XLPE cable in Double Circuit with complete work in all respect.
Laying, Hosting and commissiong of 33 KV 3x300sqmm and 3x400sq.mm XLPE Cable Double Ckt. Cable in HDPE Pipe in HDD trenchless method with complete work in all respect.
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor) Road Restoration charges shall be inclusive in quoted rates.
Preparation, Making and Fixing of 33 KV Power Cable ends: Fixing and Making of 33 KV 3x300sqmm and 3x400sq.mm XLPE Heat shrinkable outdoor jointing kits suitable for 33 KV 3x300sqmm and 3x400sq.mm XLPE after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
Laying and Loopping of 33 KV 3x300sqmm and 3x400sq.mm XLPE Cable Double Ckt. in the air on cable Riser Double Pole existing trench cable trench with G.I.Pipe and making connection complete at both ends. Road Restoration charges shall be inclusive in quoted rates.
Dismentaling of old and Damaged 33 KV 3x300sqmm and 3x400sq.mm XLPE underground cable from the different sites at kacha/pakka road and Safe carriage of its from site to any PVVNL Store including loading and unloading both ends. Pakka Road Resotration Charges in the scope of contractor.
SATYA SAI BUILDERS & CONTRACTORS (BID ID -5538233)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .