Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.2 LAccepted-AOC RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L-1 | Accepted-AOC Lowest bid | |
| 2 | L-2₹15.3 L+₹13,620 (0.90%)Rejected-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L-2 | Rejected-Finance Not being a lowest tenderer | |
| 3 | L-3₹15.4 L+₹18,747.50 (1.23%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L-3 | Rejected-Finance Not being a lowest tenderer | |
| 4 | L-4₹15.7 L+₹54,235 (3.57%)Rejected-Finance B 12 BASEMENT PLOT NO 19 RETAIL BUSINESS CENTRE ADITYA COMPLEX NANGAL RAYA SOUTH WEST NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L-4 | Rejected-Finance Not being a lowest tenderer | |
| 5 | L-5₹15.8 L+₹62,410 (4.10%)Rejected-Finance | L-5 | Rejected-Finance Not being a lowest tenderer |
Tender Value
₹20.0 L
EMD Value
₹40,100
Closing Date
22 Apr 2024, 6:00 pmClosed
HQ CWE (U) DELHI CANTT-10
HQ CWE (U) DELHI CANTT-10
PROVN OF STORAGE SHED FROM PROJECT CONTINGENCY AT DELHI CANTT-10
2024_MES_648480_1
CWE(U)/D-38/2023-24
Open Tender
Civil Works
Item Rate
120 days
HQ CWE (U) DELHI CANTT-10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) (U) B/R DELHI CANTT-10
₹40,100
Yes
1 Jun 2024
30 Mar 2024
30 Apr 2024
30 Mar 2024
22 Apr 2024
17 Apr 2024
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m depth in hard and dense soil for foundation etc or for shaft, wells, man holes, pier holes etc n exc 10 Sqm on plan and not exc 1.5m depth and getting out complete all as specified and directed.
Returning filling in including spreading leveling and well ramming in layers not exc 25 cm in hard soil.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above starting point.
M&L PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in mass. concrete, foundation filling etc complete all as specified and directed.
M&L mild steel TMT reinforcement bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by the Engr-in- Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M&L for M-25 Design Mix Concrete using 20mm nominal size of aggregate as in Foundations, including rafts, footings, foundation beams; plinth bean bases for columns, etc.; basement slabs, under-reamed piles and similar work and mass concrete etc all as specified and directed
Brickwork with Sub class ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6.
M&L Rendering 15 mm thick cement plaster in CM 1:4 for fair surfaces of brickwork or concrete surfaces wall finished even & smooth without using extra cement.
M&L preparation of newly plastered walls, pilasters, cornices surface etc& applying two coats of cement base paint over a coat of self primer all as specified and as directed.
M&L Mild steel Plates 10 mm thick plain channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410W Gde E-250 quality as specified and directed.
S&F Mild steel screw bolts 16 to 20mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long but not exc 10 cm long
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tube conforming to IS 1161-1979 grade St-240 complete all as specified and directed
S&F Pre Painted galvalume aluminium zinc coating Gl based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. (Note: The length of self tapping screw may vary for wooden and steel truss. Contractor to quote rate accordingly). (ROOF SHEETS)
M&L Pre Painted galvalume aluminium zinc coating Gl based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in ridges, roof covering/cladding to wall, fixed with self tapping screws as specified. (Note: The length of self tapping screw may vary for wooden and steel truss. Contractor to quote rate accordingly). (RIDGE AND GUTTER).
S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified an directed
M&L for preparation of new steel surface of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for Hard Core broken boulders to gauge n exc 63 mm all as specified complete
M&L PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in sub base of flooring with 100 mm thickness complete all as specified and directed.
M&L 100 mm thick PCC 1:2:4, type B-2 (using 40mm graded stone aggregate) as in floor finish even and smooth with using extra cement.
M&L75mm thick PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in Plinth Protection laid in alternate panels finishing surface even and smooth without using extra cement.
M&L for Fe 410-W (GdeE-250) quality A rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
M&L for Fe 410-W (GdeE-250) quality A framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for Glass dividing strips, 3 mm thick (Floors) and 38 mm wide laid in joints of PCC floor
M & L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multi stranded, copper conductor Cable, FRLS, 1100 Volt grade, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, drawn through and including concealed, rigid non-metallic PVC Conduit of minimum 20 mm dia or higher as per site requirement with all fittings such as GI metal flush box suitable for modular switches / sockets / fan regulators with cover plates, blanking plates, brass / cadmium plated screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :-
One light/fan/bell/exhaust fan point controlled by one switch.
One 3 Pin socket outlet 5 Amps on Independent board.
One 3 Pin socket outlet 5 Amps on same board.
All as per srl item No. 26 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.
S & F Modular Switch 1 way 6/10 A, 1 Module.
S & F Modular Switch 1 way 16 A, 1 Module.
S & F Modular Socket 6/10 A-2/3 Pin combined 2 module.
S & F Modular Socket 6/16 A - 2/3 Pin combined 2 module.
S & F of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed.
Supply, fixing and connecting wall/ceiling surface type Slim LED Batten not less than 18/20 watt with Surface/Wall Mounted integrated LED 4 feet Fitting Aluminium housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV. Total system Lumen efficiency 120 Lm/watt not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours @ L70B50, IP20, UGR<19 THD <10% complete with all accessories as required complete all as specified and as directed.
Supply, laying and Testing LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-1- 1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing complete all as specified of sectional area: -
10 sq mm x 2 core
S & F sub main wiring with 2 runs of 2.5 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, cable FRLS drawn through and including 20 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 2.5 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note: Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length.
S & F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.
S & F MCB, SP, 6 to 32 Amps capacity, 240V, C Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed
S & F RCCBs, SPN, 40 Amps capacity, overline 240V 30 mA with earth leakage protection complete all as specified and directed.
M&L Earthing with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5 m below normal ground level connected to galvanized earth lead to Gl strip 32 x 6 mm, by means of bolts, nuts, check nuts and washers of brass connected all as shown in the electrical plate No 5 of MES Schedule Pt-I 2009, including necessary earth work and PCC 1:2:4 type B2 pit including charcoal & common salt in alternate layers of 150 mm thick, Gi pipe 20 mm dia light grade watering pipe with PGI funnel with wire mesh, cover 40 mm thick in RCC 1:2:4 with 8 mm dia TMT bar @ 75 mm centre to centre both ways, lifting handle 2 Nos of 12 mm dia MS round bar on both sides fixed in MS angle iron frame 40x40x5 mm and Gl strip 32x 6mm from earth plate to test point upto 7.5m including 40mm dia protection pipe, light grade upto 7.5m length including testing point of Phosphorous bronze/gun metal of size 75x75x25 mm and connected to earthing test point including testing on completion complete.
Supply and fixing roof top naturally wind operated turbo air ventilator of outer diameter 28", effective throatal Dia 21 inch overall height 17 inch, wind velocity not less than 1600 exhauster fitted with nylon made typhonic bearing, double top cap ensured permanent alignment in inverted cap design, corrugated foil framed vanes, highly sensitive roller bearing systems, Drives out dust soil grit & forging material, fabricated from aluminium and stainless steel, translucent opel base, impact and trust resistant, light weight, free spinning complete all as specified and directed by Engineer-in-Charge.
SHREE RAM BUILD TECH
R. S. Associates
S D Constructions
M/S R.M. Builders
M/s Vijay Enterprises
B. S BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .