Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC CHATTAPADMAPUR RAMNAGAR DIST PURBA MEDINIPUR | PURBA MEDINIPUR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹8.1 L+₹886 (0.11%)Rejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | L2 | Rejected-Finance 2nd Lowest Bidder | |
| 3 | L3₹8.1 L+₹1,240 (0.15%)Rejected-Finance KANKARDANGA | L3 | Rejected-Finance 3rd Lowest Bidder | |
| 4 | Rejected-Technical 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | - | Rejected-Technical due to insufficient documents |
| Sl No | Description | Qty | Unit | TAPAN ELECTRICS L1 | B. ENGINEERING CO. L2 | SASTIK ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & Delivery of Hi-Wall Split Air Conditioner having the following specification:- 1) Cooling capacity Nominal :- 1.8 TR ( Ton of Refrigeration)
2) Cooling Capacity in BTU/hr :- Minimum 21600 or Higher 2) Minimum BEE Star rating - 2 Star or Higher IS compliance - IS 1391 3) Refrigerant- R410A/R32 4) Compressor- Rotary/Scroll 5) Evaporator & Condensor Coil : Copper 6) Operating Outdoor Temparature = 50°C and above 7) Power Supply- 230 V, 50 HZ (Tolerance as per applicable standard) 8) Cordless Remote Arrangement with all modernized provision of temperature setting, Fan speed option (Low/Medium/High) Auto Swing. (Make- Mitsubishi Electric MS/MU- AJZ22VF or equivalent model of Mitsubishi Heavy Industry/O-General)
(On-site ten (10) year warranty on Compressor, and five(05) years on Outdoor PCB, and one (01) Year comprehensive warranty by OEM) | 10 | Set | 61,200 ₹6,12,000 Lowest | 62,000 ₹6,20,000 | 61,700 ₹6,17,000 |
| 2.00 | Installation, Testing & commissioning of 1.5/1.9/2.0/2.1 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC. | 10 | Set | 3,000 ₹30,000 | 2,000 ₹20,000 Lowest | 2,750 ₹27,500 |
| 3.00 | Supply andlLaying of 5/8” or 1/2"& 1/4" dia (Soft drawn) Cu. Pipes (As per standard) with tube thickness 0.6mm incl. 9mm thick nitrile rubber insulation, , insulation tape, fastner, etc as necessary as per direction of EIC.
Copper Pipe Make: Hitachi Ryoku/Mandev/Rajco &
Nitrile Rubber Insulation Make: Armacel/Accoflex/K-flex | 150 | RM | 200 ₹30,000 Lowest | 210 ₹31,500 | 230 ₹34,500 |
| 4.00 | S & Laying of 3/4 Core 2.5 sqmm PVC insulated & unarmoured copper wire (Make:- Havells/Polycab/RR Kable/Finolex) through 13/19 mm dia 3 mm thick (Flexible or rigid) pipe for 1.5/2 Tr. Split AC machine with max saddling with max 1 mtr distance as per the direction of EIC. | 150 | RM | 100 ₹15,000 | 85 ₹12,750 Lowest | 90 ₹13,500 |
| 5.00 | Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of 18/19/ 25 mm dia. incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. (Make:- Supreme/Astral/Finolex/Skipper) | 150 | RM | 80 ₹12,000 | 75 ₹11,250 Lowest | 86 ₹12,900 |
| 6.00 | Supply and Fixing of Timer DB (concealed in wall or Surfaced as per the site condition)
1) 230V, Upto 16 A capacity 24 Hrs Analog Electromechanical Time Switch (Make-Lauritz Knudsen (L&T) Cat No:- AUTS03ANA00/Siemens/Schneider)
2) 2 Pole Power Contrcator (L&T-MNX 25-2P Cat No-CS90240/Siemens/Schneider ),
3) 20A SP MCB. [Make-Siemens/Schneider/Lauritz Knudsen (L&T)]
4) 32A DP Isolator. (Make-Siemens/Schneider/Lauritz Knudsen (L&T) )
5) Toggle Switch. (Make-Siemens/Schneider/Lauritz Knudsen (L&T) or equivalent make)
5) (2+12 Way) SPNDB (Make-Siemens/Schneider/Lauritz Knudsen (L&T) 6) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power.
7) The complete arrangement must be wiring by 1/2.5/4/6 Sq mm PVC insulated Cu wire(Make:- Gloster/Polycab/Havells) with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make-Siemens/Schneider/Lauritz Knudsen (L&T)/Legrand) | 11 | Set | 8,500 ₹93,500 | 8,750 ₹96,250 | 8,000 ₹88,000 Lowest |
| 7.00 | Dismantling , Servicing, Overhauling indoor and outdoor unit and different size copper pipe leakage repair including Shifting of 2.0 TR split AC Machine from Old HDU to the Office Room of Hospital. | 2 | Job | 1,000 ₹2,000 | 2,000 ₹4,000 | 500 ₹1,000 Lowest |
| 8.00 | Supply & Fixing 240 V, 25 A, Modular type starter (Make:- Legrand-Myrius/Crabtree-Murano/North-West- Stylus Plus /Schneider -Zencello) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire, etc. | 2 | Set | 900 ₹1,800 Lowest | 920 ₹1,840 | 1,000 ₹2,000 |
| 9.00 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make:- Legrand-Myrius/Crabtree-Murano/North-West- Stylus Plus /Schneider -Zencello) , without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. | 2 | Set | 700 ₹1,400 | 600 ₹1,200 Lowest | 850 ₹1,700 |
| 10.00 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make:- Legrand-Myrius/Crabtree-Murano/North-West- Stylus Plus /Schneider -Zencello) & necy.Connections. | 10 | Set | 200 ₹2,000 | 180 ₹1,800 Lowest | 250 ₹2,500 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
8 Sept 2025, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SENIOR SUPERINTENDING ENGINEER
GOVERNMENT OF WEST BENGAL OFFICE OF THE SENIOR SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound,Midnapore,Paschim Medinipur
SITC of AirCondition Machine at Blood Centre of Haldia Sub Divisional Hospital under Purba Medinipur Electrical Division.
2025_WBPWD_897203_1
WBPWD/SSE/SWEC/NIQ44/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
PURBA MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER
30 Oct 2026
1 Sept 2025
10 Sept 2025
1 Sept 2025
8 Sept 2025
4 Sept 2025
4 Sept 2025
Amount
Supply & Delivery of Hi-Wall Split Air Conditioner having the following specification:- 1) Cooling capacity Nominal :- 1.8 TR ( Ton of Refrigeration) 2) Cooling Capacity in BTU/hr :- Minimum 21600 or Higher 2) Minimum BEE Star rating - 2 Star or Higher IS compliance - IS 1391 3) Refrigerant- R410A/R32 4) Compressor- Rotary/Scroll 5) Evaporator & Condensor Coil : Copper 6) Operating Outdoor Temparature = 50°C and above 7) Power Supply- 230 V, 50 HZ (Tolerance as per applicable standard) 8) Cordless Remote Arrangement with all modernized provision of temperature setting, Fan speed option (Low/Medium/High) Auto Swing. (Make- Mitsubishi Electric MS/MU- AJZ22VF or equivalent model of Mitsubishi Heavy Industry/O-General) (On-site ten (10) year warranty on Compressor, and five(05) years on Outdoor PCB, and one (01) Year comprehensive warranty by OEM)
Installation, Testing & commissioning of 1.5/1.9/2.0/2.1 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC.
Supply andlLaying of 5/8” or 1/2"& 1/4" dia (Soft drawn) Cu. Pipes (As per standard) with tube thickness 0.6mm incl. 9mm thick nitrile rubber insulation, , insulation tape, fastner, etc as necessary as per direction of EIC. Copper Pipe Make: Hitachi Ryoku/Mandev/Rajco & Nitrile Rubber Insulation Make: Armacel/Accoflex/K-flex
S & Laying of 3/4 Core 2.5 sqmm PVC insulated & unarmoured copper wire (Make:- Havells/Polycab/RR Kable/Finolex) through 13/19 mm dia 3 mm thick (Flexible or rigid) pipe for 1.5/2 Tr. Split AC machine with max saddling with max 1 mtr distance as per the direction of EIC.
Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of 18/19/ 25 mm dia. incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. (Make:- Supreme/Astral/Finolex/Skipper)
Supply and Fixing of Timer DB (concealed in wall or Surfaced as per the site condition) 1) 230V, Upto 16 A capacity 24 Hrs Analog Electromechanical Time Switch (Make-Lauritz Knudsen (L&T) Cat No:- AUTS03ANA00/Siemens/Schneider) 2) 2 Pole Power Contrcator (L&T-MNX 25-2P Cat No-CS90240/Siemens/Schneider ), 3) 20A SP MCB. [Make-Siemens/Schneider/Lauritz Knudsen (L&T)] 4) 32A DP Isolator. (Make-Siemens/Schneider/Lauritz Knudsen (L&T) ) 5) Toggle Switch. (Make-Siemens/Schneider/Lauritz Knudsen (L&T) or equivalent make) 5) (2+12 Way) SPNDB (Make-Siemens/Schneider/Lauritz Knudsen (L&T) 6) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power. 7) The complete arrangement must be wiring by 1/2.5/4/6 Sq mm PVC insulated Cu wire(Make:- Gloster/Polycab/Havells) with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make-Siemens/Schneider/Lauritz Knudsen (L&T)/Legrand)
Dismantling , Servicing, Overhauling indoor and outdoor unit and different size copper pipe leakage repair including Shifting of 2.0 TR split AC Machine from Old HDU to the Office Room of Hospital.
Supply & Fixing 240 V, 25 A, Modular type starter (Make:- Legrand-Myrius/Crabtree-Murano/North-West- Stylus Plus /Schneider -Zencello) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire, etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make:- Legrand-Myrius/Crabtree-Murano/North-West- Stylus Plus /Schneider -Zencello) , without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make:- Legrand-Myrius/Crabtree-Murano/North-West- Stylus Plus /Schneider -Zencello) & necy.Connections.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire ( Make:- Havells/Polycab/RR Kable/Finolex ) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (For AC Machine)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes as to GS.
B. ENGINEERING CO. (BID ID -6903173)
SASTIK ENTERPRISE (BID ID -6908606)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .