Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹38.7 L+₹5.0 L (14.9%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹39.0 L+₹5.3 L (15.9%)Rejected-Finance 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹39.3 L+₹5.7 L (16.8%)Rejected-Finance 3 3430 NICHOLSON ROAD KASHMERE GATE DELHI DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹40.4 L+₹6.7 L (19.8%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | SWAMI ENGINEERS L1 | Arneja Builders L5 | FAVOURITE ENGINEERS L8 | m/s panchmukhi builders L7 | DELTA CONSTRUCTION CO L6 | Buttar Construction Co. L3 | Jawandha Enterprises L2 | ANIL KUMAR AND CO L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed | 410 | Sqm | 10 ₹4,100 Lowest | 10 ₹4,100 Lowest | 10 ₹4,100 Lowest | 10 ₹4,100 Lowest | 15 ₹6,150 | 15 ₹6,150 | 15 ₹6,150 | 10 ₹4,100 Lowest |
| 2.00 | Material & labour for Non - skid coloured Ceramic tiles 10mm thick (square/ rectangular) area of Each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over and incl 15 mm thick cement mortar (1:4) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-Charge. | 100 | Sqm | 700 ₹70,000 Lowest | 700 ₹70,000 Lowest | 750 ₹75,000 | 735 ₹73,500 | 750 ₹75,000 | 700 ₹70,000 Lowest | 700 ₹70,000 Lowest | 700 ₹70,000 Lowest |
| 3.00 | Material & labour for Glazed ceramic coloured printed/digital tiles 7 to 8 mm thick area of Each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, on vertical surface such as skirting , dado etc. over and including 10 mm thick rendering in cement mortar 1:4 thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles complete all as specified and directed by Engineer-in-Charge. | 110 | Sqm | 700 ₹77,000 Lowest | 725 ₹79,750 | 750 ₹82,500 | 780 ₹85,800 | 780 ₹85,800 | 780 ₹85,800 | 750 ₹82,500 | 700 ₹77,000 Lowest |
| 4.00 | Material & labour for non skid Ceramic tiles(light shade) 10 mm thick (square/ rectangular) polished, size of each 600mm X 600mm, in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match, joined in cement slurry over and incl 15mm thick cement mortar (1:6) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-charge. | 200 | SQUARE METRE | 700 ₹1,40,000 Lowest | 800 ₹1,60,000 | 950 ₹1,90,000 | 880 ₹1,76,000 | 800 ₹1,60,000 | 800 ₹1,60,000 | 750 ₹1,50,000 | 750 ₹1,50,000 |
| 5.00 | Demolition of cement concrete un -reinforced in ground floors and pavings complete all as specified and directed. | 8 | Cum | 50 ₹400 Lowest | 200 ₹1,600 | 200 ₹1,600 | 100 ₹800 | 100 ₹800 | 50 ₹400 Lowest | 350 ₹2,800 | 50 ₹400 Lowest |
| 6.00 | Material & labour for machine cut Kota stone slab flooring 23-25 mm thick laid over 15 mm thick cement mortar 1:4screed bed laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing to mirror finish complete to be fixed in any position as described and specified. | 200 | Sqm | 700 ₹1,40,000 Lowest | 1,100 ₹2,20,000 | 1,100 ₹2,20,000 | 900 ₹1,80,000 | 1,050 ₹2,10,000 | 1,100 ₹2,20,000 | 900 ₹1,80,000 | 1,000 ₹2,00,000 |
| 7.00 | Material & labour for Baroda green Marble work 18 to 20mm thick (table rubbed and polished) in steps, windowcills, laid over 15 mm in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including rubbing and polishing to mirror finish complete to be fixed in any position as described and specified. | 80 | Sqm | 1,500 ₹1,20,000 | 1,600 ₹1,28,000 | 1,500 ₹1,20,000 | 1,800 ₹1,44,000 | 1,650 ₹1,32,000 | 1,600 ₹1,28,000 | 1,450 ₹1,16,000 Lowest | 1,500 ₹1,20,000 |
| 8.00 | Material & labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and directed by Engineer in charge. | 50 | RM | 60 ₹3,000 | 120 ₹6,000 | 100 ₹5,000 | 90 ₹4,500 | 100 ₹5,000 | 100 ₹5,000 | 150 ₹7,500 | 50 ₹2,500 Lowest |
| 9.00 | Material & labour 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granitecomplete all as specified and directed by Engineer-in-Charge. | 30 | Sqm | 2,200 ₹66,000 Lowest | 2,400 ₹72,000 | 2,500 ₹75,000 | 2,800 ₹84,000 | 2,200 ₹66,000 Lowest | 2,800 ₹84,000 | 2,250 ₹67,500 | 2,500 ₹75,000 |
| 10.00 | Demolition of cement concrete un -reinforced in ground floors and pavings complete all as specified and directed. | 5 | CUBIC METER | 50 ₹250 Lowest | 100 ₹500 | 200 ₹1,000 | 120 ₹600 | 250 ₹1,250 | 100 ₹500 | 500 ₹2,500 | 50 ₹250 Lowest |
Tender Value
Refer Docs
EMD Value
₹77,560
Closing Date
16 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ MOHAMMED AQIL AZEEM
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
SPL REPAIR TO BLDG NO P-17 OF 1 ADSR AT PATIALA MIL STN
2025_MES_722831_1
GE (N)/TOKEN-43/2025-2026
Open Tender
Civil Works
Item Rate
180 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE N PATIALA
₹77,560
Yes
20 Sept 2025
26 Jul 2025
18 Aug 2025
26 Jul 2025
16 Aug 2025
9 Aug 2025
Amount
Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed
Material & labour for Non - skid coloured Ceramic tiles 10mm thick (square/ rectangular) area of Each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over and incl 15 mm thick cement mortar (1:4) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-Charge.
Material & labour for Glazed ceramic coloured printed/digital tiles 7 to 8 mm thick area of Each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, on vertical surface such as skirting , dado etc. over and including 10 mm thick rendering in cement mortar 1:4 thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles complete all as specified and directed by Engineer-in-Charge.
Material & labour for non skid Ceramic tiles(light shade) 10 mm thick (square/ rectangular) polished, size of each 600mm X 600mm, in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match, joined in cement slurry over and incl 15mm thick cement mortar (1:6) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete un -reinforced in ground floors and pavings complete all as specified and directed.
Material & labour for machine cut Kota stone slab flooring 23-25 mm thick laid over 15 mm thick cement mortar 1:4screed bed laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing to mirror finish complete to be fixed in any position as described and specified.
Material & labour for Baroda green Marble work 18 to 20mm thick (table rubbed and polished) in steps, windowcills, laid over 15 mm in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including rubbing and polishing to mirror finish complete to be fixed in any position as described and specified.
Material & labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and directed by Engineer in charge.
Material & labour 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granitecomplete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete un -reinforced in ground floors and pavings complete all as specified and directed.
Material and labour for Plain cement concrete 1:7:12 mix, (using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed.
Material and labour for carrying out water proofing treatment of sunken floor complete all as specified under:(i) The concrete/wall surface shall be cleaned thoroughly of all laitance,loose particles,dust,grease etc and any friable and unsound area which shall be chipped,cleaned and thereafter pre-wetted to a satured surface dried condition. (ii) In case of pot holes/superficial cracks,the same shall be repaired with polymer modified mortar using URP as admixture @ 10% of cement content. (iii) The polymer modified mortar using URP as admixture @10% of cement content shall also be applied on vertical surfaces after removing of plaster upto 60 cm height.(iv) The surface thus prepared shall be coated by applying 2 coats of Dr Fixit Hydrochem super in the sunken areas and extending it upto 150 mm above the finished floor level.This includes layer of a 150 mm wide strip of an open woven glass fiber mesh over the PCC benching (Gole) whille it is still wet.(v) Rendering 15 mm in CM 1:4 admixed with integral water proofing compound 1 W+ @ 200 ml per bag of cement complete all as specified and directed by the Engineer-in-Charge.
Providing 50 mm dia GI pipe light grade spouts complete all as specified and directed.
Material & labour for PCC with type B-0. 1:2:4 (20mm graded aggregate) 40 mm thick as in flooring and finishing the floor even and smooth without using extra cement complete all as specified and directed
Supply & fixed in repair vitreous china premium/1st quality wash basin white/ivory/off white, flat back, size 550x400 mm including pedestal, screws & plug and brackets etc. all accessories as recommended by manufacturer incl inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union and incl 32mm brass CP waste coupling and waste pipe complete in all respect as per manufacturer's instructions complete all as specified and directed
Supply & fixed in repair vitreous china premium/1st quality wash down water closet pan floor mounting (pedestal pattern/EWC) S/P trap white/ivory including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe CP 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm S/P trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors except G.F.complete all as specified and directed
Supply & fixed in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long CP flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
Supply & fixed in repair flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.
Supply & fixed in repair of Cast iron spun pipes 100mm bore pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
Supply & fixed in repair of Cast iron soil, waste and vent pipe, Centrifugal type 100mm bore, spun cast in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps (25x3 mm), nuts , bolts etc. and making necessary connections complete all as specified.
Supply & fixed in repair of Cast iron spun pipes 75mm bore pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
Supply & fixed in repair of Cast iron soil, waste and vent pipe, Centrifugal type 75mm bore, spun cast in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps(25x3mm), nuts , bolts etc. and making necessary connections complete all as specified.
Supply & fixing for cast iron branch pieces single Centrifugal type (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 100 mm bore pipe, fitted with oval access door jointed with cement joint, complete all as specified.
Supply & fixing for cast iron branch pieces single Centrifugal type (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 75 mm bore pipe, fitted with oval access door jointed with cement joint, complete all as specified.
Supply & fixing for CI Cowl Centrifugal type suitable for 100 mm bore pipe as in repair, complete all as specified.
Supply & fixing for Cast iron bends/Tee duck foot or heel rest, radius for 75 mm bore pipe, complete all as specified and directed.
Supply & fixing for Cast iron bends/Tee duck foot or heel rest, radius for 100 mm bore pipe, complete all as specified and directed.
Supply & fixing Salt-glazed stoneware gully traps,Centrifugal type 150x150mm size, square or round mouthed, type 'P' or 'S' incl CI grating fixed in repair complete all as directed and specified.
Supply & fixing Cast iron floor trap 100 mm dia and 600 mm long including jointing with solvent cement in repair complete all as specified and directed by Engineer-in-Charge.
Supply & fixing doubled layered rotational moulded polyethylene white water storage tanks (cylindrical vertical with closed top / cover) 1000 Ltrs capacity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC tank complete all as specified and directed.
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixingor removal to store.
Supply and fixing 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and celing or laid in floor etc complete all as specified.
Supply and fixing 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and celing or laid in floor etc complete all as specified.
Supply and fixing 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply & fixed in repair Bib taps, CP, fency type long body with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete in all respect all as specified.
Supply & fixed in repair 15 mm dia Stop cock cast copper alloy fancy type CP with long shank and cup (concealed type), screw down high pressure, screwed both ends for iron pipe or for union and fixed complete all as specified and directed
Supply & fixed in repair Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed
Supply & fixed in repair Angular Stop Cock with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete in all respect all as specified.
Supply & fixed in repair PVC connections 15mm size with PTMT nuts of length 450mm. complete in all respect all as specified.
Supply & fixed in repair Chromium plated shower roses with or without swivel joints, any for 15mm pipes, including fixing to steel pipe or union. complete in all respect all as specified.
Supply & fixed in repair Pillar taps, fency type, long neck, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe complete all as specified and directed
Supply & fixed in repair acrylic glass shelf assembly for soap dish and appropriate space for placing other things like tooth brushes comb tooth paste etc and fiexed to walls with plug and brass chromium plated screws complete all as specified and directed.
Material & labour Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar , including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed by engineer in charge
Material & labour Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius in cement mortar (1:6), complete all as specified and directed by engineer in charge
Material & labour Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in with cement mortar(1:4), complete all as specified and directed by engineer in charge
Material & labour for raking out joints, flush pointing in cement mortar 1:3, to bricks laid flat or brick tiles in pavings, aprons etc, complete all as specified and directed
Supply & fixing for PVC(HDPE) rain water pipes, 150 mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc including taking down existing damaged CI rain water pipe complete all as specified and as directed
Supply & fixing PVC (SWR) bends/tees of any radius for 150mm bore as in repair complete all as specified.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm complete all as specified.
Supply & fixing factory made Mild Steel Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,size 105x60mm including filling of PCC 1:3:6, using 12.50 mm graded aggregate in chowkhats and PCC 1:2:4 B1 as in hold fasts blocks including necessary form work complete as specified.
Supply & fixing factory made Mild Steel Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,size 125x60mm including filling of PCC 1:3:6, using 12.50 mm graded aggregate in chowkhats and PCC 1:2:4 B1 as in hold fasts blocks including necessary form work complete as specified,
Material & labour factory made flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Material & labour 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass,gauze etc (without sash bars) edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Pt-I section 8 clause 8.24(a) supplied and fitted to chowkhats complete all as specified and directed.
Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 complete all as specified and directed.
Material & labour PCC (1:2:4 ) type B1 using 12.50 mm graded aggregate as infilling in PS Chowkhats/Holdfast Block all as specified .
Supply & fixing Butt hinges 100 mm size,medium weight stainless steel complete all as specified and directed.
Supply & fixing Aluminium alloy, anodised, sliding door bolt 250 mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Supply & fixing Aluminium anodised, barrel tower bolts of 200 mm size of extruded section and fixed complete all as specified and directed.
Supply & fixing Floor door stopper of size 140 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed in floor complete all as specified and directed.
Supply & fixing powder coated aluminium handles 125mm complete all as specified and directed.
Supply & fixing stainless Harrison rails, mild steel, chromium plated 25 mm dia with fixing brackets, stops, rollers , finials etc for curtain rod incl all fixing complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate including necessary welding to chowklhats complete fixed all as specified.
Taking down chokhats or frames (without taking off shutters from the frame) n.exc 1.50 sqm including cutting holes and making good reqd shape for hold fast block for new frame complete all as specified directed.
Material & labour factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-Charge.
Material & labour Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification
Material & labour for preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified
Material & labour for Preparation of new wood surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified
Providing and fixing factory made extruded aluminium casement windows (with provision for cooler) with 50 micron powder coating doubled panelled and double shutters consisting of frame and mullion of 101.60X44.45X1.29 mm and shutters made of 63.5X31.75X1.29mm and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and including 5mm thick glass in front shutters and stainless steel wire gauge 0.36mm dia and 1.40 aperature in inner shutters complete fixed in all respect as specified including supply and fixing following items :- (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 2 nos per leaf. (b) Powder Coated Aluminium Tower Bolt 150mm long - 2 nos per leaf. (c) Powder Coated Aluminium Handles 150 mm - 1 nos per leaf and incl hook and eye. Note: complete shutter window will be treated as single uit and paid as single unit
Supply & fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed in repair with stainless steel wire stapples, in steel/wooden frame complete all as specified and directed.
Supply & fixing for 3 mm figured glass sheet ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in Each pane complete all as specified.
Material & labour for Power coated (Minimum thickness of power coating 50 micron) Anodised aluminium frame, shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge.
Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K or approved equivalent, having 100% elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturer specifications. Product Make: Sikka/Fosroc/Dr fixit.
Supply and apply of rust remover cum passivator by brush in two coat @ 0.3 kg/m2/coat of Density: 1.01 Kg/l at 300C complete all as per manufacturer's instructions and all as specified. Note : (i) The application of rust removal shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of this work. Make/Product: Sika Rustoff 100 or equivalent from Fosroc/Dr fixit.
Supply and apply cementitious coating for corrosion protection having a cement base polymer modified rebar corrosion protection system by applying the first coat approx 1mm thick layer of product carbonation resistance 2mm of sikatop ArmatecR -108 or equivalent as specified corresponds to 20 mm of normal mortar;bond strength 1N/mm2 according to ASTM C 882-78 applying @ 4kg/m2 for two coats onto the prepared reinforcing steel with a medium-stiff brush.it is unavoidable that specified product will also be applied in the same way after a waiting time of 2-3 hours (+20C) complete all as per manufacturers instructions and all as specified. Make/Product: Sika Rustoff 100 or equivalent from Fosroc/Dr fixit. Note: (i) The application of cementitious coating for corrosion protection shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of this work.
Proving ,mixing & applying two components Epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturers apecification incl prepration of surface by chipping and throughly cleaning of surface complete wherever required and as per directions of Engineer-in-charge. Consumption: o.5 kg/m2 complete all as per manufacturers instructions and all as specified. Product requirements : complies with ASTM C 881 Type II Grade 2 class B+C. Make/Product: Sika Rustoff 100 or equivalent from Fosroc/Dr fixit. Note:(i) The application of epoxy bonding primer shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of this work.
Supply and apply a pre-batched one component polymer modifies cementitious patch repair mortar in 25mm thickness. Yield:approx 0.84 ltr/kg. System requirements:compressive strength =50 N/mm2 (28 days) according to ASTM C 109 : flexural strength = 3 N/mm2 (7 days) according to ASTM C 293-79 consumption of 2.1 kg/sqm/mm Make/Product: Sika Rustoff 100 or equivalent from Fosroc/Dr fixit. Note: (i) The applicator of polymer repair mortar shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of this work.
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement and fixing of chicken wire gauge where directed complete all as specified and as directed by Engineer-in-Charge. Note : WPC and chicken wire gauge will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge.
Material & labour for cement plastering 10mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Material & labour for cement plastering 5 mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment of any type/description from walls/RCC surfaces etc with mechanical means/grinder complete all as specified and directed.
Complete removal of existing treatment of any type/description from ceilings/RCC surfaces/soffits and chajjas etc with mechanical means/ grinder complete all as specified and directed.
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 0.5 to 1.00 mm as required for desired smoothness and levelling of surfaces in one or two layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed
Applying 02 coats of exterior emulsion weather proof paint (light shade) to external new plastered walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer as recommended by manufacturer of exterior emulsion complete all as specified and directed.
Applying one coat of exterior emulsion weather proof paint (light shade) to external old plastered walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surface complete all as specified and directed.
Applying 02 coats of oil bound distemper (light shade) to new plastered wall surfaces over complete all as specified and directed.
Applying one coat of oil bound distemper (light shade) to old plastered wall surfaces complete all as specified and directed.
Material & labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of old plastered of ceiling and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of old steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified
Material & labour for Preparation of old wood surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified
Demolition of cement concrete (unreinforced) of of any descriptions, in Ground floors (Floor Topping, Sub Base etc) not exc 150mm thick, above or below ground level complete all as specified and directed.
Material & labour for PCC with type D-2 1:4:8 (40 mm graded aggregate ) 75mm thick as in sub base. complete all as specified and directed.
Material & labour factory made Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set with grey cement and pigment , jointed and pointed in neat cement slurry in floors incl 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Material & labour for mild steel framed work as in brackets etc for cooler stands,supportings frame work for sun shade etc framed steps/stairs etc complete using MS railing/angle iron Steel bars gusset plate etc complete all as specified & directed complete.
Material & labour for Cement concrete (1:3:6) type B-1 using 20 mm graded stone aggregate as in plinth protection/ floor finish, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints filled with Bituminous mastic asphalt complete all as specified and directed by Engineer-in-Charge.
Material & labour for Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
Taking down carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc removing materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of credit and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with PVC modular top cover plates of suitable size for mounting of modular type switches/sockets/regulators including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting chases and making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engr-in-charge. Notes: (i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in unit rate quoted for this item. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth.(iii) -Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item.
All as per Sl item No 102.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
All as per Sl item No 102.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed.
All as per item No 102.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH copper earth wire for switch socket combination 3 pin 15 amps on independent board.
Supply & fix in replacement of Modular switch 1 way, 6 Amps, 1 module, 230 volts complete all as specified.
Supply & fix in replacement of Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified.
Supply & fix in replacement of Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified.
Supply & fix in replacement of Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified.
Supply & fix in replacement of Modular Fan regulator step type, 120 watts, 2 module complete fixed as in repair all as specified.
S&F ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed
New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 20 mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge.
S & F in replacement Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 18/20W 6500K of capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge.
S & F in replacement Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 10 Watt 6500K of capacity ,10 watt,2 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge.
Supply and fix surface mounted LED luminaire of capacity 20 W ( pressure die-cast aluminium liminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver complete all as specified and directed by Engr-in-charge.
Supply and fix Exhaust fan AC single phase 230/240 v of size 450 mm sweep heavy duty 1400 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louver complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED flat panel 2 x 2 ft size fully diffused surface mounted fitting (grid/gypsum type) 36-40 watt, 5700K/3000 K warm/cool white with powder coating and CRCA front cover incuding frame with provision of PVC flexible copper conductor cable from ceiling rose to light fittings as in repair complete all as specified and directed by Engr-in-charge.
Supply and fix Ceiling fan 1200mm sweep energy efficent as per latest specifications having service value more than or equal to 4.5 and suspended from fan hook including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to ceiling fan complete all as specified & directed by Enginner-in-charge.
M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through New PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 (two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring.
M & L for Sub main wiring with two single core 10 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit of suitable dia including 10.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 10.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 10.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring.
M & L for Sub main wiring with 04 (Four) single core 16.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through New PVC concealed conduit of suitable dia including 16.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note1:- 4 Runs of 16.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 16.00 Sqmm Copper conductor as earth wire shall be measured as one unit) Note 2 : Rate quoted for this item shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of suitable size dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in and making good to facing where required pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth.
M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
S & F MCCB, 4 Pole, 63 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
S & F MCCB, 4 Pole, 100 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
Supply and fix epoxy power coated MCCB distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size.
S & F Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP54 protection complete all as specified & directed by Engr-in-charge.
Supply and fix Sheet metal enclosure 12 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP54 protection complete all as specified & directed by Engr-in-charge.
S & F MCB , SPN, 240 Volts ,63 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge.
S & F MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge.
S & F MCB, single pole 240 volts 63 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge.
S & F Sheet metal enclosure DB TPN 4 ways double door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link flush mounting type, drilling holes for incoming and out going cables complete with IP-43 protection complete all as specified and directed by Engr-in-charge
S & F MCB, TPN, 63 A for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
Supply and fixed SPN earth metal plug 240 volts with 20 amp SP MCB with a two pin and earth plug and socket complete all as specified and directed.
Jawandha Enterprises (BID ID -3396175)
Buttar Construction Co. (BID ID -3396106)
ANIL KUMAR AND CO (BID ID -3396127)
Arneja Builders (BID ID -3392894)
DELTA CONSTRUCTION CO (BID ID -3396072)
m/s panchmukhi builders (BID ID -3395803)
FAVOURITE ENGINEERS (BID ID -3395240)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .