Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹42.7 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹47.4 L+₹4.7 L (11.0%)Rejected-Finance MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | ₹47.4 L+₹4.7 L (11.0%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹48.3 L+₹5.7 L (13.3%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | ₹48.3 L+₹5.7 L (13.3%) | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹48.7 L+₹6.0 L (14.1%)Rejected-Finance | ₹48.7 L+₹6.0 L (14.1%) | L4 | Rejected-Finance Rejected being L4 |
| 5 | L5₹49.3 L+₹6.6 L (15.5%)Rejected-Finance AT ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | ₹49.3 L+₹6.6 L (15.5%) | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹40.4 L
EMD Value
₹80,800
Closing Date
9 Mar 2024, 6:00 pmClosed
GE(AF) CHABUA
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR/MAINTENANCE OF CERTAIN E/M WORKS AT VARIOUS LOCATIONS UNDER GE(AF) CHABUA
2024_MES_642841_1
509/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(AF) CHABUA
As per tender documents
7 documents required · 7 mandatory
₹500
GE(AF) CHABUA
₹80,800
Yes
3 Apr 2024
17 Feb 2024
11 Mar 2024
17 Feb 2024
9 Mar 2024
1 Mar 2024
22 Feb 2024 - 27 Feb 2024
Amount
SCH 'A' PART-I
Supply and fixing in repairs ball bearing 6201 suitable for 1200 mm sweep ceiling fan complete all as specified and directed.
Supply and fixing in repairs ball bearing 6202 suitable for 1200 mm sweep ceiling fan complete all as specified and directed.
Supply and fixing in repairs Gun metal bush suitable for 1200 mm sweep ceiling fan complete all as specified and directed.
Supply and fixing in repairs rubber insulator (reel type) complete all as specified and directed.
Supply and fixing in repairs Capacitor 2.5 mfd epoxy filled type copper wound complete all as specified and directed.
Supply and fixing in repairs Capacitor 3.15 mfd epoxy filled type copper wound complete all as specified and directed.
Supply and fixing in repair Capacitor 4 mfd epoxy filled type copper wound complete all as specified and directed.
S&F 1200mm sweep BLDC 5 star ceiling fan with anti suicide fan rod, regulator enable motor power input 27 Watt with 10% tolerance, motor insulation B type, 230-240 V, 50 Hz AC supply complete set 3 blade, canopy, shackle including nut, bolts & washers as required complete all as specified and as directed. Note:- Old unsv ceiling fan will be deposited in MES store yard.
Supply and fix exhaust fan, steel body AC Single Phase, 230 V of size 300 mm sweep with blades and frame and louvers complete all as specified and directed at site. Note:- Old unsv fan will be deposited to MES store yard
M&L for painting of ceiling fan complete upto 1400 mm sweep with one coat of white paint/existing fan using spray machine painting with synthetic enamel paint including cleaning, washing of surfaces complete all as specified and directed.
Taking down geyser of any capacity from wall mountings after disconnecting electrical and water connections to carry out repairs and after repair fixing the same and making electrical and water connections, testing and commissioning complete all as specified and directed at site. Note:- Replacement of parts carried out will be measured and paid separately under respective items.
Taking out complete internal assembly i.e. inner tank, inlet and outlet assembly, heating element, thermostate etc of geyser of capacity 25 ltr, de-scaling the inner tank using appropriate chemical (descaling agent), cleaning and washing complete accessories, reassembling the same position complate all as specified and directed at site.
All as per ser item No 12 here-in- before but capacity of geyser 50 ltr.
M&L for painting of geyser up to 25 ltr with one coat of white paint as per existing colour using spray machine painting with synthetic enamel paint including cleaning, washing of surfaces complete all as specified and directed at site.
Repair of copper/steel inner container of geyser of 25 ltr capacity by necessary welding/brazing to check the water leakage, testing by applying specified air pressure to ensure leak proof, reassembling of geyser complete all as specified and as directed.
All as per ser item No 15 here-in- before but capacity of geyser 50 ltr.
Supply and fix in repair electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 ltr, BEE 5 star rated complete with all accessories such as safety valve,thermostate,NRV,connection pipe etc complete all as specified and directed at site.
Supply and fixin repair PVC heavy duty hot and cold water pipe 450 mm long fixed both side with brass ferrule nuts for 25/50 ltr capacity geysers for inlet/outlet pipe complete all as specified and directed at site.
S&F in repair neon indicator lamp (red/green) round/rectangular type for geyser complete all as specified and directed at site.
Supply and fix in repair of apparatus plate assembly of brass suitable for 25 ltr capacity geyser with collar, gasket, inlet and outlet facilities, housing to accommodate heating element, thermostate, thermal cut out complete all as specified and directed at site. Note:- Cost of drilling work, fixing accessories like nuts, bolts, washer/check nut etc and taking down and refixing of geyser are deemed to be included in the quoted rate.
All as per ser item No 20 here-in- before but capacity of geyser 50 ltr.
Supply and fix in repair glass wool of superior quality for geysers complete all as specified and as directed.
Supply and fixing in repair thermostate switch for geyser 25 ltr capacity complete all as specified and directed at site.
All as per ser item No 23 here-in- before but capacity of geyser 50 ltr.
Supply and fixing in repairs heating element 1.5 KW, AC 230 volts (Cup/Triangular type) complete all as specified and directed at site.
Supply and fixing in repairs heating element 2 KW, AC 230 volts (Cup/Triangular type) complete all as specified and directed at site.
Supply and fix in repair safety valve /fusible plug (brass) 15 mm bore for geyser complete all as specified and directed at site.
S&F in repairs PVC insulated sheathed copper conductor 2.5 sqmm 3 core as in connecting wire of geyser complete all as specified and directyed at site.
Supply and fixin repair PVC heavy duty hot and cold water pipe 450 mm long fixed both side with brass ferrule nuts for 25 ltr capacity geysers for inlet/outlet pipe complete all as specified and directed at site.
S&F in repair neon indicator lamp (red/green) round/rectangular type for geyser complete all as specified and directed at site.
Disconnection from socket outlets split type/window AC of capacity upto 2 ton of any brand, servicing by dusting, cleaning of indoor and outdoor units, rectifying gasleakage by applying necessary brazing, adjusting and rectifying faulty operation of elect and electronic remote control panels, replacing of perished elect wires for proper connection from voltage stabilizer, reinstalling the units to its original position, replacement of remote cell and testing complete all as specified and directed at site. Note:- Spare parts shall be measured & paid separately under relevant items.
All as per ser item No 31 here-in-before but refrigerators of capacity upto 280/310 ltr complete all as specified and directed at site
All as per ser item No 31 here-in-before but deep freezer of capacity upto 320/405 ltr complete all as specified and directed at site
Supply and fix in repair capilary tube (copper) suitable for window typwe AC/split Ac upto 2 Ton complete all as specified and directed at site.
Supply and fix in repair filter strainer (copper) suitable for 1.5/2 ton window/Split type AC complete all as specified and directed at site.
Supply and fix in repair Single Phase 230 Volts 50 Hz Voltage stabilizer suitable for 1.5/2 Ton split/window type AC , working range 150 - 280 V,time delay 2-4 min constant complete all as specified and directed at site. Note : Old unsv voltage stabilizer to be deposited to MES store yard
Servicing of cassette type split AC of capacity up to 3 ton of any brand, servicing by dusting, cleaning of indoor and outdoor units, rectifying gasleakage by applying necessary brazing, adjusting and rectifying faulty operation of elect and electronic remote control panels,replacing of perished elect wires for proper connection from voltage stabilizer, reinstalling the units to its original position,replacement of remote cell and testing complete all as specified and directed at site. Note:- Spare parts shall be measured & paid separately under relevant items.
Supply & fix in repairs outdoor fins type aluminium condenser of capacity 2 ton aplit AC complete all as specified and as directed.
Supply & fix in repairs outdoor fins type aluminium condenser of capacity 1.5 ton aplit AC complete all as specified and as directed.
Supply and fixing in repair starting capacitor 45+6 mfd suitable for 1.5 Ton AC complete all as specified and directed at site.
Supply and fixing in repair starting capacitor 55+6 mfd suitable for 2 Ton AC complete all as specified and directed at site.
Supply only starting capacitor 80/100 mfd complete all as specified and as directed
Supply only running capacitor 36 mfd complete all as specified and as directed
Supply only running capacitor 45/50 mfd complete all as specified and as directed
Supply only starting relay complete all as specified and as directed
Supply only contactor relay complete all as specified and as directed
Supply and fixing in repair relay suitable for split/window type AC of cap up to 2 Ton complete all as specified and directed at site.
S&F in replacement of compressor unit including necessary charging the system suitable for Window/Split type AC 1.5 Ton Capacity complete all as specified and as directed Note:- The rate quoted by the tendred shall be inclusive of cost of refrigerant Gas the charging Gas (R22/134A) as required for the cooling appliances.
S&F in replacement of compressor unit including necessary charging the system suitable for Window/Split type AC 2 Ton Capacity complete all as specified and as directed Note : The rate quoted by the tendred shall be inclusive of cost of refrigerant Gas the charging Gas (R22/134A) as required for the cooling appliances.
Supply only blower Fan (PVC) for split type AC upto 2 ton complete all as specified and directed at site.
Supply only inner blower Fan (PVC) for window type AC upto 1.5 ton complete all as specified and directed at site.
Supply and fixing in repair outdoor unit fan motor suitable for split type AC upto 2 ton complete all as specified and directed at site.
Supply only indoor fan motor for Split type AC upto 2.0 ton complete all as specified and directed at site.
Supply only indoor fan motor for window type AC upto 2.0 ton complete all as specified and directed at site.
Supply only swing motor for lower shutter of AC upto 2.0 ton capacity complete all as specified and directed at site.
Supply only charging of refrigerant R-22/307 complete all as specified and as directed.
Supply and fix in repairs PCB board for split type AC upto 1.5 ton capacity complete all as specified and directed at site.
Supply and fix in repairs PCB board for split type AC upto 2 ton capacity complete all as specified and directed at site.
Supply and fix in repairs PCB board for castle type AC upto 3 ton capacity complete all as specified and directed at site.
Supply and fix in repair display board for upto 2 Ton AC complete all as specified and directed at site.
Supply and fix in repair Sensor for indoor unit upto 2 Ton AC complete all as specified and directed at site.
Taking down carefully u/s PCB at existing existing loacation and repair and refixing at the same split/window type AC capacity upto 1.5ton/2 ton complete all as directed at site.
Supply & fix in replacement remote for split/window type AC up to 2 ton capacity complete all as specified and as directed
Taking out voltage styabilizer by disconnecting existing cable for u/s stabilizer of upto 5 KVA capacity including repairing/replacement of push on switch, relay transistor, diode, voltmeter, indicator lamp, high low cutout complete parts along with testing and commissioning and transporation charges from site to workshop and back complete all as specified and directed at site.
Taking out voltage styabilizer by disconnecting existing cable for u/s stabilizer of above 5 KVA but upto 7.5 KVA capacity including repairing/replacement of push on switch,relay transistor,diode,voltmeter,indicator lamp, high low cutout complete parts along with testing and commissioning and transporation charges from site to workshop and back complete all as specified and directed at site.
Supply and fix in repair copper pipe 1/2" dia complete all as specified and directed at site.
Supply and fix in repair copper pipe 1/4" dia complete all as specified and directed at site.
Supply and fix in repair brass service valve 1/2" dia complete all as specified and directed at site.
Supply and fix in repair brass service valve 1/4" dia complete all as specified and directed at site.
Supply and fix in repair water cooler tape capacity 40/80 ltr of any make/model complete all as specified and directed at site.
Supply and fix in repair thermostate switch of refrigerator/deep freezer of capacity 280/310 ltr of any make/model complete all as specified and as directed.
Supply and fix in repair over load relay of deep freeze rof capacity 320/405 ltr of any make/model complete all as specified and as directed.
Supply and fix in repair over load relay of refrigerator/deep freezerof capacity 280/310 ltr of any make/model complete all as specified and as directed.
Supply and fixing in repair heavy duty AC stand /outdoor unit mounting bracket suitable for 1.5/2 Ton AC including PCC and masonry work complete all as specified and as directed.
Supply and fix in repair over load relay of water cooler of capacity 40/80 ltr of any make/model complete all as specified and as directed.
Supply and fix in repair cooling coil of refrigerator/deep freezer of capacity 280/310 ltr of any make/model complete all as specified and directed at site.
Supply and fix in repair starting relay of refrigerator/deep freezer of capacity 280/310 ltr of any make/model complete all as specified and as directed.
Supply and fix in repair starting relay of deep freezer capacity 320/405 ltr of any make/model complete all as specified and directed at site.
S&F in repair, insulation tube (size 1/4''/1/2'') for split type AC s to insulation copper pipe complete all as specified and as directed.
Supply and fix in repair factory made sheet metal enclosure single pole & neutral with a two pin & earth plug and socket of 20 amps capacity complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. complete all as specified and as directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site.
M&L for point wiring with 1.5 Sq mm single core PVC insulated FRLSH unsheathed copper multi stranded conductor in and including PVC concealed conduit ISI marked of size 20/25mm inclusive of tees, bend, elbows etc including sunk Anodized pressed steel box 1.6 mm thick concealed in wall with white laminated colour 3 mm thick sheet cover of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster for One light /Fan point controlled by one one way switch complete all as specified and directed at site.
All as per ser item No. 84 here-in-before but point wiring with 2.5 sqmm for one 3 pin socket out let 5 Amps on the Independent board complete all as specified and as directed.
All as per Srl items No. 84 here-in-before but point wiring with 2.5 Sqmm for 15 Amp socket out let with 2.5 sqmm earth continuity wire complete all as specified and as directed
All as per Srl items No. 84 here-in-before but point wiring with 4 Sqmm for Heater or lectric equipment/ AC 1.5 / 2 Ton / more than or equal to 3 KW load with 4.0 sqmm earth continuity wire complete all as specified and as directed
All as per item No. 84 above but for one light point controlled by two way switch with 1.5 sqmm copper wire complete all as specified and as directed
All as per item No. 84 above but for one bell/ buzzer point with 1.5 sqmm copper wire controlled by one push button on the independent board complete all as specified and as directed
S&F switch bell push piano type 5 amp 230 volts complete all as specified and as directed.
S&F Switch Piano type single pole 5 amp 230 Volts complete all as specified and directed at site.
S&F socket outlet 2 in 1 , 5 pin, 5 amp complete all as specified and directed at site.
S&F Switch Piano type single pole 15 amp 230 v complete all as specified and directed at site.
S&F socket outlet 2 in 1, 6 pin, 5 and 15 amp complete all as specified and directed at site.
S&F ceiling rose surface type Bakelite 65x50 mm three terminals complete all as specified and directed at site.
S&F call bell Ding-Dong AC, 230 volts single pole complete all as specified and as directed.
S&F stepped type electronic fan regulator flush type complete all as specified and directed at site.
M&L for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair switch modular type, one way, 10 ams, 1 module 230 v complete all as specified and directed at site.
S&F in repair switch modular type, one way, 16 ams, 1 module 230 v complete all as specified and directed at site.
S&F in repair socket outlet, modular type, multipurpose, multipin, 6 amps, 1 module, 230 v complete all as specified and directed at site.
S&F in repair socket outlet,modular type, multipurpose, multipin, 6 amps/16 amps, 1 module, 230 v complete all as specified and directed at site.
S&F in repair modular type fan regulator, two module, 230 v complete all as specified and directed at site.
Supply and Fixing in replacement LED light fittings 36 watt Recess Mounting type with LED driver, mounting arrangement (Recess suitable for, 2x2 Grid, Hanging) including electric connection complete all as specified and directed at site.
Supply and Fixing in replacement LED panel light fittings 36 watt surface Mounting type, with mounting arrangement fixed with roof celing complete all as specified and directed at site.
Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed at site.
Supply and fixing in replacement of recessed mounted LED slim ceiling light fitting extruted aluminium housing and milky diffuser suitable for 1'x1' ceiling cell of 18 watt inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 3 core 1100 Volts grade all as specified and directed. complete all as specified and directed at site.
Supply and fixing in replacement surface and wall mounted LED batten fitting energy efficient fittings 10 watt complete, inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 3 core 1100 Volts grade all as specified and directed.
Supply and fix in repair round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed
Supply and fix MCB DB, TPN 4 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and as directed
S&F in repair MCCB 63 Amps, 415 V, 16KA 4 pole with thimbles/lugs and nut,bolts complete all as specified and as directed.
S&F in repair MCB SP 240 volt 6 to 32 Amps 'C' series 10 KA complete all as specified and directed at site.
S&F in repair MCB SPN 240 volt 32 Amps 'C' series 10 KA complete all as specified and directed at site.
S&F in repair MCB SPN 240 volt 40 to 63 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F in repair MCB TPN 415 volts, 40 to 63 amps 'C' Series 10 KA complete all as specified and directed at site.
M&L for sub main wiring with 4x10 sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor (FRLS), including two run of continuous PVC insulated FRLS copper stranded cable of size 10 sqmm for earth wire in and including surface/recessed, heavy duty PVC conduit complete all as specified and directed at site.
M&L for sub main wiring with 2x6.0 sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor (FRLS), including one run of continuous PVC insulated FRLS copper stranded cable of size 6.0 sqmm for earth wire in and including surface/recessed, heavy duty PVC conduit complete all as specified and directed at site.
M&L for sub main wiring with 2x4.0 sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor (FRLS), including one run of continuous PVC insulated FRLS copper stranded cable of size 4.0 sqmm for earth wire in and including surface/recessed, heavy duty PVC conduit complete all as specified and directed at site.
M&L for earthing complete with galvanized mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in ground connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm bore medium grade pipe with all fittings from the earth electrode fixed along pole or wall with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth pit to top of earth plate electrode including all excavation and earth work in any type of soil and removal of soil upto 50 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel, CI frame etc including taking down old unsv earthing complete all as directed. NOTES:- (i) The concrete pit shall be made in PCC 1:2:4 type B-0, using 12.5 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order (iii) Items includes cost of 7.5 metre earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
S&F Blanking Plates for covering of MCCB DB open space complete all as specified and directed at site.
SCH 'A' PART-II
Attending emergency breakdown of water supply installation where directed, taking out defective submersible pump set of capacity 5HP including column pipes from bore well, transporting pump set from site to work shop for repairs and back and lowering the pump set incl column pipes and making water and electric connection as per existing for running of pump motors complete all as directed. Note:- Spare Parts shall be measured & paid under relevant items.
Supply only Mitchel thrust bearing gunmetal V6 for 05 HP Submersible pump & motor (water supply & sewage), complete all as specified and as directed.
Supply only Intermediate piece for 5 HP Submersible pump & motor (water supply & sewage), complete all as specified and as directed.
M&L for remetlling work for shaft, grinding, polishing and finishing to required shape and size complete all as specified and as directed.
M&L for lowering of GI colum pipe 50 mm bore 6 mtr length by using Tripod and chain pulley system by jointing with each other with nutss, bolts and testing complete all as specified and directed at site.
M&L for flashing mud/silt in borewell casing pipeof size 200 mm bore by usingcompressor system all as directed.
Supply only Gun metal impeller suitable for 5 HP submersible pump complete all as specified and directed at site.
Rewinding of stator of submersible motor for 5 HP capacity with water proof insulated copper wire of existing guage to achieve the specified/required RPM including taking out old unserviceable winding ,complete all as specified and as directed
S&F in replacement of rubber gasket suitable for 50 mm GI flange complete all as specified and directed at site
S&F in replacement of GI flange suitable for 50 mm GI pipe complete all as specified and directed at site
Supply only GI colum pipe 50 mm bore, 6 mtr long complete all as specified and directed at site. Note:- Lowering of colum pipe in bore well will be measured and paid seperately.
Supply and fix in repair heavy duty PVC coated wire rope of size 10 mm dia suitable for 3 phase 5 HP Sumersible pump set complete all as specified and directed at site.
Supply and fix in replacement of flat 3 core 4 sqmm PVC insulated & PVC sheathed cable suitable for 3 phase 5 HP sumersible pump set complete all as specified and directed at site.
Supply and fix in replacement of 3 phase sumersible pump set, electric drive, 415 volt suitable for 100 to 150 mm borewell (Casing pipe size 100mm to 150mm, outlet pipe size 50mm complete all as specified and directed at site
Rewinding of stator of induction motor working on AC 440 / 230 volts for Centrifugal/monoblock pump set of 5 HP capacity with copper wire winding of appropriate existing guage including taking out old unserviceable winding complete all as specified and as directed.
S&F in repairs DOL Starter in sheet steel Enclosure with contactor & Pneumatic timers, 3 phase 415 volts, Relay range (7-10 Amps) suitable for 5 HP pump, and connection, testing, complete all as specified and as directed.
Taking up GI water mains from trenches for repair/rectification of leakage of GI water line of sizes 20 to 25 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed by Engineer-in-Charge. Note: Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
Taking up GI water mains from trenches/wall for repair/rectification of leakage of GI water line of sizes 40 to 50 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed by Engineer-in-Charge. Note: Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
Cleaning, desludging and removing of all scales and dirt from OH Pressed Steel Tank of capacity 9600 gallons installed at height of 40' staging and write (size of lettering 75 mm height) on indicated space at a height 3.5 mtr from ground level(ie. DATE OF CLEANING................, CAPACITY OF TANK ..................etc.) in black synthetic paint over white synthetic enamel paint all as directed and specified. NOTE : (a) Cost of staging/working platform involved shall be deemed to be included in the unit rate quoted. (b) consumption of bleaching powder for cleaning of each tank shall not be less than 12 Kg (c) Maximum two times cleaning of each tank in entire C.A. period.(Measured separately each time.
Labour only for cleaning of under ground sump of capacity 40 KL, including removal/taking out of sludge, cleaning of side wall by jute with necessary bleaching powder, complete all as specified and as directed. Note:- Cost of staging/working platform,bleaching powder involved shall be deemed to be included in the unit rate quoted.
Taking down old unsv corroded / rusted GI pipe ofs size upto 20 mm bore complete all as specified and directed.
All as per ser item No. 142 here in before but size of GI pipe 25 mm bore complete all as specified and directed.
All as per ser item No. 142 here in before but size of GI pipe 40 mm bore complete all as specified and directed.
All as per ser item No. 142 here in before but size of GI pipe 50 mm bore complete all as specified and directed.
All as per ser item No. 142 here in before but size of GI pipe 80 mm bore complete all as specified and directed.
S&F steel water tubing medium grade galvanised, with all fittings laid in trenches of size 20 mm bore complete all as specified and directed. Note:- Exc & earth work if required will be measured and paid seperately.
All as per ser item No. 147 here in before but size of GI pipe 25 mm bore complete all as specified and directed.
All as per ser item No. 147 here in before but size of GI pipe 40 mm bore complete all as specified and directed.
All as per ser item No. 149 here in before but size of GI pipe 50 mm bore complete all as specified and directed.
All as per ser item No. 147 here in before but size of GI pipe 80 mm bore complete all as specified and directed.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipe complete all as specified and directed.
All as per ser item No. 152 here in before but size of GI pipe 25 mm bore complete all as specified and directed.
All as per ser item No. 152 here in before but size of GI pipe 40 mm bore complete all as specified and directed.
All as per ser item No. 152 here in before but size of GI pipe 50 mm bore complete all as specified and directed.
All as per ser item No. 152 here in before but size of GI pipe 65 mm bore complete all as specified and directed.
Supply and fix Butter fly valve 80 mm dia with both side flanges ends fix with GI pipe 80 mm bore including any type of addition/alteration in existing GI pipe complete all as specified and directed at site.
Supply and fix sluice valve with cast iron body and gun metal/steel spindle and hand operated iron wheel, both ends flanged and drilled including nuts, bolts, washers and gaskets, PN 1.6 ISI Marked of 80 mm bore size including any type of adition/alteration of existing GI pipe complete all as specified and directed.
Supply fixing in repairs 80 mm dia Gun Metal foot valve as per site requirement all complete all as specified and directed.
Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
S&F in repair power contactors 3 pole rating 25 Amps, with auxilary contact 02 NO 02 NC complete all as specified and directed at site.
Construction of brick masonry valve pit/chamber of internal dimension 90 cm x 90 cm x 90 cm depth with sub class 'B' old size bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary breaking of the existing old chamber, excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m, complete all as specified and as directed.
All as per item No. 163 here-in-before above but valve pit chamber of internal dimension size 60x60x60 cm, complete all as specified and as directed.
S&F GI union 80 mm bore with exixting GI pipe including any type of adition/altertation complete all as specified and direct at site.
S&F GI union 65 mm bore with exixting GI pipe including any type of adition/altertation complete all as specified and direct at site.
S&F GI union 50 mm bore with existing 50 GI pipe including any type of adition/altertation complete all as specified and direct at site.
S&F Tee 80 mm bore with existing 80 mm GI pipe including any type of adition/altertation complete all as specified and direct at site.
Supply and utilization of calcium Hypochlorite having 60%-70% available chlorine content in granular form (granular based granular disinfectant) complete all as specified and directed.
SCH 'A' PART-III
Disconnecting of electrical supply and taking out LT switch gear of any make and type and servicing of LT switch gear by cleaning isolating contacts moving parts removing dust particles from bus bar chamber spout gear mechanism and moving parts, repair to motor charge spring mechanism tightening of nut & bolts of entire trolley components all as directed inserting in trolley, testing commissioning and putting on the supply on load complete all as directed. Note:- Spare parts which are required to replace of unserviceable spare parts will be paid under respective items.
S&F in repairs power factor improvement static condenser (capacitors) of required capacity, complete all as specified and directed.
Supply and fixing in repair power contactors 3 pole rating 30 Amps, with auxilary contact 01 NO 01 NC complete all as directed.
S&F in repairs APFC Relays with auto set function having steps 6 stage suitable for 415 Volts incl necessary connections all as directed.
S&F in repairs electronic protection Relays overload, single phasing, current unbalance, under current complete all as specified and directed.
Taking down Old burnt /Unserviceable HT/LT 95 sqmm underground PVC Cable heavy duty aluminum conductor LT 1100 V grade after disconnecting of electric connection all as specified and directed.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 95 Sqmm nominal cross section x 3.5 core complete all as specified and directed.
Taking down old unsv MCCB by disconnection of electric connection carefully from LT panel/LT feeder piller etc complete all as specified and directed.
S&F MCCB 4 pole, 415 volt 100 Amps with breaking capacity 16 kA, adjustable type 415 V, 50 Hz, complete all as specified and directed.
S & F MCCB 4 pole, 415 volt 125 Amps with breaking capacity 16 kA, adjustable type 415 V, 50 Hz, complete all as specified and directed.
S & F MCCB 4 pole, 415 volt 250 Amps with breaking capacity 36 kA, adjustable type 415 V, 50 Hz, complete all as specified and directed.
S & F MCCB 4 pole, 415 volt 400 Amps with breaking capacity 36 kA, adjustable type 415 V, 50 Hz, complete all as specified and directed.
S & F MCCB 4 pole, 415 volt 630 Amps with breaking capacity 50 kA, adjustable type 415 V, 50 Hz, complete all as specified and directed.
Overhauling/servicing of HT switch gear (VCB SF 6) of cap 11 KV comprising of following repairs:- (a) Tripping of the breaker,lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with trolly/SF6 for servicing/overhauling. (b) Servicing/inspecting/checking of circuit automatic safety shutter operation for serviceability and replacement of spares if required. (c ) Servicing/inspecting of circuit spout and circuit spout connections for RYB phases and replacement of spares if required. (d) Dismantling and checking of cross bar assembly,fixed contacts and current carrying carrying parts of the breaker,trolley insulated assembly and checking lamination with clamps,epoxy spout,isolator assembly etc. (e) Setting,reassembling,cleaning,adjustment of fixed contacts,main contact,arching contacts and chamber baffle pot assembly,moving contact for proper setting of auxiliary contacts operating mechanism. (f) Servicing/inspecting/checking of secondary sockets/bus bar earthing plug/earthing socket and replacement of spares if required.
M&L for dehydration & filteration of voltage stabilizer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filteration to achieved 40 KV at 2.5 mm gap complete all as specified and directed. Note:- (i) The filteration of the voltage stabilizer /isolation transformer oil shall be carried out at different locations of the AF Stn Chabua. (ii) The report before filteration & after filteration to be submitted by contractor . (iii) Oil for topping up will be measured and paid separately. (iv) Centrifuging Machine with all T&P & testing eqpt required for dehydration to be arranged by contractor.
Supply & toping up of new voltage stabilizer oil conforming to IS 335 std having dielectric strength 40 KV at 2.5 mm gap after initial dehydration complete all as specified and directed.
Dismantling and taking out old worn out reversible synchronus servo motor from the voltage stablizer and supply and fix new reversible servo motor single phase 230 Volts suitable for 300 KVA voltage stabilizer complete all as specified and directed.
Dismantling and taking out old worn out IC electronic control card including mother board, PCB from the voltage stablizer of capacity 300 KVA and supply and fix new IC electronic control card with mother board and PCB complete all as specified and directed.
S&F in repairs control wiring suitable for 300 KVA voltage stabilizer complete all as specified and directed.
S&F in repairs 12 pin connector suitable for 300 KVA voltage stabilizer complete all as specified and directed.
S&F in repairs R C network suitable for 300 KVA voltage stabilizer complete all as specified and directed.
S&F in repairs main big gear of voltage stabilizer complete all as specified and directed.
S&F in repairs small gear of voltage stabilizer complete all as specified and directed.
S&F in repairs high low voltage cut off circuit suitable for 300 KVA voltage stabilizer complete all as specified and directed.
S&F in repairs bush suitable for 300 KVA voltage stabilizer complete all as specified and directed.
S&F in repair protection relay CSDPR-V2 suitable for 11 KV HT panels SF 6 complete all as specified and directed.
Attending any electrical breakdown at ALG Pasighat such as faulty of HT 11KV/12KV HT switch gear, 315 KVA dry type transformer, 300 KVA Voltage Stablizer and any other electric break down by attending of auth service engineer to check and rectified the same all as specified and directed. Note:- Spare parts which are required to replace of unserviceable spare parts will be paid under respective items
Comprehensive maintenance and servicing of Dry type Transformer 315 KVA 11/0.433KV of Schineider Make by disconnecting of HT/LT connection, opening of doors etc complete cleaning of the inside compartment, core and coils by vaccum cleaner incl lead supports, tap changer terminal boards, bushings and other insulated surfaces be wiped clean with a dry cloth and all connections must be checked for tightness after cleanining upto the entire satisfication of Engr-in-charge the transformer must be meggered and connecting all connection and necessary testing Complete with U/m Scope of work (a) Cleaning of transformer from inside. (b) Testing the Transformer for IR Values. (c) Checking/servicing/calibration of WTI for healthiness (d) Magnetic Balance Test. (e) IR Value check before and after the work (f) Voltage Ratio Test at 440V. (g) DC Logic test (h) Commissioning of Transformer after completion of work (j) Test results obtained shall be recorded and produced to the Engr-in-Charge. (k) All Measuring equipments and T&P required shall be arranged by the contractor. (l) Any item /activity not listed / covered here above and required during /completing the overhauling work will have to be arranged by Contractor himself. (m) The rate quoted shall be deemed to include for disconnection of Transformer HV/LV terminations for testing work and re-connections after completion of repair work.
Taking down Old burnt /Unserviceable HT/LT 95 sqmm underground PVC Cable heavy duty aluminum conductor LT 1100 V grade after disconnecting of electric connection all as specified and directed.
Supply and laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sqmm complete all as specified and directed.
Supply and fix in repair steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall complete all as specified and as directed.
M&L in repair cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M&L in repair cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
S&Fix in repair power contactors MCX - 44, 2 NO+2NC, 4 pole power contactor complete all as specified and directed.
M&L for earthing complete with galvanized mild steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc including taking down old unsv earthing complete all as specified and as directed. NOTES:- (i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
S&F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15cm size complete all as specified and directed.
S&F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed.
Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
S & F in repairs Indicator Lamps (LED type) including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
Material and labour in repairs earth continuity conductor or main earthing lead or lightning conductor, 20 mm x 3.15 mm copper strip, fixed to wall on batten with saddles and fixing screws, PVC/ Porcelain insulators etc. or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including dismantling and removing existing old copper strip, complete all as specified and directed.
M&L for 11 KV Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp complete all as specified and directed.
SCH 'A' PART-IV
Labour only for servicing of 320 KVA DG Set with replacement of engine oil/lubricant, coolant, Oil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, etc complete all as specified and directed. Note:- (i) Engine oil, coolant and Spares to be measured and paid under respective items. (ii) Spare parts shall be of OEM or equivalent make from approved makes.
(a) Lube Oil Filter primary
(b) Lube Oil Filter secondary
(c) Fuel filter element (Set of two)
(d) Air Filter primary chamber
(e) Air Filter secondary chamber
(f) 'V' Belt,
Labour only for servicing of 35 KVA DG Set with replacement of engine oil/lubricant, coolant, Oil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, etc complete all as specified and directed. Note:- (i) Engine oil, coolant and Spares to be measured and paid under respective items here in after and necessary servicing should be done after an interval of running 500 Hrs or six months which will be earlier. (ii) Spare parts shall be of OEM or equivalent make from approved makes.
(a) Lube Oil Filter element (Primary & secondary)
(b) Fuel Filter element (Primary & secondary)
(c) Air Filter Element (Primary & secondary)
(d) 'V' Belt
(e) Hose for water pipe
Labour only for servicing of 15 KVA DG Set with replacement of engine oil/lubricant, coolant, Oil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, etc complete all as specified and directed. Note:- (i) Engine oil, coolant and Spares to be measured and paid under respective items here in after and necessary servicing should be done after an interval of running 500 Hrs or six months which will be earlier. (ii) Spare parts shall be of OEM or equivalent make from approved makes.
(a) Fuel Filter element,
(b) Lube Oil Filter element,
(c) Air Filter Element,
(d) Fan Belt,
(e) Hose for water pipe,
Supply and fixing in repair water Pump of 35 KVA diesel generator complete all as per specified and directed.
Supply and fixing in replacement of battery Charger 24 volt suitable for 320 KVA DG Set complete all as specified and directed.
Supply and fixing in repair Engine mounting for 35 KVA DG set of any capacity with complete Nuts bolts washer etc complete all as per specified and directed.
M&L in repairing of door of DG set canopy by Providing new hinges by making necessary arrangement complete all as directed.
Supply and fixing in repair of 4 Pole Power Contactors, type MCX 32, 2 NO + 2 NC, complete all as per specified and directed.
Supply and fixing in repair of 4 Pole Power Contactors, Type MCX 12, complete all as per specified and directed.
Supply and fixing in replacement of maintenance free battery with initially charged of capacity 12 volt, 150 AH complete all as per specified and directed.
Supply and fixing in replacement of maintenance free battery with initially charged of capacity 12 volt, 90 AH, complete all as per specified and directed.
Supply only Engine oil 15 W 40 for top up/refilling of all DG set of various capacity, model & location as per the direction of Engr-in-charge.
Supply only Coolant suitable for DG set complete all as per specified and directed.
Labour only for repair of self starter 12/24 volt, dismantling from DG set of Cap 320 KVA and shifting to workshop and back for and including carrying out following repair works:- Note:- Spares to be measured and paid under respective items here in after
(a) Armature
(b) Bush
(c) Brush
(d) Carbon soldering
(e) Solenoid switch Assy
(f) Carbon recker
Labour only for repair of self starter 12/24 volt, dismantling from DG set of Cap 35 KVA and shifting to workshop and back for and including carrying out following repair works:- Note:- Spares to be measured and paid under respective items here in after
(a) Bush
(b) Bush soldering
(c) Solenoid switch Assy
(d) Carbon recker
(e) Drive Assy
(f) Field coil
(g)Battery terminal with lead
Dismantling of radiator assembly from generating set of capacity 320 KVA DG set and re-fixing of the same after and including proper cleaning of the same with caustic soda and brazing the tube if any leakage complete all as directed.
Dismantling of radiator assembly from generating set of capacity 35 KVA DG set and re-fixing of the same after and including proper cleaning of the same with caustic soda and brazing the tube if any leakage complete all as directed.
Supply & fix in repair of AVR suitable for 35 KVA DG Set complete all as specified and as directed.
Supply & fix in repair of AVR suitable for 320 KVA DG Set complete all as specified and as directed.
S&F in repairs DG control unit suitable for 320 KVA DG set Kirloskar make DG sets including necessary connections and testing complete all as specified and as directed.
M&L for maintenance free chemical earthing system complete with 03 (three) nos copper bonded rods, 17.2 mm dia 3000 mm long electrode buried at suitable distance apart directly in ground, to bore holes of 120 mm dia vertically to a depth not less than 3.60 mtr deep below ground level with top edge of earth electrode at a depth not less than 100 mm below normal ground level, provision of clamps or brazed or both for each copper bonded rods made of copper and copper strip of size 25 x 3 mm & strip connection on the top of the electrode and copper strip of size 25 x 3 mm for inter connection of 03 nos copper bonded rods and laying at least 500 mm below in the ground and further connected to test point terminal block, including back filling of bore holes with advanced earth enhancing compound 96 kilogram (minimum) for artificial treatment to soil so as to achieve earth resistance below 01 Ohms as specified in para 19.140 of SSR Part-1 (2009), including provision of earthing pit in PCC(1:3:6) type C1 pre-cast cover RCC slab of size 400 x 400 x 50 mm with one handle made out of 8 mm dia round bar, including necessary earth work and three coats of white wash on plastered surface (exposed surfaces) and testing complete all as directed and including necessary earth work and testing complete all as specified and directed. Note:- Taking down old unserviceable dilapidated chemical earthing are included in quoted rate.
M&L for earthing complete with copper earth plate electrode 60 x 60 cm x 3.15 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including copper earth strip of size 20 x 3 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc including taking down old unsv one complete all as specified and as directed. NOTES:- (i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
M&L for earthing complete with galvanized mild steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 40 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc including taking down old unsv earthing complete all as specified and as directed. NOTES:- (i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
M&L for rewinding of Stator/Rotor coil of alternator/Rectifier Coil Unit of 320 KVA DG set with super enamelled/paper coated copper wire of existing gauge including all connected insulating material such as separator etc, varnishing, replacement of carbon bushes including disconnection/dismantling of electrical connections, foundation bolts, pulling out of rotor with proper care and reinsulation of burnt out rotor/stator after rewinding work including re-assembling and testing complete all as specified and as directed.
M&L for calibration of FIP of 320 KVA DG set including minor repair complete all as specified and as directed.
Attending day to day Street light complaints with skilled electrician (Street lights fitted on poles/buildings/High mast tower at height up to 12 mtr from ground level), repair/replacement of unserviceable accessories like LED drivers, copper/aluminium service connection wires, MCBs complete all as per the instruction of Engineer in Charge. Cost of T&P such as required tools, ladders, helmet, etc required for repair of street light/flood light complete all as specified and directed at site.. Note:- (a) Cost of spares and accessories will be measured and paid separately under relevant items. (b) Cost for taking down and re-fixing of street lights shall be deemed to be included in the unit rate quoted. (c) Any other items or parts (other than listed in Sch A) required for smooth functioning of street lights/ Security lights on pole from junction box bus bar to street light shall be provided by the contractor and rates for the same are deemed to be included in above item here in before nothing extra shall be paid on this account.
Supply and fix in repair LED driver suitable for 45 watt LED street light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 60 watt LED street light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 70 watt LED street light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 100 watt LED street light fitting complete all as specified and directed.
M&L for painting of street light poles tubular type 9 mtr long in two coats of aluminium paint over one coat of red oxide as primer including writing of poles nos complete all as specified and as directed.
Supply and laying in trenches or drawn through pipe or fixed on wall/poles, LT UG cable heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor of size 16 sqmm x 4 core including taking down old unserviceable cable complete all as specified and as directed.
Excavation in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, or for shafts, wells, manholes, pier holes, cable laying, sewage/water lines etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Supply and spreading dry coarse sand in trenches for protection of underground electric cable, spread in uniform 23 cm thickness and punned down gently to 18 cm complete all as specified and as directed. Note:- Punned thickness will be measured for payment.
Supply and laying well burnt Sub Class 'B' bricks locally available best quality laid in trenches perpendicular to UG cable above sand cushioning for cable protection complete all as specified and as directed.
Supply & fix GI tube light grade of 50mm size laid in trenches or fixed on wall, floor or on pole for cable protection complete all as specified and directed.
Cutting bituminous road/path for passing of elect cable through GI pipes and making good to the cut surfaces by concreting with PCC 1:3:6 to match with the adjacent surfaces complete all as specified and directed.
Supply and fix street light bracket, bend to 120 degree angle, made out of 40 mm bore, galvanized iron, light grade tubing (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts, bolts and washers, etc. and two coats of synthetic enameled paint over a coat of red oxide primer including taking down the old unserviceable one complete all as specified and directed.
S&F in repairs junction box 200x140x95mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed on poles with flat aluminium clamps of size 20 x 3 mm, nuts, bolts, washers etc. complete all as specified and as directed.
Supplying and fixing in repairs 1100 volts grade, heavy duty cable ISI marked with PVC insulated, multistranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, flat or circular of size 2 core x 4 sqmm, complete all as specified and as directed.
Supplying and fixing in repairs 1100 volts grade, heavy duty cable ISI marked with PVC insulated, multistranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, flat or circular of size 2 core x 6 sqmm, complete all as specified and as directed.
Supplying and fixing in repairs 1100 volts grade, heavy duty cable ISI marked with PVC insulated, multistranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, flat or circular of size 2 core x10 sqmm, complete all as specified and as directed.
S&F in replacement of LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 45 W capacity after taking down the old unserviceable one complete all as specified and directed.
S&F in replacement of LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 60 W capacity after taking down the old unserviceable one complete all as specified and directed.
S&F in replacement of LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 70 W capacity after taking down the old unserviceable one complete all as specified and directed.
S&F in repair flood light fitting mounted on high mast light of 100 watt energy saving, environmental friendly, long life, made up of pressure die-cast aluminium housing with toughened glass and high power LEDs IP66 protection, suitable for highlighting architectural facade and general purpose lighting after taking down the old unsv one complete all as specified and directed.
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load, current rating 630 Amps, 415 volts complete all as specified and directed.
M/S DURGA CONSTRUCTION & CO
M/S R G Construction
M/S P R SINGH AND SONS
M/S MAHATO ENTERPRISE
Singhs Construction
M/S RK Trading
M/S Build Tech
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .