GE (I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR / MAINT OF MRS GRID STATION, MRS BHALRA AND MRS CHINTA AT BHALRA MIL STN UNDER GE (I) 873 EWS
2022_MES_548290_1
NIT-46 OF 22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) 873 EWS
₹20,000
Yes
12 Oct 2022
27 Aug 2022
29 Sept 2022
27 Aug 2022
26 Sept 2022
12 Sept 2022
Amount
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and as directed.
Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade including taking up of old unserviceable insulator complete all as specified and directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 95 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 120 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 185 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Maintenance and complete overhauling of 11 KV,3 phase, 630 Amps - 400 Amps, VCB including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 including reassembling, panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components complete, all as specified and directed by Engr-in-Charge. make of VCB:- ABB Note:- Spare parts will be measured and paid seperately as supply only under respective items. The labour charges deemed to be included in the unit rate quoted for this item.
Supply only holding catch assembly complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only push button Bracket assembly complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only charged/discharged indicator assembly complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only big and small gear assembly complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only closing spring assembly complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only triping spring assembly complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only trip shaft assembly with spring and trip strips complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only close shaft assembly with spring and close strips complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only TNC switch complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only trip catch assembly with all linkage complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only over current/Earth fault relay Numerical 3 Pole,OC/EF Protection Relay complete for 11 KV VCB, all as specified and directed by Engr-in-Charge. Model:- ADR 131A Make:- ASHIDA, aux. 24-230 VAC/DC, CT:1A/5A
Supply only trip Coil 110 V, DC complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only control fuses rating 3A to 8Amp HRC type complete for 11 KV VCB, all as specified and directed by Engr-in-Charge. Make: RBCO/GE/L&T
Supply only indication lamps comparising CB ON, CB OFF, Spring charge, trip cuircuit indicators etc.Capacity 3 V DC complete for 11 KV VCB, all as specified and directed by Engr-in-Charge. Note:- Colour code as per existing (R,Y,B,G,W) Make: Siemens/ Kaycee/L&T
Supply only isolating Contact assembly upto 800 Amp complete for 11 KV VCB, all as specified and directed by Engr-in-Charge.
Supply only CT unit 100/50/5A, 15 VA 50 Hz suitable for 11 KV VCB Make : L&T, Schenider, CG, Kirloskar & ABB
Supply only master trip relay for 11 KV VCB complete, all as specified and directed by Engr-in-Charge.
Supply only auxilary relay for 11 KV VCB complete, all as specified and directed by Engr-in-Charge.
Supply only hooter red colour for 11 KV VCB complete, all as specified and directed by Engr-in-Charge.
XLPE copper cable 2.5 sqmm 4 core complete, all as specified and directed by Engr-in-Charge.
XLPE copper cable 2.5 sqmm 8 core complete, all as specified and directed by Engr-in-Charge.
Supply only Ferrules 0 to 9 suitable for 11 KV VCB complete all as specified
Supply only Ferrules A to Z suitable for 11 KV VCB complete all as specified
Material and Labour for disconnecting electrical connection, removing of defective 33 KV Vaccum Circuit Breaker conforming to IS - 13118/IEC:56 of 36 KV, 1250 Amps, 3 Phase, 50 Hzs having breaking capacity of 25 KA, Shunt trip 110 volts DC alongwith repair of its mechanism at site with cleaning of all contacts, bushes, terminals, spring charging mechanism, greasing of all moving parts, checking of function & physical servicibility of CT, PT, Protection relays, tripping system with coils, spring charging, breaker operating mechanism and reasserbling of breaker complete as specified and directed. Note:- Spare parts will be measured and paid seperately as supply only under respective items. The labour charges deemed to be included in the unit rate quoted for this item.
Supply only Over Current and Earth Fault relays operating voltage of 36 volts for 33 KV VCB complete all as directed.
Supply only master Tripping Relay operation voltage of 36 volts complete for 33 KV VCB all as directed.
Supply only Spring charging motor for complete for 33 KV VCB all as directed. Make : GEC / Crompton
Supply only Tripping and Closing coils complete for 33 KV all as directed.
Supply only TNC Switch complete for 33 KV all as directed.
Disconnecting PT Set and Supply and fixing new 33 KV single phase out door oil cooled PT of ratio 33 KV/110 V Set complete all as directed.
Disconnection CT Set and Supply and fixing new 33 KV, single phase, out door oil cooled CT of ratio 400/55 Amp, class 1.0/5, burden 15VA in replacement of old CT Set complete all as directed.
S&F in replacement of batteries(cell) of 2 volts of capacity 100 AH suitable for battery bank including initial Dry battery complete as per specification including necessary cell connectors, nuts, bolts and washers etc and copper control cable for DC supply complete, all as specified & directed by Engr-in-Charge. Make: Exide / Amron
Material and Labour for disconnecting electrical connection, removing of defective 3.15 MVA transformer at site including disconnecting and rewinding of 33/11 KV, Three Phase, 4 wire, 50 Hz vector group DYn 11 transformer with paper insulated copper winding wire as per original data on HV (Delta connection) and LV (Star connection) & tapping brought on HV side for tap charger to change (±) 2.5%, 5%, 7.5% by means of manually operated off load tap changing gear complete rewinding of HV on three limbs providing insulation material like spares, wooden blocks, cotton tape etc and re-conditioning three limbs complete ovening, replacement of cock sheet packing, vent diafragm replacement of LT terminal plate, breather, filling of new transformer oil for top up with existing oil after proper filtration upto level of 45 KV at 2.5mm gap dielectric strength and testing of transformer at site after connecting electrical connection in full load , complete all as specified & directed. Note : (a) The repair to the Transformer shall be done at site and the contractor shall make all the necessary arrangements required at site. (b) Spare parts will be measured and paid seperately as supply only under respective items. The labour charges deemed to be included in the unit rate quoted for this item.
Supply only following Items / Spares required for 3.15 MVA transformer :-
Supply only gasket suitable for 3.15 MVA transformer complete all as directed.
Supply only 33 KV Digital Voltmeter complete all as directed.
Supply only 33 KV Digital Amp Meter complete all as directed.
Supply only 33 KV Buchholz Relay model GOR-3 complete all as directed.
HT coil/ LT coil of suitable gauge of paper insulated copper winding wire of transformer
LT Bush with rod of brass complete cork washer with nuts, bolts and washers of brass of requisite size suitale for 3.15 MVA transformer
HT Bush with rod of brass complete cork washer with nuts, bolts and washers of brass of requisite size suitale for 3.15 MVA transformer
LT terminal plate for outgoing connections for 3.15 MVA transformer
Breather for transformer of capacity 3.15 MVA
Supply, filling and top up with new Transformer Oil of dielectric strength more than 50 KV at 2.5mm gap confirming to IS : 335-1993 complete all as specified and as directed. Make : APAR Oils / Savita
Dehydration of transformer oil by using filtration plant of suitable capacity and removing the moisture / dust till obtaining the oil dielectric strength 45 KV at 2.5mm gap and above for various transformer / voltage stabilizer of any size located at different substations, complete all as specified & directed.
Spray Painting of complete 3.15MVA Transformer with one coat of weather proof grey synthetic enamel paint after cleaning / removing dust, rust or carbon etc. including writing MES No / SM No complete all as specified and as directed.
Lightning arrestor expulsion type consisting of multiple spark gaps in series with one or more non linear resister to limit voltage surge on AC power circuit ti interrupt power flow current suitable for outdoor installation and exposed to direct sun with ambient temperature -10 degree C to +50 degree C suitable for surge discharge capacity 65 KA, 33000 volts grade conforming to IS 4350 complete with all fittings, including taking down old unserviceable arrestor, complete all as specified and directed.
Synthetic rubber insulated mats 2.5mm thick for voltage upto 33KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2m x 1m, complete all as directed. Make: Jyoti/Jaipuria
Spreading and levelling 20mm graded crushed stone aggregate on floor in MRS Bhalra, complete all as directed by Engr-in-Charge.
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots, removing small bushes etc. and applying two coats of dry distemper, white or tinted on walls, complete all as specified
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
SWASTIK TRADERS
Bidder Name
SWASTIK TRADERS
darshan kumar gandhi
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .