Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAdmitted-Finance 138 UDYOG BHAWAN SONAWALA ROAD GOREGAON EAST MUMBAI 63 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | L1 | Admitted-Finance | |
| 2 | L2₹7.8 Cr+₹40.2 L (5.47%)Admitted-Finance A 602 SARITA GARDEN CHS LTD OPPOSITE SBI BANK VAKOLA PIPELINE SANTACRUZ EAST MUMBAI 400055 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400055 | L2 | Admitted-Finance | |
| 3 | L3₹7.8 Cr+₹42.5 L (5.79%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Ramsangam Projects Pvt Ltd L2 | Comtech Telesolutions Pvt. Ltd. L1 | VENUS EPC PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying, installing, testing and commissioning of Addressable Multisensor/Multicriteria Photo Thermal (Smoke + Heat) Detector. The detector shall have twin bi-colour LED for 360 deg viewing. The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. This item is referred for Non-conditioning Area conforming to EN 54/VdS / UL & FM approved with | 340 | Each | 8,000 ₹27,20,000 | 7,600 ₹25,84,000 Lowest | 8,250 ₹28,05,000 |
| 2.00 | Supply, installation, testing and commissioning of 12 Loop Microprocessor based analogue addressable type Fire Alarm Control Panel and it should be expandaple upto 16 Loops. Each Loop should support min. 254 detectors/devices in any combination and should support minimum distance of loop 1500 mtrs.The Controller shall be with Touch screen color display, Inbuilt Network ports ((both RS485&Ethernet)) & Inbuilt Printer ports. The Panel shall be UL/VDS/EN 54 approved. cost shall be included with required software, license, associated card , cable & hardware as completed. | 4 | Each | 33,75,000 ₹1,35,00,000 | 32,50,000 ₹1,30,00,000 Lowest | 34,40,000 ₹1,37,60,000 |
| 3.00 | Supply, Installation, Testing & Commissioning of Fire Command Station including Graphical User Interface Software. The GUI based main network software shall be capable of graphically representing each node being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’ locations. The GUI software shall be located in control room and shall monitor all the blocks panel connected with each other. The software shall provide the facility to Monitor over Fire Network along with the Fire detection signal. cost shall be included with required software, license, associated card , cable & hardware as completed. | 1 | Each | 9,10,000 ₹9,10,000 | 8,76,000 ₹8,76,000 Lowest | 9,15,000 ₹9,15,000 |
| 4.00 | Supply, Installation, Testing & Commissioning of Bacnet Gateway for Integration with BMS System. The BACNET Gateway shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation (failure of CPU shall not result in failure of BACNET Gateway). cost shall be included with required software, license, associated card , cable & hardware as completed. | 4 | Each | 2,06,000 ₹8,24,000 | 1,98,000 ₹7,92,000 Lowest | 2,07,500 ₹8,30,000 |
| 5.00 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, minimum 10" LCD or LED display with resistive touch screen or function keys and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels or on-board LCD alphanumeric backlit display suitable up to 640 characters with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel shall conforming to IS 15908:2021, IS 2189: 2008, NFPA-72, EN 54 / VdS/FM & UL with 3 years replacement warranty FF?AFAS/RP. (Compatible with modular FAS panel from 4 loop upto 16 Loop Fire Alarm Control Panel)(NON CSR) | 2 | Each | 2,65,000 ₹5,30,000 | 2,54,000 ₹5,08,000 Lowest | 2,67,000 ₹5,34,000 |
| 6.00 | Supplying and erecting 25 mm Ball Valve complete with PN16 pressure rating . | 123 | Each | 1,550 ₹1,90,650 | 1,475 ₹1,81,425 Lowest | 1,600 ₹1,96,800 |
| 7.00 | Providing coating of bitumen paint & pipeline corrosion resistant Pypkote tape conforming to IS 10221 Appendix B specification having 4mm thick wrapping for underground 150 mm ring main of fire fighting system. (Pypkote tape comprises of a Tar based Polymeric mix supported on a fabric of high tensile strength Fibreglass). | 630 | Each | 380 ₹2,39,400 | 364 ₹2,29,320 Lowest | 385 ₹2,42,550 |
| 8.00 | Supply & Erection of Pot Strainer of Ductile CI Body flanged ends of PN16 rating for Condensser water circulation at the Outlet of Cooling towers with stainless steel strainer including High tension Nut bolts with Gasket as specified. 500 mm dia | 1 | Each | 80,000 ₹80,000 | 76,850 ₹76,850 Lowest | 81,500 ₹81,500 |
| 9.00 | Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 300 mm dia | 5 | Each | 59,000 ₹2,95,000 | 56,445 ₹2,82,225 Lowest | 62,500 ₹3,12,500 |
| 10.00 | Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 250 mm dia | 5 | Each | 53,500 ₹2,67,500 | 50,446 ₹2,52,230 Lowest | 55,000 ₹2,75,000 |
Tender Value
Refer Docs
Closing Date
22 Sept 2026, 5:30 pmClosed
Executive Engineer Central Mumbai Electrical Divis
Executive Engineer Central Mumbai Electrical Division Sadhana House 2nd floor, Pandurang Budhkar marg, Behind Mahindra Tower, Worli, Mumbai -18.Telephone 022 4564 6881
SITC of Complete Electrical Installation including all building services with necessary allied building works for proposed 2 Basement G 10 Storey SuperSpeciality Hospital 1200 Bedded at Sir. JJ Group of Hospital, Byculla, Mumbai
2026_PWDM_1338686_1
Quatation/06/01/26-27/1st
Open Tender
Electrical Works
Item Rate
180 days
JJ Hospital subdivision
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
24 Sept 2026
15 Sept 2026
24 Sept 2026
15 Sept 2026
22 Sept 2026
15 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installing, testing and commissioning of Addressable Multisensor/Multicriteria Photo Thermal (Smoke + Heat) Detector. The detector shall have twin bi-colour LED for 360 deg viewing. The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. This item is referred for Non-conditioning Area conforming to EN 54/VdS / UL & FM approved with | 340 | Each | - | - |
| 2 | Supply, installation, testing and commissioning of 12 Loop Microprocessor based analogue addressable type Fire Alarm Control Panel and it should be expandaple upto 16 Loops. Each Loop should support min. 254 detectors/devices in any combination and should support minimum distance of loop 1500 mtrs.The Controller shall be with Touch screen color display, Inbuilt Network ports ((both RS485&Ethernet)) & Inbuilt Printer ports. The Panel shall be UL/VDS/EN 54 approved. cost shall be included with required software, license, associated card , cable & hardware as completed. | 4 | Each | - | - |
| 3 | Supply, Installation, Testing & Commissioning of Fire Command Station including Graphical User Interface Software. The GUI based main network software shall be capable of graphically representing each node being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’ locations. The GUI software shall be located in control room and shall monitor all the blocks panel connected with each other. The software shall provide the facility to Monitor over Fire Network along with the Fire detection signal. cost shall be included with required software, license, associated card , cable & hardware as completed. | 1 | Each | - | - |
| 4 | Supply, Installation, Testing & Commissioning of Bacnet Gateway for Integration with BMS System. The BACNET Gateway shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation (failure of CPU shall not result in failure of BACNET Gateway). cost shall be included with required software, license, associated card , cable & hardware as completed. | 4 | Each | - | - |
| 5 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, minimum 10" LCD or LED display with resistive touch screen or function keys and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels or on-board LCD alphanumeric backlit display suitable up to 640 characters with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel shall conforming to IS 15908:2021, IS 2189: 2008, NFPA-72, EN 54 / VdS/FM & UL with 3 years replacement warranty FFAFAS/RP. (Compatible with modular FAS panel from 4 loop upto 16 Loop Fire Alarm Control Panel)(NON CSR) | 2 | Each | - | - |
| 6 | Supplying and erecting 25 mm Ball Valve complete with PN16 pressure rating . | 123 | Each | - | - |
| 7 | Providing coating of bitumen paint & pipeline corrosion resistant Pypkote tape conforming to IS 10221 Appendix B specification having 4mm thick wrapping for underground 150 mm ring main of fire fighting system. (Pypkote tape comprises of a Tar based Polymeric mix supported on a fabric of high tensile strength Fibreglass). | 630 | Each | - | - |
| 8 | Supply & Erection of Pot Strainer of Ductile CI Body flanged ends of PN16 rating for Condensser water circulation at the Outlet of Cooling towers with stainless steel strainer including High tension Nut bolts with Gasket as specified. 500 mm dia | 1 | Each | - | - |
| 9 | Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 300 mm dia | 5 | Each | - | - |
| 10 | Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 250 mm dia | 5 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_2288895.xls
BOQ • 1.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .