Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.7 L+₹3.1 L (8.21%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Rejected-Finance Being L2 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
21 Sept 2024, 6:00 pmClosed
GE (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
Upkeep and servicing of water supply distribution system, OHT cleaning and related items in Fort Cantt Prayagraj.
2024_MES_666644_1
8742/E8
Open Tender
Civil Works - Others
Item Rate
120 days
Prayagraj
As Per NIT
6 documents required · 6 mandatory
₹500
GE (East) Prayagraj
₹96,000
Yes
27 Dec 2024
19 Jul 2024
28 Sept 2024
19 Jul 2024
21 Sept 2024
2 Aug 2024
19 Jul 2024 - 26 Jul 2024
Amount
S&F of sluice valve heavy duty both ends flanged and drilled type nominal pressured rating PN-1.6, conformed to IS 780 of 1980 complete with cast iron body bonnet wedge stuffing box galvanished thrust plate, spindle made of high tensile stainless steel cast iron hand operated wheel with cap top nuts, bolts. washers wedge nut body seal ring and wedge facing run lead tin braise, compressed fibre bolts and nuts, gland packing of superior quality including 6mm thick rubber gasket joint including taking downc and compelete size of 80mm bore
Ditto all as per item No. 1 but 100mm bore
Ditto all as per item No. 1 but 150mm bore
M & L for disconnecting and stopping of incoming and outgoing pipes by means of hesian cloth to avoid choking of distribution pipe lines, removing complete water from the over head tank cleaning of over head tanks any staging hight of capacity 50000 gallon in Fort Cantt,Allahabad including writing date of cleaning on over head tank on pillar with synthetic enamel paint, including painting with one coat synthetic enamel paint after cleaning of steel surface and pipes with existing shade and apply two coat of weather proof paint with admixtures (in any colour or tint as approved by GE) on wall/ concrete surface / pillar /dome and ceiling of RCC OH tank on external surface after brooming/scraping down of old surface with preparation of surface with writing on OH tank on pillar date of cleaning , capacity of tank & including repairs of wire net/mesh of stainless steel wire 1.4 mm dia fixed with tacks of ventilation of tank as directed by Engineer- in -Charge comprising of pre operations mentioned below:- (a) In the first step dewatering of the tank shall be carried out by opening drain out valve (b) In the second step,removal of left over dirty water and sludge with suitable sludge removal pump shall be carried out.
Contd/... (c) In the third step,cleaning of internal walls,floors,ceiling of tank shall be carried out by high jet pressure of machine of water shall not be less than 80-120 bar and ensured that no dirt,sludge or moss remain on surface of tank. (d) In the fourth step,the remaining sludge shall be removed from the floor with the help of industrial vaccum cleaner. (e) In the fifth step,tank shall be sterilized by spraying anti bacterial agent using same high pressure machine. This agent should be of agent tank cleaning or equivalent as approved by GE. Dose of this agent must be as per OCED guidelines 423 adopted on 17 Dec 2011 (i.e. 1 litre of concentrated agent mixed with 40 ltrs water to produce mixture 1 litre of this mixture shall be used to disinfect 10000 ltrs capacity tanks and higher capacity tanks in position. (f) In the last step,treatment of inside of tank by exploring UV radiation to kill further suspended or floating bacteria. This is to be done by glowing UV lamp inside tank as per NSF standard 55-1991(I.e. 16000 µW-sec/Cm² or in other words 3-5 minutes according to capacity of tank) Note:- (i) The work should be got executed through reputed specilized water tank cleaner and shall be approved by GE before commecement of work.
Contd/... (ii) After completion of work a certificate regarding bacteria free shall be submitted to Deptt by the contractor for satisfaction of Engineer-in-Charge duly signed. (iii) Coloured photographic evidence of stage wise cleanig of OHT shall be submitted in duplicate to the Deptt. iv) Date of cleaning and capacity of tank will be written on OHT with paint with letters or figures (Block, Roman) not less then 300mm high complete all as directed. (v) The cost for above requirement is deemed to be included in the unit quated rates and no extra payment shall be made on this account & not any claim entertaned at later stage on this purpose.
M & L for disconnecting and stopping of incoming and outgoing pipes by means of hesian cloth to avoid choking of distribution pipe lines, removing complete water from the UG Sump tank cleaning of UG Sump tanks any staging capacity 25000 gallon in Fort Cantt,Allahabad including writing date of cleaning on UG Sump tank on pillar with synthetic enamel paint, including painting with one coat synthetic enamel paint after cleaning of steel surface and pipes with existing shade and apply two coat of weather proof paint with admixtures (in any colour or tint as approved by GE) on wall/ concrete surface / pillar /dome and ceiling of UG Sump tank on external surface after brooming/scraping down of old surface with preparation of surface with writing on UG Sumpon pillar date of cleaning , capacity of tank & including repairs of wire net/mesh of stainless steel wire 1.4 mm dia fixed with tacks of ventilation of tank as directed by Engineer- in -Charge comprising of pre operations mentioned below:- (a) In the first step dewatering of the tank shall be carried out by opening drain out valve (b) In the second step,removal of left over dirty water and sludge with suitable sludge removal pump shall be carried out.
Contd/… (c) In the third step,cleaning of internal walls,floors,ceiling of tank shall be carried out by high jet pressure of machine of water shall not be less than 80-120 bar and ensured that no dirt,sludge or moss remain on surface of tank. (d) In the fourth step,the remaining sludge shall be removed from the floor with the help of industrial vaccum cleaner. (e) In the fifth step,tank shall be sterilized by spraying anti bacterial agent using same high pressure machine. This agent should be of agent tank cleaning or equivalent as approved by GE. Dose of this agent must be as per OCED guidelines 423 adopted on 17 Dec 2011 (i.e. 1 litre of concentrated agent mixed with 40 ltrs water to produce mixture 1 litre of this mixture shall be used to disinfect 10000 ltrs capacity tanks and higher capacity tanks in position. (f) In the last step,treatment of inside of tank by exploring UV radiation to kill further suspended or floating bacteria. This is to be done by glowing UV lamp inside tank as per NSF standard 55-1991(I.e. 16000 µW-sec/Cm² or in other words 3-5 minutes according to capacity of tank) Note:- (i) The work should be got executed through reputed specilized water tank cleaner and shall be approved by GE before commecement of work.
Contd/... (ii) After completion of work a certificate regarding bacteria free shall be submitted to Deptt by the contractor for satisfaction of Engineer-in-Charge duly signed. (iii) Coloured photographic evidence of stage wise cleanig of UG Sump shall be submitted in duplicate to the Deptt. iv) Date of cleaning and capacity of tank will be written on UG Sump with paint with letters or figures (Block, Roman) not less then 300mm high complete all as directed. (v) The cost for above requirement is deemed to be included in the unit quated rates and no extra payment shall be made on this account & not any claim entertaned at later stage on this purpose.
Supply and Mixing Calcium based granular disinfectant for water treat ment drinking water with 60 70 % chlorine contents by volume conforming to IS-15738 in sealed plastic containers of 45 kg , as required on monthly basis with manufacturer's chlorine test certificate and manufacturer's date marked not more than 02 week old , complete all as specified and directed. NOTES:- (i) Approval of chemical (Calcium granular) shall be given after verification of test certificates of chemical of various manufactures and other factors like chemical and safety and health hazard aspects of usage of chlorination (ii) The brand/make of the chlorination of chemical must be stated before procurement and certified by govt laboratory that it is free from the technical strength stahbility health safety and operation point of view this product is ued for drinking water applications for consumption by humans and the brand /make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory.
S&F in repair for of single headed Hydrant valve inlet type 'A' with 63 mm/65 mm dia bore with 63 mm /65 mm dia bore female coupling instanataneous outlet ISI marked IS:5290 including cost of mild steel flange pacing washer including taking down of old Hydrant valve all as directed by Engr-in-Charge.
S & F in repair flanged GI pipe for fire hydrant of size 65mm bore and 60 cm long of medium grade (ISI MARK) having a drilled GI flanges welded at both ends with the help of nut and bolts complete all as specified & directed.
M&L for painting of panel board with one coat of synthetic enamel paint including preparation of the existing surface including scartching of old paint wherever required , rubbing & cleaning ofthe greasy spot by means of kerosene oil or other suitable chemical with safety precaution & all disconnected electrical connections are connected and before painting shut down complete all as specified & directed.
Supply and fixing in repairs, commissioning & testing complete of DIGITAL WATER LEVEL INDICATION DEVICE, operating on single phase supply direct display in 19 mm size digit system in meter/cm of water over head tank ensuring alarm while water fall or rise over pre-determined limit with the following description : the entire unit must operate through a compact electronic circuit, which must ensure reliable operation at 230 V + 5% with reliable in digit display and alarm at low and high level or over head tank.
S&F in repair PVC insulated & FR PVC round sheathed copper conductor multi core round ( flexible)industrial cable 1100 volt with bright annealed electrolytic bare copper conductor for voltage 1100 volts grade of size 0.5 sqmm,4 core confirming to IS-694-1990 making connection to water level indicator complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or laying of cables/pipes etc. and getting out in soft/loose soil complete all as specified and directed.
Cutting of road (bituminus/concrete) in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for shafts, valve pits, wells, cesspits, manholes, pier holes,laying of cables/pipes etc. not exceeding 1.5 m in depth and getting out in road cutting soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply,Laying, jointing & testing for 80 mm bore galvanized steel water tubes, 'medium grade', galvanized with new fittings & accessories such as Tee, elbow, bend, socket, reducer etc , laid in trenches including taking out old/ unserveciable existing pipe complete all as specified & directed. NOTE for item No. 16 to 21 : Excavation and earth work shall be measured and paid separately under respective items of BoQ.
Supply,Laying only, jointing & testing for 50 mm bore galvanized steel water tubes, 'medium grade', galvanized with new fittings & accessories such as Tee, elbow ,bend, socket, reducer etc., laid in trenches including taking out old/ unserveciable existing pipe complete all as specified & directed.
Supply,Laying only, jointing & testing for 40 mm bore galvanized steel water tubes, 'medium grade', galvanized with new fittings & accessories such as Tee,elbow,bend,socket,reducer etc, laid in trenches including taking out old/ unserveciable existing pipe complete all as specified & directed.
Supply, Laying only, jointing & testing for 25 mm bore galvanized steel water tubes, 'medium grade', galvanized with new fittings & accessories such as Tee, elbow, bend, socket, reducer etc, laid in trenches including taking out old/ unserveciable existing pipe complete all as specified & directed.
Supply, laying, jointing & testing for 20 mm bore of galvanized steel water tubes, 'medium grade', ISI marked, galvanized with fittings & accessories such as Tee, elbow, bend, socket, reducer etc, laid in trenches including taking out old/ unserveciable existing pipe complete all as specified & directed.
Supply, laying, jointing & testing for 15 mm bore of galvanized steel water tubes, 'medium grade', ISI marked, galvanized with fittings & accessories such as Tee, elbow, bend, socket, reducer etc, laid in trenches including taking out old/ unserveciable existing pipe complete all as specified & directed. NOTE :Excavation and earth work shall be measured and paid separately under respective items of BoQ.
Material & labour for laying, jointing,commissioning & testing 150 mm dia Ductile iron welded double flanged Pipe centrifugally cast , class K-9 conforming to IS, in any length, jointing with rubber / fibre joints in trenches including taking out old/ unserveciable existing pipe complete all as specified and directed.
Material & labour for laying, jointing,commissioning & testing 100 mm dia Ductile iron welded double flanged Pipe centrifugally cast , class K-9 conforming to IS, in any length, jointing with rubber / fibre joints in trenches including taking out old/ unserveciable existing pipe complete all as specified and directed.
Supply and fix in repairs Gun-metal gate valve with iron wheel head, screwed both ends for iron pipe of size 15mm bore.
Supply and fix in repairs Gun-metal gate valve with iron wheel head, screwed both ends for iron pipe of size 20mm bore.
Supply and fix in repairs Gun-metal gate valve with iron wheel head, screwed both ends for iron pipe of size 25mm bore.
Supply and fix in repairs Gun-metal gate valve with iron wheel head, screwed both ends for iron pipe of size 40mm bore.
Supply and fix in repairs Gun-metal gate valve with iron wheel head, screwed both ends for iron pipe of size 50mm bore.
M & L for run lead joint for cast iron spigot and socket pipes and fitting of size 80mm bore including taking down existing lead joint complete all as specified and directed.
M & L for run lead joint for cast iron spigot and socket pipes and fitting of size 100mm bore including taking down existing lead joint complete all as specified and directed.
M & L for run lead joint for cast iron spigot and socket pipes and fitting of size 150mm bore including taking down existing lead joint complete all as specified and directed.
Drilling and tapping cast iron water mains (in position) for branch connections for 15 mm bore internal dia including necessary fittings and mild steel brackets of suitable size of pipe complete all as specified & directed.
Drilling and tapping cast iron water mains (in position) for branch connections for 20 mm bore internal dia including necessary fittings and mild steel brackets of suitable size of pipe complete all as specified & directed.
S&F repairs non return sluice valve 150 mm bore cast iron both end flanged including material and labour for joints, repairs of rubber/ fibre joints gasket , nut, bolts , washers in repairs, length as per existing NRV complete including taking down unserviceable NRV all as specified and directed by Engineer-in-charge.
M&L for repair of 80 mm bore CI pipe to leakage/ replace of cast iron pipe line, joints including taking out burning out of lead joints, repairing the joints with new lead wool including using old lead obtained from existing available lead, testing for leakage proof pipe line in position completely including excavation , returning, in filling & testing complete all as specified & directed.
M&L for repair of 100 mm bore CI pipe to leakage/ replace of cast iron pipe line, joints including taking out burning out of lead joints, repairing the joints with new lead wool including using old lead obtained from existing available lead , testing for leakage proof pipe line in position completely and remarking the same as per the MES procedure for making new joints including excavation , returning, in filling & testing complete all as specified & directed.
M&L for repair of 150 mm bore CI pipe to leakage/ replace of cast iron pipe line, joints including taking out burning out of lead joints, repairing the joints with new lead wool including using old lead obtained from existing available lead , testing for leakage proof pipe line in position completely and remarking the same as per the MES procedure for making new joints including excavation , returning, in filling & testing complete all as specified & directed.
M&L for detecting faults such as no water supply, leakage,block, broken ..etc in external water supply distribution system in pump houses/Md Accn/OTM in the NAA and rectifiying the defects in any type of pipe and joints for water supply system including replacing of unserviciable defective water supply accessories and complete all as specified & directed. Note :- (i) Spares shall be measured and paid under respective item of schedule . (ii) Essential material like, complain slip book, Tubing Cutter ,Hacksaw ,Hole saw kit ,Pipe and tube benders Mole grips ,Thread sealing tape,Pliers ,Press fitting systems,Ratcheting pipe threader set,Pipe wrench, Adjustable wrench to the defect fault shall be deemed to be included in the quoted rate.
Collecting sample of water in sample bottles and testing of water sample in different pockets of Fort Cantt area Allahabad, in respect of the following parameters, to get it tested from State Public health laboratory or NABL Accredited Lab, complete all as specified and directed . Note : The parameter to be tested as per IS :10500-2012 : shall be Colour, Odour, tubidity, Ph value, Total dissolved solids, Aluminium, Ammonia, detergents, Barium, Boron, Calcium, Chlormines, Chloride, Copper Fluoride, Free Residual chlorine, Iron , Magnesium, Manganese, Mineral Oil, Nitrates, Silver, Sulphate, Sulphide.
Lifting and taking out complete submersible pump set 17.5 HP to 41 HP along with the any size of column pipes with the help of chain pulley block from borewell after disconnecting electrical & water connections with safety precaution from panel, disconnecting from suction and delivery pipe lines, disconnecting column pipes,examine electric cable to ensure its actual condition and jointing the cable, re-assembling and lowering pump with column pipe & motor into bore well complete, connecting, testing and commissioning alongwith connected items such as mild steel column pipe with nylon rope, cable, re-fixing with new nuts & bolts, rubber packing for smooth functioning inclusive in unit quoted rates, with proper alignment and making electrical connection complete all as specified and directed.
Disconnecting the all electric & mechanic connection from pump with electric motor 3 phase, 415 volts, 50 c/s of capacity 25 HP of electric motor/submersible pump of any make from the set, rewinding the motor with PVC insulated copper winding wire of existing gauge and size including all other winding material such as leatheriest paper, tapes, sleeves etc and suitable size bearing , if required including and testing complete for smooth functioning and satisfied by Engineer-in-Charge & reassembling and re-fixing with true alignment and testing and commissioning complete all as specified & directed by Engineer-in-Charge.
Disconnecting the all electric & mechanic connection from pump with electric motor 3 phase, 415 volts, 50 c/s of capacity 33 HP of electric motor/submersible pump of any make from the set, rewinding the motor with PVC insulated copper winding wire of existing gauge and size including all other winding material such as leatheriest paper, tapes, sleeves etc and suitable size bearing , if required including and testing complete for smooth functioning and satisfied by Engineer-in-Charge & reassembling and re-fixing with true alignment and testing and commissioning complete all as specified & directed by Engineer-in-Charge.
Disconnecting the all electric & mechanic connection from pump with electric motor 3 phase, 415 volts, 50 c/s of capacity 41 HP of electric motor/submersible pump of any make from the set, rewinding the motor with PVC insulated copper winding wire of existing gauge and size including all other winding material such as leatheriest paper, tapes, sleeves etc and suitable size bearing , if required including and testing complete for smooth functioning and satisfied by Engineer-in-Charge & reassembling and re-fixing with true alignment and testing and commissioning complete all as specified & directed by Engineer-in-Charge.
Following spare parts of pump will be replaced under item No-43 as mentioned above :-
Supply only upper and lower housing bushes of any material complete suitable for 17.5 HP to 41 HP complete.
Supply only stainless steel bushes each set suitable for 17.5 HP to 41 HP submersible motor complete
Supply only 'O' ring kit and oil seal kit suitable for 17.5 HP to 41 HP complete
Supply only thrust bearing excel carbon suitable for 17.5 HP to 41HP complete.
Supply only thrust bearing plate suitable for 17.5 HP to 41HP complete
Supply only sand guard stainer suitable for 17.5 HP to 41HP complete.
Supply only water seal suitable for 17.5 HP to 41HP complete
Supply only gun metal bush of pump shaft suitable for 17.5 HP to 41 HP complete.
Supply only impeller bush of gun metal suitable for 17.5 HP to 41 HP complete.
Supply only neck ring of impeller as per existing size suitable for 17.5 HP to 41 HP including necessary lathe work complete all as specified and directed by Engineer-in-Charge.
Repair of bowl bush of housing by proper machine work of housing and pump shaft & repairs of bowl bush for 17.5 to 41 HP complete all as specified and directed.
S&F for repairs jointing the submersible cable by means of jointing material & making the leak proof jointing complete all as specified and directed by Engineer-in-Charge.
S & F in repair contactor 3 pole, ML4 (2NO + 2 NC) current rating 60 Amp
S & F in repair contactor 3 pole, ML3 (2NO + 2 NC) current rating 40Amp
S & F in repair Single phasing preventor relay for submersible pumps complete all as specified and directed.
M&L in repairs of directly operated thermal overload relay range 28-42 Amp.
Disconnecting the electric connection of unserviceable monoblock submersible pump with motor, transporting to work shop for repair, disconnecting the all electric & mechanic connection from pump with electric motor 3 phase, 415 volts, 50 c/s of capacity 12.5 HP of electric motor / submersible pump of any make from the set, rewinding the motor with super enamelled copper winding wire of existing gauge and size including all other winding material such as leatheriest paper, tapes, sleeves etc, Bush,'O' ring, Sand guard, water seal and suitable size bearing if required including varnishing, heating, drying and also repair/ repairs of spare parts of pump such as bowl bush, gun metal bush, neck ring and testing complete for smooth functioning and satisfied by Engineer-in-Charge & reassembling and re-fixing with true alignment and testing and commissioning complete all as specified & directed by Engineer-in-Charge.
S&F FRP in repairs of dosing tank of capacity 100Ltrs (Dia 480mm, height- 575 mm) lid connecting port hole for pouring chlorination chemical and water including provision of mounting of motor and dosing pump, wall level gauge. Make : Aquafit Model- VST 1006 Declibac technologies PVTor equivalent all as specified and approved by Accepting Officer.
S&F in repairs of electronic dozing pump of capacity 10 ltr/hour including dismantling of existing dozing pump complete all as directed by Engineering-in-Charge.
S & F in repairs , connecting, testing and commissioning Direct Online Starter with single phase protection,max relay range 11-18 Amp suitable for 7.5 HP, 3 Phase, 415 volts, 50 HZ, having all standared accessories complete all as specified and directed.
S&F in repairs, connecting, testing and commissioning fully Automatic Star Delta Starter in sheet steel enclosure with single phase protection and max relay suitable for 40 HP, 3 Phase, 415 volts, 50 HZ, having all standard accessories complete all as specified and directed.
S&F in repairs, connecting, testing and commissioning fully Automatic Star Delta Starter in sheet steel enclosure with single phase protection and max relay suitable for 25 HP, 3 Phase, 415 volts, 50 HZ, having all standard accessories complete all as specified and directed.
S&F in repairs of submersible cable heavy duty PVC insulated and sheathed 25 sqmm size 3 core conductor flat fully water proof 1100 volt grade complete all as specified and directed.
S&F in repairs of submersible cable heavy duty PVC insulated and sheathed 16 sqmm size 3 core conductor flat fully water proof 1100 volt grade complete all as specified and directed.
Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frame).(Ventilator and Window)
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4.00 Sqm each (Without taking off shutters from the frame).(Doors and Window)
S & F Pressed steel frames factory made for doors out of 1.25 mm thick PBI sheet with one of more rebates including necessary flat iron lugs,hinges, lock strike plate, hinges etc complete, size of frame 125 x 60mm including tarring ends and back of chowkats and lugs including back filling of PCC 1:3:6 for chowkats & PCC 1:2:4 for block for hold fast including two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces all as specified and directed
S & F 35 mm thick, 2nd class hard wood glazed and skelton shutter, open rebated and prepare to receive glass, gauzed etc(without sash bars) edges of framming plain , chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR PART I Section 8 clause 8.24(a) supplied and fitted to chowkhat complete all as specified and directed.
S & F Steel rolling shutters 1.25 mm thick, with out Ball bearing for rolling as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer;erected in position as indicated, complete: push pull or manual type complete all as specified and directed0
S & F Ball bearing for rolling shutters complete all as specified and directed
S & F in repairs 35 mm thick flush door shutter, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Material & Labour preparation of new wooden surfaces over10 cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer complete all as specified and directed.
S & F Aluminium anodised handle extruded section of size 150mm complete all as specified and directed.
S & F 100 mm butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed.
S & F Aluminium alloy, anodised, sliding door bolt of length 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed.
S & F Aluminium anodised barrel tower bolts extruded section of size 150 mm, all as complete all as specified and directed.
S & F 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor Door Stopper 140 mm complete all as specified and directed
Supply & Fix Steel windows/ventilator with tubular frame factory made with double shutter (wire gauged shutter & glass/glazed shutter, (wire cloth and glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete, two coats of synthetic enamel paint over one coat of red oxide primer including taking down old windows/ventilators complete all as specified and directed.
Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc.
M & L for Brick work with fly ash (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6.complete all as specified and directd.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.
M & L for rendering 5 mm thick on ceiling surfaces in cement mortar 1:3 finished even & fair all as specified and directed.
M & L for rendering 10 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:6 compound finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Rendering 15 mm thick on fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 with water proofing compound finished even and smooth without using extra cement complete all as specified and as directed. Note: water proofing compound shall be measured & paid seprately. Note: Where the items executed upto 10 mtr height, necessary scaffolding, props, jacks, shuttering and ladder shall be provided by the contractor in his own arrangement and the same is included in unit rates quoted. Green cloth shall be provided all around the work site for any position/height with all safety precaution (i.e. Safety Jacket, Safety Shoes, Safety Masks, Safety Helmet, Safety harness, Safety Goggles etc) Without safety precaution this work will not be commenced as decided by Engineer-in- Charge/ by AGE(I). NO extra cost shall be paid for such precaution. Such precaution shall be deemed to be included in the quoted rate.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L Preparation of newly plastered wall surfaces and applying two coats of distemper oil emulsion over one coat of birla white putty 1 mm thick preparatory to distempering complete all as specified and directed.
M&L for applying two coats of cement base paint over one coat of cement primer on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M & L for preparation of old decorated plastered surfaces of walls and applying two coat of cement base paint of approved colour, complete all as specified and directed
M&L for preparation of old plastered surface and applying two coat of oil bound distemper on walls over a coat of primer and 1 mm thick wall care putty including complete removal of existing treatment complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over Screed bed or bedding layer of mortar 10 mm thick for laying floor finishes over25 mm thick PCC 1:2:4 type B0 including dismantling of exsiting tiling/pcc floor/ wall any type and removing dubries outside of Md/OTM accn complete all as specified and directed. complete all as specified and directd.
M & L for Machine cut kota stone slab flooring 20-25mm thick riser of steps, skirting, dado over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including incl 10mm thick plaster in cm 1:4 including dismantling of exsiting tiling/pcc floor/ wall any type and removing dubries outside of Md/OTM accn complete all as specified and directed.
ABHISHEK ENTERPRISES (BID ID -3097061)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .