| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC 712 GORAKHPUR JABALPUR 482001 MP | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹45.2 L+₹1.4 L (3.12%)Rejected-Finance 14 L N Y MARKET RANJHI JABALPUR MP 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹46.5 L+₹2.6 L (6.01%)Rejected-Finance PLOT NO 12 SAKAR GRAH NIRMAN SOCIETY TILHARI MANDLA ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MP | 482001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹46.6 L+₹2.8 L (6.34%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹48.5 L+₹4.6 L (10.6%)Rejected-Finance HOUSE NO E 1 PANCHSHEEL NAGAR NARMADA ROAD JABALPUR MP 482002 | JABALPUR | MADHYA PRADESH | 482002 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
14 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
SPL REPAIR TO BLDG NO 2 AT (APS NO 2) AT JAK RRC UNDER GE (WEST) JABALPUR
2021_MES_497109_1
8402/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹94,000
Yes
21 Feb 2022
24 Dec 2021
17 Jan 2022
24 Dec 2021
14 Jan 2022
31 Dec 2021
25 Dec 2021 - 29 Dec 2021
60 days
Amount
Dismantling of timber scantlings unframed 40SqCm and over in section, in any position
Dismentling timber scantlings under 40 Sq. Cm in section as in rafters, purlins, unframed work etc. all as specified.
Dismantling of asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
S&F Pre-painted galvalume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws etc all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws etc as specified and directed.
M & L providing, cement concrete type B1 1:2:4 (20 mm graded aggregatet) in roof kerbs or mud stops, rounded or chamfered on edges
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets including E- Grid frame work complete all as specified and directed.
S&F suspended false ceilingwith T- grid system of size 600 x 600mm with following specifiactions :- (i) Pre primed, self embossed, textured designer board, water resistant, termite resistant, fire resistant for insulation Calcium Silicate Boards 8mm thick (ii) GI powder coated Main Tee of size 38x24mm made out of 0.30 mm (min) thick sheet (ii) GI powder coated Cross Tee of size 24x24x0.30 mm (min) made out of 0.30 mm (min) thick sheet (iii) GI powder coated angle of size 24x24x0.30 mm (min) made out of 0.30 mm (min) thick sheet (iv) Level clip / suspension wire - 4 mm dia GI wire. (v) Soffit cleat/Rawl Plug as per manufacturers instrcutions (vi) Fixing shall be executed as per manufacturers instructions
Dismantling structural steel (as in wind tie or other on the AC Sheet)
S & F hand rails, half ruond or other stock section or core for woodenhand rail starigt portion drilled and countersunk for balusters running bars for door balusters nosing to steps inculuding embeding in concrete and screwing etc. Wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets(for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.' and similar work conforming to Fe-290 Gde E-165.
M&L for rolled mild steel sections in rafters, purlins and posts etc where connected to common rafters and runnuing rails fixed with angle cleats or other connecting plates and nut, bolts etc. confirnimg to Fe-410 (Gde E-250).
S&F 5 to 10mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other end, or screwed both ends, each screwed and to fitted with washers and one hexagonal or square nut exc 5 cm and n exc 10 cm
S&F 11 to 15mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other end, or screwed both ends, each screwed and to fitted with washers and one hexagonal or square nut exc 10 cm and n exc 15 cm
Forming jambs, etc to openings (to foregoing item), including cutting toothing and properly bonding into old work, also facing, jointing and pointing to match existing work with cement mortar 1:6 complete all as specified
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc
M&L for rendering15 mm thick in two layers(10mm thick in CM 1:6 & 5mm thick in CM 1:4 with water proofing compound and finished even and smooth without using extra cement. Note :- WPC shall be measured and paid seprately.
Supply only Integral Water proofing compound.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM in 1:6 finished even and fair without using etra cement.
M&L for 75 mm thick PCC (1:3:6) ty C2 using 40mm graded stone aggregate as in plinth protection.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles
M&L for brick work with Fly Ash bricks built in cm (1:6) straight or curved on plan exceeding 6 mtr mean radius with all as specifie and directed
M&L for brick work with Fly Ash bricks built in CM 1:4, straight or curved on plan exceeding 6 M mean radius bricks in half brick thick wall etc.
M & L for preparation of Old steel surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint complete all as specified and as directed.
M & L for preparation of Old wooden surfaces of any description over 10 cm width or girth & applying one coat of synthetic enamel paint complete all as specified and as directed.
Hacking out old broken glass(any thickness, size, quality or description) from wooden/steel frames, glazed with putty or fixed with beads complete all as specified and as directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in a square n exc 0.5 Sq m in each pane upto three storey of bldgs
S&F 3mm thick figured glass, pin head type and glazing with oil putty in a square n exc 0.5 Sq m in each pane upto four storey of bldgs
S&F galvanised MS wire cloth, 0.56mm nominal dia of wire average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples beads or in steel window complete all as specified and directed by Engr-in-charge.
Complete removal of existing treatment on walls including steel wire brushing and scraping etc or preparation of new platered surfaces of wall and applying 2mm thick( Avg) Birla wall care putty in two layers on wall surfaces including rubbing, levelling and preparing the surfaces for receiving further finishes as directed.
M&L for applying two coat of distemper Oil emulsion white or tinted on new putty surfaces of wall complete all as specified and directed.
M&L for 02 coats of cement base paint on walls incl preparation of surfaces on plastered or on plastered new surfaces.
M & L for preparation of walls old plastered surfaces & applying two coats of cement based paint .
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M & L for Cement concrete type B-1, 1:2:4 (20mm graded aggregate), 25 mm thick as in floor bedding
M&L for vetrified ceremic tiles 10 mm thick, in light shade, (Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specfied and directed.
Dismantling floor, hearth or wall tiling in-cluding cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for coloured Glazed ceramic tiles in vertical serfaces 350 x 250 x 7mm / 450 x 350 x 7mm set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces as backing for tiles.
S & F for Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F anodised aluminum window and ventilator shutters, fixed type without sash bars, aluminium section weighing 0.55 Kg/ Sqm including necessary jointing cleats, glazing clips, ruber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
M&L for two coats of french polishing on new wooden surfaces/old undecorated surface of any description, width or girth including cleaning and preparation of surfaces including a coat of wood filler complete all as specified and directed.
M&L for removing old paint by paint removers or burining off by blow lamps and cleaning with scrapers, any number of coats, any width or girth
Cutting grooves in brick wall,75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 all as specified and directed.Note :- Galvanised steel wire netting shall be measured and paid under relevent items
S&F galvanised steel wire of mesh in size 12mm ,1.4 mm nominal dia of wire and fixed with tinned tack ,or galvanised wire staples.
S&F TMT bars 6mm to 8mm dia, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia.
Taking down chowket or frame with shutter (without taking of shutters from the frames) area not exceeding 1.5 Sq mtr each
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in a square n exc 0.5 Sq m in each pane upto three storey of bldgs
Taking down carefully any type point wiring (light, fan, socket bell or power) , complete with fitting such as switches ceiling roses,lamp holders sockets,regulators,call bell light fitting with PVC conduit surface /concealed or wooden pattens including sunken cast iron /pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces all as specified and directed by Engineer in charge.
Taking down the ceiling fan in situ and refixing after servicing, repairing and painting to ceiling fan including scratching old paint and preparation of surface for painting with one coat of white/grey enameled paint complete all as specified and directed.
S&F in repair Sub Main Wiring two single core PVC insulated cable of size 6.0 Sqmm multistranded copper conductor one run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and two run of 4.0 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :-Two of 6.0 Sqmm Wire and one No of 4.0 Sqmm Earth wire in One RM length Measured as one unit length.
S&F in repair Sub Main Wiring with two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 20mm dia with all conduit fitting,fixing accessories and 2.5 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :- Two Nos of 4.00 Sqmm Wire and One No of 2.5 Sqmm Earth wire in One RM length Measured as one unit length.
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
(a) One light/fan point controlled by one switch.
(c) One socket point controlled by one switch on same board.
(c) One socket point controlled by one switch on Independent board.
Ditto all as per above items but with 1100 volts grade copper standard conductor cable of size 2.5 Sqmm with 1.5 Sqmm solid copper conductor PVC for 3 pin switch socket outlet15 Amp independent board complete all as specified and directed by Engineer in charge .
S & F Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
S & F Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F switch socket combination 3 pin 5 and 16 Amps AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F fan regulator Step type of polycarbonate complete all as specified and directed by Engineer in charge.
S & F lamp holder PVC Polycarbonate type body, with back plate for batten fitting icluding 9 watt led lamp complete all as specified and as directed by Engineer in charge.
S & F in repair Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets complete all as specified and as directed.Make : Philips Cat part BN 021 LED 22S 6500/4000 PSU GR SI or equivalent
S & F in repair Bulk head endura LED light fitting complete with 10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suitable size & length complete all as specified & directed. Make : Havells Cat Part No. RUGBY NEONFT10WLED760SSYMBOP/ BIBWP10W LED OF bAJAJ Equivalent SURYA SLEBLH 10 / Philips / Crompton
Supply & fix in replacement of LED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed.Make: Surya cat part no :Lexon SLE UL 25W IP66 or HAVELLS Cat part no LHDAUU7PA7J025 VLUMINA or Equ in philips,luker.
S & F in repair Sheet metal enclosure DBs Single Pole and Neutral 8 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge Make- Legrand cat part No.- 5076 21 L&T, ABB.
S & F in repair MCB TPN 415 volts 63 Amps, C Series complete all as specified and directed by Engineer in charge.Make- Legrand , L&T, ABB.
Supply and fixing in replacement MCB single pole and neutral 240 volts 40 Amps, C Series complete all as specified and directed by Engineer in charge.Make- Legrand , L&T , ABB.
Supply and fixing in replacement MCB single pole 240 volts upto 40 Amps, C Series complete all as specified and directed by Engineer in charge. Make- Legrand,L&T,ABB.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. -1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply , laying and testsilng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cab les ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 3.5 core 35 Sqmm complete all as specified and directed by Engineer in charge
S&F GI Tubes,of size 40 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Supply and fixing in replacement of decorative wall light fitting WITH LAMPS 9 WATT made up of Polycarbonate , City-1 , Cylindrical shape , with LED lamp 9 Watt complete with fixing arrangements on wall all as specified and directed. Make: - Surya/ Havells/ Bajaj
Supply & Fixing of Indoor commercial recessed mounted luminaires energy efficient LED luminaire suitable for 600mm x 600mm for grid ceiling light not less than 36 watt with diffusers channel incluidng all accessories, internally pre-wired & making connection to ceiling rose with copper conductor of suitable size & length complete all as specified & directed. Make : Surya cat no sle fp 36 r22 or Wipro Cat Part No. CRCO10R036HP57G1 or Equivalent make & model in Philips or crompton or Havells
S & F in repair of LED Decorative /mirror light fitting 9 watt along with fixture Surface mounted suitable for indoor aplication , connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge. Make- Surya Catpart No Visco SLEBT 10W or equivalent in PHILIPS ,Havells
S&F in replacement of sheet steel enclouser distribution boards, double door factory made Vertical TPN 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB 100 amps and MCB TPN 63 A -02 Nos,MCB SP -04 Nos circuits comprising of 3 phase 4 wire of suitable rating all as specified and directed.Make:Legrand CAT NO 507725 / SIEMENS CAT NO 8GB32203RC04 / GE
S & F in repair Sheet metal enclosure DBs Tripple Pole and Neutral 4 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge Make : Legrand,CAT NO 507895/SIEMENS/GE
S & F in repair Sheet metal enclosure DBs Single Pole and Neutral 12 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge Make : Legrand CAT NO 5076 22/ SIEMENS /GE
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.Make: Legrand cat part no Ekinox metra plug 5078 11 or havells/ anchor
Supply & fixing electronic energy meter tamper proof design digital technology of three phase 3 x 240 volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current for CT operated meter with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp / 5 Amp CT operated with CT with optical communication port complete with all accessories complete with fixing accessories on finished metal box with locking arrangement complete all as specified & directed at site. Make :- SARAL OF SECURE / L&T OR equivalent
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
M&L for Demolition of road/path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) .complete all as specified and as directed.
M&L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M&L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
Supply and laying Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
S&F in repairs on load changer over switch 4 pole, 160 Amp rating, 415 Volts, with steel enclosure and front handle type including connection lugs and testing complete all as specified and directed.
Rai Construction Co
upadhyay Builders
MAYANK CONSTRUCTIONS
ELITE ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .