Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
12 Nov 2021, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Augmentation of substation with Erection of LT line
2021_PDD_142114_1
ED/UDH/32 of 2021-22 dt. 30-09-2021
Open Tender
Electrical Works
Turn-key
90 days
Block Parli Dhar, Ramnagar in Udhampur District
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer, Electric Division JPDCL
₹43,000
3 Dec 2021
1 Oct 2021
15 Nov 2021
1 Oct 2021
12 Nov 2021
1 Oct 2021
1 Oct 2021 - 8 Oct 2021
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning of Augmentation (25 KVA to 63 KVA) Substation at Parli Dhar/ Nalda Pyt. Bland Nalda in Block Parli Dhar
11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
120 mm² Single-Core Cable, 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type including providing and fixing of thimbles
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
LT Distribution box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuits.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Galvanised Stay Set with 50x8mm Stay clamp, Guy Insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia. GI stranded wire complete
Painting of Substation ST poles/cross arms/clamps with one coat of Red oxide and two coats of Aluminium paint
Danger Plates with Clamps
Dismantling of Old Transformer with allied materials & Transportation from site to Divisional Store Udhampur
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning of Augmentation (25 KVA to 63 KVA) Substation at Pyt. Sunter-B/Touri in Block Ramnagar
11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
120 mm² Single-Core Cable, 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type including providing and fixing of thimbles
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
LT Distribution box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuits.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Galvanised Stay Set with 50x8mm Stay clamp, Guy Insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia. GI stranded wire complete
Painting of Substation ST poles/cross arms/clamps with one coat of Red oxide and two coats of Aluminium paint
Danger Plates with Clamps
Dismantling of Old Transformer with allied materials & Transportation from site to Divisional Store Udhampur
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line on 8 mtr long ST poles for Restoration of power in Ramnagar DDC Constituency -I
8 mtr. Long ST Pole( ST-410 SP15)
GI Mukki Clamps
0.03 ACSR Conductor Weasel
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates
Anti- Climbing Device with Clamps
Earthing complete by GI rod 20 mm, 2.5 mtr long through G.I. Strip 32mmx3mm
Painting of ST Poles 8 mtr including cross arm, clamps with one coat of Red Oxide
Painting of ST Poles 8 mtr including cross arm, clamps with 2 coats of Aluminium Paint
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning of LT line on 8 mtr long PCC Poles in different Panchayat of DDC Ramanagar-II
8 mtr. Long PCC Pole (PCC WL-200 Kg)
G.I. U-Clamps
0.02 ACSR Conductor Squirrel
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates
Anti- Climbing Device with Clamps
Earthing complete by GI rod 20 mm, 2.5 mtr long through G.I. Strip 32mmx3mm
Stone Pad (300 mm X 300 mm X 75mm)
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, Guy Insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning of LT line/repair in different Panchayat of Block Ramnagar DDC-II
8 mtr. Long ST Pole( ST-410 SP15)
GI Mukki Clamps
0.03 ACSR Conductor Weasel
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates
Anti- Climbing Device with Clamps
Earthing complete by GI rod 20 mm, 2.5 mtr long through G.I. Strip 32mmx3mm
Painting of ST Poles 8 mtr including cross arm, clamps with one coat of Red Oxide
Painting of ST Poles 8 mtr including cross arm, clamps with 2 coats of Aluminium Paint
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning of LT line on 8 mtr. PCC poles in different Panchayat in DDC-II Ramnagar.
8 mtr. Long PCC Pole (PCC WL-200 Kg)
G.I. U-Clamps
0.02 ACSR Conductor Squirrel
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates
Anti- Climbing Device with Clamps
Earthing complete by GI rod 20 mm, 2.5 mtr long through G.I. Strip 32mmx3mm
Stone Pad (300 mm X 300 mm X 75mm)
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, Guy Insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
vijay builders
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .