Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC NANAK TOWER 3RD FLOOR SEVOKE ROAD SILIGURI | L1 | Accepted-AOC L1-Accpeted | |
| 2 | L3₹11.0 L+₹28,507.37 (2.66%)Rejected-Finance 76 1 GURU SADAY DUTTA SARANI NORTH BHARAT NAGAR SILIGUR | L3 | Rejected-Finance Higher than L1. | |
| 3 | L4₹11.4 L+₹64,149.22 (5.98%)Rejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L4 | Rejected-Finance Higher than L1. |
Tender Value
Refer Docs
EMD Value
₹21,770
Closing Date
7 Apr 2022, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER, MALDA MECHANICAL DIVISION,PHED
Office of the Executive Engineer, Malda Mechanical Division, PHE Dte. Doulatpur PHE complex, P.O. Maliha, Dist. Malda, PIN 732102
Supply, delivery, installation and commissioining of Air Blower and repairing and rectification of PDB panel of Blower Room at Water Treatment Plant of Balupur Water Supply Scheme under Malda Mechanical Division, PHE Dte.
2022_PHED_371528_1
WBPHED/EE/MLMD/NIeT_13 of 2021-2022
Open Tender
Electrical Work/ Equipment
Item Rate
45 days
Doulatpur PHE complex, P.O. Maliha, Dist. Malda
Please refer Tender documents.
5 documents required · 5 mandatory
₹21,770
Yes
25 Aug 2025
22 Mar 2022
11 Apr 2022
22 Mar 2022
7 Apr 2022
22 Mar 2022
240 days
Amount
Supply, delivery and storage at site of following materials for Main Incomer Panel
Twin Lob Air blower of capacity 892.15 m3/hr. at differential pressure (G) of 0.35 Kg/Cm2 with common base frame, suction Filter, Safety Valve, V-Belts, V-Belt Guard, Suction Silencer, NRV Pressure Gauge with Isolation valve and Syphon, Fixing Nuts-Bolts, Drive and Driven Pulleys, Interconnecting pipes, Set of Foundation Bolts, Anti Vibration Pads and Gaskets all complete.
Energy Efficient (IE2), T.E.F.C. Sqirrel cage, 4 Pole, 1440 RPM Motors with Enclosure coforming to Protection IP55, Horizontal Foot Mounted (B3), Continuously rated (S1) suitable for operation on 415+/- 10% V, 3 Phase 50Hz +/- 5% AC supply with ambient 50 degree C, class "F" insulation with Temparature Rise Limited to class "B" and conforming to IS 12615:2011/IEC 600034-30-2014 (Make- CGL/ABB or any approved of PHED Vendor)
Installation and Commissioning of all items in Sl.No.1 .01 to 1.02 including supply of all erection materials, pipe supports, valve supports, allied civil works as required for installation of Blower set. including termination of LT cables through GI conduits / trays or underground and earthing protection as per IE rules and as per direction of EIC.
Charges for necessary disconnection of power line and dismentling of existing damaged electrical and electronics spares following necessary precautions from blower Panel installed at WTP site all complete upto entire satisfaction of EIC.
Supply,delivery and storage at site of following materials for Blower Panel:
125 A, 415 V 4P Microprocessor base MCCB of Breaking capacity 25kA with fixed thermal and fixed magnetic setting incl. extended door mounted rotary operator
100A, 415 V 4P Microprocessor base MCCB of Breaking capacity 25kA with fixed thermal and fixed magnetic setting incl. extended door mounted rotary operator
32 A, 415 V Four Pole MCCB of Breaking capacity 25kA with fixed thermal and fixed magnetic setting incl. extended door mounted rotary operator
On/OFF Auxiliary switch
70 Amp. 3 pole power contactor having coil voltage 240V, 50Hz. (2 NO+ 2 NC)
Star-Delta timer. (3-120 sec)
28-40 Amp. over load realy (Contactor mounted)
6 A, 240/415 V SP MCB of Breaking capacity 10kA & C characteristic
250 A 4 way terminal
150 A 4 way terminal
96 sqmm, 3 Phase digital Voltmeter with LED indicators having current accuracy 0.5 as per latest IEC 61010-1.
96 sqmm, 3 Phase digital Ammeter with LED indicators having current accuracy 0.5 as per latest IEC 61010-1.
LED type indicating lamp (Red- 14 nos., Green -14 nos. & Yellow 5 nos.)
Push button switches (start/stop) with 1 NO/ 1 NC Block (Red 4 nos. & Green 4 nos.)
1.5 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (90m/coil)
2.5 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (90m/coil)
6 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (90m/coil)
16 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (90m/coil)
50 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (100m/coil)
Charges for fitting fixing of supplied spares (as in items in sl. no. 3.01 to 3.15) along with necessary mechanical and electical hardware as supplied by agency (such as screws, nut-bolts, washers, cable tie, pvc tape, sockets etc) making internal connection by supplied suitable size Cu wire (as in items in sl. no. 3.16 to 3.20) along with reconnection and testing of the starter panel under load condition (8 hrs. continuous running) by checking motor current data ( Delta operation) or other releavent operating parameters all complete as per entire satisfaction of EIC.
MAKE AS PER DEPARTMENTAL APPROVED VENDOR LIST CIRCULATED VIDE MEMO NO.PHE/IV/2277/W-181/19 DATED- 25/09/2019
Add GST @12%
Add Cess @ 1%
DEY ENTERPRISE
ALPHA ENTERPRISE
DEY ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .