| Sl No | Description | Qty | Unit | CMK Projects Private Ltd., L1 | GANAPATHY ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Reciprocating Air Cooled Type (10 HP) Rating Vaccum Pump as per following provisions.
As per IS 12827 / 1987 & ISO 7396 / 1987 Specification
a) Vaccum Pump - 10 HP - 1 No.
b) Electric Motor - 10 HP - 1 No.
c) DOL Starter with OLR - 1 No.
d) Vaccum Switch - 1 No.
e) Vaccum Gauge - 1 No.
f) Control Frame with Fittings - 1 No.
g) Suction Scrubber - 1 No.
h) V-Belts - 1 No.
i) GI & MS Fittings - 1 No.
j) Brass Fittings - 1 No.
k) Exhaust Silencer - 1 No.
i) Base Frame for Motor and Vaccum Pump - 1 set
m) Pilot Line with Fittings - 1 set,
Vaccum Room & Air Compressor Room Inside | 1 | Nos | 5,05,680 ₹5,05,680 Lowest | 5,30,000 ₹5,30,000 |
| 2.00 | Supply, installation, testing and commissioning of MS Fabricated Vertical Mounted Type 1000 liters capacity Vaccum Receiver with inlet and outlet and drain holes provided suitable to operate with vaccum pump, etc., as directed by the Departmental Officers. | 1 | Nos | 1,09,851 ₹1,09,851 Lowest | 1,15,000 ₹1,15,000 |
| 3.00 | Ward Vaccum Unit with Gauge both mounted on a collection jar of capacity 600 ml and with a wall bracket for mounting it on the wall. The collecion jar should be made of unbreakable polycarbonate materials which is fully auto cleavable at 134 degree centigrade as per standard specification and as directed by the Departmental Officers and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. The rate includes cost of silicon hose with SS nipple on either side. | 110 | Nos | 2,048 ₹2,25,280 Lowest | 2,145 ₹2,35,950 |
| 4.00 | Supply, installation, testing and commissioning of Compressed Air System of Reciprocating Oil Free Air Compressor Belt Driven Type 10 HP Air Compressor with following provisions.
As per IS 12827 / 1987 & ISO 7396 / 1987 Specification Compressor package consists of following:
a) 10 HP Air Compressor - 1 No.
b) Electric Motor 10 HP - 1 No.
c) Dol Starter - L&T - 10 HP - 1 No.
d) Base Frame Kit (for Motor and Compressor) - 1 set
e) Pressure Swith - 1 No.
f) Pressure Gauge - 1 No.
g) NRV and Pilot Fittings - 1 No.
h) Delivery Tube - 1 No
i) Foundation Bolts & Anchor Fasteners - 1 Lot
j) Belt Guard - 1 No.
k) Refrigerator Type Air Dryer-40 cfm. capacity-1 No.
l) Drain Ball Valve - 1 No.
m) Air Outlet Ball Valve - 1 No.
Vacuum Room & Air Compressor Room Inside Accessories: Non-Return Valves, Air Pressure Switch,
Pressure Gauge, Isolation Valves, Air Filters etc.,
Inter connecting piping: Mild Steel Pipe of 2 with fittings. | 1 | Nos | 5,31,195 ₹5,31,195 Lowest | 5,56,500 ₹5,56,500 |
| 5.00 | Supply, installation, testing and commissioning of MS
Fabricated Vertical Mounted Type 1000 liters capacity Compressed Air Receiver with inlet and outlet and drain holes provided suitable to operate with vaccum pump etc as directed by the Departmental Officers. | 1 | Nos | 1,09,851 ₹1,09,851 Lowest | 1,15,000 ₹1,15,000 |
| 6.00 | Oxygen manifold arrangements of 2 banks x 12 cylinder each wing with semi automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low /
high pipeline pressure and malfunctioning of system.
1) Mainfold top frame with provision for connecting 12 cylinders on right bank and 12 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder spport middle angle frame for claping 2 x 12 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg. / CM2. The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. | 1 | Nos | 2,08,373 ₹2,08,373 Lowest | 2,18,300 ₹2,18,300 |
| 7.00 | Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per minute. It should meet strict permission and dumbling standard. The meter body should be made of brass materials. The humidifier bottle should be made of unbreakable polycorbonate material and auto cleavable at 134 degree centigrate. The rate includes flow meter and its accessories (silicon tube with mask).
The cost of materials including transport, etc., complete as per standard specification and as directed by the Departmental Officer and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. | 110 | Nos | 1,711 ₹1,88,210 Lowest | 1,800 ₹1,98,000 |
| 8.00 | Bed Head Panel of size 1m length, height 0-0.30 cm and depth of 4. The aluminium powder coated with requirement colour for provision points of O2-2 Nos., Air 1 No., Vaccum 1 No. with double electrical socket with switch 2 Nos. with 2 set with 1V - bottle holder fixing to the wall hanging including monitor stand etc., complete. | 20 | Nos | 20,485 ₹4,09,700 Lowest | 21,500 ₹4,30,000 |
| 9.00 | DIN / BS Standard Outlet Points with from loading, inner connecting and brass body. Single press inlet with two stage process first stage for patient usage and second stage in parking mode, covered by plastic cover duly colour indicated with specific gas name and non interchangeable for other gases. The cost of materials inclduing transport, etc., complete, as per standard specification and as directed by the Departmental Officers | 260 | Nos | 4,851 ₹12,61,260 Lowest | 5,100 ₹13,26,000 |
| 10.00Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. | |||||
Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
25 Sept 2025, 3:00 pmClosed
The Superintending Engineer, PWD.,
O/o. The Superintending Engineer, PWD., Buildings (C and M) Circle-1, Chepauk, Chennai-5
Providing Medical Gas Pipeline System arrangements for CMRL (Medicine Block) building in Government Kilapuk Medical College Hospital, Kilpauk, Chennai-10
2025_PWD_603596_2
PWD/BCMC1/43/2025-26
Open Tender
Civil Works
Lump-sum
120 days
Kilpauk
Refer Tender Condition
7 documents required · 7 mandatory
₹0
₹42,000
20 Jan 2026
18 Sept 2025
25 Sept 2025
18 Sept 2025
25 Sept 2025
18 Sept 2025
Amount
Supply, installation, testing and commissioning of Reciprocating Air Cooled Type (10 HP) Rating Vaccum Pump as per following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specification a) Vaccum Pump - 10 HP - 1 No. b) Electric Motor - 10 HP - 1 No. c) DOL Starter with OLR - 1 No. d) Vaccum Switch - 1 No. e) Vaccum Gauge - 1 No. f) Control Frame with Fittings - 1 No. g) Suction Scrubber - 1 No. h) V-Belts - 1 No. i) GI & MS Fittings - 1 No. j) Brass Fittings - 1 No. k) Exhaust Silencer - 1 No. i) Base Frame for Motor and Vaccum Pump - 1 set m) Pilot Line with Fittings - 1 set, Vaccum Room & Air Compressor Room Inside
Supply, installation, testing and commissioning of MS Fabricated Vertical Mounted Type 1000 liters capacity Vaccum Receiver with inlet and outlet and drain holes provided suitable to operate with vaccum pump, etc., as directed by the Departmental Officers.
Ward Vaccum Unit with Gauge both mounted on a collection jar of capacity 600 ml and with a wall bracket for mounting it on the wall. The collecion jar should be made of unbreakable polycarbonate materials which is fully auto cleavable at 134 degree centigrade as per standard specification and as directed by the Departmental Officers and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. The rate includes cost of silicon hose with SS nipple on either side.
Supply, installation, testing and commissioning of Compressed Air System of Reciprocating Oil Free Air Compressor Belt Driven Type 10 HP Air Compressor with following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specification Compressor package consists of following: a) 10 HP Air Compressor - 1 No. b) Electric Motor 10 HP - 1 No. c) Dol Starter - L&T - 10 HP - 1 No. d) Base Frame Kit (for Motor and Compressor) - 1 set e) Pressure Swith - 1 No. f) Pressure Gauge - 1 No. g) NRV and Pilot Fittings - 1 No. h) Delivery Tube - 1 No i) Foundation Bolts & Anchor Fasteners - 1 Lot j) Belt Guard - 1 No. k) Refrigerator Type Air Dryer-40 cfm. capacity-1 No. l) Drain Ball Valve - 1 No. m) Air Outlet Ball Valve - 1 No. Vacuum Room & Air Compressor Room Inside Accessories: Non-Return Valves, Air Pressure Switch, Pressure Gauge, Isolation Valves, Air Filters etc., Inter connecting piping: Mild Steel Pipe of 2 with fittings.
Supply, installation, testing and commissioning of MS Fabricated Vertical Mounted Type 1000 liters capacity Compressed Air Receiver with inlet and outlet and drain holes provided suitable to operate with vaccum pump etc as directed by the Departmental Officers.
Oxygen manifold arrangements of 2 banks x 12 cylinder each wing with semi automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) Mainfold top frame with provision for connecting 12 cylinders on right bank and 12 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder spport middle angle frame for claping 2 x 12 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg. / CM2. The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.
Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per minute. It should meet strict permission and dumbling standard. The meter body should be made of brass materials. The humidifier bottle should be made of unbreakable polycorbonate material and auto cleavable at 134 degree centigrate. The rate includes flow meter and its accessories (silicon tube with mask). The cost of materials including transport, etc., complete as per standard specification and as directed by the Departmental Officer and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification.
Bed Head Panel of size 1m length, height 0-0.30 cm and depth of 4. The aluminium powder coated with requirement colour for provision points of O2-2 Nos., Air 1 No., Vaccum 1 No. with double electrical socket with switch 2 Nos. with 2 set with 1V - bottle holder fixing to the wall hanging including monitor stand etc., complete.
DIN / BS Standard Outlet Points with from loading, inner connecting and brass body. Single press inlet with two stage process first stage for patient usage and second stage in parking mode, covered by plastic cover duly colour indicated with specific gas name and non interchangeable for other gases. The cost of materials inclduing transport, etc., complete, as per standard specification and as directed by the Departmental Officers
Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.
12mm OD 0.90mm thick copper pipe
15mm OD 0.90mm Thick Copper Pipe
22mm OD 0.90mm Thick Copper Pipe
28mm OD 0.90mm Thick Copper Pipe
42mm OD 0.90mm Thick Copper Pipe
Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification.
15mm Isolation Valve
22mm Isolation Valve
28mm Isolation Valve
42mm Isolation Valve
DIGITAL ALARM SYSTEM: Four Channel Microprocessor Controlled Alarm for Pneumatic & Vacuum Services should have the following Features: 1. Digital Display of Line Pressure for all the services with factory calibrated Pressure Sensors. 2. Colour Coded LED Display of Line Pressure Status (High-Caution- Normal-Caution-Low) 3. Audible Alarm for High & Low Pressure Condition. 4. Test and Alarm Acknowledge (Mute) facility. (Alarm Acknowledge (Mute) time span is Programmable from 1 to 60 min) 5. Programming Facility of Alarm limits from front panel (Password protected) 6. Facility to connect to remote alarm box by potential free contacts provided in alarm box. 7. Small and Compact design. Light Weight (3kg) 8. Imported Highly Sensitive Gas Pressure Sensors & USA/CE Marked Power Supply. 9. Mounted on a Powder Coated MS Box. 10. Mounted on a Elegant Designed PVC Box or Aluminium Metallic Box (Powder Coated). 11. Nut & Nipple are to be Provided for Connection with Pneumatic supply Line. 12. Low Voltage Internal Operation with Input Power Supply of 220V AC. 13. Battery Backup 14. Easy Wall Mounting Facility.
2 gas alarm system
3 gas alarm system
Supply, Installation, testing and commissioning of Combined electrical panel for air compresssor - Vacuum system.
Supply, Installation, testing and commissioning of valve box, CE certified / UL listed and having valid CDSCO licence with model No.
GANAPATHY ELECTRICALS (BID ID -1472069)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_724179.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .