Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.9 L+₹2.5 L (23.9%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
4 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KHUMBATHANG
GE KHUMBATHANG
REPAIR REPLACEMENT OF ELECTRIC POLES,ACSR CONDUCTORS AND OTHER EXTERNAL ELECTRIFICATION ALLIED WKS AT HANUTHANG,ACHINATHANG,BATALIK BIAMAH IN THE THE AOR OF AGE B R-II KHALTSI UNDER GE KHUMBATHANG
2023_MES_600717_1
GE/KHU- 25/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE KHUMBATHANG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE KHUMBATHANG
₹30,000
27 Jul 2023
3 Jun 2023
5 Jul 2023
3 Jun 2023
4 Jul 2023
16 Jun 2023
Amount
Supply and fix in repair of cable straight through jointing kit for 11 KV grade (Earthed) cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair cable end jointing kit for 11 KV grade (Earthed) cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm. complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair cable end jointing kit for 11 KV grade (Earthed) cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm. complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair cable end jointing kit for 11 KV grade (Earthed) cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm. complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Eng-in-Charge.
S&F Aluminium conductor of any size with steel reinforced all as specified and directed by Engr-in-Charge.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of alumn paint. complete all as specified and directed by Eng-in-Charge.
S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Eng-in-Charge.
Material and labour for GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately ) complete all as specified and directed by Eng-in-Charge.
All as per srl item No 10 but 40mm bore
Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable complete all as specified & directed by Engr-in-charge.
S&F Top gasket made of 3mm thick cork sheet with suitable holes for 11/0.433 KV transformer of any type/capacity including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity/size transformercomplete all as specified and directed by Eng-in-Charge. .Capicity-(i) 250KVA-04 Nos (ii) 500 KVA-04 Nos
Disconnecting electrically, open the cover of transformer any type/size and filtration and dehydration of Transformer oil for 11 / 0.433 KV transformers, with stream line mobile filtration plant (To be provided by contractor & quoted prices deemed to include its hire charges) at a temp from 60-75 degree celsius to achieve the dielectric strength of oil 60 KV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove the moisture from winding and core complete all as specified and directed by Eng-in-Charge. Note : (a) Filtration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. (b) Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescribed manner.
M&L for Open the cover of transformer any type/size on site and filling in with new transformer oil low viscosity of approved make as per IS-335 of 1992 including heating of oil and die-electric strength 70 KV when tested at 4mm gap complete all as specified and directed by Eng-in-Charge.
M & L for marking/writing feeder names/ SM No / MES No for HT/LT Electrical Eqpts like VCB, Tfrs, LBS / RMU/panels etc with synthetic enamel paint Or Stickers equivalent of approved color complete all as specified and directed by Eng-in-Charge.
Servicing of switch air break gang operated device (GOD) 200 amps, 11 KV, by cleaning moving / fix contact jaw ,MS jumper / MS jumper carrier including replacement of ACSR Jumpers with PG clamps, nut bolts etc and providing white petroleum jelly and making all connection tightened and aluminium lugs etc complete and testing on full operating etc complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair switch air break gang operated device (GOD) 200 amps, 11 KV ,MS jumper / MS jumper carrier including replacement of ACSR Jumpers with PG clamps, nut bolts etc and providing white petroleum jelly and making all connection tightened and aluminium lugs etc complete and testing on full operating etc complete all as specified and directed by Eng-in-Charge.
M&L in repair pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two GI washers and one GI nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Eng-in-Charge.
M&L in repair for shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts of size 75mm height and 90mm dia size of strap 31x3mm and dia of bolts 12mm for working pressure 1100 volts grade complete all as specified and directed by Eng-in-Charge.
M&L in repair for loop type insulator, vitreous porcelain white, brown or green large size with overall dimensions 90mmx140mm clearance of hole 25.5mm complete all as specified and directed by Eng-in-Charge.
M&L in replacement of changeover switch 400 amp 415 volts four pole with sheet metal enclosure complete all as specified and directed by Eng-in-Charge.
M&L in replacement of changeover switch 200 amp 415 volts four pole with sheet metal enclosure complete all as specified and directed by Eng-in-Charge.
M&L in replacement of changeover switch 100 amp 415 volts four pole with sheet metal enclosure complete all as specified and directed by Eng-in-Charge.
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size16 Sq mm 4 core complete all as specified and directed by Eng-in-Charge.
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 25 Sq mm 4 core complete all as specified and directed by Eng-in-Charge.
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 35 Sq mm 3.5 core complete all as specified and directed by Eng-in-Charge.
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 50 Sq mm 3.5 core complete all as specified and directed by Eng-in-Charge.
Excavation in trenches, getting out in hard/dense soil not exceeding 1.5m deep and not exc 1.5m wide for taking out the existing cable of poles etc any size at places complete all as specified and directed by Eng-in-Charge.
Removing of surplus soil to a distance not exceeding 50 mtr complete all as specified and deposited where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Eng-in-Charge.
Returning filing in including spreading levelling, watering & well ramming in layers not exceeding 25 Cm thick complete all as specified and directed by Eng-in-Charge.
Material & Labour for sand cushioning 15 cm below and 8 cm above the U/G cable laid (total depth of sand shall be 18 cm) complete all as specified & directed by Engr-in-Charge.
M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other complete all as specified and directed by Eng-in-Charge.
Supply and erection truely vertical position steel tubular swaged pole complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 mtr long) including painting with two coats of aluminium paint over one coat of red oxide primer, with black and white strips 30 cm each starting with black strip upto 1.5 mtr complete all as specified and directed by Eng-in-Charge.
M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in pole/stay/ plinth etc in foundation filling complete all as specified and directed by Eng-in-Charge.
M&L for cement concrete type C2 1:3:6 (40mm graded aggregate) in copping of poles all as directed by Engr-in-Charge.
Deduct Credit for Demolished/Dismantled material Rs (-) 24322.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
M/S TRADE LINK
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .