| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹50.5 L+₹1.6 L (3.34%)Rejected-Finance MOHANPUR PT LL HOUSE NO 00 CITY TOWN SILCHAR P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹55.6 L+₹6.7 L (13.6%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹55.7 L+₹6.8 L (13.9%)Rejected-Finance MAHALAKPUR NIZAMPUR AGHWANPUR ROAD AGHWANPUR MORADABAD UTTAR PRADESH 244001 | MORADABAD | UTTAR PRADESH | 244001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹56.3 L+₹7.4 L (15.1%)Rejected-Finance ROOM NO 13 HIMALAYA SHOPPING COMPLEX NELI SENGUPTA SARANI BABU PARA DARJEELING WEST BENGAL 734004 | DARJEELING | WEST BENGAL | 734004 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
30 Jan 2021, 6:00 pmClosed
GE SEVOKE ROAD
GE SEVOKE ROAD POST SALUGARA DIST JALPAIGURI
REPAIR OF SEWAGE PUMP AND OPERATION AND MAINT OF STP AT SEVOKE MIL STN UNDER GE SEVOKE ROAD
2020_MES_408288_1
GE/SEV/63 OF 2020-21
Open Tender
Civil Works
Item Rate
270 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹56,000
Yes
24 Feb 2021
31 Dec 2020
1 Feb 2021
31 Dec 2020
30 Jan 2021
18 Jan 2021
1 Jan 2021 - 9 Jan 2021
Amount
M & L for dismantling defective sewage non clog type sewage pump set upto 10/7.5 HP capacity at site opening suction, delivery pipe line connections,coupling nut bolts and taking out the pump set to contractors workshop for repair, machine work including refixing, assembling coupling with motor,lowering down and testing on full load for 04 hours incl providing gland packing and making the pump leak proof incl any other minor work as required at site and directed by Engineer-in-Charge. Note :-i) Spare parts replaced shall be measured and paid separately as supply only under respective item of schedule ii) Transportation charges for the motor to wksp & back are deemed to be included in rates quoted, no extra payment will be made on this account. iii) Pump set issued for repair must be returned & installed duly repaired within seven days otherwise Rs 100 per day per pump will deducted from the bill as penalty. iv) Minor items like nut/bolts, bearing grease, packing gaskets of required size to be taken in consideration while quoting the rates. No extra payment will be made on this account.
Supply only spare parts for submersible sewage pump set up to 10HP
Impeller sets for one pump
Mechanical seal set
Oil Seal
rubber gasket sealing
M & L for rewinding burnt coils of Induction Motor stator of following capacity with super enamelled copper winding wire as per existing size and guage to achieve the required /specified RPM including taking out old unserviceable winding ,cleaning/ repairing damaged slots , complete all as specified and as directed.
S&F flat submersible cable 3 core multi stranded copper conductor of size 6 sqmm.ISI marked complete all as specified and as directed.
Supply and fix in replacement including lowering of Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & bolts and washers etc for holding column pipes / GI pipes of submersible pump set complete all as directed by Engr-in-Charge.
S & F in repair DOL submerssible pump controller in sheet metal enclosure for 6 HP motor Rating AC-3 Duty, 415V, 50Hz, 3 phase all as specified and directed by Engr-in-Charge
S & F in repair DOL submerssible pump controller in sheet metal enclosure , 10 HP motor Rating AC-3 Duty, 415V, 50Hz, 3 phase all as specified and directed by Engr-in-Charge
M & L for blocking of incoming sewage water in sump,dewatering desilting / taking out accumulated sludge, Silt, Mud etc. from sewage collection sump and connected channels including scrapping down and cleaning internal surface of walls, Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels, pipes Drainage system etc. and removing the same to a distance not exc. 50 Metre and reopening of blockage of sump complete all as specified and as directed. Note:- Quoted rate deemed to included the followings:- (a) Diesel/ electric Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved and directed. (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. (d) Painting of external surface should be cement baised paint
M & L for cleaning of Equalizing tank /grit chamber/ oil grease chamber/stilling chamber of Sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and Painting to Internal and external surfaces of Equalizer tank sewage sump and connected channels with Two Coats of Black Bituminous Paint (Lead Free) including necessary surface preparation by means of scraping, brushing, cleaning all as required at site and directed by the Engineer-in-Charge . Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel/ electric Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. (d) Painting of external surface should be cement baised paint
M & L for cleaning of MBBR-1 and MBBR-2 of Sewage treatment plant and Removing of settle down Sewage sludge cum mud/De-Silting etc as and Painting to Internal and external surfaces of MBBR 1 & 2 and connected channels with Two Coats of Black Bituminous Paint (Lead Free) including necessary surface preparation by means of scraping, brushing, cleaning directed by the Engineer-in-Charge. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel/ electric Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. (d) Painting of external surface should be cement baised paint
M & L for cleaning of Tube settler of Sewage treatment plant and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor 1:3 where required and Painting to Internal and external surfaces of tube settler and connected channels with Two Coats of Black Bituminous Paint (Lead Free) including necessary surface preparation by means of scraping, brushing, cleaning all as required at site and directed by the Engineer-in-Charge for Sewage tank of size as per drawings attached . Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel/ electric Driven Pump Set of appropriate capacity not less than 3 HP with operator including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Canttonment Board/MCD (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. (d) Painting of external surface should be cement baised paint
M & L for cleaning of Treated water tank and chlorine contact tank of STP by removing of all deposited sludge, scale or other unwanted materials from the tank by any means and removing the same away and after cleaning, washing and scraping the wall with Painting to Internal and external surfaces of Treated water tank and chlorine contact tank and connected channels with Two Coats of Black Bituminous Paint (Lead Free) including necessary surface preparation by means of scraping, brushing, cleaning complete all as specified and directed by Engr-in-Charge. (a) Diesel/ electric Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. (d) Painting of external surface should be cement baised paint
M & L for cleaning of sludge holding tank of Sewage treatment plant and Removing of settle down Sewage sludge cum mud/De-Silting etc and Painting to Internal and external surfaces of sludge holding tank of Sewage treatment plant and connected channels with Two Coats of Black Bituminous Paint (Lead Free) including necessary surface preparation by means of scraping, brushing, cleaning directed by the Engineer-in-Charge . Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel/ electric Driven Pump Set of appropriate capacity not less than 3 HP with operator including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge.
Removal of MBBR media from MBBR tank, Tube settler media from tube settler tank, Filter media for DMF and ACF filters complete all as specified and directed by Engineer-in- Charge.
Supply and pouring Bio media made of plastic and corrugated shape having surface area 260 sqm/cum in MBBR as directed by Engr-in-charge. Make: MM Aqua, Bharat, SIMA
Material for replacement of quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge.
Material for replacement of quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge.
Material for replacement of quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge.
Material for replacement of quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge.
Material for replacement of activated carbon IV 1000 complete all as specified and directed by Engr-in-charge.
Material & Labour for painting to exposed Filter media tank (ACF and DMF) at water supply installations as per specified colour code after cleaning and scraping out old paint including writing/marking complete all as specified and directed by Engineer-in-charge
Material & Labour for painting to exposed CI/GI/MS pipe lines of header/suction/delivery of pumps any type/make/size including sluice valves, fittings and non return valves at water supply installations as per specified colour code after cleaning and scraping out old paint including writing/marking complete including removing and refixing the pipes after thoroughly cleaning the pipes all as specified and directed by Engineer-in-charge
S & F as in repairs Dry run protection relay with detection of single phase preventor,VI meter(current based), 3 Phase Motor Starter or as per existing size complete all as specified and as directed.
S&F of 3 phase Digital panel volt Meter Flush Mounting 96x96mm, Accuracy Class-I, input voltage measurement range 17-520V AC (P-P), including taking out unserviceable complete all as specified and as directed.
S&F of 3 phase 5A, Digital panel ammeter Flush Mounting 96x96mm, Accuracy Class-I, CT/PT Site programmable including taking down existing unserviceable one complete all as specified and as directed.
S&F of 3 phase indicator lamp including taking down existing set complete all as specified and as directed by Engr-in-Charge
Supply, laying , jointing, welding & testing MS pipe ( Heavy duty Class 'c') including fitting as required of following sizes laid in treches or laying oe floor for connecting to various STP accessories and to connect outgoing water main including taking down the unserviceable pipe all as directed by Engr-in-charge. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate of this item.
150 mm bore
100 mm bore
80 mm bore
65 mm bore
50 mm bore
40 mm bore
25 mm bore
Material and labour for CI butterfly valve of following sizes, stainless steel disc as per IS 13095 class PN-1.0 complete with nuts, bolts, washer and rubber gasket including taking out old unserviceable butterfly valve complete all as specified and directed by Engr-in-charge.
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
Overhauling of air compressor coupled with blower motor 30 HP capacity Installed at Sewage treatment plant including necessary arrangement to transporting to workshop fro re-grinding of shaft , oiling ,greasing etc and necessary replacement of wornout bolts ,nuts ,washers, silencer, belt drivers, pressure guage, air-filter, bearings, shaft , rings etc . Re-assembling the compressure with blower motor , commissioning and testing to the entire satisfaction of Engineer - in - charge .
Supply only compressure oil all as specified and directed by Engineer - in- charge .
M/L for replacement of Ball bearing of the electric motor upto 15 HP 3 phase / single phase complete all as directed. Make: SKF/TATA/NBC.
M/L for replacement of MS Shaft of the electric motor upto 15 HP 440 Volts in repairs complete all as directed.
Servicing of 3 Phase 415 Volts 1440 RPM Centrifuge Motor coupled with NC Horizontal Multi staging Pumping Set as following: (a) Taking out Motor from its Position by decoupling from Pump and disconnecting all cable connections, Heating & varnishing to stator with super quality varnish Reassembeling the motor, greasing the bearing with bearing grease ,Reinstall the Motor at its existing Position , couple with the Pump connecting all cable connections and testing on completion complete all as specified by Engineer-in- Charge. b). Taking out Pump from its Position by decoupling from Motor and disconnecting , degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts, Replacement of Gasket set and gland packing rope,greasing the bearing with bearing grease ,Reassembeling the Pump complete with all existing serviceable parts, Reinstall the Pump at its existing Position , couple with the Motor and connecting all suction delivery water connections and testing on completion complete all as specified by Engineer-in- Charge.
Surface dressing in hard/dense soil,not exceeding 15cm deep for cleaning the area by cutting the unwanted bushes/vegetation growth in and around the area of installation/around the valve pit chamber/along the pipeline routes if reqd etc all as specified and directed by Engr-in-charge.
M & L for Scraping old paint of Electric Panel and Painting with two coats of synthetic enameal paint over a coat of red oxide primer including disconnecting electric connection and re-wiring without any damage of existing parts as directed by Engnr-in-Charge complete as all specified and as directed.
Supply and placing tube deck media made of plastic and sqaure/ hexagonalshape in tube settler as directed by Engr-in-charge.
M&L for cement concrete 1:3:6 type C-2 (40mm graded stone aggregate) as in foundation and bed complete all as specified and directed.
Testing of sewage water as per relevant IS of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved by GE (a) Carrying out minimum essential testing of sewage water as per relevant IS mandatory for chemical, odour, PH value ,TSS, BOD, COD, total nitrogen, sulphate, oil and grease, ammonical Nitrogen (NH3-N) and Bacteriological total colliform organism and other characterstics as per relevant IS of sewage water:- Note:- Rate quoted shall also deemed to be included for:- (i) Cost of sterilized bottle as required (ii) To and fro Transportation charges for collection of sample
Operation and Maintenance of sewage Treatment plant STP of capacity 1.2 MLD by deploying adequate and experienced qualified skilled operator/staff, round the clock including Sunday and holidays in three shifts per day of 08 hours each ( Ist shift from 0600 to 1400 hours,IInd shift from 1400 to 2200 hours and IIIrd shift from 2200 to 0600 hours) complete inclusive of daily, weekly , monthly, quarterly, Half yearly & Yearly maintenance of equipments. scope of work as described in notes given below complete all as specified and as directed. Quoted rate include the following as mentioned against Ser No 40.01 to 40.08.
Scope of Work comprises:- (i) Stacking the sludge cakes properly (ii) Cleaning the blockages in any pump/pipe line (iii) Supplying/distributing the treated water regularly as per the directions. (iv) Complete cleaning of grits and channels daily. (v) Brooms and cleaning materials will be arranged by the contractor (vi) During the cleaning safety equipments will be supplied/arranged by the contractor.
(vii) Removing the algae/ sludge in the tube settler and keeping the surrounding area clean daily and removing vegetations etc failing which recovery of Rs. 200/- per day shall be made. (ix) Mixing of the chemicals as directed .
Notes :- EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump
Maintaining the following records :- (i) Record of chemical consumption. (ii) Record of treated water and electricity consumption (log sheet)
Notes :- (i) The Plant shall be run by the skilled operator minimum qualification ITI/ matric with minimum three year experience.
(ii) (a) Working hours of a particular team of workers shall not exceed 08 hrs per day and no workmen shall be allowed to work beyond 08 hrs per day. (b) In case the contractor fails to deploy requisite numbers of workmen, the operator / workmen against defficiency shall be deployed at risk and cost of the contractor through SPOT QUOTATION and no payment shall be made to the contractor for the shift involved. (c) In addition to above a recovery of Rs. 500 per shift per workman shall be made from contractor's dues as and when becomes due. (d) Duty roster of manpower deployed shall be displayed otherwise recovery of Rs 500/- per installation per day shall be made.
(iii) All the provisions of contract labour Act 1970 shall be strictly adhered to. (iv) For payment of minimum wages to the workers provisions of particular specifications shall be strictly adhered to. (v) Log sheet for records shall be supplied by the contractor after approval of format by GE/Engineer-in-charge.
(vi) Contractor shall ensure that treated sewage water shall confirm to the following characteristics:- (i) TSS : < 10 mg/litre (ii) BOD : < 10 mg/litre (iii) COD : < 150 Mg/litre (iv) ph : 6.5 - 8.5 (v) Total Coliform : < 100 MPN/100 ml (desired nil) (vi) Residual CI < 1 mg/litre
Supply and mixing of Sodium hypochloride having 10% chlorine content.
Supply and mixing of Dewatering Poly Electrolite 100 % Purity.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of UG cable/pipe in soft loose soil complete.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for providing sand cushioning for protection of UG cable in trenches with dry (coarse) sand approved quality including filling, spreading and punning down to desired thickness complete.
Supply and laying burnt clay sub class B brick as cable protection all as specified and directed.
Supply and fixing GI pipe 50 mm medium grade for UG cable protection with all fitting fixed to pole or laid in trenches or laid in floor/rood all as directed.
Supply and fixing GI pipe 40 mm medium grade for UG cable protection with all fitting fixed to pole or laid in trenches or laid in floor/rood all as directed.
M & L for laying LT underground Cable, including takingdown existing u/s XLPE insulated, heavy duty armoured sheathed 1100 volts grade 10 Sq mm, 2 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete incl making necessery cable end connection with lux/tape all as specified and as directed.
All as per item No 50 above but 16sqmm, 4 core all as specified.
All as per item No 50 above but 25sqmm, 3.5 core all as specified.
All as per item No 50 above but 35sqmm, 3.5 core all as specified.
All as per item No 50 above but 70sqmm, 3.5 core all as specified.
All as per item No 50 above but 95sqmm, 3.5 core all as specified.
All as per item No 50 above but 120sqmm, 3.5 core all as specified.
All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by font size not less than 20 mm letters using Acrylic sheet . The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by font size not less than 20 mm letters using Acrylic sheet . The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by font size not less than 20 mm letters using Acrylic sheet . The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
M&L for boring holes 2mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
Supply and fixing thermoplastic cable junstion box with terminals having protection IP 66/67 "weather proof" for outside installation with metric knockout entry for cable of size 16 sqmm 4 core and size 155x210x92mm with terminals and provision of one MCB SP 6A complete with all pole brackets and fixing arrangements all as specified and as directed of Make Hensel DK1616G or equvilent.
Supply and fixing thermoplastic cable junstion box with terminals having protection IP 66/67 "weather proof" for outside installation with metric knockout entry for cable of size 25sqmm sqmm 3.5 core and size 155x210x92mm with terminals and provision of one MCB SP 6A complete with all pole brackets and fixing arrangements all as specified and as directed of Make Hensel DK2525G or equvilent.
M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings with MCB SP in junction box, complete all as specified and directed.
S&F in repair 3 phase street light panel made of CRCA sheet IP54 with digital 24hrs timer, 65A triple pole contactor, 63A MCB triple pole and necessery complete wiring with max load 12KW of frame size 2 incl all connection and fixing arrangements on wall/floor/pole mounted of make Havells cat part no: IHXTS09120 Engr in charge.
M&L for cement concrete in foundation, filling mass concrete type-C2, 1:3:6, (40mm graded aggregate) all as specified and directed.
M&L in repair for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete.
M/S BHARAT CONSTRUCTION
SRI SURAJIT SENGUPTA
M S BHARAT CONSTRUCTION CO.
Manish Ray and Co.
M/s. STRUCTURES INDIA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .